Benutzeranleitung / Produktwartung WINEMATE WM1500 SSW des Produzenten Vinotemp
Zur Seite of 16
WINEMATE Split System Installation, Operation & Care Manual WM1500 SSW WM2500 SSW V V i i n n o o t t e e m m p p I I n n t t e e r r n n a a t t i i o o n n a a l l C C o o r r p p .
TABLE OF CONTENTS Important Safety Info rmation…..........................................2 Feature Description…………………………….……………..3 Installation Instruction………………………………………..5 Use and Temperature Control……………………………….
Important Safety Information • DO NOT USE A GROUND FAUL T INTERRUPTER (GFI). • A DEDICATED 20 AMPCIRCUIT IS HIGHLY RECOMMENDED. - 2 -.
Feature Description • WineMate split cooling system is designed and used to provide a stable temperature between 52~62 ° F for suitable space at a normal environment. • The refrigerated space will mainta in humidity of 50~70% RH even when the environment becomes dry and humid.
Evaporator Unit Condensing Unit - 4 -.
Installation Instruction Federal law requires that WINEMA TE split cooling systems be installed by an EPA certified refrigeration technician. 1. Location • Place the condensing unit in a properly v entilated location. If it is not, heat exhausted by the condensing unit will build up and the cooling sy stem will not operate properly.
The condensing unit and unit cooler are connected by a liquid line and an insulated suction line that are supplied by the insta ller. These lines must be properly sized for the distance between the two units. After the units and the lines are installed, the system must be pressure tested.
Use & Temperature Control 1. Temperature Setting • Set the temperature at 55 ° F for the optimum aging of wine • Set the temperature higher at very high ambient temperature.
1.2 Front Panel Commands 2) Alarm Signals 2.1 Code Description 2.2 Alarm Recovery Probe alarms P1”, start a few seconds afte r the fault in the re lated probe; they automatically stop a few seconds afte r the probe restarts normal operation. Check connections before replacing the probe.
1. Push the SET key for more than 3 seconds to change the Set point value; 2. The value of the set point will be di splayed and the “°C” or “°F” LED starts blinking; 3. To change the Set value, push the o or n arrows within 10s. 4. To memorize the new set point value, push the SET key again or wait 10s.
Care Guide In general, always unplug system or di sconnect power while doing care. 1. Coil Cleaning • Clean the condenser coil regularly . Coil may need to be cleaned at least every 6 months. • Unplug the system or disconnect power. • Use a vacuum cleaner with an ext ended attachment to clean the coil when it is dusty or dirty.
Troubleshooting This Troubleshooting Chart is not prepared to replace the training required for a professional refrigeration servic e person, not is it comprehensive Troubleshooting Chart Complaint Possible Causes Response 1. Unit not running a. Power cord unplugged b.
g. Low voltage h. Operating 60 Hz unit at 50Hz i. Sealed system problem j. Undercharge or overcharg e g. Check power sup ply h. Use proper 60 Hz i. Call service for checking loss of refrigerant or restrictions j. Call service to add or remove refrigerant 7.
Customer Support If you still have problems, please contact us at: Vinotemp International 17631 South Susana Road Rancho Dominguez, CA 90221 Tel: (310) 886-3332 Fax: (310) 886-3310 Email: info@vinotemp.
Warranty Thank you for choosing a Vinotemp wine cellar. Please enter the complete model and se rial numbers in the space provided: Model_____________ _________________________ __ _________________ Serial No._________________ ____________________ _________________ Attach your purchase receipt to this owner’s manual.
VINOTEMP will, at its discret ion, repair or replace the unit and return it free of charge to the original retail customer. If the unit is found to be in good working order, or beyond the initial twelve month period, it will be returned freight collect.
Ein wichtiger Punkt beim Kauf des Geräts Vinotemp WINEMATE WM1500 SSW (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Vinotemp WINEMATE WM1500 SSW noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Vinotemp WINEMATE WM1500 SSW - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Vinotemp WINEMATE WM1500 SSW reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Vinotemp WINEMATE WM1500 SSW erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Vinotemp WINEMATE WM1500 SSW besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Vinotemp WINEMATE WM1500 SSW verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Vinotemp WINEMATE WM1500 SSW. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Vinotemp WINEMATE WM1500 SSW gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.