Owner’ s Manual Home Humidier Models 2000, 2001, 2002, 2100, 2101 and 2102 Includes Safety , Operating and Main- tenance Instructions plus 5-Y ear Warranty ©Skuttle Mfg.
Skuttle ® Indoor Air Quality Products 101 Margaret St., Marietta, OH 45750 800-848-9786 (US only) or 740-373-9169 customerservice@skuttle.com • www .
1 Contents Congratulations ..................................................................................... 2 Experience that Works for Y ou .............................................................. 2 Owner Responsibility ...................
2 Congr atula tions ... on your purchase of a Skuttle High-Capacity Flow-Thru Humidie—one of the nest home humidies made! Models 2000 and 2100* Bypass Flow-Thru Humidies Models .
3 overall parts make Skuttle one of the simplest, most trouble-free humidiers you can buy . Owner R esponsibility Skuttle’s obligation to honor the warranty on this humidier is depen dent u.
4 Models 2002 and 2102. These models operate identically to the previous models, except that warm air is forced through the humidier cabinet by a humidier fan rather than by the furnace blower . Humidistat Operating Instructions Impor tant Notes: Models 2000, 2001 and 2002 come with a standard humidistat.
5 Recommended Humidistat Settings Outside T emperature Recommended Setting Outside T emperature Recommended Setting -20ºF (-29ºC) 15 (Low) 10ºF (-12ºC) 30 (Medium) -10ºF (-23ºC) 20 (Medium-Low) .
6 T ilt out the distribution tray and evaporator pad assembly . 3. W ash all plastic and metal parts (except electrical parts and compo- nents) in humidier cleaner or a 50 percent solution of vinegar and water . If cleaning is not sufcient, replace the evaporator pad.
7 R eplacement Par ts and Ser vice If you need parts or service to maintain the superior performance of your FlowThru Humidier , follow these procedures: Contact the heating and air conditioning contractor who installed your unit.
8 Models 2000 and 2100 R eplacement Par ts Dia gr am.
9 Models 2000 and 2100 R eplacement Par ts List Key No. Part No. Std. Pkg. Description 1 000-1730-094 1 Mounting Base 2 000-0602-055 1 Drip T ray 3 000-1317-091 1 Wick 4 A00-1730-124 1 Side Piece w/Da.
10 Models 2001 and 2101 R eplacement Par ts Dia gr am.
1 1 Models 2001 and 2101 R eplacement Par ts List Key No. Part No. Std. Pkg. Description 1 000-1730-091 1 Mounting Base 2 000-0602-055 1 Drip T ray 3 000-1317-091 1 Wick 4 A00-1730-124 1 Side Piece w/.
12 Models 2002 and 2102 R eplacement Par ts Dia gr am.
13 Models 2002 and 2102 R eplacement Par ts List Key No. Part No. Std. Pkg. Description 1 000-1730-091 1 Mounting Base 2 000-0602-055 1 Drip T ray 3 000-1317-091 1 Wick 4 A00-1730-089 1 Solid Side Pie.
14 Skuttle Limited Product War r anty NO TE: Models 2000, 2001, 2100 and 2101 ae waanted fo ve years; Models 2002 and 2102 are warranted for one year .
15 SK UTT LE WI LL RE CEI VE, F REI GHT PRE P AI D, ON L Y RE MOV ABL E P AR TS OR CO MPO NEN TS OF SU CH DEF ECT IVE P ROD UCT S. This limited warranty does not apply to any part or component that is.
101 Margaret Street • Marietta, OH 45750 800-848-9786 • 740-373-9169 customerservice@skuttle.com • www .skuttle.com Contractor Stamp Her e Model 2000 Model 2001 Model 2002 Model 2100 Model 2101 Model 2102 Serial No.
Ein wichtiger Punkt beim Kauf des Geräts Skuttle Indoor Air Quality Products 2102 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Skuttle Indoor Air Quality Products 2102 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Skuttle Indoor Air Quality Products 2102 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Skuttle Indoor Air Quality Products 2102 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Skuttle Indoor Air Quality Products 2102 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Skuttle Indoor Air Quality Products 2102 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Skuttle Indoor Air Quality Products 2102 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Skuttle Indoor Air Quality Products 2102. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Skuttle Indoor Air Quality Products 2102 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.