Benutzeranleitung / Produktwartung 4000 des Produzenten StorageTek
Zur Seite of 45
8946121402 StorageNet Fibre Channel Switch 4000 SES (SCSI-3 Enclosure Services) User Guide.
.
8946121402 StorageNet Fibre Channel Switch 4000 SES (SCSI-3 Enclosure Services) User Guide.
ii 8946121402 Revision History The U.S. Department of Commerce restricts the distribution of technical information contained in this document when exported outside the U.S. Therefore, careful attention should be gi ven to compliance with all applicable U.
8946121402 iii About This Document Intr oduction Use this guide for monitoring, configuring, and maintaining a StorageNet Fibre Channel Switch 4000 through SCSI-3 Enclosure Services (SES). Y ou should be kno wledgeable about networking in general, routing and bridging in particular .
iv 8946121402 Notice to the Reader The material contained in this publication is for informational purposes only and is subject to change without notice. StorageT ek is not responsible for the use of any product options or features not described in this publication, and assumes no responsibility for any errors that may appear in this publication.
8946121402 v Table of Contents Chapter 1 Pr oduct Overview Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 SES Management . . . . . . . . . . . . . . . . . . .
vi 8946121402 Chapter 4 T roub leshooting Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1 License Reject . . . . . . . . . . . . . . . . . . . . . . . . . . .
8946121402 vii List of Figures Figure 1-1 SES Ov er view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 Figure 2-1 SES Distribution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
viii 8946121402.
8946121402 ix List of Tables T able 1-1 Example LUN Mapping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 T able 2-1 F ormat of LUN recognized by SESD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2 T able 2-2 LUN Mapping .
x 8946121402.
8946121402 1-1 Chapter 1 Product Overview Intr oduction This chapter describes StorageT ek’ s implementation of SES (SCSI-3 Enclosure Services) on the StorageNet Fibre Channel Switch 4000. SES implementation in a SCSI-3-based Host Adapter is up to the adapter manufacturer and StorageT ek cannot determine their implementation.
SES Management 1-2 8946121402 Figure 1-1 SES Overview LUN addressing within the Fabric can be non-sequential because it is based on the switch’ s Domain_ID . T able 1-1 shows the sample LUN mapping used with Figure 1-1 . Figure 1-1 sho ws that the switch in the lo wer left hand corner is assigned both LUN5 and LUN0.
SES Management 8946121402 1-3 Therefore, if there are 5 switches in the Fabric SES reports 6 LUNs, one LUN v alue for each switch and LUN0 for the local client connection. Other SCSI-3 enclosures can also run SES outside the Fabric, such as JBODs, RAID-5 arrays, SCSI-3 hard dri ves, and SCSI-3 tape dri v es.
SES Management 1-4 8946121402.
8946121402 2-1 Chapter 2 SES Concepts Intr oduction This chapter uses generic terms to describe enclosure services and specific SES implementation. SES instances can be distributed inside and outside of the F abric to an y enclosure capable of supporting enclosure services through an SES de vice.
SES Functional Model 2-2 8946121402 Figure 2-2 SES Functional Model At the Fibre Channel le vel, each SESD is accessible through the Fibre Channel well kno wn address, FFFFFAh (Management Server). At the SCSI-3 le v el, it is associated with a LUN. An SES Application Client can refer to any distrib uted SESD within the F abric using its LUN.
Access to the Enclosure Ser vices Process 8946121402 2-3 An SES Application Client may easily find the LUN values of all distrib uted SESDs inside the Fabric by using the Report LUNs command. See the “Report LUNs” section in Chapter 3 for more information.
Indicators and Control Management 2-4 8946121402.
8946121402 3-1 Chapter 3 SES Commands Intr oduction This chapter contains information and examples on managing SES, including the follo wing: • FC-PH constructs • FCP and SES commands • Diagnostics pages Note: SESD can be accessed from any F abric switch licensed to run SES.
FCP Constructs 3-2 8946121402 FCP Constructs Before initiating any FCP request, the Nx_Port associated with the SES Application Client (FCP Initiator) must complete an N_Port Login ( PLOGI ) with the Management Server in Class 2 or 3. Note: The destination address in the PLOGI request must be set to FFFFFAh .
FCP Constructs 8946121402 3-3 The FCP_LUN v alue format is described in T able 3-3 or the value is 0. The latter refers to the SESD on the local switch. The FCP_CNTL value is set to 1, 2 or 0 depending on whether READ D A T A , WRITE D A T A or neither is in volved in the command.
FCP and SES Commands 3-4 8946121402 T able 3-5 shows the FCP_STATUS field format. The reserved bits are set to 0 by the SESD. FCP_RESID_UNDER indicates that the FCP_RESID field is v alid and contains the number of bytes expected to be transferred, b ut were not transferred.
FCP and SES Commands 8946121402 3-5 Switch Diagnostics P ages Before each SCSI command is discussed in detail, the diagnostics pages are defined in T able 3-7 . They are particularly rele v ant to two commands: Receive Diagnostic Results and Send Diagnostics .
FCP and SES Commands 3-6 8946121402 Switch P age If requested using the Send Diagnostic or Receive Diagnostic Result command, the SESD returns the response sho wn in T able 3-10 .
FCP and SES Commands 8946121402 3-7 The field swValid is bit mapped and indicates which subsequent fields within the page are v alid. The bit position for subsequent fields starts from 0, as indicated in the Field # column of T able 3-10 .
FCP and SES Commands 3-8 8946121402 Neighborhood T able Pa ge If requested using the Send Diagnostic or Receive Diagnostic Result command, the SESD returns the response sho wn in T able 3-13 .
FCP and SES Commands 8946121402 3-9 Table 3-14 Fibre Channel Port Table Page Format Byte/Bit Field # Access 7 6 5 4 3 2 1 0 0 na na Page Code = 84h 1 na na Reserved 2 .. 3 na na P age Length = n - 3 4 .. 7 na na swNumEntries = i – specifies the number of entries received.
FCP and SES Commands 3-10 8946121402 Name Server Local T able P age If requested using the Send Diagnostic or Receive Diagnostic Result command, the SESD returns the follo wing response as sho wn in T able 3-15 . 108 .. 111 24 ro swFCP or tTxMcasts[0] 112 .
FCP and SES Commands 8946121402 3-11 Inquiry An SES Application Client may send an Inquiry command to obtain information about a switch in the Fabric. The format of the FCP_CDB is sho wn in T able 3-16 .
FCP and SES Commands 3-12 8946121402 If the field, EVPD is set to 1, then the v alue of the page code may be set to one of the codes sho wn in T able 3-18 . If the page code is set to 00h, the SESD will return codes sho wn in T able 3-19 . If the page code is set to 80h, the SESD will return codes sho wn in T able 3-20 .
FCP and SES Commands 8946121402 3-13 If the page code is set to 83h, the SESD will return codes sho wn in T able 3-21 . Receive Diagnostic Results An SES Application Client sends a Receive Diagnostic Results command to return diagnostic or management data.
FCP and SES Commands 3-14 8946121402 Report LUNs An SES Application Client sends a Report LUNs command to obtain the number of logical units (each is a switch in SCSI impersonation) in the Fabric. The CDB format is sho wn in T able 3-23 . The SESD reports the LUNs of associated switches with the format sho wn in T able 3-24 .
FCP and SES Commands 8946121402 3-15 Send Diagnostic A SES Application Client can use a Send Diagnostic command to configure/diagnose a logical unit. After the command completion, the SES Application Client sends a Receive Diagnostic Results command.
FCP and SES Commands 3-16 8946121402 Reject The SESD issues a Reject command to set status to Check Condition and the appropriate v alues for the Sense K ey ( SK ) field. Additional Sense Code ( ASC ) and Additional Sense Code Qualifier ( ASCQ ) v alues are as sho wn in T able 3-28 .
8946121402 4-1 Chapter 4 Troubleshooting Intr oduction This chapter discusses the SEND DIAGNOSTIC command error messages. License Reject A license reject is generated when the SES license ke y is improperly entered or is not installed.
Introduction 4-2 8946121402.
8946121402 A-1 Appendix A Glossary A pplication Client: The source object of the SCSI commands and destination for the command responses. Byte: A group of 8 bits. Command Descriptor Block: The structure of up to 16 bytes in length used to communicate commands from the application client to a de vice server .
A-2 8946121402 Logical Unit: A target-resident entity that implements a de vice model and ex ecutes SCSI commands originated by an application client. Logical Unit Number: A device or element kno wn by an enclosure that identifies it to the application client.
8946121402 Index-1 Index A Application Client A-1 ASC Field 3-16 ASCQ Field 3-16 B Bit Page Code Valid 3-13 Byte A-1 C Code Additional Sense 3-16 Additional Sense Code Qualifier 3-16 Sense NO ADDITION.
Index-2 8946121402 P Page Diagnostics 3-5 Fabric 3-7 Fibre Channel Port Table 3-8 Neighborhood Table 3-8 Sensor Table 3-7 Supported Diagnostics 3-5 Switch 3-6 Page Code Valid Bit 3-13 R Receive Diagno.
Comment Sheet StorageT ek welcomes your comments about this publication. Please complete this form, including your name and address, and mail it to StorageT ek, T echnical Communications Department, 7600 Boone A venue North, Minneapolis, Minnesota, 55428-9919, USA.
BUSI NESS REPL Y MAIL POST AGE WILL BE P AID BY ADDRESSEE STORA GETEK FOLD FOLD A TTN: TECHNICAL COMMUNICA TIONS DEP ARTMENT 7600 BOONE A VENUE NOR TH MINNEAPOLIS, MN 55428-9919 NO POST AGE NECESSAR Y IF MAILED IN THE UNITED ST A TES T APE T APE DO NOT ST APLE CUT ON VER TICAL LINE FOLD 1ST FOLD 1ST FIRST CLASS MAIL PERMIT NO.
StorageT ek Pr oblem Reporting Please be aware that, depending on y our maintenance and/or warranty co verage, the ser vices deliver ed may be char geable. This form is provided for your con venience in gathering information for your call. Make as man y copies as you wish.
Ein wichtiger Punkt beim Kauf des Geräts StorageTek 4000 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie StorageTek 4000 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für StorageTek 4000 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von StorageTek 4000 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über StorageTek 4000 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon StorageTek 4000 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von StorageTek 4000 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit StorageTek 4000. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei StorageTek 4000 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.