uniden@ GRANT 40 Channel AM/SSB Mobile CB Radio OWNERS MANUAL ~----.
I' I . 'I -~ INTRODUCTION UNIDEN CORPORATION OF AMERICA has combined superb workmanship and modern styling with the very latest state-of-art circuitry to bring you the GRANT Citizens Band Trasoceiver. It has been especially designed to give you maximum performance and reliability.
INSTAllATION MOBILE STATION INSTALLATION Plan the location of the transceiver and microphone bracket before starting the installation. Select a location that is convenient for operation and does not interfere with the driver or passenger in the vehicle.
r - - ..- -,...-..--- POWER CORD CONNECTION: POSITIVE GROUND SYSTEM If you are operating on a positive ground system, connect the black DC power cord from the transceiver to the negative, or (-), battery terminal or other convenient point, and connect the red power lead to the chassis or vehicle frame, or (+) battery terminal.
... - ===-- --= OPERATING PROCEDURE TO RECEIVE: The G RANT operates on 40 AM channels, 40 Upper Side Band channels and 40 Lower Side Band channels. When you receive the SSB signal in the proper mode (.
I > '! ". "'-' . - ~- - = CONTROLS AND THEIR FUNCTIONS @ @ (J) @ @ @ 1. OFF/ON VOLUME: To turn the transceiver on, rotate this control clockwise past click. To turn the transceiver off, rotate the control counterclockwise past click.
- - - - --- 5. MIC GAIN: This control is used to adjust, as required, microphone input sensitivity for optimum amount of modulation in transmit. UNIDEN CORPO- RATION OF AMERICA citizen's band tra.
-- - ----.--. 13. CHANNEL INDICATOR: Light Emitting Diode(LED) indicates the channel number in use. 14. CHANNEL SELECTOR KNOB: This knob selects the desired channel for transmission and reception. All channels, except channel 9, may be used for communications between stations.
1= -~ - <--=====0 -==== --- 19. EXTERNAL SPEAKER JACK: The External Speaker Jack is used for remote receiver monitoring. The external speaker should have 8 ohm impedance and be rated to handle at least 4.0 watts. When the external speaker is plugged in, the internal speaker is automatically disconnected.
r GENERAL F .C.C. Type Number Channels Frequency Range Frequency Control Frequency Tolerance Frequency Stability Operating Temperature Range Microphone Input Voltage Current Drain Cabinet Dimensions Weight Antenna Connector Semiconductors Meter Indicators I .
<:::::C Frequency Response Output Impedance SSB Filter RECEIVER Sensitivity Selectivity Cross Modulation Image Rejection I.F. Frequency AM and SSB R F Gain Control Automatic Gain Control Squelch Noise Blanker Clarifier Range Audio Output Power Frequency Response Distortion Built-in Speaker External Speaker (Not Supplied) - .
r~ SERVICING YOUR TRANSCEIVER The technical information, diagrams and charts will be supplied upon request. It is the user's responsibility to see that this radio is operating at all times in accordance with the F .C.C. Citizens Radio Service regulations.
r .---- OPERATOR TROUBLESHOOTING Should be unit malfunction or not perform properly, the operator should perform the procedures il.dicated below: 1. If the transceiver is completely inoperative. * Check the power cord and fuse. 2. If trouble is experienced with receiving.
r=- -==::: NOTES -13 - I -- r f , ----- -.------- --.
r I . .) -~ '--'== - NOTES -14 - r f.
CIRCUIT DIAGR~M FOR GRANT [- I .c.- ""., ' r ~--------------------------------------------------------------------------- I TR' ZSCI615L TRZ Z$CI615L TR! ZSCI13OL 1RO ZSC94- TR5 ZSC94- TR6 ZSC90SAQ TRT 2SA"3PTRe ZSC94SAO TR9ZSCl615L FET 1 !S"SB TRIO ZSC.
BLOCK DIAGRAM FOR GRANT r ~ , I I I I I I I ~ DIMMER ANT I I I I I I I I I I L_- z '" ~-t: u I ~:i I I I I I ..J -- ,-+ : i ~--- ~ I I' - d'-°~ - + - -- ,I! I ,. n t - I I ~'" g ~ I -+-_.J ~ I ---~ t:. - I u; J I I I I I 1 5; .
r~ I ---=== - ~ uniden TWO-YEAR LIMITED WARRANTY I I . 'i WARRANTOR. UNIDEN CORPORATION OF AMERICA ("UNIDEN") ELEMENTS OF WARRANTY. UNIDEN warrants, for the duration of this warranty, its UNIDEN CB Product to be free from defects in materials and craftsmanship with only the limitation or exclusions set out below.
Ein wichtiger Punkt beim Kauf des Geräts Uniden GRANT (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Uniden GRANT noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Uniden GRANT - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Uniden GRANT reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Uniden GRANT erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Uniden GRANT besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Uniden GRANT verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Uniden GRANT. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Uniden GRANT gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.