INSTALLATION GUIDE ENGLISH DEUTSC H ITALIANO ESPAÑOL FRAN Ç AIS AXIS Electrical Safety Kit A 120 V AC AXIS Electrical Safety Kit B 230 V AC.
Electrical Safety: Low Voltage Directive (LVD) Europe - This equipment complies with the Low Voltage Directive 2006/95/EC. Safety For safety informati on regarding the components of this kit, see Technical Specifications, o n page 15.
ENGLISH Safeguards Please read through this Installation Guide carefully be fore installing the Axis product. Ke ep the Installa tion Guide for further reference . • Store the Axis product in a dry and ventilated environment. • Avoid exposing the Axis product to vibration, shocks or heavy pressure.
.
AXIS Electr ical Safety Kit A/B Page 5 ENGLISH AXIS Electrical Safety Kit A/B Installation Guide This Installation Guide provides instru ctions for installing AXIS Electrical Safety Kit A 120 V AC and AXIS Electr ical Safety Kit B 230 V AC in AXIS T98A-VE Surveillance Cabinet Series.
Page 6 AXIS Electr ical Safet y Kit A/B Hardware Overview In this document PE, Protective Earth, and Ground are referred to as ground. 1 2 3 4 5 7 6 1 MCB fuse 4 A (Circuit bre aker) 2 Surge protector.
AXIS Electr ical Safety Kit A/B Page 7 ENGLISH Connection Diagram • If an external protective bonding wire is used it is recom- mended to have a miminum area of 6 mm 2 (AWG 10) for indoor use and a minimum area of 10 mm 2 (AWG 8) for outdoor use.
Page 8 AXIS Electr ical Safet y Kit A/B • Check the surge protector after lig htning strikes and replace if required. See Replace the Surge Protector, on page 14.
AXIS Electr ical Safety Kit A/B Page 9 ENGLISH Install the Devices • The electrical connections and conduit installat ions shall be made by a certified electricia n and in compliance with local regulations. • Risk of electric shock. The main s supply shall be disconnected during installation.
Page 10 AXIS Electrical Safety Kit A/B Example: AXIS Electrical Safety Kit A 120 V AC 1 0 L N PE 4 A 1 6 7 9 8 2 3 4 5 1 Circuit breaker 2 Surge protector 3 Terminal block – feed-through (blue) 4 Te.
AXIS Elect rical Safe ty Kit A/B Page 11 ENGLISH Example: AXIS Electrical Safety Kit B 230 V AC PE 1 0 LN 4 A 1 6 7 9 8 2 3 4 5 1 Circuit breaker 2 Surge protector 3 Terminal block – feed-through (b.
Install the Door Swit ch The door switch included with the elec trical safety kit can be connected to the I/O port on a camera or an I/O device. See the camera’s Installation Guide and User Manual for information about connecting and configuring the camera’s I/O port.
AXIS Elect rical Safe ty Kit A/B Page 13 ENGLISH 4. If connecting to the I/O port on a camera, route the door switch cable through a cable gasket and at tach the cabl e gaske t to one of the cable holes in the cabinet door. 5. Secure the cable to the door using the supplied cable clip.
Page 14 AXIS Electrical Safety Kit A/B Replace the Surge Protector The surge protector gets worn out by surges. The window on the surge protector shows the status of the device.
AXIS Elect rical Safe ty Kit A/B Page 15 ENGLISH Technical Specifications General Function/group Item Specifications General Environment In a cas ing for indoor or outdoor use Pollution Degree 2 Door .
Page 16 AXIS Electrical Safety Kit A/B AXIS Electrical Safety Kit A 120 V AC Function/group Item Specifications Circuit breaker/fuse Rated current 4A at 30°C (8 6°F) Operating voltage Max 277 V AC Rated frequencey 50/60 Hz Rated short- circuit capacity 10 kA Tripping curve K Approvals IEC/EN 60947-2 UL 489 CSA 22.
AXIS Elect rical Safe ty Kit A/B Page 17 ENGLISH AXIS Electrical Safety Kit B 230 V AC Function/group Item Specifications Circuit breaker/fuse Rated current 4A at 30°C (86°F) Operating voltage Max 253 V AC Rated frequencey 50/60 Hz Rated short- circuit capacity 6 kA Tripping curve C Approvals IEC/EN 60898-1 IEC/EN 60947-2 UL 1077 CSA 22.
Page 18 AXIS Electrical Safety Kit A/B Warranty For information about Axis’ produ ct warranty and thereto related information, see www.axis.com/warranty.
.
Installation Guide Ver.2.10 AXIS Electrical Safety Kit A/B Printed: October 2012 © Axis Communications AB, 2012 Part No. 48993.
Ein wichtiger Punkt beim Kauf des Geräts Axis Communications B 230 V AC (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Axis Communications B 230 V AC noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Axis Communications B 230 V AC - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Axis Communications B 230 V AC reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Axis Communications B 230 V AC erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Axis Communications B 230 V AC besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Axis Communications B 230 V AC verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Axis Communications B 230 V AC. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Axis Communications B 230 V AC gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.