User’s Guide Value Series Model VS375C, VS575C.
For your records The serial number of your UPS is on the rear panel. You should note the serial number in the space provided below. Retain this booklet as a permanent record of your purchase to aid in identification in the ev ent of theft or loss. Model No: Serial No.
LIMITED WARRANTY What the warranty covers: We warrant this product to be free from defec ts in material and workmanship during the warranty period. If a product proves to be defecti ve in material or workmanship during the warranty period, we w ill at our sole option r epair or replace the product with a like product.
Limitation of implied warranties: THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, WHICH EXTEND BEYOND THE DESCRIPTION CONTAINED HEREIN INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Exclusion of damages: OUR LIABILITY IS LIMITED TO THE COST OF REPAIR OR REPLACEMENT OF THE PRODUCT.
Life Support: We do not recommend the use of our UPS produc ts for life support equipment or direct care where failure of a UPS product could cause failu re of, or diminished effectiveness of the life support equipment or patient care.
.
VS375C/VS575C 1 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS ! THIS MANUAL CONTAINS IMPORTANT SAFETY INSTRUCTIONS. KEEP THIS MANUAL HANDY FOR REFERENCE. ♦ CAUTION: A BATTERY CAN PRESENT A RISK OF ELECTRICAL SHOCK, BURNS FROM HIGH SHORT-CIRCUIT CURRENT, FIRE OR EXPLOSION FROM VENTED GASES.
2 VS375C/VS575C ♦ CAUTION: ! THE UPS CONTAINS VOLTAGES WHICH ARE POTENTIALLY HAZARDOUS. ALL REPAIRS SHOULD BE PERFORMED BY QUALIFIED SERVICE PERSONNEL. THE UPS HAS ITS OWN INTERNAL ENERGY SOURCE (BATTERY). THE OUTPUT RECEPTACLES MAY BE LIVE EVEN WHEN THE UPS IS NOT CONNECTED TO AN AC SUPPLY.
VS375C/VS575C 3 FEDERAL COMMUNICATIONS COMMISSION (FCC) WARNING: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protecti on against harmful interference in a residential installation.
4 VS375C/VS575C TABLE OF CONTENTS 1. INTRODUCTION 1.1 Overview 5 1.2 Frequency Auto-Selection 5 1.3 User Replaceable Battery Design 5 1.4 Over Voltage and Under Voltage Protection 6 1.5 Schedule Shutdown & Startup 6 1.6 Data-Line Surge Protection 6 2.
VS375C/VS575C 5 1. INTRODUCTION 1.1 Overview The Value Series of Uninterruptible Power Systems ( UPS ) was designed to prevent spikes, transients and blackouts from reac hing your sensitive equipment. Your equipment may include such items as comput ers and computerized instruments to telecommunication systems.
6 VS375C/VS575C 1.4 Over Voltag e an d Under Voltage Protectio n The UPS will switch to backup mode and provide the power from its internal battery w hen the input line voltage is too low or too high.
VS375C/VS575C 7 2. UPS CONTROLS 2.1 External Views 2.2 Power On/Off/Test/Silence Button: The On/Off/Test/Silence Butt on has four functions: 1. When the UPS is off and AC power is present, press this button for more than 3 seconds to turn on the UPS. The UPS can be turned on even when AC power is not present.
8 VS375C/VS575C AC Mode When this Green LED is lit, the UPS is in normal mode, and providing power to your equipment. The UPS will continue to filter and provide surge protection. Battery Mode When this Yellow LED is lit, the UPS is providing pow er from its battery.
VS375C/VS575C 9 3. INSTALLATION AND OPERATION Before installation, please read and understand the following instructions: 3.1 Unpacking and Insp ectio n Examine the packing carton for damage and accessory in the box. Notify the carrier immediately if damage is observed.
10 VS375C/VS575C View So nic G8 10 120V 2.7A 50 / 60 Hz SN: Q771515388 Computer Co Pent ium Pro 200MHz 120V 2.0A 50/60 Hz SN: 123456 3. Multiply the voltage and current of each piece of equipment ( VA requirements ); for example, 120V x 2.7A = 324VA, 120V x 2.
VS375C/VS575C 11 3.5 Connecting Your Equipment to the UPS 1. For all UPS models except the 2x0V ve rsions: connect the power cord(s) of your computer equipment to the output receptacle(s) of the UPS.
12 VS375C/VS575C Note: Backup all unsaved files before you perform the following functional test. 3. To test the backup function, you may unplug the pow er cord of the UPS. During this test, observe that your equipment operates properly and w ithout interruption.
VS375C/VS575C 13 4. SPECIFICATIONS 4.1 Electrical Specifications Product Name Frequency (Hz) Voltage (V) Capacity VA / W 100 / 110 / 120 VS375C 50/60 220 / 230 / 240 375VA / 225W 100 / 110 / 120 VS575.
14 VS375C/VS575C Audible A larm: Battery discharge at power failure Beep every 4 seconds Battery approaches final discharge Beep every second Overload Continuous buzzer 4.2 Mechanical Sp ecificatio ns: Product Name Dimensions Weight (Kg) W × D × H ( mm ) Net Gross VS375C 200*77*175 2.
VS375C/VS575C 15 5. TROUBLESHOOTING If the UPS fails to operate properly, please review the following steps before calling the repair center: 1. Is the UPS plugged into a proper working outlet? 2. Is the line voltage within the rating specified? 3. Does the circuit breaker on the rear panel need to be reset? 5.
16 VS375C/VS575C 6. USER REPLACEABLE BATTERY The Batteries inside your UPS should last fr om between 3 to 5 years. If you suspect that the batteries are weak, allow the UPS to c harge the batteries for at least six hours and then test the backup time.
VS375C/VS575C 17 6.2 Battery Replacemen t Pro cedure for VS375C/ VS575C Changing the batteries in your UPS is a sa fe and easy procedure. Since the battery is isolated from the AC input you may leave your UPS and computer or other equipment on during the following procedure.
18 VS375C/VS575C Fuse Replacement Procedure 1. Use a slotted screwdriver to take out the fuse socket. 2. Take out the broken fuse from the fuse socket. 3. Throw away the broken fuse. 4. Use the slotted screwdriver to push out the spare fuse. 5.
Ein wichtiger Punkt beim Kauf des Geräts ViewSonic VS575C (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie ViewSonic VS575C noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für ViewSonic VS575C - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von ViewSonic VS575C reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über ViewSonic VS575C erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon ViewSonic VS575C besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von ViewSonic VS575C verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit ViewSonic VS575C. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei ViewSonic VS575C gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.