Commercial Refrigerator Service Manual Mega Top Salad Unit Model No: TST-72SD-30 TST-60SD-24 TST-48SD-18 TST-28SD-12 Sandwich Salad Unit Model No: TST-72SD TST-60SD TST-48SD TST-28SD Under counter Sal.
TABLE OF CONTENTS 1.FEATURE CHART 1-1. MEGE TOP SERIES Ⅰ. FRONT VIEW Ⅱ. SIDE VIEW 1-2. SANDWICH SERIES Ⅰ. FRONT VIEW Ⅱ. SIDE VIEW 1-3. UNDER COUNTER SERIES Ⅰ. FRONT VIEW Ⅱ. SIDE VIEW 2.WIRING DIAGRAMS 2-1.TST-72SD-30,TST-72SD 2-2.TST-60SD-24,TST-60SD 2-3.
1.FEATURE CHART 1-1. MEGE TOP series Ⅰ.FRONT VIEW Ⅱ.SIDE VIEW TST-72SD-30 TST-28SD-12 TST-60SD- 24 TST-48SD-18 9 16 19 17 18 12 13 14 21 15 22 11 10 20 1 2 3 4 6 7 8 1C O U N T E R T O P 2D O O R .
FEATURE CHART 1-2.SANDWICH Ⅰ.FRONT VIEW Ⅱ.SIDE VIEW TST-72SD TST-28SD TST-60SD TST-48SD 1C O U N T E R T O P 2 DOOR(L) 3 DOOR HANDLE(L) 4E V A P O R A T O R D U C T 5L O U V E R 6 MULLIO N 7S H E .
FEATURE CHART 1-3.Undercounter Ⅰ.FRONT VIEW TUR-28SD Ⅱ.SIDE VIEW TUR-72SD TUR-60SD TUR-48SD 1C O U N T E R T O P 2 DOOR(L) 3 DOOR HANDLE(L) 4E V A P O R A T O R D U C T 5L O U V E R 6 MULLIO N 7S .
2.WIRING DIAGRAMS 2-1.TST-72SD-30.TST-72SD. 2-2.TST-60SD-24.TST-6OSD..
WIRING DIAGRAMS 2-3.TST-48SD-18, TST-28SD-12, TST-48SD, TST-28SD, TUR-72SD, TUR-60SD, TUR-48SD, TUR-28SD.
3.PART DETAILS 3-1. COMPRESSOR COMPARTMENT 1)MEGE TOP&SANDWICH TST-72SD-30.TST-72SD TST-48SD-18.TST-48SD TST-60SD-24.TST-60SD TST-28SD-12.TST-28SD.
PART DETAILS 2)UNDER COUNTER TUR-72SD TUR-48SD TUR-60SD TUR-28SD.
PART DETAILS 3-2. DOOR DOOR GASKET 3-3.REFRIGERATION COMPARTMENT TEMPERATURE CONTROL & EVAPORATOR.
PART DETAILS EVAPORATOR FAN MOTOR THERMOSTAT.
4.MAIN COMPONENTS 1.COMPRESSOR(MEGE TOP&SANDWICH) PART NAME PART NO. HORSE CAPACITY TYPE OF INPUT MAKER CAE4456Y M729700100 1/2HP ~ CSIR ~ ~ CAE4456Y M729700100 1/2HP ~ CSIR ~ ~ SK1A1C-L2W M609700100 1/3HP ~ CSR ~ SAMSUNG HBL-27YE-1 M369700100 1/4HP ~ CSR ~ DAEWOO *COMPRESSOR(UNDER COUNTER) PART NAME PART NO.
5.TEMPERATURE CONTROL INSTRUCTION 5-1.HOW TO USE THE TEMPERATURE CONTROL 5-2.FUNCTION TABLE No Function Controlled Tempressor Compressor 1.The temperature can be changed by turning the dial knob Control Evap.Fan motor 2.Compressor is automatically turned on and off by thermostat.
72 60 48 28 Cabinet CABINET Assembly M279500200 1 CABINET Assembly M489500200 1 CABINET Assembly M609500200 1 CABINET Assembly M729500200 1 CASTER M726500100 5INCH MOVING 2222 SAME AS BEFORE CASTER M7.
PARTS LIST FOR MEGA TOP 72 60 48 28 HARNESS CAPACITOR (STARTING) M602700300 11 HARNESS CAPACITOR (RUNNING) M602700405 1 HARNESS CAPACITOR (RUNNING) M482700300 1 CONDENSER FAN MOTOR 3963328120 IS4420DWSN-2A 2111 SAME AS BEFORE POWER CORD M721300201 KKP-30(9.
PARTS LIST FOR MEGA TOP 72 60 48 28 LOUVER M275800103 SUS304-2B/0.023"(Thickness) 1 LOUVER M485800103 SUS304-2B/0.023"(Thickness) 1 LOUVER M605800104 SUS304-2B/0.
72 60 48 28 Cabinet CABINET Assembly S279500200 1 CABINET Assembly S489500200 1 CABINET Assembly S609500200 1 CABINET Assembly S729500200 1 CASTER M726500100 5INCH MOVING 2222 SAME AS BEFORE CASTER M7.
PARTS LIST FOR SANDWICH 72 60 48 28 HARNESS CAPACITOR (STARTING) M602700300 11 HARNESS CAPACITOR (RUNNING) M602700405 1 HARNESS CAPACITOR (RUNNING) M482700300 1 CONDENSER FAN MOTOR 3963328120 IS4420DWSN-2A 2111 SAME AS BEFORE POWER CORD M721300201 KKP-30(9.
PARTS LIST FOR SANDWICH 72 60 48 28 LOUVER M275800103 SUS304-2B/0.023"(Thickness) 1 LOUVER M485800103 SUS304-2B/0.023"(Thickness) 1 LOUVER M605800104 SUS304-2B/0.
72 60 48 28 Cabinet CABINET Assembly U279500200 1 CABINET Assembly U489500200 1 CABINET Assembly U609500200 1 CABINET Assembly U729500200 1 CASTER M726500100 5INCH MOVING 2222 SAME AS BEFORE CASTER M7.
PARTS LIST FOR UNDERCOUNTER 72 60 48 28 DRAIN PAN M729300100 PP 1 1 1 HARNESS RELAY M272700304 1 HARNESS RELAY M602700503 1 1 1 DRAIN PIPE M724400500 STS304/ODΦ6.35X0.5T 1111 CONDENSER CONNETCOR PIPE (A) M604400301 ODΦ7.94X0.5T 1 1 1 CONDENSER CONNETCOR PIPE M274400104 ODΦ7.
7.REPLACEMENT OF MAIN COMPONENTS 7-1.REPLACING DOOR A.Unscrew the top hinge B.Lift the door.
REPLACEMENT OF MAIN COMPONENTS 7-2.REFRIGERATION COMPARTMENT PARTS A.Disassemble the evaporator fan duct assembly B.Disassemble the evaporator fan motor.
REPLACEMENT OF MAIN COMPONENTS C.Disassemble the pan duct middle(MEGE TOP&SANDWICH) D.Disassemble the evaporator duck E.Remove the thermostat & sensor.
REPLACEMENT OF MAIN COMPONENTS F.Remove the evaporator coil.
REPLACEMENT OF MAIN COMPONENTS 7-3.COMPRESSOR COMPARTMENT PARTS A.Disassemble the rear grill B.Disassemble the cable tie.
REPLACEMENT OF MAIN COMPONENTS C.Disassemble the condesing unit Unscrew two screws as above Pull out the condensing unit D.Disassemble the condenser fan motor.
REPLACEMENT OF MAIN COMPONENTS 7-4.REPLACING THE EVAPORATOR & EVAPORATOR FAN MOTOR. A-1.Remove the pan(MEGE TOP&SANDWICH) B-1.Remove the Pan support frame(MEGE TOP&SANWICH).
REPLACEMENT OF MAIN COMPONENTS C.Unscrew the screw located on both sides and top of the evap duct assamble fixture D.Unscrew the screws located on top and bottom of the pan duct middle.
REPLACEMENT OF MAIN COMPONENTS E.Take out the pan duct middle through the upper the upper hole. (MEGE TOP&SANDWICH) * UNDER COUNTER DOESN'T HAVE THE PAN DUCT.
REPLACEMENT OF MAIN COMPONENTS G.And then, you can replace fan motor, evaporator coil and thermo sensor..
8.REPLACEMENT OF MAIN COMPONENTS(UNDERCOUNTER) 8-1.REFRIGERATION COMPARTMENT PARTS A.Disassemble the counter top of undercounter.
REPLACEMENT OF MAIN COMPONENTS(UNDERCOUNTER) B.Iisassemble the evaporator fan duct assembly C.Disassemble the evaporator duct.
REPLACEMENT OF MAIN COMPONENTS(UNDERCOUNTER) D.Disassemble the evaporator fan motor E.Remove the thermostat&Sensor.
Ein wichtiger Punkt beim Kauf des Geräts Turbo Air TST-60SD-24 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Turbo Air TST-60SD-24 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Turbo Air TST-60SD-24 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Turbo Air TST-60SD-24 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Turbo Air TST-60SD-24 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Turbo Air TST-60SD-24 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Turbo Air TST-60SD-24 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Turbo Air TST-60SD-24. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Turbo Air TST-60SD-24 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.