INST ALLER / CONSUMER SAFETY INFORMA TION 20004409 12/04 Rev . 10 PLEASE READ THIS MANUAL BE- FORE INST ALLING AND USING APPLIANCE. W ARNING! IF THE INFORMA TION IN THIS MANUAL IS NOT FOLLOWED EX- A CTL Y , A FIRE OR EXPLOSION MA Y RESUL T CA USING PROPER TY D AMA GE, PERSONAL INJUR Y OR LOSS OF LIFE.
2 2 Radiance Natural Vent Gas Heater 20004409 PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. Thank you and congratulations on your purchase of a Vermont Castings stove. IMPORTANT: Read all instructions and warnings carefully before starting installation.
3 Radiance Natural Vent Gas Heater 20004409 The Radiance Natural V ent Room Heater , Model Nos. 3340 thru 3349, 3355, 3356 is a vented gas appliance listed to the ANSI Standard Z21.88b-2001 and CSA-2.33b-2001 for V ented Room Heaters, and CSA 2.17-M91, Gas-Fired Appliances For Use at High Altitudes.
4 4 Radiance Natural Vent Gas Heater 20004409 Stove Dimensions See Page 5 for Flue Collar Centerline Dimensions. 4409 Fig. 1 Radiance dimensions. RADIANCE 29 ³⁄₄ " (756mm) 31" (787mm) 14 ⁷⁄₈ " (378mm) 4" Inner Dia.
5 Radiance Natural Vent Gas Heater 20004409 Clearance Requirements Minimum Clearances to Combustible Materials Measure side clearances as shown in Figures 2 through 5 from the outer edge of the cast iron stove top. Measure rear clearances from the rear sheet metal shroud.
6 6 Radiance Natural Vent Gas Heater 20004409 Venting Requirements and Options The Radiance must be properly connected to a listed 4” (102mm) Type B venting system or to an approved Class A masonry or factory-built chimney system. In Canada, a complete relining of Class A chimney systems is required.
7 Radiance Natural Vent Gas Heater 20004409 Passing Through a Combustible Wall or Ceiling An approved pass-through device is always required when a vent passes through a combustible wall or ceiling. Check with the maker of the vent system for the correct listed devices that are available.
8 8 Radiance Natural Vent Gas Heater 20004409 Tools Required • Phillips screwdriver (stub) • power drill • utility knife • reciprocating saw • metal drill bit: size 28 (.140"/3.5mm) Unpack and Set Up the Stove The Radiance is shipped on its back.
9 Radiance Natural Vent Gas Heater 20004409 A ST363 Rear shroud Cover Plate (Shipping Position) Fig. 11 Remove/replace rear shroud. Rear Shroud 1. The fan kit includes a Blower Assembly and a Rheostat Assembly , connected by a cable.
10 10 Radiance Natural Vent Gas Heater 20004409 5. Attach the fan assembly to the fan bracket provided in the finish bag. Use the #10 sheet metal screws provided with fan kit. Do not remove finger guard screws. (Fig. 16) 6. Connect snapstat leads. Disconnect the snapstat module from the leads inside the snapstat bracket.
11 Radiance Natural Vent Gas Heater 20004409 Pinch Grommet to Remove Snapstat Module Snapstat Bracket ST670 Fig. 17 Remove the snapstat and grommet from the bracket and insert the grommet into the inner shroud. Slot Outer Shroud Inner Shroud Slot ST194 Fig.
12 12 Radiance Natural Vent Gas Heater 20004409 ST373 Fig. 23 Attach the B-vent adapter to the flue. do not need to be fastened at each joint, other than slip sections.
13 Radiance Natural Vent Gas Heater 20004409 Connect the Gas Supply Line Check the Rating Plate attached by a steel cable to the firebox, to confirm that you have the appropriate firebox for the type of fuel to be used. The Radiance may be converted from one gas to another using the appropri- ate Fuel Conversion Kit listed on Page 26.
14 14 Radiance Natural Vent Gas Heater 20004409 Install Rear Bracket and Log Set 1. Remove the logs from their packaging, and inspect each piece for damage. DO NO T INST ALL DAM- AGED LOGS. 2. Install the left rear log by placing it on the rear log bracket at the back of the firebox.
15 Radiance Natural Vent Gas Heater 20004409 LG156 Fig. 28 Install the left and right rear logs and the right log. Decorative Grate Right Log Right Rear Log Left Rear Log Left Bracket Right Bracket Fig. 30 Place lava rock on top of burner just behind decorative grate.
16 16 Radiance Natural Vent Gas Heater 20004409 Operable Doors The Radiance is shipped with the operable door front. The stove may be operated with the doors either open or closed. To open the front doors, insert the handle into the door latch stub and turn it to the right and up.
17 Radiance Natural Vent Gas Heater 20004409 3. Open control access panel. 4. Push in gas control knob slightly and turn clockwise to "OFF". Do not force. 5. Close control access panel. 1. STOP! Read the safety information above. 2. Turn off all electrical power to the fireplace.
18 18 Radiance Natural Vent Gas Heater 20004409 A. Defective or misaligned Using a match, light [ilot. If pilot lights, turn off pilot and electrode at the pilot push the ignitor button again. If pilot will not light, check gap at electrode and pilot - it should be 1/8” to have a strong spark.
19 Radiance Natural Vent Gas Heater 20004409 Fuel Conversion Instructions W ARNING! This con version kit shall be installed by a qualified service agency in accordance with the manufacturer’ s instructions and all applicab le codes and requirements of the authority having jurisdiction.
20 20 Radiance Natural Vent Gas Heater 20004409 Conversion to Natural Gas Input (BTU/h) Kit # Front Part # Rear Part # Minimum Maximum 000-5009 #51 30000449 #40 20004263 25,000 35,000 Conversion to LP Input (BTU/h) Kit # Front Part # Rear Part # Minimum Maximum 000-5010 #57 20004587 #54 20000130 27,500 35,000 Ta b le 2.
21 Radiance Natural Vent Gas Heater 20004409 Maintenance Y our Radiance Gas Heater will provide years of service with minimal upkeep. The following procedures will help ensure that your stove continues to function properly . Annual System Inspection Have the entire heater and venting system inspected annually by a qualified gas technician.
22 22 Radiance Natural Vent Gas Heater 20004409 Gasket Replacement The Radiance Gas Heater uses a ‘tadpole’ type gasket to seal between the glass panel and the frame. In time, this gasket can become brittle and compressed and should be replaced. New gasket is available from your dealer .
23 Radiance Natural Vent Gas Heater 20004409 NO TE: IF ANY OF THE ORIGINAL WIRE, AS SUP- PLIED WITH THE APPLIANCE, MUST BE RE- PLACED, IT MUST BE REPLACED WITH TYPE SF- 2, 200 ° C WIRE OR ITS EQUIV ALENT .
24 24 Radiance Natural Vent Gas Heater 20004409 1a 1b 1c PILO T O N O F F PILOT ADJ L O H I TPTH TH TP 2 3 6 7 20 7a,b 17 4 8a,b,c,d 16 19 27 28 26a,b, c,d 25 18a,b 29 21 22 23 5 24 30 9a,b 11 10 15a,.
25 Radiance Natural Vent Gas Heater 20004409 Radiance Natural V ent (RNV OD) (continued) Models: 3340 thru 3349, 3355, 3356 Ref. Description RNVOD 1. Log Set -RDVOD/RNVOD 20004184 1a. Right Rear Log RDNOD/RNVOD 20004185 1b. Left Rear Log RDVOD/RNVOD 20004186 1c.
26 26 Radiance Natural Vent Gas Heater 20004409 Radiance Natural V ent (RNV OD) (contin ued) Models: 3340 thru 3349, 3355, 3356 Ref. Description RNVOD 28. Bracket, Left Log 20005258 29. Base Pan Inner Gasket 20004286 30. Bracket, Back Log - RDVOD 20003577 31.
27 Radiance Natural Vent Gas Heater 20004409 Optional Accessories Fan Kits FK26 Fan The FK26 fan kit helps distribute heated air from within the firebox out into the room. The fan is controlled by a snapstat that turns power on and off as the firebox temperature rises above and falls below a preset temperature.
28 28 Radiance Natural Vent Gas Heater 20004409.
29 Radiance Natural Vent Gas Heater 20004409.
30 30 Radiance Natural Vent Gas Heater 20004409 BASIC WARRANTY CFM Specialty Home Products (hereinafter referred to collectively as the Company) warrants that your new Vermont Castings or Majestic Gas.
31 Radiance Natural Vent Gas Heater 20004409 GARANTIE DE BASE La société CFM Specialty Products (ci-après la « Société ») garantit votre nouveau poêle/foyer au gaz Vermont Castings ou Majestic.
410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 • 905-670-7777 www .majesticproducts.com • www .vermontcastings.com CFM Specialty Home Products.
Ein wichtiger Punkt beim Kauf des Geräts Vermont Casting 3355 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Vermont Casting 3355 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Vermont Casting 3355 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Vermont Casting 3355 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Vermont Casting 3355 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Vermont Casting 3355 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Vermont Casting 3355 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Vermont Casting 3355. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Vermont Casting 3355 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.