User’ s Manual English V ersion Digital K onnekt x32.
.
1 Read these instructions. 2 Keep these instructions. 3 Heed all warnings. 4 Follow all instructions. 5 Do not use this apparatus near water . 6 Clean only with dry cloth. 7 Do not block any ventilation openings. Install in accordance with the manufacturer's instructions.
EMC/EMI This equipment has been tested and found to comply with the limits for a Class B Digit al device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in residential installations.
TC Electronic, Sindalsvej 34, DK-8240 Risskov – tcdk@tcelectronic.com Manual revision 1.01 – SW – V 2 English Version INTRODUCTION Important Safety Instructions . . . . . . . . . . . . . .a Certificate of Conformity . . . . . . . . . . . . . . .
.
INTR ODUCTION Digit al Konnekt x32 – Patchbay , Format Converter , Audio Interface and hardware integrator Digital Konnekt x32 not only put s patching and signal-splitting under preset control, and convert s between formats. What comes out is also better than what went in.
Selecting channels For each input channel pair one input type can be selected. Example 1 In the example below the following is selected: Input channel pair 1/2: T os Input channel pair 3/4: SPDIF Inpu.
SRC Digital Konnekt x32 has 4 sample rate converters and thus features individual sample rate conversion on any input channel pair in this section OR on all ADA T channels. When activating sample rate conversion SRC in the ADA T section, any selected sample rate conversion in the AES/SPDIF/TOS section is deselected.
OPERA TION 8 AD A T Routing The four ADA T channel pairs can be routed to any pair of AES+SPDIF+TOS channels and to the eight ADA T channels simultaneously as well. Example 2 In the example below the following is selected: Normal sample rate ADA T ch.
OPERA TION 9 Example 3 A typical setting for this section would be: • Routing firewire channels 1-8 to AES+SPDIF+TOS 1-8 • Routing firewire channels 9-16 to ADA T . This is set up in the following way: • Press 1-8 to route firewire channels 1-8 We have routed channels 1/2 to monitor out.
OPERA TION 10 Internal Clock Y ou may also choose to lock to an internal clock rate. The following rates can be selected by pressing the INT button. 44.1 48 88.2 96 176.4 192 kHz kHz kHz kHz kHz kHz 44.1k clock rate t n e INT 48k x2 x4 SEL 44.1k clock rate ut n e INT 48k x2 x4 SEL 44.
OPERA TION 11 Input Signal Monitor LEDs The blue LOCK SIG LEDs normally indicate the current lock state for each of the input sections. However , these LEDs can also be used as input meters for these sections. Press to activate. Security Lock T o avoid unintended operation of the front panel controls, these can be locked.
OPERA TION 12 FORMAT CONVERTER | PA TCHBAY | FIREWIRE IO digital konnekt x32 3-4 3-4 3-4 1-2 1-2 1-2 5-6 5-6 5-6 7-8 7-8 7-8 adat adat adat mon mon mon setup /util scenes aes/spdif/tos in adat in firewire in master clock aes+spdif+tos aes+spdif+tos aes+spdif+tos SRC SPDIF TOS NS 1-8 44.
13 1 - Analog Out Balanced analog outputs on 1/4” TRS jacks. The level of the outputs is controlled by the monitor level control knob on the front panel. 2 - AES/EBU inputs Female XLR connectors for up to 8 AES channels. 3 - AES/EBU outputs Male XLR connectors for up to 8 AES channels.
14 INTEGRA T OR The Integrator plug-in for DigitalKonnekt32 makes integration of external hardware into your DA W environment seamless. It offers a “plug-in” audio routing represent ation of your external digital ef fects processors and operates as a normal VST/AU plug-in.
15 The Integrator plug-in is automatically installed when the TC Near control panel is inst alled. P arameters Lock Green - indicates correct lock between the selected external digital device and Digit al Konnekt x32. Red - indicates “no lock”. Check connections and settings.
SETUP EXAMPLES 16 Example 1: Integrating external har dwar e with y our D A W REVERB 4000 FIREWORX FINALIZER 96K NON TC PRODUCT C400XL COMPUTER ACTIVE SPEAKERS FORMAT CONVERTER | PATCHBAY | FIREWIRE I.
SETUP EXAMPLES 17 Setting up Digit al Konnekt x32 AES/SPDIF/TOS in • SPDIF is selected for channel pairs 1/2 and 3/4. • AES is selected for channel pairs 5/6 and 7/8 (no LEDs are lit). ADA T in • We select Normal Sample rate and route ADA T channels to ADA T out.
The Integrator Now that Digital Konnekt x32 is set up it is time to set up your DA W application utilizing the Integrator plug-in. For each external effect, one inst ance of the Integrator plug-in must be set up. Each of the Integrator instances then represents one external ef fect.
Integrator always acts as a stereo plug-in, - also when inserted on a mono-track. C400XL • Insert the Integrator on a stereo track on a stereo bus. • Select firewire channel 7/8 by selecting “fw ch 7” Finalizer 96K • The Finalizer will typically be used for mastering.
SETUP EXAMPLES 20 Example 2: Con ventional audio interface PREAMP #2 PREAMP #1 CD/DVD PLA YER COMPUTER AIR SPEAKERS FORMAT CONVERTER | PATCHBAY | FIREWIRE IO digital konnekt x32 3-4 3-4 3-4 1-2 1-2 1-.
Setting up Digit al Konnekt x32 AES/SPDIF/TOS in • SPDIF is selected for channel pair 1/2. (keyboard) • TOS is selected for channel pair 3/4 (CD player) • SPDIF is selected for channel pairs 5/6.
In this example Digital Konnekt x32 is used in a live situation as a digital splitter box that routes the signal to both a laptop computer for recording/play-back, to the P A system via a master EQ and to a broadcast station.
23 SETUP EXAMPLES Setting up Digit al Konnekt x32 AES/SPDIF/TOS in • AES 1/2 is selected in the AES/SPDIF/TOS section as none of the LEDs are lit. The blue 1/2 LED indicates that a signal is present.
24 This example illustrates Digital Konnekt x32 used in conjunction with a ProT ools setup integrating external digital devices. The screenshot in this example is based on ProT ools HD but applies to any version of Pro T ools hardware that has digital in (AES/EBU, SPDIF , ADA T , TOS or W ord Clock).
SETUP EXAMPLES 25 Setting up Digit al Konnekt x32 AES/SPDIF/TOS in • SPDIF is selected for channel pair 5/6 (Reverb 4000) - select T OS 5/6 to route the DVD player instead SRC is activated for chann.
Buffer Siz e Buffer Size* The buffer size can be set from 32 to 8192 samples. The higher the buffer setting, the longer latency through Digital Konnekt x32. Y ou should only increase the buffer size if you experience problems such a clicks and pops in the sound.
Status V arious lock status indications can be given: Internal Lock Indicates that the system is locked to the Digital Konnekt x32 unit set as clock master . External Lock Indicates that the system is locked to an external digital device connected to the Digital Konnekt x32 set as clock master .
Digital Input s and Outputs Connector (AES): Formats (AES): Connector (S/PDIF): Formats (S/PDIF and T osLink): Connector (ADA T® or T osLink): Format (ADA T®): Word Clock: Firewire (format): Firewir.
Ein wichtiger Punkt beim Kauf des Geräts TC electronic SDN BHD x32 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie TC electronic SDN BHD x32 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für TC electronic SDN BHD x32 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von TC electronic SDN BHD x32 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über TC electronic SDN BHD x32 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon TC electronic SDN BHD x32 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von TC electronic SDN BHD x32 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit TC electronic SDN BHD x32. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei TC electronic SDN BHD x32 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.