Page 2 Manual Print History Manual Print History Manual Print History Manual Print History Manual Print History The print histor y shown belo w lists the printing dates of all revisions and addenda created for this manual. The revision level letter increases alphabetically as the manual undergoes subsequent updates .
Page 3 T able of Contents 1.0 GENERAL INFORMA TION .................................................... 5 1.1 F e atures ................................................................................................................. .5 1.2 Specifica tions .
Page 4.
Page 5 General Information SECTION 1 The Hastings Model 40 P o w er Supply is a combina tion po w er supply and digital readout monitor, for up to four Hastings Flow Instruments having the model number prefixes of HFM, ST , or FST and up to 2 of the HFM-D series.
Page 6.
Page 7 Installation and Operation SECTION 2 This section is designed to assist you in getting a new po wer supply into opera tion as quickly and easily as possible. Please read the following v ery thoroughly before attempting to install the instru- ment.
Page 8 2.3 Output V oltage: The output of the flow instrument is a 0-5.00 VDC signal propor tional to the flow ra te. The output is sent to the display and is av ailable at terminals at the rear of the Model 40 P ower Supply . It is recommended that the load resistance be no less than 2K Ohms.
Page 9 2.5 Operation: 2.5.1 Displa 2.5.1 Displa 2.5.1 Displa 2.5.1 Displa 2.5.1 Displa y y y y y If the pow er supply was purchased with the flow instruments, the pow er supply will be already set up so that the display reads directly in the units of flo w to be monitored.
Page 10 2.5.5 Fuse 2.5.5 Fuse 2.5.5 Fuse 2.5.5 Fuse 2.5.5 Fuse The fuseholder is mounted on the low er right-hand corner of the back panel. T o remove the fuse, insert a screwdriver into the slot and turn counterclockwise 1/4 turn. Replace the fuse with a 250 volt 1/4 amp Slo-Blo<190> fuse, 1/4" x 1-1/4".
Page 11 Calibration and Adjustments SECTION 3 This section contains instr uctions to change the configuration of the pow er supply from the w ay it was set up at the factory . 3.1 Range Change: Since the display uses a 3-1/2 digit LCD , the highest number that can be displayed is 1999.
Page 12 or supply a 5-volt dumm y signal to the FLO W -OUT terminals on the back panel. T urn the DIS- PLA Y -ADJUST potentiometer for the channel to be set until the display reads the desired full scale reading. The DISPLA Y -ADJUST potentiometer s are located on the PC board near the front/center as shown in Fig3.
Page 13 calculated b y comparing ratios of their respective hea t capacities. These ratios hav e been calcula ted and are tabulated on a chart on page 16 of this manual as THR conv ersion factors. These factors are used as written only when an instr ument calibrated for AIR AIR AIR AIR AIR is being used to measure the flow of a different gas.
Page 14 3.2.2 Calcula 3.2.2 Calcula 3.2.2 Calcula 3.2.2 Calcula 3.2.2 Calcula tion of Cor tion of Cor tion of Cor tion of Cor tion of Cor rection F rection F rection F rection F rection F actor actor .
Page 15 T roubleshooting SECTION 4 This section contains a troubleshooting guide to help locate and repair failed components . This troubleshooting guide is designed as a general reference only , and will not co v er ev ery possible component failure.
Page 16 Check these voltages prior to using the troubleshooting char t. TP-6 is one lead of R27 and should be 2.00 VDC. The flow signals sent b y flowmeters on channels 1 - 4 can be accessed by test points on one lead of C7 thru 10 respectiv ely in the left rear of the main PC board.
Page 17 W arranty SECTION 5 5.1 W ar ranty Repair P olicy Hastings Instruments war rants this product for a period of one year from the date of shipment to be free from defects in material and workmanship . This warranty does not apply to defects or failures resulting from unauthorized modification, misuse or mishandling of the product.
Ein wichtiger Punkt beim Kauf des Geräts Teledyne Power Supply (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Teledyne Power Supply noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Teledyne Power Supply - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Teledyne Power Supply reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Teledyne Power Supply erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Teledyne Power Supply besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Teledyne Power Supply verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Teledyne Power Supply. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Teledyne Power Supply gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.