Benutzeranleitung / Produktwartung VEFSGE 304 SC.. des Produzenten Verona
Zur Seite of 24
GAS/ELECTRIC RANGE for residential use only THIS RANGE IS FOR RESIDENTIAL USE ONL Y FOR INST ALLER ONL Y Some models are supplied with a protective lm on steel and aluminium parts. This lm must be removed before installing/using the appliance. Models: VEFSGE 304 SC.
2 WARNING ! T o reduce the risk of tipping the appliance, the appliance must be secured by properly installed anti-tip device packed with the appliance.
3 This appliance isdesigned and manufactured solely forthe cooking of domestic (household) food and in not suitable for any none domestic application and therefore should not be used in a com- mercialenvironmement.
4 INST ALLA TION INSTRUCTIONS W ARNING! THIS APPLIANCE MUST BE INST ALLED BY A QUALIFIED INST ALLER. Improper installation, adjustment, alteration, services, or maintenance can cause injury or property damage. Consult a quali - ed installer , service agent, or the gas supplier .
5 GENERAL INFORMA TION 1. Installation must conform with local codes or , in the absen- ce of local codes, with the National Fuel Gas Code , ANSI Z223.1/NFP A 54 - Latest Edition, CAN/CGA-B149.
6 PROXIMITY T O SIDE CABINETS 1. This range may be installed directly adjacent to existing 36” (914 mm) highbasecabinets. Rangedimensions: • width:29”7/8(759mm) • depth:24”13/64(614.
7 A A B ASSEMBLING THE BACKGUARD It is mandatory to install the backguard. Assemblethebackguardasshowningure1.3: • Screwthe2screws“ A ”interposingthespacers. • Screwthecentralscrew“ B ”.
8 B G E D C F A A B C E D F G A A PROXIMITY T O SIDE CABINETS ST ANDARD INST ALLA TION Fig. 1.4b Fig. 1.4a OVEN VENT Ref. inch mm A 0” 0 B 36” 914 C 1 1”13/16 300 D 30”minimum 762mini.
9 PROXIMITY T O SIDE CABINETS ISLAND INST ALLA TION A A B G E D F C H A A B G E D F C H Fig. 1.5b Fig. 1.5a OVEN VENT Ref. inch mm A 0” 0 B 36” 914 C 1 1”13/16 300 D 30”minimum 762min.
10 1 LEVELLING THE RANGE Therange isequipped with4 LEVELLINGFEETand maybe levelledby screwingor unscrewingthefeet(gs.1.6-1.7). Itisimportanttoobservethedirectionsofgures1.
11 1 INST ALLING THE COOKTOP FRONT GUARD T o increasethe clearance between the front edgeof the cooktop and the burnersit is possible to install thecooktop front guard supplied withtheappliance.
12 gas connection 2 2. Pressure Regulator: a. Allheavyduty ,commercialtypecookingequipmentmusthaveapressureregulator onthe incomingservice linefor safeand efcientoperation, sinceservice pressure mayuctuatewithlocaldemand.
13 2 LOCK Arrow PRESSURE REGULA TOR INST ALLA TION STEP 1 Mountthe1/2”NPT (conical)maleconnectortothepressureregulatorand tightenbyusingawrench. Donotovertightentheconnector . Overtighteningmaycrackregulator .
14 2 Fig. 2.4 GAS CONNECTION SPEFICICA TION Range manifold Manifold male pipe tting 1/2”Gcylindrical (ISO228-1)male 1/2”Gcylindrical (ISO228-1)female Gasket Extension pi.
15 2 b. Any conversion required must beperformed by yourdealer or aqualied licen- sed technician or gas service company . Please providethe service person with this manual before work is started on the range.
16 2 Pressur e regulator 1 2 NATURAL GAS REGULATION LP/PROPANE REGULATION A REGULA TOR COVER CONVERSION TO LP/PROP ANE GAS (OR CONVERSION BACK TO THE ORIGINAL GAS - NA TURAL GAS) Everyrangeisprovidedwithasetofinjectorsforthevarioustypesofgas.
17 2 OPERA TIONS TO BE PERFORMED WHEN SUBSTITUTING THE INJECTORS • Removethepansupports,theburnercapsandtheamespreaders.
18 Fig. 2.10 R 1 Regulationscrew(Semirapidburner) R 2 Regulationscrew(Innercrownofdualburner) R 3 Regulationscrew(Outercrownofdualburner) R 1 R.
19 electrical connection 3 W ARNING TO A VOID ELECTRICAL SHOCK HA- ZARD, BEFORE INST ALLING THE APPLIANCE, SWITCH POWER OFF A T THE SERVICE P ANEL AND LOCK THE P ANEL TO PREVENT THE PO- WER FROM BEING SWITCHED ON ACCIDENT ALL Y .
20 3 3-Wire Power Cord Installation (SeeFigure3.2) 1. Remove the T erminal Block Access Plate on the back of the rangebyunscrewingthe4xing Screws (Figure3.1). 2. Check the correct positioning of the Power Cord Bracket as pergure3.
21 3 3-Wire Conduit Installation (SeeFigure3.5) 1. Remove the T erminal Block Access Plate on the back of the rangebyunscrewingthe4xing Screws (Figure3.4). 2. Check the correct positioning of the Conduit Bracket as per gure3.
22 3 WIRING DIAGRAM ELECTRIC DIAGRAM KEY IC IGNITIONCOIL ISG IGNITIONSWITCHESGROUP OL OVENLAMP E61 RELA Y CE CIRCULARELEMENT GE BROIL ELEMENT TE TOP ELEMENT BE-INT BOTTOMELEMENT INT . BE-EXT BOTTOMELEMENT EXT .
23.
Themanufacturer cannot beheld responsiblefor possibleinaccuracies due toprin- tingortranscriptionerrorsinthepresentbooklet.
Ein wichtiger Punkt beim Kauf des Geräts Verona VEFSGE 304 SC.. (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Verona VEFSGE 304 SC.. noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Verona VEFSGE 304 SC.. - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Verona VEFSGE 304 SC.. reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Verona VEFSGE 304 SC.. erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Verona VEFSGE 304 SC.. besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Verona VEFSGE 304 SC.. verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Verona VEFSGE 304 SC... Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Verona VEFSGE 304 SC.. gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.