PS280 & PS283 User Manual i T able of Contents General Safety Summary iii . . . . . . . . . . . . . . . . . . . . . . . . . . . . Getting Started 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Preparing the Power Supply for Use 2 .
T able of Contents ii PS280 & PS283 User Manual List of Figures Figure 1: Line V oltage Selectors, Power Input, and Fuse Locations 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 2: PS280 or PS283 Front Panel 4 . . . . . . .
PS280 & PS283 User Manual iii General Safety Summary Review the following safety precautions to avoid injury and prevent damage to this product or any products connected to it. Injury Precautions Use Proper Power Cord T o avoid fire hazard, use only the power cord specified for this product.
General Safety Summary iv PS280 & PS283 User Manual Do Not Operate in Wet/Damp Conditions T o avoid electric shock, do not operate this product in wet or damp conditions. Do Not Operate in Explosive Atmosphere T o avoid injury or fire hazard, do not operate this product in an explosive atmosphere.
General Safety Summary PS280 & PS283 User Manual v CAUTION. Caution statements identify conditions or practices that could r esult in damage to this pr oduct or other pr operty . T erms on the Product These terms may appear on the product: DANGER indicates an injury hazard immediately accessible as you read the marking.
General Safety Summary vi PS280 & PS283 User Manual.
PS280 & PS283 User Manual 1 Getting Started The T ektronix PS280 or PS283 Laboratory DC Power Supply is a multifunction bench or portable instrument. This regulated power supply provides a fixed 5 V output for powering logic circuits and two variable outputs for a wide variety of test and experimental uses.
Getting Started 2 PS280 & PS283 User Manual Preparing the Power Supply for Use Check the following items prior to operating the Laboratory DC Power Supply for the first time (see Figure 1 for locations of items 1 through 3): 1 3 2 Figure 1: Line V oltage Selectors, Power Input, and Fuse Locations CAUTION.
Getting Started PS280 & PS283 User Manual 3 occurs. Refer to Appendix C: Replaceable Parts on page 33 for fuse part numbers. W ARNING. T o pr event electrical shock, connect the power cor d to a pr operly gr ounded power sour ce. The outside (ground) of this connector is connected thr ough the equipment to the power sour ce gr ound.
Getting Started 4 PS280 & PS283 User Manual Front Panel Figure 2 shows the front-panel controls, connectors, and indicators with brief descriptions following the figure. 13 4 5 6 8 22 19 18 15 12 1 1 13 17 21 9 27 20 16 14 10 Figure 2: PS280 or PS283 Front Panel 1.
Getting Started PS280 & PS283 User Manual 5 3. AMPS Indicator . Lights when AMPS is selected with the AMPS/VOL TS switch for the left variable power supply . 4. VOL TS Indicator . Lights when VOL TS is selected with AMPS/VOL TS switch for the left variable power supply .
Getting Started 6 PS280 & PS283 User Manual 13. Output T erminals. These terminals for the left, variable power supply allow you to plug in the test leads as follows: H The red terminal on the right is the positive polarity output terminal. It is indicated by a + sign above it.
Getting Started PS280 & PS283 User Manual 7 17. Output T erminals. These terminals for the right, variable power supply allow you to plug in the test leads as follows: H The red terminal on the right is the positive polarity output terminal. It is indicated by a plus (+) sign above it.
Getting Started 8 PS280 & PS283 User Manual T urning On the Instrument After you have ensured that the PS280 or PS283 is set up for the proper line voltage and has the proper fuse (refer to Pr eparing the Power Supply for Use on page 2), you are ready to turn it on.
PS280 & PS283 User Manual 9 Reference This section tells how to set the PS280 or PS283 current limit. It also explains the constant voltage/constant current crossover characteris- tic of the instrument.
Reference 10 PS280 & PS283 User Manual V O Maximum Output V oltage Constant Current Range Constant V oltage Range Crossover Point I O Maximum Output Current Figure 3: Constant V oltage/Constant Cu.
Reference PS280 & PS283 User Manual 11 3. Rotate the V OL T AGE knob away from zero sufficiently to light the C.C. indicator . 4. Set the meter selection switch to AMPS so that the LED display shows the current. 5. Adjust the CURRENT knob for the desired current limit.
Reference 12 PS280 & PS283 User Manual In stacked mode, you connect the negative output terminal of one variable power supply to the positive output terminal of the other . The stacked configuration allows you to test a circuit requiring between 30 and 60 V .
Reference PS280 & PS283 User Manual 13 4. Plug one of the test leads into the positive output terminal. 5. Plug the other test lead into the negative output terminal. 6. Press POWER to turn of f the PS280 or PS283. 7. Clip the positive test lead to the positive pole of your device.
Reference 14 PS280 & PS283 User Manual 5V FIXED 3A GND GND SLA VE MASTER Load 2 Load 1 0 to 2 A (PS280) 0 to 1 A (PS283) –5 V 3A –5 TO +25 V Load 3 0 to 2 A (PS280) 0 to 1 A (PS2.
Reference PS280 & PS283 User Manual 15 4. Set both variable supply CURRENT controls to midrange. 5. Set the AMPS/V OL TS switches for both power supplies to display volts. 6. T urn on the POWER to the PS280 or PS283. The display should read 0 V for both variable power supplies.
Reference 16 PS280 & PS283 User Manual T o test a circuit in a independent ground-referenced split application mode, follow these steps: 1. T urn the POWER off to the PS280 or PS283. 2. Connect the outputs as shown in Figure 6. 3. Set both variable supply VOL T AGE controls to the minimum setting.
Reference PS280 & PS283 User Manual 17 Figure 8 shows the configuration for three ground-referenced positive power supplies. Load 3 0 to 30 V 0 to 2 A (PS280) 0 to 1 A (PS283) Load 2 0 to 30 V 0 t.
Reference 18 PS280 & PS283 User Manual 5V FIXED 3A GND GND SLA VE MASTER Load 2 Load 1 –5 V 0 to +60 V Figure 9: Independent Positive Stacked Application T o test a circuit in the independently stacked mode, follow these steps: 1. T urn the POWER off to the PS280 or PS283.
Reference PS280 & PS283 User Manual 19 Figure 10 shows a stacked application in which you have a 0 to –60 V output from the variable power supplies and a +5 V output from the FIXED power supply .
Reference 20 PS280 & PS283 User Manual T racking Modes There are two tracking modes in which you can operate the PS280 or PS283: series and parallel. Series. In series mode, the positive output terminal of the master variable power supply is internally connected to the negative output terminal of the slave power supply .
Reference PS280 & PS283 User Manual 21 1. T urn the POWER off to the PS280 or PS283. 2. Connect the outputs as shown in Figure 12. 5V FIXED 3A GND GND SLA VE MASTER Load 1 0 to +60 V INTERNAL Figure 12: Series T racking Application 3.
Reference 22 PS280 & PS283 User Manual NOTE . In series tracking mode, the curr ent flowing through the two supplies must be equal. Ther efor e, the maximum curr ent limit is the lower of the values set by the two curr ent contr ol knobs. 7. T urn on the POWER to the PS280 or PS283.
Reference PS280 & PS283 User Manual 23 MASTER SLA VE Figure 13: Parallel T racking Inside the PS280 or PS283 T o test a circuit in the parallel tracking mode, follow these steps: 1. T urn the POWER off to the PS280 or PS283. 2. Connect the outputs as shown in Figure 14 on page 24.
Reference 24 PS280 & PS283 User Manual 5V FIXED 3A GND GND SLA VE MASTER Load 1 0 to +30 V INTERNAL 0 to 4 A (PS280) 0 to 2 A (PS283) Figure 14: Parallel T racking Application 7. Adjust the output voltage to the desired level using the master V OL T AGE knob.
PS280 & PS283 User Manual 25 Appendix A: Specifications T able 1: Physical Characteristics Dimension Measurement Width 255 mm (10.0 in) Height 145 mm (5.
Appendix A: Specifications 26 PS280 & PS283 User Manual T able 3: Operational Characteristics (Cont.) Characteristic Measurement Line Regulation (CC) 0.2% +3 mA Load Regulation (5 V) 0.2% Load Regulation (CV) 0.01% +3 mV (rating current 3A ) 0.
Appendix A: Specification s PS280 & PS283 User Manual 27 T able 4: Electrical Characteristics Characteristic Measurement Line voltage 90 to 1 10 108 to 132 198 to 242 216 to 250, all V AC at 50–.
Appendix A: Specifications 28 PS280 & PS283 User Manual.
PS280 & PS283 User Manual 29 Appendix B: Maintenance This appendix provides information for the basic maintenance of the PS280 or PS283 Laboratory DC Power Supply . Cleaning T o clean the Laboratory DC Power Supply , use a soft cloth dampened in a solution of mild detergent and water .
Appendix B: Maintenance 30 PS280 & PS283 User Manual T roubleshooting Electronic maintenance on the power supply must be performed by a trained technician. However , an operator can perform some basic and routine maintenance. Perform the following steps to isolate the fault: 1.
Appendix B: Maintenance PS280 & PS283 User Manual 31 5. V erify that the line settings on the rear panel match the line voltage. Do they? Y es Go to step 7. No Go to step 6. 6. Reset the line settings. Refer to Pr eparing the Power Supply for Use on page 2.
Appendix B: Maintenance 32 PS280 & PS283 User Manual.
PS280 & PS283 User Manual 33 Appendix C: Replaceable Parts Replaceable parts may be ordered directly from your authorized T ektronix dealer . Standard Accessories The following items are shipped w.
Appendix C: Replaceable Parts 34 PS280 & PS283 User Manual The following power cords are available: T able 8: Accessory Power Cords Plug Configuration Normal Usage T ektronix Part Number North Ame.
Ein wichtiger Punkt beim Kauf des Geräts Tektronix PS283 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Tektronix PS283 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Tektronix PS283 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Tektronix PS283 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Tektronix PS283 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Tektronix PS283 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Tektronix PS283 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Tektronix PS283. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Tektronix PS283 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.