Benutzeranleitung / Produktwartung SSE-X24S des Produzenten SUPER MICRO Computer
Zur Seite of 27
Release: 1.0c 1 / 27 Supermicro Switch Web GUI Quick Configuration Guide Switch Web GUI Quick Configuration Guide for SSE-G48-TG4 SSE-G24-TG4 SSE-X24S SSE-X24SR SSE-X3348S .
Release: 1.0c 2 / 27 Supermicro Switch Web GUI Quick Configuration Guide .
Release: 1.0c 3 / 27 Supermicro Switch Web GUI Quick Configuration Guide The information in this User’s Manual has been carefully rev iew ed and is believed to be accurate.
Release: 1.0c 4 / 27 Supermicro Switch Web GUI Quick Configuration Guide Contents 1 Introduction ................................................................................................................ . 5 2 Basic Configurations .
Release: 1.0c 5 / 27 Supermicro Switch Web GUI Quick Configuration Guide 1 Introduction This document is designe d to provide Supermicro switch users with the information required to configure the basic functionalities on the switch th rough its Web gra phical user in terface (GUI).
Release: 1.0c 6 / 27 Supermicro Switch Web GUI Quick Configuration Guide 2 Basic Configurations 2.1 Login Page When you type the switch IP address into the bro wser, the following Login page appe ars. Fig 1: Login page Enter the User Name and Password and click on the Login butto n.
Release: 1.0c 7 / 27 Supermicro Switch Web GUI Quick Configuration Guide Middle Configuration Links Table Except for the Page Top LED Display section, the Home page is .
Release: 1.0c 8 / 27 Supermicro Switch Web GUI Quick Configuration Guide The Logout link provides a means of signing out of the manageme nt web application. It returns to the login screen requesting a user name and password for login.
Release: 1.0c 9 / 27 Supermicro Switch Web GUI Quick Configuration Guide 2.2.3 Left Side Tree The Left Side Tree display on the left side of t he page provide s qui ck acce ss to configuration pages. This tree is organized based on the featur es supported in th e swit ch.
Release: 1.0c 10 / 27 Supermicro Switch Web GUI Quick Configuration Guide 2.3 Management IP Address Note : The default management IP address fo r all Supermicro switch produ cts i s: 192.168.100.102 . Swit ch Management IP Interface SSE-G24-TG4 SSE-G48-TG4 The management IP address is configured for VLAN 1.
Release: 1.0c 11 / 27 Supermicro Switch Web GUI Quick Configuration Guide 2.3.1 Changing the Management IP Address & Gateway The management IP address and defaul t gateway can be configured in the System M gmt Management IP page .
Release: 1.0c 12 / 27 Supermicro Switch Web GUI Quick Configuration Guide 2.4 User Accounts The default administrative user name for all Super micro switch es is ADMIN and the pa ssword for all these switches is also ADMIN.
Release: 1.0c 13 / 27 Supermicro Switch Web GUI Quick Configuration Guide 2.5 Interface MTU and Jumbo Frames The interface MTU can be change d in Layer2 M gmt Port Manager Basic Settings page. The default MTU is 1500 bytes.
Release: 1.0c 14 / 27 Supermicro Switch Web GUI Quick Configuration Guide Interfaces can be given a description o r name in te xt. This helps users to identify or rememb er the interface connections with other co mpone nts on the network.
Release: 1.0c 15 / 27 Supermicro Switch Web GUI Quick Configuration Guide 2.7 Stacking The SSE-G24-TG4 and SSE-G48-TG4 switches support stacking of up to 16 switches. SBM- GEM-X2C, SBM-GEM-X2C+ sup port stacking of up to 8 swit ches.
Release: 1.0c 16 / 27 Supermicro Switch Web GUI Quick Configuration Guide Note: 1. Do not use the same switch ID for mul t iple switches on the stack. 2. All switches in the stack can only be configured through the master switch.
Release: 1.0c 17 / 27 Supermicro Switch Web GUI Quick Configuration Guide In the Upstream Interfaces field and Do wnstream Interfaces fields, list the po rts as comma separated without space chara cters.
Release: 1.0c 18 / 27 Supermicro Switch Web GUI Quick Configuration Guide 2.9 Saving Configurations Switch configurations can be save d on the System Mgmt File Management page. You can save a currently running swit ch configuration in one of thre e ways.
Release: 1.0c 19 / 27 Supermicro Switch Web GUI Quick Configuration Guide 2.10 Upgrading Firmware Switch firmware can be upgraded in the System Mgmt Firmware Upgrade page. Flash Area – The default selection is Normal to upgrade firmware i n normal flash area.
Release: 1.0c 20 / 27 Supermicro Switch Web GUI Quick Configuration Guide 2.11 Resetting to Factory Defaults Supermicro switches can be rese t to factory defaults in the System M gmt System Settings page. This page has a button that you c an press to allow a “Reset To Fa ctory Defaults”.
Release: 1.0c 21 / 27 Supermicro Switch Web GUI Quick Configuration Guide 3 VLAN Configurations The SSE-G24-TG4, SSE-G48-TG4, SBM-GEM -X2C, SBM-GEM-X2C+ and SB M-GEM-X3S+ switches support 1024 static VLANs.
Release: 1.0c 22 / 27 Supermicro Switch Web GUI Quick Configuration Guide Member Ports – Provide all the member ports of thi s VLAN including tagged and untagged member ports. Untagged Ports – These are the member po rts that need to be configured as u ntagge d ports.
Release: 1.0c 23 / 27 Supermicro Switch Web GUI Quick Configuration Guide 4 Link Aggregation (LA) Link Aggregation (LA) is a method of combinin g multiple parallel physi ca.
Release: 1.0c 24 / 27 Supermicro Switch Web GUI Quick Configuration Guide Fig 13: LA Status Page 4.2 Creating a Port Channel A port channel can be created in the Layer2 Mgmt LA Interface Setting s page.
Release: 1.0c 25 / 27 Supermicro Switch Web GUI Quick Configuration Guide Fig 14: Port Channel Page To create any port channel, enter the Port Channel ID in the page-top dialog bo x and click Add .
Release: 1.0c 26 / 27 Supermicro Switch Web GUI Quick Configuration Guide 4.3 Associating a Port Channel with Ports Once a port channel is created in the port chan nel page, it can be asso ciated with the require d physical ports.
Release: 1.0c 27 / 27 Supermicro Switch Web GUI Quick Configuration Guide 4.4 Configuring Port Channel Parameters Once a port channel is created and associate d with the required ports, y ou can config ure the port channel parameters.
Ein wichtiger Punkt beim Kauf des Geräts SUPER MICRO Computer SSE-X24S (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie SUPER MICRO Computer SSE-X24S noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für SUPER MICRO Computer SSE-X24S - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von SUPER MICRO Computer SSE-X24S reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über SUPER MICRO Computer SSE-X24S erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon SUPER MICRO Computer SSE-X24S besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von SUPER MICRO Computer SSE-X24S verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit SUPER MICRO Computer SSE-X24S. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei SUPER MICRO Computer SSE-X24S gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.