Interaktiv Showerpanel Installation Instructions / W arranty.
Interaktiv Showerpanel I Interaktiv Showerpanel II Showerpanel I Showerpanel II handshower & bodyjets handshower , bodyjets, tub spout Metro 06572000 06573000 Solaris 06549XX0 06550XX0 Stratos 06564XX0 06565XX0 Interaktiv S 06893000 06894000 Proaktiv* 06964000 06971000 Product Specification Flow rate of handshower 2.
Check Package Contents Save time and aggravation. Before beginning installation, check the contents of this package. Make sure that all parts are present and in good condition. If any par t is missing or damaged, please contact Hansgrohe Customer Ser vice before proceeding.
Roughing-in This unit can be installed on a flat wall or in a 90 o corner . Instructions for installation on a flat wall begin on page 5. Go to page 8 if the panel is to be installed in a corner . Ensure that you have a minimum 83” ceiling height from the standing surface.
Installation -- Flat W all W rap the threads on the supply nipples with T eflon thread tape. Install the enclosed elbows so that the outlets face upwards. Measure up the wall 78 ¾”, making sure that the line is plumb. Mark the position for the top screw hole.
Use the compression nuts and ferrules to connect the supply hoses on the panel to the supply elbows. Use two wrenches, as shown, to prevent the supply hoses from twisting. Attach the seals to the side covers. Install the side covers. The pins on the covers must go into the grooves on the sides of the panel.
Push the bodyjet supply hose on the valve cover into the fitting on the panel. Install the valve cover on the panel. The pins on the cover must connect to the slots on the panel.
Installation in 90 o Corner W rap the threads on the nipples with T eflon thread tape. Install the enclosed elbows so that the outlets face upwards. In the corner , measure up the wall 78 ¾”, making sure that the line is plumb. Mark the position for the top mounting bracket.
While a helper holds the panel, attach the supply hoses to the elbows with the compression fittings. Use two wrenches, as shown in the diagram, to prevent the supply hoses from twisting.
Clip the side cover seals as shown in the diagram. Attach the side cover seals to the valve cover . Push the bodyjet supply hose on the valve cover into the fitting on the panel. Install the valve cover on the panel. The pins on the cover must connect to the slots on the panel.
Install the Handle Push the handle over the valve stem. T ighten the set screw on the bottom of the handle with a 3 mm Allen wrench. The set screw must engage the slot milled into the thermoelement. Install the Handshower Place a black rubber washer in the short hose end connector .
Justify the Handle T urn the temperature control knob so that the indicator is next to the 100 o marking. Replace the handle. T ighten the set screw . T urn the water on to the handshower . T ur n the temperature control knob so that the water mea- sures 100 o F on a thermom- eter .
Set the High T emperature Limit Stop (optional) Loosen the set screw on the handle. Remove the handle. Remove the clip and the high temperature limit stop from the stem. Grasp the barrel on the cartridge and tur n it counter - clockwise to turn on the handshower .
Using the Handshower The handshower has 3 spray modes -- Rainl AIR, Whirl AIR, and Balance AIR. Push the function lever until the desired spray mode is achieved. User Instructions - Showerpanel I T urn the temperature control knob clockwise to make the water cooler , counter-clockwise to make it warmer .
Scale Removal The Raindance Air 3-jet handshower incorporates the Rubit TM cleaning system. If scale deposits are noticed in the spray channels, turn the water on lightly and rub the spray channels with a finger or a sponge.
A possible cause of lost pressure, especially if the pressure decreases as the temperature increases, is debris clogging the filter screens on the thermostatic cartridge. If this occurs, the screens should be cleaned. T urn the water off at the main. Remove the handle.
Replacement Parts 1 slider 97024000 2 hose 28276XXX 3 shelf 25969000 4 sleeve 88520XXX 5 thermostat cartridge 94282000 6 thermoelement, panel I 88533000 thermoelement, panel II 88500000 7 side cover 2.
Limited Lifetime Consumer W arranty This product has been manufactured and tested to the highest quality standards by Hansgrohe, Inc. (“Hansgrohe”). This warranty is limited to Hansgrohe products which are purchased by a consumer in the United States after March 1, 1996, and installed in either the United States or Canada.
year , with respect to Interaktiv and Retroaktiv products, and (ii) for 5 years, with respect to AXOR, ShowerPower and Pharo products. THIS W ARRANTY DOES NOT COVER, AND HANSGROHE WILL NOT P A Y FOR: A. Conditions, malfunctions or damage not resulting from defects in material or workmanship.
Hansgrohe, Inc. • 1490 Bluegrass Lakes Parkway • Alpharetta, GA 30004 T el. 770 360-9880 • Fax 770 360 9887 www .hansgrohe-USA.com US - Installation Instructions • Part No.
Ein wichtiger Punkt beim Kauf des Geräts Axor Showerpanel (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Axor Showerpanel noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Axor Showerpanel - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Axor Showerpanel reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Axor Showerpanel erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Axor Showerpanel besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Axor Showerpanel verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Axor Showerpanel. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Axor Showerpanel gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.