Benutzeranleitung / Produktwartung TurboTeuton P500 des Produzenten Unigreen
Zur Seite of 36
04/2010 USE AND MAINTENANCE MANU AL MISTBLO WERS TURBO TEUT ON MOUNTED MISTBLO WERS serie TURBO TEUT ON - MAIA - TT : P P olipo - P SuperSpalliera - R V -GD V Read this manual carefully bef ore use.
2 unigreen Summary 1 USING AND KEEPING THE USE AND MAINTENANCE MANU AL ...................................... 4 1.1 COMPOSITION OF THE MANUAL ................................................................................................... .... 4 1.
unigreen 3 6.2 DESCRIPTION OF TYPE OF NOZZLES ............................................................................................ 20 6.2.2 LO W V OLUME CONICAL NOZZLES (150-500L/HA) ............................................................
4 unigreen Thank you f or having chosen UNIGREEN. The product you purchased has been designed and b uilt with the greatest attention to the safety of the oper ator and the environment, ne vertheless there are still some residual risks due to the nature of the product used.
unigreen 5 2 SAFETY REGULA TIONS AND RESIDUAL RISKS In relation to saf ety , the f ollowing ter ms will be used: Dangerous zones: any z one inside and/or near the machine where the presence of a person e xposed constitutes a r isk f or the safety and health of the same person.
6 unigreen 2.1 INTENDED USE The spra yer in this series is built f or agricultural use. The mater ials used are resistant to nor mal chemical products used in agricultural spra ying (or herbicides) at the time of construction.
unigreen 7 Ref er to the enclosed handbooks for the use and maintenance of the pump and pressure regulator and any accessories or motors. b) Please contact the agent in your z one, the nearest authorised workshop or UNIGREEN S.p .A. directly f or any repairs the user f eels they aren’t capable of perf or ming alone.
8 unigreen 3.2 NOISE LEVEL OF THE MACHINE Use earmuffs to protect your ears when using the machine, belo w you will find the data on the maximum noise le vels during work.
unigreen 9 4.1.2 HAND W ASHING T ANKS The mistblo wers are supplied with an auxiliary hand-washing tank with clean water and a hand tap . This tank must alwa ys be supplied with water and the inside must be clean so you can w ash any par ts of the body that come into contact with the chemical product used.
10 unigreen 4.4 TRA CTOR COUPLING The tractor must ha ve 1”3/8 ASAE DIN 9611/A pow er-takeoff that runs at 550 r pm. It must hav e a 3-point elev ator suitable for saf ely suppor ting the weight of the atomiser . Check this by consulting the tab le of allowed fittings N° 17a (pages 34).
unigreen 11 4.5 CARD AN SHAFT In some models this is supplied on request. The cardan shaft must bear the CE mark. It must alwa ys have its o wn instr uctions that must be follo wed scrupulously and it should come with a cov er bear ing the mark, integrated in e very par t .
12 unigreen 4.8 PRESSURE REGULA TOR T o use the pressure regulator , f ollow the instructions in the enclosed hand- book scrupulously . The pressure regulator controls all of the most impor tant spra ying functions, the thorough knowledge of its functions mak es work easier and more precise.
unigreen 13 = adjust maximum pressure v alve B to the w or king value (in an y case less than the safe maxim um pressure the system can reach). Pressure regulators with a v olumetric valve (GCP ELETTRICO) Adjusting the maximum pressure v alve = put main control A in the dr ain position (“OFF”).
14 unigreen 4.10 FILLING THE T ANK The machines f or defensiv e crop treatments, in consideration of the saf ety of persons, animals and the protection of the en vironment, must only be filled indirectly from open water courses and only b y free-falling w ater from the waterw or ks.
unigreen 15 4.12 MIXING The active principle can be mix ed using the relev ant stirrers before and during the treatment. Correct mixing and stirring is the basis of the correct distribution on the crops. We recommend some useful accessories such as the premix er for powders and liquids (see the f ollowing para graph).
16 unigreen 4.13 W ASHING THE A TOMISER After ev er y treatment, thoroughly clean the equipment, washing it with water inside and out. Dir ty equipment is v er y dangerous for people and in particular for children. Discharging the residues of washing in the en vironment without taking precautions is forbidden as this pollutes w ater courses.
unigreen 17 5 BLO WER GROUP All the mistblower s have a high speed fan rotor . Y ou must take great care and beware of the eff ects that this can prov oke: such as the aspiration and projection of f oreign bodies which, although of a small size, can be very dangerous especiall y for the ey es and face .
18 unigreen 5.3 DISTRIBUT OR ACCESSORIES V arious configurations of accessor ies or distributors are fitted to the outlet of the fans . At present these are: P olipo - Super Spalliera - R V GDC W ARNI.
unigreen 19 5.4 HYDRA ULICS The R V , VL, VLX, FXF and FXL model distributor accessories hav e hydraulics that can be controlled by the operator directly from the seat in the cab . Check that no one and nothing is in the area where the booms will open; par ticular attention should be paid to the presence of any electric power lines .
20 unigreen 6 SPRA YING W ARNING: the indications to f ollow for using chemical products are indicated in paragr aph 2.2.1. 6.1 DESCRIPTION OF THE DIFFUSERS The distributor accessories of the T urboT euton range are equipped with variab le diffusers (FIG.
unigreen 21 6.3 CALIBRA TING TURBO TEUT ON The tables on pages 26-31 let y ou easily calculate the distribution in litres/ hectare of the mistblo wers with the standard fittings, proceeding as indicat.
22 unigreen 7 HAND LANCES When using hand lances bear in mind the follo wing notes: = Don’t direct the jet of liquid towards electric pow er lines or zones where there is electrical current, houses or where people might pass. = Don’t point the jet at people or animals.
unigreen 23 ov erheating. This lubrication can be done with grease or oil: oil allows significantly higher speeds, in general g rease is used to lubricate bear ings with a vertical or inclined axis as it stays in the z one for longer .
24 unigreen the instructions in the present user’ s handbook and in the enclosures of the pump, pressure regulator and accessories. 8.7 DEMOLITION AND DISPOSAL When the spra yer will be put out of ser vice you should w ash it with great care to remov e any residues of chemical product, f ollow the instructions in point 4.
unigreen 25 part description code single Ø18 non-drip jet for mistblower with diaphragm (1/4" mount) without nozzles 1224/0194F double Ø18 non-drip jet for mistblower with diaphragm (1/4" .
26 unigreen unigreen s pa Tabe l l a e rogazi one in Li t ri /ett aro Turbo Te ut on 16 ge tt i Lt . / ha sp reading rat e t able f or T urb o T eut on 16 N OZ Z LES I S O OL I V A -O l i v e I S O AR.
unigreen 27 unigreen s pa Tabe l l a eroga z i one in Li tr i / et ta ro Turbo Teut on 1 6 get ti Lt . / ha spr eading r at e t able f or T urbo T eut on 16 NO Z Z LES ISO O LIVA - O liv e ISO A R A N.
28 unigreen unigreen s pa Tabe l l a e rogazi one in Li t ri /ett aro Turbo Te uton 2 0 ge tt i Lt . / ha spr eading r at e t able f or T urbo T eut on 20 NO Z Z LES ISO O LIVA - Oliv e ISO A R A N C .
unigreen 29 unigreen s pa Tabe l l a eroga z i one in Li tr i / et t aro Turbo Te uton 2 0 get ti Lt . / ha spr eading r at e t able f or T urbo T eut on 20 NO Z Z LES ISO O LIVA - Oliv e ISO A R A N .
30 unigreen unigreen s pa Tabe l l a eroga z i one in Li tr i / et ta ro Turbo Teut on 2 0 get ti Lt . / ha spr eading r at e t able f or T urbo T eut on 20 NO Z Z LES ISO O LIVA - O liv e ISO A R A N.
unigreen 31 unigreen s pa Tabe l l a eroga z i one in Li tr i / et ta ro Turbo Teut on GD C 2 0 get ti Lt . / ha spr eading r ate t able f or T urbo T eut on G DC 20 NO Z ZL ES ISO O LIVA - O liv e IS.
32 unigreen T AB. 3 T ABLE OF DELIVER Y OF NOZZLES FOR A T OMISERS T ABLE 4-5 T ABLES OF DELIVERY OF NOZZLES FOR HAND LANCES T ABLE OF DELIVER Y IN LITRES / MIN.
unigreen 33 T ABLE 7 T ABLE OF PROGRAMMED MAINTENANCE OPERA TION 8 h 50 h 300 h END OF SEASON Check the le vel and state of the oil 0 Check the accumulator pressure 0 Check the suction (hoses, pipes ,.
34 unigreen T AB.17B ALLOWED FITTINGS 2009 MO UN T ED AT O MISERS T YPE O F Pol y ethy lene T an k MA CH INE TA BLE 17 a P3 02 P4 0 2 P5 00 P 60 2 FITTI NG Nomi nal c apa c i ty ( L.
unigreen 35.
Descriptions, indicativ e illustrations, UNIGREEN S.P .A. reser ves the right to make v ar iations or modifications without prior wa r ning. via Rinaldi, 105 - 42124 Reggio Emilia - ITALY Tel. +39 0522 369811 Fax. +39 0522 369898 e-mail: info@unigreen-spa.
Ein wichtiger Punkt beim Kauf des Geräts Unigreen TurboTeuton P500 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Unigreen TurboTeuton P500 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Unigreen TurboTeuton P500 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Unigreen TurboTeuton P500 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Unigreen TurboTeuton P500 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Unigreen TurboTeuton P500 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Unigreen TurboTeuton P500 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Unigreen TurboTeuton P500. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Unigreen TurboTeuton P500 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.