Benutzeranleitung / Produktwartung Boiler des Produzenten Weil-McLain
Zur Seite of 16
• Selection data • Installation • Piping • W ater treatment This manual must only be used by a qualified heating installer/service technician. Before installing, read all instructions, including this manual, the Ultra Boiler Manual and all applicable Supplements.
Part number 550-101-232/0703 2 GA S - FIRED WA TER BOILER — Installation Manual — Multiple-boiler S ystems Contents Hazard definitions ................................................................................................................
Part number 550-101-232/0703 3 GA S - FIRED WA TER BOILER — Installation Manual — Multiple-boiler S ystems The following defined terms are used throughout this manual to bring attention to the presence of hazards of various risk levels or to important information concerning the life of the product.
Part number 550-101-232/0703 4 GA S - FIRED WA TER BOILER — Installation Manual — Multiple-boiler S ystems Ratings and engineering data Figure 1 Ratings and engineering data (see page 5 for notes).
Part number 550-101-232/0703 5 GA S - FIRED WA TER BOILER — Installation Manual — Multiple-boiler S ystems For simplicity , the table on page 4 lists only sy stems using m ultiples of the same Ultra b oiler module. Any combination of Ultra boilers can be installed as a multiple boiler system.
Part number 550-101-232/0703 6 GA S - FIRED WA TER BOILER — Installation Manual — Multiple-boiler S ystems 1 . Boiler supply and return tappings are both 1" NPT . Connect to headers with 1” pipe for Ultra-80 and Ultra-105; 1¼" pipe for Ultra-155 and Ultra-230.
Part number 550-101-232/0703 7 GA S - FIRED WA TER BOILER — Installation Manual — Multiple-boiler S ystems 06-24-03 CONFIDENTIAL REVIEW & COMMENT ONL Y Placement and mounting information Placement, general 1 . Locate multiple boilers in boiler room according to: • Figure 3 (side-to-side), or • Figure 4 (back-to-back).
Part number 550-101-232/0703 8 GA S - FIRED WA TER BOILER — Installation Manual — Multiple-boiler S ystems 06-24-03 CONFIDENTIAL REVIEW & COMMENT ONL Y Easy -Fit ® P iping Figure 6 Single-sid.
Part number 550-101-232/0703 9 GA S - FIRED WA TER BOILER — Installation Manual — Multiple-boiler S ystems 06-24-03 CONFIDENTIAL REVIEW & COMMENT ONL Y Figure 8 Piping schematic — Typical pi.
Part number 550-101-232/0703 10 GA S - FIRED WA TER BOILER — Installation Manual — Multiple-boiler S ystems Figure 9 Typical piping for multiple Ultra boilers, using Weil-McLain Easy-Fit ® Manifo.
Part number 550-101-232/0703 11 GA S - FIRED WA TER BOILER — Installation Manual — Multiple-boiler S ystems Figure 10 Typical piping for multiple Ultra boilers, Weil-McLain Easy-Fit ® Manifolds, and indirect water heaters 1 Flow/check valve (each boiler) 2 Isolation valves (when used) 3 Caps 4 Easy-Fit ® Manifold (supply), sized per Fig.
Part number 550-101-232/0703 12 GA S - FIRED WA TER BOILER — Installation Manual — Multiple-boiler S ystems Figure 11 Typical piping for multiple Ultra boilers, using Weil-McLain Easy-Fit ® Manifolds and heat exchanger Use isolation heat exchanger for: 1.
Part number 550-101-232/0703 13 GA S - FIRED WA TER BOILER — Installation Manual — Multiple-boiler S ystems Figure 12 Manifolding combution air piping Combustion air & vent piping installation Vent piping 1.
Part number 550-101-232/0703 14 GA S - FIRED WA TER BOILER — Installation Manual — Multiple-boiler S ystems Figure 13 Connecting gas supply piping Gas piping Connecting gas supply piping 1 . Remove jacket front panel and refer to Figure 13 to pipe gas to boiler .
Part number 550-101-232/0703 15 GA S - FIRED WA TER BOILER — Installation Manual — Multiple-boiler S ystems Figure 14 Common gas piping, with manifolded gas header Common gas piping installation 4 . Size gas piping from meter outlet to entrance of gas header in acc ordance with T ables 1 and 2 belo w .
Part number 550-101-232/0703 16 GA S - FIRED WA TER BOILER — Installation Manual — Multiple-boiler S ystems Additional instructions Air for boiler room ventilation 1. Follow instructions in Ultra Boiler Manual to ensure the boiler room provides sufficient air infiltration.
Ein wichtiger Punkt beim Kauf des Geräts Weil-McLain Boiler (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Weil-McLain Boiler noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Weil-McLain Boiler - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Weil-McLain Boiler reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Weil-McLain Boiler erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Weil-McLain Boiler besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Weil-McLain Boiler verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Weil-McLain Boiler. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Weil-McLain Boiler gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.