Benutzeranleitung / Produktwartung Marley Aquatower des Produzenten SPX Cooling Technologies
Zur Seite of 12
/ Mar le y A quat o w e r ® Cooling T ower /.
2 / The Aquat ow er Adv antag e / ■ Proven Performance. CTI Certified. Plus SPX stands by its responsibility for r eliable thermal per formance. We designed it.
3 / The Mar ley Dif f er ence / T oday’ s Aquatower may be the most space/energy- efficient cooling tower available. Y our needs have dictated constant technological improvement. Thousands of Aquatower users enjoy the benefits of eight major redesigns and dozens of minor improvements in the past 40 years.
4 SIDE ELEV A TION AIR INLET ELEV A TION 1. Nominal tons are based upon 35°C HW , 29.5°C CW , 25.5°C WB and .68 m 3 /hr per ton. The Marle y UPD A TE web-based selection sof t ware provides Aquato wer model recommendations based on specific design requirements.
5 1. Use this bulletin for preliminary layouts only . Obtain current draw- ings fr om your Marley sales repr esentative or your local distribu- tor . 2. Purchaser to provide tower suppor ts complete with holes and bolts for anchorage. All supports must be framed flush and level at top.
6 / Constr uction And Components / ■ Water Distribution System W arm water flows through external piping (not included with the tower) into a splash box chamber at the top of the Aquatower . A splash box prevents the incoming water from spilling out of the basin and helps provide uniform water distribution.
7 / Constr uction And Components / ■ Mechanical Equipment Belt-driven propeller fans insur e design airflow at minimum power . Fans are supported by an oil-lubricated tapered r oller bearing assembly with remote oil r eservoir . For ease of maintenance all drive components are accessible from outside the tower .
8 / F r eeze Pr evention / When the ambient air temperature falls below 0°C, the water in a cooling tower can freeze. Marley T echnical Report #H-003 “Operating Cooling T owers in Freezing Weather” describes how to prevent fr eezing during operation.
9 / Field Assembly / 1. Maximum m 3 /hr applies to both pump and gravity flow piping sys- tems. The outlet piping on gravity flow systems must have sufficient vertical drop to overcome all other head losses in the system. 2. Bottom outlet is not available on Models 490A and 490B.
10 / Options / V er tical Discharge Hood This option is available on Models 494A and larger . It provides vertical discharge of the air leaving the tower . Hoods are galvanized steel. They ship separately for installation by others. A large ac- cess door provides entry to the fan and mechanical equipment.
11 Base: Furnish and install an induced-draft, crossflow , factory- assembled, steel cooling tower of ____ cell(s), as shown on plans. T ower shall be similar and equal in all respects to Marley Series 4900 Aquatower , Model _______. T ower must be warranted by the manufacturer for one year from date of shipment.
SPX CO OLI NG TEC H N OL OG I ES U K L TD.. G R EGO RY'S BAN K WOR CESTE R WR3 8AB U N ITE D KI NG DO M +44 (0) 1905 7 20 200 info.uk@spx.com spxcooling.com In the i nterest o f tec hnologic al progre ss, all products are subject to design and/or material change without notice.
Ein wichtiger Punkt beim Kauf des Geräts SPX Cooling Technologies Marley Aquatower (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie SPX Cooling Technologies Marley Aquatower noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für SPX Cooling Technologies Marley Aquatower - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von SPX Cooling Technologies Marley Aquatower reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über SPX Cooling Technologies Marley Aquatower erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon SPX Cooling Technologies Marley Aquatower besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von SPX Cooling Technologies Marley Aquatower verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit SPX Cooling Technologies Marley Aquatower. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei SPX Cooling Technologies Marley Aquatower gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.