Benutzeranleitung / Produktwartung EX500-GEN1 des Produzenten SMC Networks
Zur Seite of 23
Reduced wiring system EX500 - GEN1 Instruction Manual EtherNet/IP™ Compatible GW Unit Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. EtherNet/IP™ is a trademark used under licence by ODVA.
Thank you for purchasing the SMC reduced wiring system EX500 series. Please read this instruction manual carefully and understand the contents before use so that you can operate this unit safely and correctly. Please keep this manual handy for future reference.
2 3 SAFETY The body of unit and this manual contain the essential information for the protection of users and others from possible injury and property damage and to ensure correct handling.
4 5 SAFETY ( continued ) Follow the instructions given below when handling your reduced wiring system. Otherwise a damage or failure to cause a malfunction can result. Operate the reduced wiring system at the specified voltage. Reserve space for maintenance.
6 7 EX500 P ar t Names Communication connector 1 2 3 4 5 6 7 8 Note1 : For wiring method, refer to subsection "Wiring" ( page 11 ) of section "EX500" in this manual. Note2 : For display and setting method, refer to subsection "Display/Switch Setting" ( page 18 ) of section "EX500" in this manual.
8 9 Specification Basic specifications Rated voltage 24VDC Range of power supply voltage Power supply for input and controlling GW/SI : 24VDC 10% Power supply for output : 24V DC+10% /- 5% ( Voltage drop warning at around 20V ) Rated current Power supply for input and controlling GW/SI : 3.
10 11 Wiring Specification ( continued ) The wirings is explained in the following order. Communication wiring : Connection with EtherNet/IP Po wer suppl y wiring : Connections of power supplies f or .
12 13 Wiring ( continued ) Communication wiring Aligning the key groove with the communication connector ( 4-pin, socket ) of GW unit, plug the Ethernet communication cable ( plug ). Tighten the lock nut on cable side by turning it clockwise by hand. Confirm that the connector portion does not move.
24VDC 24VDC Brown : 0V ( for solenoid valves/output ) White : 24VDC ( for solenoid valves/output ) Gray : Ground ( PE ) Blue : 0V ( for input and controlling GW/SI ) Black : 24VDC ( for input and controlling GW/SI ) Cable Part No.
16 17 Wiring (continued ) For GW unit – Manifold v alve – Input unit manifold configuration Two communication connectors in SI unit and one communication connector in Input unit are installed respectively. To the communication connector ( C2 ) or ( 1 ) of SI unit, connect the branch cable with M12 connector from GW.
GATEWAY UNIT EX500 SERIES COM A COM B COM C COM D LAN NS MS 100 LINK PWR 18 19 Displa y/Switch Setting Display NOTE When connecting manifold valve only without connecting Input unit manifold, LEDs of COM A to D do not light. To make them light, connect a terminal plug to the unused connector of SI unit ( "C1" or "0" ).
21 20 SI Unit P ar t Names The SI unit is the unit to communicate with GW unit in combination with manifold valve. It can be used with SV series valves and VQC series valves. In addition, this unit is able to operate solenoid valves, relays. etc. in combination with EX9 series general purpose output block.
23 22 Mounting/Wiring The mounting and removing methods of SI unit are as shown below. For branch wiring method, refer to subsection "Wiring" ( page 15 ) of section "EX500" in this manual.
25 24 Displa y Power LED Communication LED SI unit for SV series v alves ( EX500-S 01 ) Power LED Communication LED SI unit for VQC series valves ( EX500-Q ) Power LED Lights on : Power to solenoid valves/output is supplied at the specified voltage. Lights off : Power to solenoid valves/output is not supplied at the specified voltage.
27 26 Dimensions ( unit : mm ) When only input b locks for M8 connector are connected 44.2 39.7 L3 (L4) 5 L1 L2 ( Rail mounting pitch: 12.5 ) DIN Rail 35 49 32.2 (7.5) When only input b locks of 8-point-integrated type are connected L1 [mm] : Rail length L2 [mm] : Mounting pitch L3 [mm] : Manifold length L4 [mm] 98 110.
29 28 Specification Specifications for Input unit Connected block Current source type input block ( PNP input block ) or Current sink type input block ( NPN input block ) Connected block station Max. 8 blocks Supply voltage for block 24VDC Supply current for block Current consumption 0.
31 30 Correspondence between input number and input bloc k Input block up to 8 can be connected ( 16 points ). Input numbers are 0 to 15 from Input unit side. 0 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 2468 10 Input unit 12 14 13579 11 13 15 Displa y Power LED Indicator LED Power LED Lights on : Power for input and controlling GW is supplied.
33 32 2. EX9-PE1 VQC series SI unit for general purpose output block ( EX500-Q 02 ) Dimensions ( unit : mm ) 21.2 59.8 72.6 21 26.7 22.2 43.2 1. EX9-OET1/EX9-OET2/ EX9-OEP1/EX9-OEP2 21.2 59.8 80.3 22.2 43.2 21 26.7 PWR PWR 2. EX9-PE1 Power supply connector 1 Unused Power input connector 2 Supplies power for output devices.
35 34 Wiring Output wiring Connect output devices to the output connectors. EX9-OET1/EX9-OET2/ EX9-OEP1/EX9-OEP2 output connectors M12, 5-pin, socket NOTE Mount a waterproof cap to each unused connector. The proper use of waterproof cap can achieve IP65 Enclosure.
37 36 M12, 5-pin, reverse key, socket Po wer suppl y wiring When combining EX9-OEP1 ( or EX9-OEP2 ) and EX9-PE1 and using external power supply, connect the power supply to the power input connector of EX9-PE1. When selecting power supply, refer to "Handling precautions" ( page 3 ) in this manual.
39 38 Displa y 1. EX9-OET1/EX9-OET2/EX9-OEP1/EX9-OEP2 0 Lights on : Output ( OUT 0 ) is ON. Lights off : Output ( OUT 0 ) is OFF. 1 Lights on : Output ( OUT 1 ) is ON. Lights off : Output ( OUT 1 ) is OFF. Display Description PWR PWR 2. EX9-PE1 PWR Lights on : Power is supplied from external power supply.
41 40 NOTE Tighten the waterproof cap by the specified tightening torque. ( 0.05N m for M8, 0.1N m for M12 ) Waterproof cap Mounted on unused ports of GW unit, input block, power block and output block. The proper use of this waterproof cap can achieve IP65 Enclosure.
43 42 MS LED status Normal status : Lit in green Fatal failure : Lit in red 1 The effect of noise is possible. Check the installation conditions. If the trouble cannot be solved even if the installation conditions are checked, contact our sales branch.
Ein wichtiger Punkt beim Kauf des Geräts SMC Networks EX500-GEN1 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie SMC Networks EX500-GEN1 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für SMC Networks EX500-GEN1 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von SMC Networks EX500-GEN1 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über SMC Networks EX500-GEN1 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon SMC Networks EX500-GEN1 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von SMC Networks EX500-GEN1 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit SMC Networks EX500-GEN1. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei SMC Networks EX500-GEN1 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.