Benutzeranleitung / Produktwartung SU10K des Produzenten Tripp Lite
Zur Seite of 17
1 Copyright © 2001 Tripp Lite. All rights reserved. SmartOnline TM is a registered trademark of Tripp Lite. 1111 W. 35th Street Chicago, IL 60609 USA Customer Support: (773) 869-1234 Application Services: (773) 869-1236 www.
2 Safety This manual contains important instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite SmartOnline UPS Systems. UPS Location W arnings • Install your UPS indoors, away from excess moisture or heat, dust or direct sunlight.
3 Contr ol P anels Familiarize yourself with the location and function of the front and rear panel features before installing and operating your UPS. 1. “ON/OFF” Switch: This momentary rocker switch turns the UPS System’s inverter ON and OFF. 2.
4 SU10KPM SU6K SUBP SU10KBP Rear P anels ON LINE MODE ECONOMY MODE ON LINE MODE ECONOMY MODE 1 14 3 6 10 11 2 4 5 8 7 9 16 15 18 13 5 12 17 1 14 3 6 10 11 2 4 5 8 7 9 16 15 18 13 17 12 2 5 12 5 L1 L2.
5 1. Manual Bypass Switch: This red and yellow dial is used in one step of putting the UPS in "BYPASS” mode, which must be done before performing any maintenance on the UPS with the connected load supported. (See page 12 for step-by-step instructions for going into "BYPASS.
6 INVERTER OPERA TION DIP SWITCH SETTINGS (SU10KPM SHO WN) Using a small tool, set the four Inverter Opera- tion DIP Switches (located on the rear panel of your UPS, see pg. 4-5 for location) to match your input voltage, input frequency and desired operational mode.
7 UPS LOCA TION Move your UPS over short distances using its wheels. Stabilize the UPS by releasing the stabilizers on each side of the unit. NOTE: Do not stack the UPS Systems or external battery packs.
8 EXTERNAL B A TTER Y P A CK CONNECTION (SU6K: Optional; SU10K: Required) Since SU6K models contain internal batteries, connecting external battery packs (to extend runtime) is optional. SU10KPM models, however, do not have internal batteries and require an external battery pack connection to a SU10KBP or a SUBP.
9 B A TTER Y CONDITION VERIFICA TION When the UPS is operating from battery power, the alarm and LCD Display will both alert you to the UPS battery’s charge condition.
10 SELF-TESTING When you turn the UPS ON, it will perform a brief (about 25 second) self-test. See figure below for display sequence.* *Note: If starting from battery, the BATTERY LED will be lit and the I/P and BYPASS LEDs will not.
11 Operation (Special Conditions) OPERA TION ON BYP ASS—V OL T A GE OUT OF RANGE While in Bypass Mode, the UPS monitors the input voltage, which on Bypass equals the output voltage.
12 OPERA TION UNDER SHUTDO WN Your UPS will shut down and the LCD will display a message if it detects one of the following conditions. Note: For all conditions, the “Input,” “Output” and “Bypass” LEDs will be illuminated.
13 RS-232 INTERF A CE This female DB9 port connects your UPS via an RS-232 cable to a workstation or server equipped with Tripp Lite software. The port uses RS-232 communications to report UPS status and power conditions.
14 DR Y CONT A CT INTERF A CE: This female DB9 contact-closure port allows your UPS to send contact-closure signals to indicate that it is on battery back-up mode and if its batteries are running low. The port can also receive a remote shutdown signal.
15 Ser vice Service Your SmartOnline UPS is covered by the 2-year limited warranty period described below. A variety of service contracts is also available from Tripp Lite, including start- up service contracts and 3- to 5-year SafeSure on-site service contracts.
16 F unction Block Diagram LEDS LCD TO RS-232 AS-400 DRY CONTACT ACCESSORY SLOT REPO AC INPUT BREAKER AC INPUT SURGE PROTECTOR INPUT FIL TER AC TO DC CONVERTER DC TO AC INVERTER STA TIC BYPA S S SWITC.
17 Specifications (Note: Excluding isolation transformer) Model SU6K SU10K Input Input Voltage 156V~280V Single Phase 156V~280V Single Phase Input Frequency 50/60 Hz ± 3 Hz 50/60 Hz ± 3 Hz (selectable, pg. 7) (selectable, pg. 7) Input Current 32A 50A Inrush Current <150A <200A Power Factor (Full Load) >0.
Ein wichtiger Punkt beim Kauf des Geräts Tripp Lite SU10K (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Tripp Lite SU10K noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Tripp Lite SU10K - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Tripp Lite SU10K reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Tripp Lite SU10K erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Tripp Lite SU10K besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Tripp Lite SU10K verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Tripp Lite SU10K. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Tripp Lite SU10K gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.