Applicable A uto Switch T ype Reed switch Solid state switch Auto s witch model Electrical entry Auto switch mounting Applicable rotary actuators Size Applicable air grippers Size P age 2-color indica.
1. Check the specifications. Read the specifications carefully and use this product appropriately. The product may be damaged or malfunction if it is used outside the range of specifications of current current, voltage, temperature or impact. 2. Use caution when multiple cylinders are used and close to each other .
1. Do not drop or bump. Do not drop, bump, or apply excessive impacts (300 m/s 2 or more for reed switches and 1000 m/s 2 or more for solid state switches) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction.
1. Never use in the presence of explosive gases. The construction of our auto switches does not make them explosion-proof. Never use them in the presence of an explosive gas, as this may cause a serious explosion. 2. Do not use in an area where a magnetic field is generated.
Before Operation Auto Switches Common Specifications Auto Switches Common Specifications Lead Wire Length Lead wire length indication Contact Protection Box: CD-P11, CD-P12 D-A73 Nil L 0.5 m 3 m L Leakage current Operating time Impact resistance Insulation resistance Withstand voltage Ambient temperature Enclosure Reed switch None 1.
Before Operation Auto Switches Connection and Example Basic Wiring Example of Connection with PLC (Programmable Logic Controller) Example of AND (Series) and OR (Parallel) Connection Solid state 3-wir.
Reed Switch Band Mounting Style D-A72/D-A73/D-A80 Auto Switch Specifications Dimensions Grommet Electrical entry: Perpendicular Weight Auto switch model 0.
Indicator light D-A80H without indicator light Most sensitive position Auto Switch Internal Circuit D-A72H D-A73H D-A76H D-A80H Auto Switch Specifications Dimensions Auto switch model 0.
Indicator light D-A80C without indicator light Most sensitive position Lead wire with connector Reed Switch Rail Mounting Style D-A73C/D-A80C Auto Switch Internal Circuit D-A73C D-A80C Auto Switch Specifications Dimensions 1. Confirm that the connector is appropriately tightened.
( ): dimensions for D-A93. D-A90V , D-A93V , D-A96V Auto Switch Specifications Grommet Electrical entry: In-line PLC: Abbreviation of Programmable Logic Controller D-A90, D-A90V (Without indicator lig.
Most sensitive position Auto Switch Internal Circuit D-A79W Auto Switch Specifications Weight Dimensions Grommet Indicator light / Display method Auto switch model 0.5 3 5 11 53 — D-A79W Lead wire length (m) Note 1) Operating load is an induction load.
Auto Switch Internal Circuit D-F79 D-J79 D-F7P Auto Switch Specifications Weight Dimensions Auto switch model 0.5 3 5 D-F79 D-F7P D-J79 Grommet Lead wire length (m) D-F7 , D-J79 (With indicator li.
Indicator light Most sensitive position ø3.5 mounting hole Auto Switch Internal Circuit D-F7NV D-F7BV D-F7PV Auto switch model 0.5 3 5 13 57 92 13 57 92 11 50 81 D-F7NV D-F7PV D-F7BV Grommet Electric.
Auto Switch Internal Circuit D-J79C Auto switch model 0.5 3 5 13 52 83 D-J79C Connector Lead wire length (m) D-J79C Auto switch model Wiring type Output type Applicable load Power supply voltage Curre.
Grommet D-F8N D-F8B D-F8P Auto switch model Electrical entry direction Wiring type Output type Applicable load Power supply voltage Current consumption Load voltage Load current I nternal voltage drop.
Auto Switch Internal Circuit D-M9N, D-M9NV D-M9B, D-M9BV D-M9P, D-M9PV Auto switch model 0.5 3 5 D-M9N(V) 8 41 68 D-M9P(V) 8 41 68 D-M9B(V) 7 38 63 Lead wire length (m) • Lower load current • Lead.
D-Y5 , D-Y6 , D-Y7P , D-Y7PV (With indicator light) Auto switch model Electrical entry direction Wiring type Output type Applicable load Power supply voltage Current consumption Load voltage Load current Internal voltage drop Leakage current Indicator light D-Y59A In-line 3-wire NPN IC circuit, Relay, PLC 5, 12, 24 VDC (4.
Auto switch model 0.5 3 5 13 57 92 13 57 92 11 50 81 D-F79W D-F7PW D-J79W Lead wire length (m) Auto Switch Internal Circuit D-F79W D-J79W Indicator light / Display method D-F7PW Grommet D-F7 W, D-.
Auto Switch Internal Circuit D-Y7NW, D-Y7NWV D-Y7BW, D-Y7BWV D-Y7PW, D-Y7PWV Grommet Indicator light / Display method The optimum operating position can be determined by the color of the light.
Auto Switch Internal Circuit D-F9NW, D-F9NWV D-F9BW, D-F9BWV D-F9PW, D-F9PWV Grommet D-F9 W, D-F9 WV (With indicator light) Auto switch model Electrical entry direction Wiring type Output type.
Auto Switch Internal Circuit Diagnostic Output Operation Dimensions Auto switch model 0.5 3 5 13 56 90 D-F79F Grommet Lead wire length (m) ø3.4 Since the output signal can be detected in an unsteady detecting area, the difference of detecting position can be confirmed by the side of PLC (Programmable Logic Controller).
Auto Switch Internal Circuit Dimensions Grommet Water (coolant) resistant type Please consult with SMC if using coolant liquid other than water based solution.
Auto Switch Internal Circuit Dimensions Grommet Water (coolant) resistant type Please consult with SMC if using coolant liquid other than water based solution.
Auto Switch Internal Circuit Dimensions Grommet Auto switch model 0.5 3 5 D-Y7BA — 54 88 Lead wire length (m) Water (coolant) resistant type Please consult with SMC if using coolant liquid other than water based solution.
Made to Order Specifications: Solid State Switch With Pre-wired Connector • Eliminates the harnessing work by cable with connector specifications • Adopts global standardized connector (IEC947-5-2) • IP67 construction How to Order Cable length Solid state switch Standard part no.
Connector Pin Arrangement Dimensions Sensor type DC 2-wire type DC 2-wire, Non-polar type DC 3-wire type DC 4-wire type Brown — Brown Brown 1 pin — — — Orange 2 pin — Brown Blue Blue 3 pin B.
Made to Order Specifications: Solid State Switch -50: No Indicator (Dark room) Specifications -61: Oil Resistant, Flexible Cable Specifications -50 Without Indicator Light (for dark room specifications) Possible to use under the environment which hates a light.
Ein wichtiger Punkt beim Kauf des Geräts SMC Networks Reed Switch Solid State Switches (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie SMC Networks Reed Switch Solid State Switches noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für SMC Networks Reed Switch Solid State Switches - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von SMC Networks Reed Switch Solid State Switches reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über SMC Networks Reed Switch Solid State Switches erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon SMC Networks Reed Switch Solid State Switches besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von SMC Networks Reed Switch Solid State Switches verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit SMC Networks Reed Switch Solid State Switches. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei SMC Networks Reed Switch Solid State Switches gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.