Benutzeranleitung / Produktwartung T21 des Produzenten Viking Access Systems
Zur Seite of 44
VIKING VIKING BLUE ENABLED SOLAR EFFICIENT OPERA TION inst allation instructions class I, class II, class III, and class IV residential and commer cial v ehicular swing gat e oper ator and saf ety inf.
the viking T -21 ™ swing gat e oper ation 1HP with battery backup are simple but powerful words describing the Viking T -21™ gate operator . The T -21™ is our heavy duty swing gate operator capable of handling gates up to 1200 lbs. and 20’ long.
T-2 1 V ehicular Gate Operator • Revision B4 • November 2009.
TECHNICAL SUPPOR T 1 800 908 0884 i P AR TS DIA GRAM P AR TS DIA GRAM 20 22 29 21 24 6 4 3 2 1 32 Multi-Part Arm See Page 11 for Additional Details 25 11 30 (2) 18 19 30 8 9 13 12 14 7 28 23 26 27 17 15 16 10 31 5 Item Description P art No.
TECHNICAL SUPPOR T 1 800 908 0884 1 T ABLE OF CONTENTS T ABLE OF CONTENTS P arts Diagram/P arts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .i Important Safety Information Important Safety Instructions ....
TECHNICAL SUPPOR T 1 800 908 0884 2 W ARNING - Not following these instructions may cause sev ere injury or death to persons. IMPOR T ANT SAFETY INFORMA TION I MPOR T ANT SAFETY INFORMA TION IMPOR T ANT SAFETY INSTRUCTIONS W ARNING – To reduce the risk of severe injury or death: 1.
TECHNICAL SUPPOR T 1 800 908 0884 3 W ARNING - Not following these instructions may cause sev ere injury or death to persons. IMPOR T ANT SAFETY INFORMA TION I MPOR T ANT SAFETY INFORMA TION 6.
TECHNICAL SUPPOR T 1 800 908 0884 4 W ARNING - Not following these instructions may cause sev ere injury or death to persons. IMPOR T ANT SAFETY INFORMA TION I MPOR T ANT SAFETY INFORMA TION GENERAL SAFETY PRECA UTIONS The following precautions are an integral and essential part of the product and must be supplied to the user .
TECHNICAL SUPPOR T 1 800 908 0884 5 5 UL325 Gate Operator Classification CA UTION: T o Reduce the Risk of Fire or Injur y to P ersons GLOSSAR Y RESIDENTIAL VEHICULAR GA TE OPERATOR CLASS I – A vehicular gate operator (or system) intended for use in a home of one-to four single family dwelling, or a garage or parking area associated therewith.
TECHNICAL SUPPOR T 1 800 908 0884 6 IMPOR T ANT SAFETY INFORMA TION I MPOR T ANT SAFETY INFORMA TION Gate in Open Position Photo Beam Unit Reflector Potential Entrapment Area (Shaded) Radio Station Mag. Lock Mag. Lock Safety Connector Open Commands Guard Station Master/Slave Brake UL Siren Radio Rec.
TECHNICAL SUPPOR T 1 800 908 0884 7 W ARNING - Not following these instructions may cause sev ere injury or death to persons. IMPOR T ANT SAFETY INFORMA TION I MPOR T ANT SAFETY INFORMA TION Edge Sensor (contact sensor) Installation Secondary Entrapment Protection Manual Release When manual operation is required: 1.
TECHNICAL SUPPOR T 1 800 908 0884 8 Audible Alarm Reset Switch Installation W ARNING - Not following these instructions may cause sev ere injury or death to persons. IMPOR T ANT SAFETY INFORMA TION I MPOR T ANT SAFETY INFORMA TION W arning Placard Installation Manual Stop Button 5' Minimum S TOP 6' Radio Station Mag.
TECHNICAL SUPPOR T 1 800 908 0884 9 CA UTION - FOR USE WITH GA TES OF A MAXIMUM OF 12 FT IN LENGTH AND 2000 LBS. IN WEIGHT OR 20 FT IN LENGTH AND 1200 LBS.
TECHNICAL SUPPOR T 1 800 908 0884 10 PLANS OF INST ALLA TION P LANS OF INST ALLA TION B C C = A + 12" Inside Outside Gate in Closed Position D D = (L x 0.
TECHNICAL SUPPOR T 1 800 908 0884 11 PLAN OF INST ALLA TION – DET AILS P LAN OF INST ALLA TION – DET AILS Drill for a 1/2" x 3-1/2" Red Head Anchor (4) Places 23-1/4" 11" 2.
TECHNICAL SUPPOR T 1 800 908 0884 12 16 STEP 1 Release the clutch (see page 7). Cut the extension arms according to the desired plan of installation (Figure A on page 1 0). Note: Leave some additional material when cutting the extension arms to allow for additional adjustment.
TECHNICAL SUPPOR T 1 800 908 0884 13 17 Step 4 Upon observation of the satisfactory arrangement of the articulated arm and bracket, weld all pieces securely . P aint the arm to protect it from rusting. STEP 6 Check the Clutch adjustment. The Clutch is shipped factory adjusted.
TECHNICAL SUPPOR T 1 800 908 0884 14 18 The Gate Operator requires a single phase AC line to operate and charge the batteries. 1. Turn off the main switch or break er for the power line being used. 2. Move the selector switch on the Incoming V oltage Selector to the proper position (1 15 for 1 1 0 to 120V A C, 230 for 200 to 240V A C).
TECHNICAL SUPPOR T 1 800 908 0884 15 P ower Connections ELECTRICAL INST ALLA TION – SINGLE UNIT E LECTRICAL INST ALLA TION – SINGLE UNIT Connect the wire harness to the “OPEN RIGHT” connector if the gate opens to the right. Connect the wire harness to the “OPEN LEFT” connector if the gate opens to the left.
TECHNICAL SUPPOR T 1 800 908 0884 15 16 Left Limit Switch Right L imit Switch Clutch Limit Switch Cam Clutch Guide Pin Cam Wheel STEP 7 A. Loosen the screws on the Limit Switch Cams. B. With the operator cover still off, remount the articulated arm, making sure the cam wheel pin is engaged with the clutch.
TECHNICAL SUPPOR T 1 800 908 0884 17 Limit Switch Connections NC NO COM NC NO COM Cam Wheel Red Black Green White Left Limit Switch Right Limit Switch 1. Setup the limit switches manually at the desired open and close position. 2. Allow the gate operator to run a full open and close cycle (from limit to limit) without interruption.
TECHNICAL SUPPOR T 1 800 908 0884 18 OPTIONAL VIKING BLUE INST ALLA TION O PTIONAL VIKING BLUE INST ALLA TION 1. Decide which Operator will be the Master and which will be the Slave. 2a. Install the “Master” Viking Blue Module on the Master Control Board.
TECHNICAL SUPPOR T 1 800 908 0884 19 The control board provides a connector for master/slave connectivity . This connector will allow synchronized operation with a second gate operator . Wire the operators as shown above and interconnect the two operators as follows: Master Board Slave Board Purpose GND .
Inside Outside Exit Loop Inside Reopen Loop Center Loop Outside Reopen Loop Inside Outside 5' 5' 5' A A 5' Gate in Open Position Inside Reopen Loop Center Loop Outside.
TECHNICAL SUPPOR T 1 800 908 0884 21 VEHICULAR LOOP DETECTOR INST ALLA TION V EHICULAR LOOP DETECTOR INST ALLA TION Twist Wire Outside the Loop 6 Twists/Foot Until Its Connection to the Loop Detector .
TECHNICAL SUPPOR T 1 800 908 0884 22 Radio Station Mag. Lock Mag. Lock Safety Connector Open Commands Guard Station Master/Slave Brake UL Siren Radio Rec.
TECHNICAL SUPPOR T 1 800 908 0884 23 OPTIONAL ACCESSOR Y CONNECTIONS OPTIONAL ACCESSOR Y CONNECTIONS V ehicle loop detectors must be installed to decrease the possibility of vehicle entrapment on the gate (see page 20).
TECHNICAL SUPPOR T 1 800 908 0884 24 When connecting the Radio Receiver carefully verify the proper connections. The maximum voltage that the control board provides for external accessories is the maximum voltage of the battery , which is about 28 volts.
TECHNICAL SUPPOR T 1 800 908 0884 25 24 This Magnetic Lock is an OPTIONAL ACCESORY available from Vikin g A cce ss Sys tems. Please order part number V A-MA G13.
TECHNICAL SUPPOR T 1 800 908 0884 26 The guard station provides control of the gate operator to open, stop and close the gate. All three switches must be Normally Open type of switch, and can share the same common (ground). Place the control switch box within sight of the gate, away from moving parts of the gate and out of reach of children.
TECHNICAL SUPPOR T 1 800 908 0884 27 Auto-Open Feature SPECIAL FEA TURES S PECIAL FEA TURES Radio Station Mag. Lock Mag. Lock Safety Connector Open Commands Guard Station Master/Slave Brake UL Siren Radio Rec.
TECHNICAL SUPPOR T 1 800 908 0884 28 28 SPECIAL FEA TURES S PECIAL FEA TURES The Obstruction Sensor de tec ts obs tru cti ons in the pat h of the traveling gate. The Trim P ot for the Obstruction Sensor adjusts the se nsi ti vit y l ev el that triggers the Sensor .
TECHNICAL SUPPOR T 1 800 908 0884 29 SPECIAL FEA TURES S PECIAL FEA TURES 1 Fail Safe: If the operator has been installed with an Elbow Arm, the Clutch Key can be removed and the gate can me moved manually with a relative low amount of force. Fail Secure: This unit is shipped with the default fail secure feature.
TECHNICAL SUPPOR T 1 800 908 0884 30 SPECIAL FEA TURES S PECIAL FEA TURES Inside Outside Opens First Slave Unit Master Unit Interconnecting Conduit Gate Overlap Setting Setting the Overlap Delay P ot to any value other than zero will cause the master unit to delay in opening.
TECHNICAL SUPPOR T 1 800 908 0884 31 B A TTER Y & EMI BOARD LOCA TION B A TTER Y & EMI BOARD LOCA TION The Batteries are Located Behind the Panel Door The EMI Board is Located Behind the Panel.
TECHNICAL SUPPOR T 1 800 908 0884 32 OPTIONALSOLAR P ANEL INST ALLA TION O PTIONAL SOLAR P ANEL INST ALLA TION For Viking Vehicular Gate Oper ators Radio Station Mag. Lock Mag. Lock Safety Connector Open Commands Guard Station Master/Slave Brake UL Siren Radio Rec.
TECHNICAL SUPPOR T 1 800 908 0884 33 OPTIONALSOLAR P ANEL INST ALLA TION O PTIONAL SOLAR P ANEL INST ALLA TION For Viking Vehicular Gate Oper ators STEP 1 Use a 24V solar panel or two solar panels of 12V in series with a total capacity of 80 W atts.. STEP 3 Replace the existing batteries with a battery pack of 35AHr or greater .
TECHNICAL SUPPOR T 1 800 908 0884 34 31 OPTIONAL VIKING BLUE INST ALLA TION O PTIONAL VIKING BLUE INST ALLA TION Radio Station Safety Connector Open Commands Guard Station Master/Slave Brake UL Siren OPEN RIGHT 24V BAT 24VAC OPEN LEFT Hold Open Timer Stop Close Open Obstruction Sensor min.
TECHNICAL SUPPOR T 1 800 908 0884 T ECHNICAL SUPPOR T 1 800 908 0884 Se habla Español 35 28 Gate does not run – Motor Sensor indicator comes ON TROUBLESHOOTING T ROUBLESHOOTING Check all motor connections to be fully engaged. Refer to page 15. Check the 15 Amp fuse in the control board.
TECHNICAL SUPPOR T 1 800 908 0884 26 36 29 TROUBLESHOOTING T ROUBLESHOOTING Gate does not open or close Check all motor connections to b e fully engaged. Refer to page 15. Check that limit switches are connected to the common and the normally close position.
TECHNICAL SUPPOR T 1 800 908 0884 37 TROUBLESHOOTING T ROUBLESHOOTING Check the incoming high voltage power supply . Check the proper selection of power supply (120/220 V A C). Refer to page 14. V erify the EMI board by reading high voltage across the (4) blue and red wires at the terminal block connections.
Notes.
our continuous commitment t o e xcellence Viking Access Systems is continuously working hard to identify and design products that will appeal to the industry and it’s needs. As technology continues to advance, we have developed a completely efcient and intelligent line of gate operators to meet the changing demands.
VIKING st andard f eatur es and oper at or specications Accessible manual releases • Fail-Safe option sets the gate to automatically transfer to a fail-safe mode in the event of a power failure, .
Ein wichtiger Punkt beim Kauf des Geräts Viking Access Systems T21 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Viking Access Systems T21 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Viking Access Systems T21 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Viking Access Systems T21 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Viking Access Systems T21 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Viking Access Systems T21 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Viking Access Systems T21 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Viking Access Systems T21. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Viking Access Systems T21 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.