Benutzeranleitung / Produktwartung UT362 des Produzenten Uni-T
Zur Seite of 30
1 UT361/UT362 OPERA TING MANUAL T able of Contents Title Page Overview Unpacking Inspection Rules For Safety Operation The Anemoscope Structure Display Symbols Setting Up The Anemoscopes Using The Ane.
2 UT361/UT362 OPERA TING MANUAL Overview Model UT361 and UT362 are an anemoscopes with high accurate sensitive resistance (NTC) as testing point. For fan axis, it uses a high durable ruby shaft in order to provide the accurate and stable measurement.
3 UT361/UT362 OPERA TING MANUAL Item 1 2 3 4 Description English Operating Manual USB Interface Cable (UT362) only Software (UT362) only 9 V Battery Software Qty 1 piece 1 piece 1 piece 1 piece W arning T o avoid electric shock or personal injury , read the "Rules for Safe Operation" carefully before using the Anemoscope.
4 UT361/UT362 OPERA TING MANUAL In the event you find any missing or damage, please contact your dealer immediately . In this manual, a W arning identifies conditions and actions that pose hazards to the user , or may damage the anemoscopes or the equipment under test.
5 UT361/UT362 OPERA TING MANUAL T o avoid possible electric shock or personal injury and to avoid possible damage to the anemoscopes or to the equipment under test, adhere to the following rules Do no.
6 UT361/UT362 OPERA TING MANUAL Use the specific authorized replacement part if you need to repair the anemoscopes Do not use the anemoscopes if the opening the housing cover Note the battery " + " and " - "pole when battery insert.
UT361/UT362 OPERA TING MANUAL The Anemoscope Structure (see figure 1) Fan Wind Speed Indicator Handle Secondary Display Primary Display Power Button Operational Button Main Unit 1 2 3 4 5 7 6 8 Figure.
8 UT361/UT362 OPERA TING MANUAL Display Symbols (see figure 2) Figure 2.
9 UT361/UT362 OPERA TING MANUAL Functional Signs Below table indicated for information about the functional sign operations. Number 1 2 3 4 5 6 7 8 9 Sign MAX MIN A VE READ REC NO.
10 UT361/UT362 OPERA TING MANUAL Number 10 1 1 12 13 14 15 16 17 18 Meaning Secondary Data Display Primary Data Display Wind Speed Unit - Foot Per Minute Wind Speed Unit - Meter Per Second Fahrenheit .
1 1 UT361/UT362 OPERA TING MANUAL Display Symbols (see figure 3) Figure 3 Function Key Description Power on / Power off Button Button 1 - This button function key switch is for wind speed measurement and wind count measurement. During wind speed measurement, press "UNIT" button m/s ft/min KNOTS Km/h MPH and vice versa.
UT361/UT362 OPERA TING MANUAL 12 Button 5 - Display the data download to USB port (For UT362 only) Description Button 2 - Press this button to choose In wind speed measurement: maximum reading, minimu.
13 UT361/UT362 OPERA TING MANUAL Function Key Description Button 7 - Press this button to activate the REC feature. Press and Hold this button to access data reading from database Button 8 - Press this button to erase the data records before power on.
14 UT361/UT362 OPERA TING MANUAL Setup up the Anemoscopes Press and hold button 9 (menu) to select feature setup. Press next button to go next feature sub-menu. A. USB setup Press button 8 from USBO USB1. Then set up is as the opening default B. Auto Switch Down Press button 8 from AP00 AP01 and store in after power off.
15 UT361/UT362 OPERA TING MANUAL This default keep it and no need to reset when power on. D. Master Reset LCD shows the DEF with flash. Y ou can reset your anemoscopes to the factory settings. Press button 2 of to the factory settings for USBO, APO1, 60S data clearing.
16 UT361/UT362 OPERA TING MANUAL Using the Anemoscopes Power On: Press "Power " button for a while to switch the anemoscopes on Wind Speed and Wind Count Feature Switch: Press VEL / FLOW button.
17 UT361/UT362 OPERA TING MANUAL Wind pipe input area: 1) Correct input the wind pipe area before wind count measurement 2) Set default area is one square meter after the entering wind count measurement. 3) Select the approiate wind count-measuring unit.
18 UT361/UT362 OPERA TING MANUAL Enter 1, ENTET Mean 1 LCD display " 1.000 " Enter 0, 0, 0, 1 Mean 0001 LCD display " 1.000 " Enter ., 0, 0, 1 Mean . 001 LCD display " 0.001 " ... ... ... In one area, it will probably to have a different input methods but finally it has one display: Data Input Range: 0.
19 UT361/UT362 OPERA TING MANUAL Data Storage Functions: 1) LCD display " No Data " if no data storage 2) LCD display " T ime " if database is full and cannot store any data in the current time. 3) Manual data storage: press button 7 to display the automatic data storage in LCD, also LCD displays REC and around 0.
20 UT361/UT362 OPERA TING MANUAL 5) Record Clearing Method 1: Press and hold button 8 until LCD appear CLR when power on. Method 2: Resume to factory setting (see function setting stuff) Press and hold button 7 to view the data records of wind speed measurement and wind count measurement.
Screw Wind Figure 4 Measuring For Wind Speed (Wind Count) (see figure 4) Note: before use, the wind speed is over 10m/s under 1 - 2 minutes duration. T o carry out anemoscopes, follow the following procedure: 1. Press on " Power " button until the anemoscopes on 2.
22 UT361/UT362 OPERA TING MANUAL 4. Use figure 4 to conduct wind speed measurement , it shows wind flow direction, but bear in mind W arning do not use it in opposite. A screw can fix on it. (Note: UNI-T will not provide this screw to the customer , the customer need to buy it separately) 5.
23 UT361/UT362 OPERA TING MANUAL Computer Connectivity (For UT362 only)(see figure 5) When use the anemoscopes model UT362 need to connect USB cable with the computer Connect the USB interface cable, .
24 UT361/UT362 OPERA TING MANUAL Maintenance A. Replacing The Battery T o avoid false reading, which could read to possible electronic shock or personal injury , replace the battery as soon as the battery indicator " " appears.
25 UT361/UT362 OPERA TING MANUAL 5) Rejoin the case bottom and the battery compartment and reinstall the screw . B. Cleaning Periodically wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. C. Service And Repairing This anemoscope is an auto calibration.
26 UT361/UT362 OPERA TING MANUAL 2) T ake out the battery when it is not using for a long time. 3) Do not use or store the Meter in a place of humidity , high temperature, explosive, inflammable and strong magnetic field.
27 UT361/UT362 OPERA TING MANUAL Range 2~10 m/s 10~30 m/s UT362 (3%+0.5) (3%+0.8) UT361 (3%+0.5) (3%+0.8) Accuracy T echnical Specification Wind Speed Measurement.
28 UT361/UT362 OPERA TING MANUAL T emperature Measurement T emperature Main Unit T emperature Sensor T emperature Range 0 ~40 32 ~ 104 0 ~40 32 ~ 104 UT362 3 4 3 4 UT361 3 4 3 4 Accuracy ** END **.
29 UT361/UT362 OPERA TING MANUAL This operating manual is subject to change without notice..
30 UT361/UT362 OPERA TING MANUAL.
Ein wichtiger Punkt beim Kauf des Geräts Uni-T UT362 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Uni-T UT362 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Uni-T UT362 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Uni-T UT362 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Uni-T UT362 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Uni-T UT362 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Uni-T UT362 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Uni-T UT362. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Uni-T UT362 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.