READ AND S A VE THESE INSTRUCTIONS Skuttle ® Indoor Air Quality P r oducts Model 60-Series High-Capacity Steam Humidifiers (Models 60-1, F60-1, 60-2 and F60-2) ` W arranty ` Installation Instructions ` Operating and Maintenance Instructions CONTRAC T OR: Read these instructions before installing or servicing humidifie r .
T ABLE OF C ONTENTS Page Thank Y ou! . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 W arranty V alidation Notice (I MPORT ANT ! P LEASE READ .) . . . . . . . . . . . . . 4 Skuttle ® Limited One-Y ear Product W arranty .
L IST OF F IGURES Page Figure 1: Duct Edge Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Figure 2: External Side Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Figure 3: Duct Center Mount . . . . . . .
Thank you for purchasing a Skuttle whole-house Steam Humidifier . We appreciate your business and consider you a valued customer . We sincerely hope you are satisfied with our product and its performance. Skuttle is the oldest manufacturer of residential humidifiers, having been in business since 1917.
5 Skuttle ® Limited One-Y ear Product W arranty This limited one-year warranty covers this Skuttle product as designated on the return portion of the W arranty Registration Card, excluding wiring, plumbing and installation.
6 capacity; or has been altered in any such way that its performance is affected. There is no warranty due to neglect, alteration or ordinary wear and tear .
7 CONTRACT OR How to Install a Skuttle Model 60-Series Steam Humidifier NOTES: This humidifier must be installed by a qualified professional contractor . Failure to comply with this requirement may nullify the warranty . Read all instructions before beginning installation of the humidifier .
8 T ools and Materials Needed 1. Safety goggles 2. T in snips or aviation snips 3. Electric drill 4. 3/8" and 7/64" drill bits 5. Pliers 6. Screwdriver (medium flat point and Phillips #1) 7. Level 8. Hammer 9. Small adjustable wrench 10. Center punch 11 .
9 CONTRACT OR Selecting a Location 1. For most installations, mount the humidifier under the horizontal warm air supply duct. As an alternative, the unit can be mounted on a vertical plenum using a fabricated transition for support. (See “Mounting the Humidifier”, pgs.
10 Mounting the Humidifier Figure 1 - Duct Edge Mount Option A: Duct Edge Mount Option A is the preferred method of mounting because it requires the least amount of duct reinforcement to support the humidifier and keep it level. A duct width of at least 10 inches is necessary .
11 CONTRACT OR 3. Remove the template. 4. Cut two (2) pieces of S-Cleat 8" long and one (1) piece 10-1/2" long. 5. Place the 8" long S-Cleats on the narrow sides of the opening in the duct, with the slots protruding down and out.
12 Option B: External Side Mount Figure 2 - External Side Mount Option B requires a transition to be made and usually needs duct reinforcement to hold the humidifier securely in place (see Figure 2). NOTE: For this configuration, the humidifier is mounted on the outside of the plenum, rather than the inside, so as not to restrict airflow .
13 CONTRACT OR 5. Cut two (2) pieces of S-Cleat 8" long and one (1) piece 10-1/2" long. 6. Place the 8" long S-Cleats on the narrow sides of the opening in the duct, with the slots protruding down and out.
14 Option C: Duct Center Mount Figure 3 – Duct Center Mount Option C requires duct reinforcement to hold the humidifier securely in place (see Figure 3). DANGER: W ear safety glasses when cutting or drilling. Do not cut into any air conditioning or electrical accessories during installation.
15 CONTRACT OR 5. Place the 8" long S-Cleats on the narrow sides of the opening in the duct, with the slots protruding down and out. Place the 10-1/2" long S-Cleat on the longer side, closest to the center of the duct, in the same way as the shorter S-Cleats.
16 Option D: Internal Side Mount Figure 4 - Internal Side Mount Option D requires a transition to be made and usually needs duct rein- forcement to hold the humidifier securely in place (see Figure 4). DANGER: W ear safety glasses when cutting or drilling.
17 CONTRACT OR 6. Adjust the water level. (See #8 in “How T o Maintain a Skuttle Steam Humidifier”, pg. 25.) 7. Slide the humidifier into the hole, making sure all wires and con- nections are outside the duct. 8. Align the holes and secure the humidifier to the transition.
18 Connecting to a Power Source When selecting a location for mounting the humidifier , make sure that electrical connections can be made without the use of an extension cord. CAUTION: The electrical receptacle must be rated at the correct voltage and amperage, or hazardous conditions could result.
CONTRACT OR W iring the Air Mover Figure 5 - Wiring diagram for Model 60-1 and F60-1 (120 volt) Steam Humidifiers. Figure 6 - Wiring diagram for Model 60-2 and F60-2 (240 volt) Steam Humidifier .
20 CAUTIONS: Be careful not to activate, deactivate or alter the normal functions of the home’s heating and cooling system, except to coordinate the systems’ air moving operation with the humidifier .
21 CONTRACT OR Figure 8B - T ypical wiring for a humidifier in a single-speed air mover application without air conditioning (switching through a G contactor ).
22 Plumbing and Setting the W ater Level NOTE: Use a copper tubing only to plumb this humidifier . 1. Select the nearest cold water pipe and install the saddle connector and needle valve (provided) by following the instructions supplied with the valve.
23 CONTRACT OR CAUTION: To prevent valve seat damage, never adjust the humidifier's water level without supporting the float arm. Make adjustments in small increments. •T o raise the water level, push down in the center of the float arm (see Figure 9, below).
24 10. Check the two compression fittings – one at the saddle valve, the other at the float valve. Stop any leakage by tightening the fitting. 11 . Connect the humidifier's overflow provision to a suitable waste drain. •A standard garden hose or a 3/8" N.
CONTRACT OR How T o Maintain a Skuttle Steam Humidifier Because the Skuttle steam humidifier is designed to emit mineral-free moisture into the air , the unit should be cleaned and serviced every two- to-four months. Harder water , colder weather and/or higher humidistat settings will increase the frequency of cleaning and service.
26 9. Remount the humidifier and make all electrical and plumbing recon- nections. Check for leaks or overflow . Set the humidistat as directed in the humidistat instructions.
P ROBLEM E VIDENCE S OLUTIONS ( S ) Low Humidity Low water level (less than • See Plumbing and Setting W ater 2-3/8" deep) Level, steps 4 & 5 No water in reservoir • T urn water on at sad.
M ODELS 60-1 AND F60-1 I TEM P ART N AME P ART N O . A Heating Element 1500W 120 V olt (incl. mounting hardware) 000-0430-055 B Safety Float 000-0814-132 CW ater Supply Float V alve 000-1731-012 D Stainless Steel Float A00-1309-012 ET ransformer 120 V olt to 24 Volt 000-0814-133 F Humidifier Control Relay 000-0431-031 G 6-pc.
29 CONTRACT OR M ODELS 60-2 AND F60-2 I TEM P ART N AME P ART N O . A Heating Element 2000W 240 V olt (incl. mounting hardware) 000-0430-056 B Safety Float 000-0814-132 CW ater Supply Float V alve 000-1731-012 D Stainless Steel Float A00-1309-012 ET ransformer 240 V olt to 24 Volt 000-0814-133 F Humidifier Control Relay 000-0431-031 G 6-pc.
30 Maintenance Record H UMIDIFIER H UMIDIFIER P ART ( S ) D AT E C LEANED ( ✔ )R EP AIRED ( ✔ )R EPLACED O THER T able 4.
31 HOMEOWNER How Y our Humidifier Works Y our Skuttle Steam Humidifier supplies moist air to your home much the same way as outdoor air is humidified. On a warm summer day , the sun’s heat evaporates water from puddles, streams, rivers, oceans, etc.
32 How T o Extend the Life of Y our Humidifier Mineral buildup on the humidifier ’s heating element is harmful to the unit. Therefore, routine maintenance is vital to the effectiveness and longevity of your humidifier . The normal service interval will vary from one-to-three months (i.
33 GENERAL INFO F AQs about IAQ (Frequently Asked Questions about Indoor Air Quality) Why do I need a humidifier? More and more homeowners are realizing that, during the winter months, they live in a “sick house”. Family members suffer from dry , itchy skin, parched throats and annoying coughs.
34 Should I run my humidifier during the summer months? Because, in most areas of the country , summer air is naturally more humid, it’s not necessary to humidify your home until colder weather sets in. NOTE: For additional answers to your questions, visit our website at www .
35 GENERAL INFO Skuttle ® Automatic Flushing Timer Flushes Drum and Reservoir T ype Humidifiers Every 12 Hours The Skuttle Flushing Timer . . . • Automatically flushes the humidifier water pan with.
36 Skuttle ® Model 216 Make-Up Air Control Provides Y ear-Round, Filtered Fresh Air The Skuttle Make-Up Air Control . . . • Draws outside air into the furnace, where it is filtered, heated or coole.
37 GENERAL INFO Skuttle ® High-Efficiency Air Cleaners Help Homeowners Breathe Easier Skuttle Air Cleaners . . . •T rap most of the in-home, airborne contaminants that are potentially harmful to yo.
38 The Skuttle ® “Happy House” – Y our Assurance of Enhanced IAQ Healthful indoor air (often called indoor air quality or IAQ ) is significantly cleaner than the air in many of today’s homes. It also contains appro- priate levels of moisture and fresh outside air to aid the health and com- fort of residents.
39 GENERAL INFO V entilation A primary cause of “sick house syndrome” is a negative air pressure buildup, resulting from a lack of fresh-air exchanges throughout the home.
If you have questions about your Skuttle humidifier , or to learn which Skuttle IAQ products are right for your home, contact your local heating and air conditioning contractor: Skuttle ® Indoor Air Quality Pr oducts 101 Margaret Street, Marietta, OH 45750 Phone: (800) 848-9786; Fax: (740) 373-9565 Email: customerservice@skuttle.
Ein wichtiger Punkt beim Kauf des Geräts Skuttle Indoor Air Quality Products 60-2, F60-2 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Skuttle Indoor Air Quality Products 60-2, F60-2 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Skuttle Indoor Air Quality Products 60-2, F60-2 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Skuttle Indoor Air Quality Products 60-2, F60-2 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Skuttle Indoor Air Quality Products 60-2, F60-2 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Skuttle Indoor Air Quality Products 60-2, F60-2 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Skuttle Indoor Air Quality Products 60-2, F60-2 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Skuttle Indoor Air Quality Products 60-2, F60-2. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Skuttle Indoor Air Quality Products 60-2, F60-2 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.