Siemens X005

64 Seiten·1.4 MB·Switch·PDF·ENFRITNLJA
Siemens X005
Inhaltsverzeichnis 27 Abschnitte Preface · Preface · Introduction · Introduction · … AnzeigenAusblenden
Page 1 of the Siemens X005 user manual
Seite 1 · Zum Vergrößern klicken
Seite 1

This manual contains notices which you should observe to ensure your own personal safety as well as to avoid property damage. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring to property damage only have no safety alert symbol. Depending on the danger level ,the notices are displayed in descending order as follows.

indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.

indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.

used with the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.

used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property damage.

used without the safety alert symbol indicates a potential situation which, if not avoided, may result in an undesirable result or state.

When several danger levels apply, the notices of the highest level (lower number) are always displayed. If a notice refers to personal damages with the safety alert symbol, then another notice may be added warning of property damage.

The device/system may only be set up and operated in conjunction with this documentation. Only qualified personnel should be allowed to install and work on the equipment. Only qualified personnel should be allowed to install and work on the equipment. Qualified persons are defined as persons who are authorized to commission, to earth, and to tag circuits, equipment and systems in accordance with established safety practices and standards.

Please note the following:

This device and its components may only be used for the applications described in the catalog or technical description, and only in connection with devices or components from other manufacturers approved or recommended by Siemens. This product can only function correctly and safely if it is transported, stored, set up and installed correctly, and operated and maintained as recommended.

All designations marked with ® are registered trademarks of Siemens AG. Other designations in this documentation might be trademarks which, if used by third parties for their purposes, might infringe upon the rights of the proprietors.

Copyright Siemens AG, 2005. All rights reserved Reproduction, transmission or use of this document or its contents is not permitted without express written authority. Offenders will be liable for damages. All rights, including rights created by patent grant or registration of a utility model or design, are reserved.

Disclaimer of Liability We have checked the contents of this manual for agreement with the hardware and software described. Since deviations cannot be precluded entirely, we cannot guarantee full agreement. However, the data in the manual are reviewed regularly, and any necessary corrections will be included in subsequent editions. Suggestions for improvement are welcomed.

Siemens AG Automation and Drives Group P.O. Box 4848, D-90327 Nuremberg (Germany)

Siemens AG 2005 Technical data subject to change Siemens Aktiengesellschaft A2B00051528A

Show 4 more labels / short text on this page
Safety Guidelines · Qualified Personnel · Intended Use · Trademarks
Page 3 of the Siemens X005 user manual
Seite 3 · Zum Vergrößern klicken
Seite 3
Page 3 of the Siemens X005 user manual
Page 4 of the Siemens X005 user manual — SIMATIC NET SCALANCE X005 6GK5005-0BA00-1AA3
Seite 4 · Zum Vergrößern klicken
Seite 4

Preface 1

1.1 Preface

Purpose of the Commissioning Manual

This commissioning manual supports you when commissioning the unmanaged Industrial Ethernet entry level switch SCALANCE X005.

Validity of this Commissioning Manual

This commissioning manual is valid for the following devices:

SIMATIC NET SCALANCE X005 6GK5005-0BA00-1AA3

The “SIMATIC NET Industrial Ethernet Twisted Pair and Fiber Optic Networks” manual contains additional information on other SIMATIC NET products that you can operate along with the SCALANCE X005 switch in an Industrial Ethernet network.

You can download this network manual from Customer Support on the Internet under entry number 1172207.

This commissioning manual is intended for personnel involved in the commissioning of the SCALANCE X005 switch in a network.

The SCALANCE X005 device meets the requirements for the CE mark. For detailed information, refer to the Chapter “Notes on the CE Mark”.

Further Documentation · Audience · Standards and Approvals

Page 5 of the Siemens X005 user manual — Preface
Seite 5 · Zum Vergrößern klicken
Seite 5
Page 5 of the Siemens X005 user manual — Preface
Page 6 of the Siemens X005 user manual — 2.1 Introduction
Seite 6 · Zum Vergrößern klicken
Seite 6

Introduction 2

2.1 Introduction

This chapter provides you with an overview of the functions of the unmanaged Industrial Ethernet entry level switch SCALANCE X005.

The SCALANCE X005 switch enables the cost-effective installation of small Industrial Ethernet bus or star structures with switching functionality. The devices are designed for installation in a switching cubicle.

It is not possible to use the SCALANCE X005 switch in a redundant ring since it does not support the redundancy function.

The requirements of EN61000-4-5, surge test on power supply lines, are met only when a Blitzductor VT AD 24V type no. 918 402 is used.

ManufacturerDEHN+S Ö HNE GmbH+Co.KG Hans Dehn Str.1 Postfach 1640 D-92306 Neumarkt, Germany

The specified approvals apply only when the corresponding mark is printed on the product.

What Is Possible?

Page 7 of the Siemens X005 user manual — Introduction
Seite 7 · Zum Vergrößern klicken
Seite 7
Page 7 of the Siemens X005 user manual — Introduction
Page 8 of the Siemens X005 user manual — 3.1 Network Topologies
Seite 8 · Zum Vergrößern klicken
Seite 8

Network Topologies 3

3.1 Network Topologies

Switching technology allows extensive networks to be set up with numerous nodes and simplifies network expansion.

Which network topologies can be implemented?

With the SCALANCE X005 device, bus and star topologies can be implemented.

Siemens X005 — 3.1 Network Topologies diagram (page 8)
Abb. 1 · 3.1 Network Topologies
Siemens X005 — 3.1 Network Topologies diagram (page 8)
Abb. 2 · 3.1 Network Topologies

Figure 3-1 Bus topology with SCALANCE X005

Bus Topology

Page 9 of the Siemens X005 user manual — Network Topologies
Seite 9 · Zum Vergrößern klicken
Seite 9

Network Topologies 3.1 Network Topologies

Siemens X005 — Network Topologies diagram (page 9)
Abb. 3 · Network Topologies

Figure 3-2 Star topology with SCALANCE X005

Star Topology

Page 10 of the Siemens X005 user manual — 4.2 SCALANCE X005 Unpacking and Checking
Seite 10 · Zum Vergrößern klicken
Seite 10

Product Characteristics 4

4.1 Components of the SCALANCE X005 Product

What ships with the SCALANCE X005 ?

  • SCALANCE X005 device
  • 2-pin plug-in terminal block
  • Commissioning manual (this document)

4.2 SCALANCE X005 Unpacking and Checking

1. Make sure that the package is complete
2. Check all parts for transport damage.

Do not use any parts that show evidence of damage!

If the SCALANCE X005 device is operated in ambient temperatures between 60°C - 65°C, the temperature of the device housing may be higher than 65°C.

The subject unit must be located in a Restricted Access Location where access can only be gained by SERVICE PERSONNEL or by USERS who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken when operated in an ambient temperature of 60°C - 65°C.

Unpacking, Checking

Page 11 of the Siemens X005 user manual — 4.3 SCALANCE X005 Product Characteristics
Seite 11 · Zum Vergrößern klicken
Seite 11

Product Characteristics 4.3 SCALANCE X005 Product Characteristics

4.3 SCALANCE X005 Product Characteristics

SCALANCE X005 features five RJ-45 jacks for the connection of DTEs or other network segments.

Siemens X005 — 4.3 SCALANCE X005 Product Characteristics diagram (page 11)
Abb. 4 · 4.3 SCALANCE X005 Product Characteristics

Figure 4-1 SCALANCE X005

Possible Attachments

Page 12 of the Siemens X005 user manual — 4.4 SCALANCE X005 TP Ports
Seite 12 · Zum Vergrößern klicken
Seite 12

Product Characteristics 4.4 SCALANCE X005 TP Ports

4.4 SCALANCE X005 TP Ports

Siemens X005 — 4.4 SCALANCE X005 TP Ports diagram (page 12)
Abb. 5 · 4.4 SCALANCE X005 TP Ports

Figure 4-2 RJ-45 connector pinout

Pin 8 NC Pin 7 NC Pin 6 TD- Pin 5 NC Pin 4 NC Pin 3 TD+ Pin 2 RD- Pin 1 RD+

On SCALANCE X005, the twisted pair ports are implemented as RJ-45 jacks with MDI-X assignment (Medium Dependent Interface–Autocrossover) of a network component.

TP cords or TP-XP cords with a maximum length of 10 m can be connected at the RJ-45 TP port.

Depending on the cable type, a maximum total cable length of 100 m is permitted between two devices with the IE FC cables and IE FC RJ-45 plugs 180.

Autonegotiation means the automatic detection of the functionality of the port at the opposite end. Using autonegotiation, repeaters or DTEs can detect the functionality available at the

Show 4 more labels / short text on this page
Connector Pinout · RJ-45 jack · Pin number Pinout · Autonegotiation
Page 13 of the Siemens X005 user manual — SCALANCE X005 TP Ports
Seite 13 · Zum Vergrößern klicken
Seite 13

Product Characteristics 4.4 SCALANCE X005 TP Ports

port of a partner device allowing automatic configuration of different types of device. With autonegotiation, two components connected to a link segment can exchange parameters and set themselves to match the supported communication functionality.

Devices not supporting autonegotiation must be set to 100 Mbps/ half duplex or 10 Mbps half duplex.

If the receive line pair is incorrectly connected (RD+ and RD- switched), the polarity is automatically adapted.

The SCALANCE X005 is a plug and play device which does not require settings for commissioning.

MDI /MDIX Autocrossover Function

The advantage of the MDI /MDIX autocrossover function is that straight-through cables can be used throughout and crossover Ethernet cables are unnecessary. This prevents malfunctions resulting from mismatching send and receive wires. This makes installation much easier for the user.

The SCALANCE X005 device supports the MDI / MDIX autocrossover function.

Fixed configured ports of partner stations must be set to 100 Mbps/ half duplex or 10 Mbps half duplex.

Please note that a direct connection of two ports or an unintentional connection via several switches causes an unpermissible loop which may cause network overload and network failures.

Auto polarity exchange

Page 14 of the Siemens X005 user manual — 4.6 SCALANCE X005 LEDs
Seite 14 · Zum Vergrößern klicken
Seite 14

Product Characteristics 4.5 SCALANCE X005 Power Supply

4.5 SCALANCE X005 Power Supply

The power supply is connected using a 2-pin plug-in terminal block. The power supply is connected over a high resistance with the enclosure to allow an ungrounded setup. The power supply is non-floating.

Siemens X005 — 4.5 SCALANCE X005 Power Supply diagram (page 14)
Abb. 6 · 4.5 SCALANCE X005 Power Supply
Siemens X005 — 4.5 SCALANCE X005 Power Supply diagram (page 14)
Abb. 7 · 4.5 SCALANCE X005 Power Supply

Figure 4-3 Power supply Figure 4-4 Connector pinout

Pin number Pinout Pin 1 M (Mass) Pin 2 L+ (+18 - 32V DC)

The SCALANCE X005 device is designed for operation with safety extra-low voltage. This means that only safety extra-low voltages (SELV) complying with IEC950/EN60950/ VDE0805 can be connected to the power supply terminals.

The power supply unit to supply SCALANCE X005 must comply with NEC Class 2 (voltage range 18 - 32 V, current requirement 350 mA).

Never connect SCALANCE X005 to AC voltage. Never connect SCALANCE X005 to DC voltage higher than 32 V DC.

4.6 SCALANCE X005 LEDs

Power indicator (green LED)

The status of the power supply is indicated by a green LED:

Lit green Power supply is connected.

Not lit Power supply is not connected or

Power Supply · Status Meaning

Page 15 of the Siemens X005 user manual — 4.7 SCALANCE X005 Technical Specifications
Seite 15 · Zum Vergrößern klicken
Seite 15

Product Characteristics 4.7 SCALANCE X005 Technical Specifications

Port status indicator (green/yellow LEDs)

The status of the ports is indicated by five LEDs:

Port 1 to 5 LED lit green TP link exists, no data reception

Port 1 to 5 LED lit yellow TP link exists, data received at TP port

Port 1 to 5 LED flashes yellow Test phase during power on

4.7 SCALANCE X005 Technical Specifications

Technical Specifications of SCALANCE X005

Attachment of DTEs or network components over twisted pair

5xRJ-45 sockets with MDI-X pinning 10/100 Mbps (half/ full duplex)

Connector for power supply 1 x 2-pin plug-in terminal block

Power supply Power supply DC 18 .. 32 V safety extra-low voltage (SELV)

Power loss at DC 24 V (typ.) 2 W

Current consumption at rated voltage (typ.) 80 mA

Overvoltage protection at input PTC resetable fuse (0.5 A / 60 V)

Connection over Industrial Ethernet FC TP cables

Industrial Ethernet FC TP standard cable with IE FC RJ-45 plug 180 or over Industrial Ethernet FC outlet RJ-45 with 0 - 90 m Industrial Ethernet FC TP standard cable + 10 m TP cord Industrial Ethernet FC TP marine/trailing cable with IE FC RJ-45 plug 180 or 0 - 75 m Industrial Ethernet FC TP marine/trailing cable + 10 m TP cord

Aging time 375 seconds

Show 6 more labels / short text on this page
Status Meaning · Ports · Electrical Data · Permitted Cable Lengths · 0 –100 m · 0 –85 m
Page 16 of the Siemens X005 user manual — SCALANCE X005 Technical Specifications
Seite 16 · Zum Vergrößern klicken
Seite 16

Product Characteristics 4.7 SCALANCE X005 Technical Specifications

Siemens X005 — SCALANCE X005 Technical Specifications diagram (page 16)
Abb. 8 · SCALANCE X005 Technical Specifications

Operating altitude 2000 m at max 46 °C ambient temperature 3000 m at max. 40 °C ambient temperature

RF interference level EN 61000-6-2 Class A (replaces EN 50081-2 Class A) EN 61000-6-2 Class B with split toroidal core on the lines Manufacturer: Würth Elektronik - type: 742 711 31

Dimensions (W x H x D) in mm 40 x 125 x 124

Installation options DIN rail S7-300 standard rail Wall mounting

“Industrial Ethernet TP and Fiber Optic Networks” manual

IE FC RJ-45 plug 180 pack of 1 6GK1 901-1BB10-2AA0

IE FC RJ-45 plug 180 pack of 10 6GK1 901-1BB10-2AB0

IE FC RJ-45 plug 180 pack of 50 6GK1 901-1BB10-2AE0

Page 17 of the Siemens X005 user manual — SCALANCE X005 Technical Specifications
Seite 17 · Zum Vergrößern klicken
Seite 17

Product Characteristics 4.7 SCALANCE X005 Technical Specifications

The number of connected SCALANCE X Industrial Ethernet switches influences the frame propagation time.

When a frame passes through SCALANCE X005, it is delayed by the store and forward function of the switch: - With a 64 byte frame length by approx. 10 µs (at 100 Mbps) - With a 1500 byte frame length by approx. 130 µs (at 100 Mbps) This means that the more SCALANCE X005 devices are passed through, the higher the frame propagation time will be.

Page 18 of the Siemens X005 user manual — 5.1 Installation
Seite 18 · Zum Vergrößern klicken
Seite 18

Installation and Maintenance 5

5.1 Installation

SCALANCE X005 can be installed in various ways:

  • Installation on a 35 mm DIN rail
  • Installation on a SIMATIC S7-300 standard rail
  • Wall mounting

When installing and operating the device, keep to the installation instructions and safety-related notices as described here and in the SIMATIC NET Industrial Ethernet Twisted Pair and Fiber Optic Networks /2/ manual.

Protect the device against exposure to direct sunlight by suitable shadowing. This avoids an undesired temperature rise of the device and prevents premature ageing of device and cabling.

Types of installation

Page 19 of the Siemens X005 user manual — 5.2 Installation on a DIN Rail
Seite 19 · Zum Vergrößern klicken
Seite 19

Installation and Maintenance 5.2 Installation on a DIN Rail

5.2 Installation on a DIN Rail

Install the SCALANCE X005 on a 35 mm DIN rail complying with DIN EN 50022.

1. Place the upper catch of the device over the top of the rail and then push in the lower part of the device against the rail until it clips into place.
2. Install the electrical connecting cables.
Siemens X005 — 5.2 Installation on a DIN Rail diagram (page 19)
Abb. 9 · 5.2 Installation on a DIN Rail
Siemens X005 — 5.2 Installation on a DIN Rail diagram (page 19)
Abb. 10 · 5.2 Installation on a DIN Rail
Siemens X005 — 5.2 Installation on a DIN Rail diagram (page 19)
Abb. 11 · 5.2 Installation on a DIN Rail

Figure 5-1 SCALANCE X005 installation on a DIN rail (35 mm)

To remove SCALANCE X005 from the rail:

1. First disconnect the TP cables and pull out the terminal block for the power supply.
2. Use a screwdriver to release the lower rail catch of the device and pull the lower part of the device away from the rail.

Installation · Uninstalling

Page 20 of the Siemens X005 user manual — 5.3 Installation on a Standard Rail
Seite 20 · Zum Vergrößern klicken
Seite 20

Installation and Maintenance 5.3 Installation on a Standard Rail

Siemens X005 — Installation on a Standard Rail diagram (page 20)
Abb. 12 · Installation on a Standard Rail
Siemens X005 — Installation on a Standard Rail diagram (page 20)
Abb. 13 · Installation on a Standard Rail
Siemens X005 — Installation on a Standard Rail diagram (page 20)
Abb. 14 · Installation on a Standard Rail

Figure 5-2 SCALANCE X005 removing from a DIN rail (35 mm)

5.3 Installation on a Standard Rail

Installation on a SIMATIC S7-300 Standard Rail

1. Place the upper guide at the top of the SCALANCE housing in the S7 standard rail.
2. Screw the SCALANCE X005 device to the lower part of the standard rail.
3. Install the electrical connecting cables.
1. First remove all connected cables.
2. Unscrew the screw fittings at the lower part of the standard rails and subsequently pull the device away from the standard rail.

Uninstalling

Page 21 of the Siemens X005 user manual — 5.4 Wall Mounting
Seite 21 · Zum Vergrößern klicken
Seite 21

Installation and Maintenance 5.4 Wall Mounting

Siemens X005 — Wall Mounting diagram (page 21)
Abb. 15 · Wall Mounting

Figure 5-3 SCALANCE X005 installation on a SIMATIC S7-300 standard rail

5.4 Wall Mounting

1. Use four wall plugs (6 mm diameter and 30 mm long).
2. To attach the device, use screws with a diameter of 3.5 mm and a length of 40 mm. For exact dimensions, please observe the dimension drawings in the Chapter “Dimension Drawing” of the instructions„

The wall mounting must be capable of supporting at least four times the weight of the device.

Wall Mounting

Page 22 of the Siemens X005 user manual — 5.5 Grounding
Seite 22 · Zum Vergrößern klicken
Seite 22

Installation and Maintenance 5.5 Grounding

5.5 Grounding

Installation on a DIN Rail

The device is grounded over the DIN rail.

The device is grounded over its rear panel and the neck collar screw.

The device is grounded by the securing screw in the unpainted hole.

Please note that SCALANCE X005 must be grounded over one securing screw with minimum resistance.

If the device is mounted on a non-conducting surface, it is required to install a grounding cable. The grounding cable is not included in the delivery. Connect the unpainted surface of the device to the next grounding point via the grounding cable.

S7 Standard Rail · Wall Mounting

Page 23 of the Siemens X005 user manual — 5.6 Assembling the IE FC Standard Cable
Seite 23 · Zum Vergrößern klicken
Seite 23

Installation and Maintenance 5.6 Assembling the IE FC Standard Cable

5.6 Assembling the IE FC Standard Cable

Assemble the IE FC RJ-45 plug 180 and the IE FC standard cable as follows

For information on the assembly, please refer to the instructions that ship with the IE FC RJ-45 plug 180.

The robust connectors of the nodes are designed for industry and are PROFINET-compliant. Due to the locking mechanism on the casing, they provide additional strain and torsion relief.

Siemens X005 — 5.6 Assembling the IE FC Standard Cable diagram (page 23)
Abb. 16 · 5.6 Assembling the IE FC Standard Cable
Siemens X005 — 5.6 Assembling the IE FC Standard Cable diagram (page 23)
Abb. 17 · 5.6 Assembling the IE FC Standard Cable
Siemens X005 — 5.6 Assembling the IE FC Standard Cable diagram (page 23)
Abb. 18 · 5.6 Assembling the IE FC Standard Cable
Siemens X005 — 5.6 Assembling the IE FC Standard Cable diagram (page 23)
Abb. 19 · 5.6 Assembling the IE FC Standard Cable

Figure 5-4 IE FC RJ-45 plug 180

Page 24 of the Siemens X005 user manual — Assembling the IE FC Standard Cable
Seite 24 · Zum Vergrößern klicken
Seite 24

Installation and Maintenance 5.6 Assembling the IE FC Standard Cable

Plugging the IE FC RJ-45 Plug 180

3. Plug the IE FC RJ-45 plug 180 in the twisted pair port of SCALANCE X005 or of the devices of the product lines SCALANCE X-100 or X-200 until it snaps into place.
Siemens X005 — Assembling the IE FC Standard Cable diagram (page 24)
Abb. 20 · Assembling the IE FC Standard Cable

Figure 5-5 Plugging the IE FC RJ-45 plug 180

Due to the closing shape and the latching with the PROFINET-compliant connector IE FC RJ-45 plug 180, the sleeve at the TP port of SCALANCE X005 ensures a robust, industry- standard node connection which provides additional strain and torsion relief of the twisted pair port.

Page 25 of the Siemens X005 user manual — 5.7 Maintenance
Seite 25 · Zum Vergrößern klicken
Seite 25

Installation and Maintenance 5.7 Maintenance

Unplugging the IE FC RJ-45 Plug 180

4. Unlatch the IE FC RJ-45 plug 180 by slightly pressing the latching to unplug the plug.
Siemens X005 — Maintenance diagram (page 25)
Abb. 21 · Maintenance

Figure 5-6 Unlatching the RJ-45 plug

If, for lack of space, a manual unlatching is not possible, you can also unlatch the plug with a 2.5 mm screwdriver. Subsequently you can unplug the IE FC RJ-45 plug 180 from the twisted pair port.

5.7 Maintenance

If a fault develops, please send the device to your SIEMENS service center for repair. Repairs on-site are not possible.

Maintenance

Page 26 of the Siemens X005 user manual — SIMATIC NET SCALANCE X005 6GK5005-0BA00-1AA3
Seite 26 · Zum Vergrößern klicken
Seite 26

Notes on the CE Mark 6

6.1 Notes on the CE Mark

SIMATIC NET SCALANCE X005 6GK5005-0BA00-1AA3

89/336/EEC “Electromagnetic Compatibility”

The product is designed for use in an industrial environment:

Area of Application Requirements

Noise emission Noise immunity

Industrial operation EN 61000-6-42001 (replaces EN 50082-2)
EN 61000-6-22001 (replaces EN 50081-2)

The product meets the requirements if you keep to the installation instructions and safety- related notices as described here and in the manual “SIMATIC NET Industrial Ethernet Twisted Pair and Fiber Optic Networks” /1/ when installing and operating the device.

The EU declaration of conformity is available for the responsible authorities according to the above-mentioned EU directive at the following address:

Siemens Aktiengesellschaft Bereich Automatisierungs- und Antriebstechnik Industrielle Kommunikation (A&D PT2) Postfach 4848 D-90327 Nürnberg

Show 5 more labels / short text on this page
Product Name · EMC Directive · Area of Application · Installation Guidelines · Conformity Certificates
Page 27 of the Siemens X005 user manual — Notes on the CE Mark
Seite 27 · Zum Vergrößern klicken
Seite 27

This product is not a machine in the sense of the EU directive on machines. There is therefore no declaration of conformity for the EU directive on machines 89/392/EEC.

If the product is part of the equipment of a machine, it must be included in the procedure for the declaration of conformity by the manufacturer of the machine.

Page 28 of the Siemens X005 user manual — 7.1 References
Seite 28 · Zum Vergrößern klicken
Seite 28

References 7

7.1 References

Sources of Information and Other Documentation

1. SIMATIC NET Industrial Twisted Pair and Fiber Optic Networks, Edition 05/2001 Order numbers: 6GK1970-1BA10-0AA0 German 6GK1970-1BA10-0AA1 English 6GK1970-1BA10-0AA2 French 6GK1970-1BA10-0AA4 Italian
2. You will find further information on the SCALANCE system on the Internet at www.siemens.com/scalance
Page 29 of the Siemens X005 user manual — References
Seite 29 · Zum Vergrößern klicken
Seite 29
Page 29 of the Siemens X005 user manual — References
Page 30 of the Siemens X005 user manual — Dimension Drawing 8
Seite 30 · Zum Vergrößern klicken
Seite 30

Dimension Drawing 8

Siemens X005 — Dimension Drawing 8 diagram (page 30)
Abb. 22 · Dimension Drawing 8
Siemens X005 — Dimension Drawing 8 diagram (page 30)
Abb. 23 · Dimension Drawing 8

Figure 8-1 Drilling template

Page 31 of the Siemens X005 user manual — Dimension Drawing
Seite 31 · Zum Vergrößern klicken
Seite 31
Page 31 of the Siemens X005 user manual — Dimension Drawing
Quellen

Referenzen & Links

In dieser Anleitung genannte Seiten – Hersteller, Support und Downloads.

Frage zu Siemens X005 stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Siemens X005

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Siemens X005 PDF-Anleitung

64 Seiten·1.4 MB·Switch·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…