Benutzeranleitung / Produktwartung iQM Series des Produzenten TDK
Zur Seite of 15
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 1/15 Supere ta™ iQ M Seri es DC/DC Pow er Mo dules 48V Input, 1.
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 2/15 Ordering infor mation: Product Ident.
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 3/15 Mechanical Sp ecifica tion : Dimensions are in mm [in]. Unless otherwise specified to lerances are: x.
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 4/15 A bsolute Maximum Ratings : Stress in excess of Absolute Maximum Ratings may caus e per manent dam age to the device.
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 5/15 Electrical D ata: iQM48070 A015V-000 through -009: 1.5 V, 70 A Output Characteri stic Mi n Ty p M ax Unit Notes & Conditions Output Voltage Initial Set point 1.
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 6/15 Electrical C haracte ristics: iQ M 48070A015V-000 thro ugh -009: 1.5V, 70 A Output Efficienc y vs.
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 7/15 Electrical Ch aracteris tics (continued) : iQ M 48070A015V-000 thro ugh -009: 1.5V, 70 A Output Output Current Li m it Characteristics vs.
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 8/15 Thermal Performance: iQM48070 A015V-000 thro ugh -009: 1.5V, 70 A Output Maximum output current vs .
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 9/15 Wind Tunnel Test Setup Figure Dimensions are in millimeters and (inches).
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 10/15 perform ance page f or the po wer module of interest.
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 11/15 Operating Informatio n: Over-Curre nt Protection: The po wer modules have curr ent lim it protection t o protect th e module during o utput over load and shor t circuit co nditions.
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 12/15 Vin(-) On/ Off Vin (+) On/Off Circu.
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 13/15 Sense(+) Trim Vout(-) Sense(-) Vout.
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 14/15 nominal input, f ull load, an d T a = 40 ˚ C using the Telc ordia T R-332 issu e 6 calc ulation method.
Data S heet: Supereta TM iQ M Serie s – Single O utput Qua rter B rick ©2004-2006 T DK Innoveta In c. iQM 1.5V/70A Datasheet 8/4 /2006 ℡ ( 877 ) 498-0099 15/15 Safety Con sideration s: For saf et.
Ein wichtiger Punkt beim Kauf des Geräts TDK iQM Series (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie TDK iQM Series noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für TDK iQM Series - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von TDK iQM Series reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über TDK iQM Series erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon TDK iQM Series besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von TDK iQM Series verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit TDK iQM Series. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei TDK iQM Series gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.