Benutzeranleitung / Produktwartung EG-30 THRU -75 des Produzenten Weil-McLain
Zur Seite of 24
For additional information, refer to . . . EG • PEG • EGH Boiler manual for Natural or Propane gas (tankless heater application optional) PEG-30 thru -65 EG-30 thru -75 Gas-Fir ed Boilers – Series 4 Contr ol supplement – Standing pilot This supplement must only be used by a qualified heat ing installe r/ser v ice technic ian.
2 Part Number 550-110-032/0607 EG-30 thru 75 Series 4 and PEG-30 thru 65 Series 4 EG-30 thru 75 Series 4 and PEG-30 thru 65 Series 4 Please read this page first! Hazard definitions The following de.
3 Part Number 550-110-032/0607 Standing Pilot Boilers — Contr ol Supplement T able of contents Hazard definitions and Note to the installer .................................................................................... 2 Control installation — EG-30 thru -75 water boilers without tankless heaters .
4 Part Number 550-110-032/0607 EG-30 thru 75 Series 4 and PEG-30 thru 65 Series 4.
5 Part Number 550-110-032/0607 Standing Pilot Boilers — Contr ol Supplement Figure 2 EG-75 water boilers without tankless heaters Figure 1 1. Mount and wire contr ols per wiring diagram, pag e 4, and Figure 1. a. A ttach junctio n bo x insid e left jack et pane l with #8-3 2 x ½” machine screws pro v ided.
6 Part Number 550-110-032/0607 EG-30 thru 75 Series 4 and PEG-30 thru 65 Series 4.
7 Part Number 550-110-032/0607 Standing Pilot Boilers — Contr ol Supplement Note: T ankless heater not available on EG-75 standing pilot boilers. EG-30 thru -65 water boilers with tankless heaters Control installation continued 1. Mount and wire contr ols per wiring diagram, pag e 6, and Figure 3.
8 Part Number 550-110-032/0607 EG-30 thru 75 Series 4 and PEG-30 thru 65 Series 4.
9 Part Number 550-110-032/0607 Standing Pilot Boilers — Contr ol Supplement 1. Mount and wire contr ols per wiring diagram, pag e 8, and Figure 5. a. Att ach j un ct i on box in si de le ft j a cke t p an e l w i t h #8-32 x ½” machine screws and green g round nuts pro v ided.
10 Part Number 550-110-032/0607 EG-30 thru 75 Series 4 and PEG-30 thru 65 Series 4.
11 Part Number 550-110-032/0607 Standing Pilot Boilers — Contr ol Supplement 1. Mount and wire contr ols per wiring diagram, pag e 10, and Figure 7. a. Att ach j un ct i on box in si de le ft j a cke t p an e l w i t h #8-32 x ½” machine screws and green g round nuts pro v ided.
12 Part Number 550-110-032/0607 EG-30 thru 75 Series 4 and PEG-30 thru 65 Series 4 Figure 8 V ent damper assemblies The following boiler models must have damper installed: • EG-30 thru EG-65, natural or propane gas. • PEG-30 thru PEG-65, steam, natural gas.
13 Part Number 550-110-032/0607 Standing Pilot Boilers — Contr ol Supplement Damper installation continued 4. Re ad an d a pp ly th e ha r ne s s pl ug wa r ni ng la b el (shown above) so that it is v isible after installa- tion. 5. Plug dam per har ness re ce ptac le int o dampe r harne ss plug.
14 Part Number 550-110-032/0607 EG-30 thru 75 Series 4 and PEG-30 thru 65 Series 4 Check out procedure Room thermostat anticipator settings W ater without tankless heater — 0.40 amps W ater with tankless heater — 0.20 amps Steam — Select based on gas valve and damper .
15 Part Number 550-110-032/0607 Standing Pilot Boilers — Contr ol Supplement Lighting instructions — Robertshaw 7200.
16 Part Number 550-110-032/0607 EG-30 thru 75 Series 4 and PEG-30 thru 65 Series 4 Lighting instructions — Honeywell VR8200/VR8300 Natural gas boilers only.
17 Part Number 550-110-032/0607 Standing Pilot Boilers — Contr ol Supplement Lighting instructions — Honeywell VR8200/VR8300 P ropane boilers only.
18 Part Number 550-110-032/0607 EG-30 thru 75 Series 4 and PEG-30 thru 65 Series 4 Lighting instructions — Robertshaw 7000ERHC.
19 Part Number 550-110-032/0607 Standing Pilot Boilers — Contr ol Supplement Figure 9 Manually opening v ent damper In event of vent damper failure: Effikal vent damper If troubleshooting chart r ecommends replacing actuator and actuator is not immediately available, damper blade can be fix ed in an open position to allow boiler operation.
20 Part Number 550-110-032/0607 EG-30 thru 75 Series 4 and PEG-30 thru 65 Series 4 Figure 11 1. Checking thermocouple or thermopile open system (Figur e 10): a. U se an electroni c multimete r , w ith leads fitted with alligator clips. Set meter scale to DC Milliv olts.
21 Part Number 550-110-032/0607 Standing Pilot Boilers — Contr ol Supplement T roubleshooting continued.
22 Part Number 550-110-032/0607 EG-30 thru 75 Series 4 and PEG-30 thru 65 Series 4 T roubleshooting continued.
23 Part Number 550-110-032/0607 Standing Pilot Boilers — Contr ol Supplement T roubleshooting continued.
24 Part Number 550-110-032/0607 EG-30 thru 75 Series 4 and PEG-30 thru 65 Series 4 Only dampers listed below are approv ed for use on EG-30 thr u 75 Series 4, and PEG-30 thr u 55 S eries 4, standing pilot ignition system boilers. A ny other damper installed can cause sever e personal injur y or death.
Ein wichtiger Punkt beim Kauf des Geräts Weil-McLain EG-30 THRU -75 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Weil-McLain EG-30 THRU -75 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Weil-McLain EG-30 THRU -75 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Weil-McLain EG-30 THRU -75 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Weil-McLain EG-30 THRU -75 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Weil-McLain EG-30 THRU -75 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Weil-McLain EG-30 THRU -75 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Weil-McLain EG-30 THRU -75. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Weil-McLain EG-30 THRU -75 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.