Benutzeranleitung / Produktwartung blu2i des Produzenten TDK
Zur Seite of 36
blu 2i Module User Guide The information contained in this document is subject to change without notice. TDK S ystems Europe makes no warranty of any kind with regard to this material including, but not lim ited to, the implied warranties of merchant ability and fitness for a particular purpose.
Contents BEFORE YOU BEGIN .................................................................................................................................................................... 3 S AFETY G UIDELI NES .....................................
Before Y ou Begin Congratulations on your purchase of the TDK Systems blu 2i Module. The Module is designed to be built into a device and to provide a simple, low cost Bluetooth interface. The modul e is designed to integrate with a wide range of applications and platforms with a simple electrical and software interface using AT commands.
Functions 1 The blu 2i Module contains a complete Bluetooth interface and requires no further hardware to implement full Bluetooth communication. The module has an integrated, high perform ance antenna together with all RF and Baseband circuitry, it interf aces to the host over a straight forward serial port using AT comm ands.
Application Interface 2 The blu 2i Module is equipped with a 40-pin 0.5mm pitch board to board connector that connects to the application platform. Electrical and mechanical characteristics of the bo ard-to-board connect or are specified in Chapter 3.
blu 2i Module Application UART_TX /RXD UART Interface RS232 Interface UART_RX /TXD UART_CTS /RTS UART_RTS /CTS UART_DTS /DTR UART_DTR /DSR UART_DCD /DCD UART RI / RING Figure: UART interfaces 2.2 Power Supply The power supply for the blu 2i Module has to be a single voltage source of Vcc= 3.
example when the supply voltage to the module experiences a Brown- Out (momentary dip in the supply vo ltage level), or a rapid power cycle i.e. the power is switched off and th en on within 1second, there is a possibility that the module can ent er an unknown state of operation.
2.4 SPI Bus The module is a slave device that uses terminals SPI_MOSI, SPI_MISO, SPI_CLK and SPI_CSB. This interf ace is used for program firmware update.
Electrical specification of the interface 3 The Hirose DF12C board to board connector on the module is a 40 way double-row receptacle. The pin allocation is as follows: Pin Signal Description Pin Signal Description 1 Analogue 0 1.8v Max 2 GPIO1 I/O for Host 3 Analogue 1 1.
Notes: • UART_RX, UART_TX, UART _CTS, UART_RTS, UART_RI, UART_DCD and UART_DSR are all 3.3v level logic. For example, when RX and TX are idle they will be sitting at 3.3V. Conversely for handshaking pins CTS, RTS, R I, DCD, DSR a 0v is treated as an assertion.
3.1 Electric Characteristics Function Signal Name Pin No I/O Signal level Comments Power Supply Vcc 29 I 3.6V to 6V Ityp = 50mA GND 11, 15, 18, 30, 36, 38 6 Ground terminals to be attached in parallel RS232 Interface UART_TX 21 O V OL max=0.2V V OH min=2.
V IH min=2.10V V IH max=3.7V PCM Interface PCM_CLK 20 I or O O/P : V OL max=0.2V V OH min=2.8V I/P : V IL max=0.8V V IH min=2.10V V IH max=3.7V If unused keep pins open PCM_IN 22 I V IL max=0.8V V IH min=2.10V V IH max=3.7V PCM_SYNC 24 I or O O/P : V OL max=0.
Physical Characteristics 4 4.1 Mechanical Dimensions 13 of 36.
4.2 Mounting the blu 2i Module onto the application platform There are many ways to pro perly install the Module in a host device. An efficient approach is to mount the PCB to a frame, plate, rack or chassis. Fasteners can be M1.8 or M2 screws plus suitable washers, circuit board spacers, or customiz ed screws, clamps, or brackets in 2.
Mating headers from Hirose are available in different stacking heights. Details are available at: http://www.hirose.co.jp/cat2002e/500/e53700036.pdf Item Part number Stacking height HRS number Headers DF12 series DF12(3.5)-40DP- 0.5V(81) 3.5mm CL537-0032-4- ** DF12(4.
Electrical and radio characteristics 5 5.1 Absolute Maximum ratings Absolute maximum ratings for supply voltage and voltages on digital and analog pins of the modul e are listed below. Exceeding these values will cause permanent damage. Minimum Maximum Peak current of power supply 0mA 100mA Voltage at digital pins -0.
being transferred and when data is be ing transferred at the maximum rate possible. The operating mode can best be described by stating the AT commands required to enter that mode. In additi on, there are certain S Registers which have a direct impact on pow er consumption, which are described next.
Baud rate 9600 38400 115200 460800 3.6V 3.20 3.20 3.20 3.20 Current per LED 5.0V 5.30 5.30 5.30 5.30 Baud rate 9600 38400 115200 460800 3.6V 1.60 1.80 1.96 3.00 Idle Mode, S512=1 5.0V 2.00 2.10 2.30 3.40 3.6V 59.00 59.00 59.00 59.00 Wait for Connection Or Discoverable Mode, AT+BTP S508=S510=640, S509=S511=320 5.
It is possible to reduce the duty c ycle down to as low as 0.5% at the expense of response time. The resp onse time can be specified via S Registers 508 and 510 fo r page and inquiry re spectivel y, where the worst case response time can be as high as 2.
contacted during N-M slots, and so can switch its power hungry circuitry off. The specification goe s further by also spec ifying a third parameter called ‘timeout’ (T) which specifies ‘extra’ timeslots that the slave will agree to listen for after receiving a valid data packet.
5.5 RF performance 5.5.1 Transmit Power Conducted Transmit Power: minimum: 1mW (0dBm) maximum: 4mW (6dBm) Power class 1 Antenna Gain: +2dBi typical. Effective Transmit Power: min: 2dBm max:8dBm 5.
case data though-put with and wi thout the AT command processing. Distances are measured in free space between 2 blu 2i Modules. Data Transfer Rate / Distance 0 100 200 300 400 500 600 700 800 10m 50m 100m 150m 200m 250 m 300m Distance ( meters) Data Transfer Rate ( kbps) RF data rate Serial port data rat e 5.
5.6 Reliability Parameter Minimum Maximum Thermal Shock 200cycles -40ºC /+85ºC 30 min 1 cycle/hour Vibration Continuous operation at 60 Hz, 2mm stroke 15g max sine wave, 12 hours Shock 50G 11ms Half.
RS232 Modem Signals 6 Just as a telephony modem has control and status lines, the blu 2i Module also provides for 6 control and stat us lines as per the table below.
specified in S Register 519 then the connection is dropped as if an ATH command was received. 2 PIO2 (RI), is normally deasserted. When an incoming connection is detected it will be asserted, until the connection is either answered or rejected using ATA and ATH respecti vely.
Future enhancement may allow the BR EAK signal to be used to map to GPIO which with appropriate exte rnal hardware may allow for a BREAK to be reproduced on the TX line. 6.3 Reset The module can be reset by the host without the need of any I/O using a BREAK signal.
Pure Cable Replacement Mode 7 7.1 Data Cable The module has the capability of being preset into a pure 5-wire data cable replacement mode. The 5 wi res being RX, TX, CTS, RTS and GND. This mode requires no change s to a host application since the Bluetooth connection is automatically set up on power up and will retry when the connection drops.
Where <bdaddr_m> is optional. If it is not specified, then the slave unit will accept connections from any device. If specified then only connections from the device specified will be accepted.
ATS504=1 ATS530=2000 ATS532=1 AT&W AT+BTR<bdaddr_s> And the slave is configured by, AT&F ATS512=4 ATS0=-1 AT&W AT+BTR<bdaddr_m> 7.3 Modem Control and Status Signals A serial port has DTR, DSR, RTS, CTS, DCD and RI control lines.
Getting S t arted 8 This section describes how to quickly make your first Bluetooth connection based on the following co mbinations of Bluetooth hardware:- 1. Two blu 2i Modules. 2. One blu 2i Module and a Bluetooth Enabled PC using TDK’s Go Blue USB Adaptor or PC Card.
Now typing characters on one terminal emulator will result in them being displayed on the other terminal emulator, proving wireless communications. 8.1.
8.2 Factory Default Mode The module is capable of operating at a very wi de range of baud rates and S Registers 520 and 521 allow the baud rate to be set very easily. The baud rate clock generator in the module is m ore versatile that that available in a standard 16550 UART commonly available in PCs.
Baud rate: 300 to 921600 Parity: None, Odd, Even Data Bits: 7 or 8 Stop Bits: 1 or 2 Handshaking: None or CTS/RTS The unique benefits of us ing TDK Terminal are: • Status of DSR, CTS, DCD and RI are.
Appendix A Europe – EU Declaration of Conformity DECLARATION OF CONFORMITY In accordance wit h Annex IV of the EU directive 1 999/5/EC Notified Bo dy consulted: Phoenix Test-Lab ID-Number of Not ifi.
Appendix B ESD (Electrostatic Discharge) If your TDK Bluetooth device is affected by ESD, it is recommended that you restart any Bluetooth processes that were active at the time.
36 of 36 W arranty TDK warrants that its products sha ll conform to TDK’s published specifications and remain free from defects in materials and workmanship under normal , proper and intended use for a period of two (2) years from date of purchase, p rovided that proof of purchase be furnished with any returned equipment.
Ein wichtiger Punkt beim Kauf des Geräts TDK blu2i (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie TDK blu2i noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für TDK blu2i - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von TDK blu2i reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über TDK blu2i erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon TDK blu2i besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von TDK blu2i verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit TDK blu2i. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei TDK blu2i gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.