Benutzeranleitung / Produktwartung RKP002Z des Produzenten Toshiba
Zur Seite of 21
E6581277 c Remote Keypad Instruction Manual RKP002Z NOTICE 1. Make s ure that this instruction m anual is delivered to the end user of Rem ote Key pad. 2. Read this m anual before installing or operating the Rem ote Keypad. Keep it in a safe plac e for r eference.
E6581277 c - 1 - Safety precautions On the inverter and in its ins truction m anual, im portant inf orm ation is contained f or preventing inj uries to users, dam ages to as sets, and f or proper us e of the device.
E6581277 c - 2 - Limitation of use Safety precaution Never use this unit with any device other than TOSVERT ser ies inverters . Doing so m ay cause an accident. Handling in general Danger Never Disassemble Never disass em ble, modif y or repair the product.
E6581277 c - 3 - Operation s Danger Prohibited Do not apply a dropping shock or other physical shoc ks. Otherwise, dam age or m alf unction will result. Do not pull on the cable and connector It may cause dam age or error . Even if this pr oduct is deactivated by an unusual event such as tripping, an oper ating error, power outage, etc.
E6581277 c - 4 - Preface Thank you for purc hasing Rem ote Keypad (RKP002Z ) f or T OSVERT series inverters . Using this product, panel operation, dis play and adjus tment of the inverter c an be rem otely controlled from up to 5 meter s away .
E6581277 c - 5 - Table of contents 1. Overview ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 6 2.
E6581277 c - 6 - 1. Ov erv iew The f ollowing seven functions are available with Remote Keypad. 1. Function to ser ve as rem ote operation panel. Remote Keypad can be used as a r emote oper ation panel for the inverter .
E6581277 c - 7 - 2. Names and functions of main p art s The drawings below show nam es and f unctions of main par ts. Front view 8((8 COPY MODE RUN PRG MON EASY Hz % RUN A STOP B MODE ESC ENT EASY Hz la mp *1 Lights when displayed values are Hz. % lamp *1 Lights when displayed values are %.
E6581277 c - 8 - Operation k eys and their f unctions in “COPY MODE” The operation k ey’s functions in “ COPY MODE” are explained in the f ollowing table.
E6581277 c - 9 - 4. Functions in det ail Remote Keypad can be used as r emote oper ation panel (“REMOT E KEYPAD MODE”) or param eter back -up device (“CO PY MODE”). W hen the “COPY MODE” lam p is lit when turning power on, Remote Key pad operates in “CO PY MODE”, otherwise in “REMOT E KEYPAD MODE”.
E6581277 c - 10 - 4.3.1. Copying function “ copy ” The data s tored in a m emor y can be copied to another mem ory selected fr om among f our mem ories (the inverter's m em ory and Remote Keypad mem ories A, B, and C) . Remote Keypad can not be used to copy parameters from one inverter to another inverter of a diff erent series.
E6581277 c - 11 - 4.3.2. Simple copying function The data stored in the m em ory A, B or C of Remote Keypad can be copied to the inverter's m em ory with simple operation of two keys to selec t one of the m em ories A, B and C. Us e this func tion to set the sam e param eters to m ore than two inverters.
E6581277 c - 12 - 4.3.3. Comparing function “ comp ” This f unction enables the operator to com pare data stored in two mem ories select ed from am ong four m em ories (the inverter ’s m em ory and Remote Keypad m em ories A, B, and C) as well as to search f or param eters that dif fer from each other.
E6581277 c - 13 - 4.3.4. Memory protection function “ prot ” The m em ory protection function pr otects the selec ted mem or y from being overwritten. W hen this func tion is initiated copying data to the mem ory is prohibited. Reading the m emo ry data is perm itted.
E6581277 c - 14 - 4.3.5. Memory init ializing funct ion clr A selected one of the m em ories either m em ory A, B, C of Rem ote Key pad is enable to be initialized with this function. In addition, all mem ories including sy stem m em ory of Remote Keypad is also enable to be initialized.
E6581277 c - 15 - 4.3.6. Remote Keypad parameter editing function This function allows the user to edit the param eters of Remote Keypad. Remote Keypad paramet er list Title Func tion Description f-01 Softwa re versi on displaying Display shows the software vers ion of Rem ote Keypad.
E6581277 c - 16 - 5. Before making a serv ice call If a problem aris es, pleas e see the following tr ouble-shooting tables. If the problem c an not be solved, please contac t a Tos hiba distributor.
E6581277 c - 17 - 5.3. Warning indi cations W arning indications : Indicat ed by flashing LED display. W arning Code Problem and Solutions prot The target memory to copy data or to initialize is write protected. C opying any data to the memory or initializing the memory cannot be executed.
E6581277 c - 18 - 6. Outline draw ing Following is the outline drawing of Remote Keypad (Uni t: mm).
E6581277 c - 19 - Mounting Mount Remote Keypad on the front of the panel board as illustr ated below. On the fr ont of the panel boar d, cut the area shown below f or m ounting Remote Keypad. Then, f ix Remote Keypad on the panel board with the mounting scr ews (M3 x 12) supplied as acc essories.
E6581277 c - 20E - 7. S pecifications Item Specific ations Part num ber RKP002Z Applicable m odel Model with either an RS485 (2- wire ty pe) connec tor or a com mon serial connector ( optional) with a baud rate of 9600, 19200 or 38400bps.
Ein wichtiger Punkt beim Kauf des Geräts Toshiba RKP002Z (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Toshiba RKP002Z noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Toshiba RKP002Z - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Toshiba RKP002Z reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Toshiba RKP002Z erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Toshiba RKP002Z besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Toshiba RKP002Z verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Toshiba RKP002Z. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Toshiba RKP002Z gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.