This manual contains notices which you should observe to ensure your own personal safety as well as to avoid property damage. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring to property damage only have no safety alert symbol. Depending on the danger level ,the notices are displayed in descending order as follows.
indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury.
indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
used with the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury.
used without the safety alert symbol indicates a potentially hazardous situation which, if not avoided, may result in property damage.
used without the safety alert symbol indicates a potential situation which, if not avoided, may result in an undesirable result or state.
When several danger levels apply, the notices of the highest level (lower number) are always displayed. If a notice refers to personal damages with the safety alert symbol, then another notice may be added warning of property damage.
The device/system may only be set up and operated in conjunction with this documentation. Only qualified personnel should be allowed to install and work on the equipment. Only qualified personnel should be allowed to install and work on the equipment. Qualified persons are defined as persons who are authorized to commission, to earth, and to tag circuits, equipment and systems in accordance with established safety practices and standards.
Please note the following:
This device and its components may only be used for the applications described in the catalog or technical description, and only in connection with devices or components from other manufacturers approved or recommended by Siemens. This product can only function correctly and safely if it is transported, stored, set up and installed correctly, and operated and maintained as recommended.
All designations marked with ® are registered trademarks of Siemens AG. Other designations in this documentation might be trademarks which, if used by third parties for their purposes, might infringe upon the rights of the proprietors.
Copyright Siemens AG, 2005. All rights reserved Reproduction, transmission or use of this document or its contents is not permitted without express written authority. Offenders will be liable for damages. All rights, including rights created by patent grant or registration of a utility model or design, are reserved.
Disclaimer of Liability We have checked the contents of this manual for agreement with the hardware and software described. Since deviations cannot be precluded entirely, we cannot guarantee full agreement. However, the data in the manual are reviewed regularly, and any necessary corrections will be included in subsequent editions. Suggestions for improvement are welcomed.
Siemens AG Automation and Drives Group P.O. Box 4848, D-90327 Nuremberg (Germany)
Siemens AG 2005 Technical data subject to change Siemens Aktiengesellschaft A2B00051528A




Purpose of the Commissioning Manual
This commissioning manual supports you when commissioning the unmanaged Industrial Ethernet entry level switch SCALANCE X005.
Validity of this Commissioning Manual
This commissioning manual is valid for the following devices:
The “SIMATIC NET Industrial Ethernet Twisted Pair and Fiber Optic Networks” manual contains additional information on other SIMATIC NET products that you can operate along with the SCALANCE X005 switch in an Industrial Ethernet network.
You can download this network manual from Customer Support on the Internet under entry number 1172207.
This commissioning manual is intended for personnel involved in the commissioning of the SCALANCE X005 switch in a network.
The SCALANCE X005 device meets the requirements for the CE mark. For detailed information, refer to the Chapter “Notes on the CE Mark”.
Further Documentation · Audience · Standards and Approvals



This chapter provides you with an overview of the functions of the unmanaged Industrial Ethernet entry level switch SCALANCE X005.
The SCALANCE X005 switch enables the cost-effective installation of small Industrial Ethernet bus or star structures with switching functionality. The devices are designed for installation in a switching cubicle.
It is not possible to use the SCALANCE X005 switch in a redundant ring since it does not support the redundancy function.
The requirements of EN61000-4-5, surge test on power supply lines, are met only when a Blitzductor VT AD 24V type no. 918 402 is used.
The specified approvals apply only when the corresponding mark is printed on the product.
What Is Possible?



Switching technology allows extensive networks to be set up with numerous nodes and simplifies network expansion.
Which network topologies can be implemented?
With the SCALANCE X005 device, bus and star topologies can be implemented.


Figure 3-1 Bus topology with SCALANCE X005
Bus Topology

Network Topologies 3.1 Network Topologies

Figure 3-2 Star topology with SCALANCE X005
Star Topology

What ships with the SCALANCE X005 ?
Do not use any parts that show evidence of damage!
If the SCALANCE X005 device is operated in ambient temperatures between 60°C - 65°C, the temperature of the device housing may be higher than 65°C.
The subject unit must be located in a Restricted Access Location where access can only be gained by SERVICE PERSONNEL or by USERS who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken when operated in an ambient temperature of 60°C - 65°C.
Unpacking, Checking

Product Characteristics 4.3 SCALANCE X005 Product Characteristics
SCALANCE X005 features five RJ-45 jacks for the connection of DTEs or other network segments.

Figure 4-1 SCALANCE X005
Possible Attachments

Product Characteristics 4.4 SCALANCE X005 TP Ports

Figure 4-2 RJ-45 connector pinout
Pin 8 NC Pin 7 NC Pin 6 TD- Pin 5 NC Pin 4 NC Pin 3 TD+ Pin 2 RD- Pin 1 RD+
On SCALANCE X005, the twisted pair ports are implemented as RJ-45 jacks with MDI-X assignment (Medium Dependent Interface–Autocrossover) of a network component.
TP cords or TP-XP cords with a maximum length of 10 m can be connected at the RJ-45 TP port.
Depending on the cable type, a maximum total cable length of 100 m is permitted between two devices with the IE FC cables and IE FC RJ-45 plugs 180.
Autonegotiation means the automatic detection of the functionality of the port at the opposite end. Using autonegotiation, repeaters or DTEs can detect the functionality available at the

Product Characteristics 4.4 SCALANCE X005 TP Ports
port of a partner device allowing automatic configuration of different types of device. With autonegotiation, two components connected to a link segment can exchange parameters and set themselves to match the supported communication functionality.
Devices not supporting autonegotiation must be set to 100 Mbps/ half duplex or 10 Mbps half duplex.
If the receive line pair is incorrectly connected (RD+ and RD- switched), the polarity is automatically adapted.
The SCALANCE X005 is a plug and play device which does not require settings for commissioning.
MDI /MDIX Autocrossover Function
The advantage of the MDI /MDIX autocrossover function is that straight-through cables can be used throughout and crossover Ethernet cables are unnecessary. This prevents malfunctions resulting from mismatching send and receive wires. This makes installation much easier for the user.
The SCALANCE X005 device supports the MDI / MDIX autocrossover function.
Fixed configured ports of partner stations must be set to 100 Mbps/ half duplex or 10 Mbps half duplex.
Please note that a direct connection of two ports or an unintentional connection via several switches causes an unpermissible loop which may cause network overload and network failures.
Auto polarity exchange

Product Characteristics 4.5 SCALANCE X005 Power Supply
The power supply is connected using a 2-pin plug-in terminal block. The power supply is connected over a high resistance with the enclosure to allow an ungrounded setup. The power supply is non-floating.


Figure 4-3 Power supply Figure 4-4 Connector pinout
Pin number Pinout Pin 1 M (Mass) Pin 2 L+ (+18 - 32V DC)
The SCALANCE X005 device is designed for operation with safety extra-low voltage. This means that only safety extra-low voltages (SELV) complying with IEC950/EN60950/ VDE0805 can be connected to the power supply terminals.
The power supply unit to supply SCALANCE X005 must comply with NEC Class 2 (voltage range 18 - 32 V, current requirement 350 mA).
Never connect SCALANCE X005 to AC voltage. Never connect SCALANCE X005 to DC voltage higher than 32 V DC.
Power indicator (green LED)
The status of the power supply is indicated by a green LED:
Lit green Power supply is connected.
Not lit Power supply is not connected or
Power Supply · Status Meaning

Product Characteristics 4.7 SCALANCE X005 Technical Specifications
Port status indicator (green/yellow LEDs)
The status of the ports is indicated by five LEDs:
Port 1 to 5 LED lit green TP link exists, no data reception
Port 1 to 5 LED lit yellow TP link exists, data received at TP port
Port 1 to 5 LED flashes yellow Test phase during power on
Technical Specifications of SCALANCE X005
Attachment of DTEs or network components over twisted pair
5xRJ-45 sockets with MDI-X pinning 10/100 Mbps (half/ full duplex)
Connector for power supply 1 x 2-pin plug-in terminal block
Power supply Power supply DC 18 .. 32 V safety extra-low voltage (SELV)
Power loss at DC 24 V (typ.) 2 W
Current consumption at rated voltage (typ.) 80 mA
Overvoltage protection at input PTC resetable fuse (0.5 A / 60 V)
Connection over Industrial Ethernet FC TP cables
Industrial Ethernet FC TP standard cable with IE FC RJ-45 plug 180 or over Industrial Ethernet FC outlet RJ-45 with 0 - 90 m Industrial Ethernet FC TP standard cable + 10 m TP cord Industrial Ethernet FC TP marine/trailing cable with IE FC RJ-45 plug 180 or 0 - 75 m Industrial Ethernet FC TP marine/trailing cable + 10 m TP cord
Aging time 375 seconds

Product Characteristics 4.7 SCALANCE X005 Technical Specifications

Operating altitude 2000 m at max 46 °C ambient temperature 3000 m at max. 40 °C ambient temperature
RF interference level EN 61000-6-2 Class A (replaces EN 50081-2 Class A) EN 61000-6-2 Class B with split toroidal core on the lines Manufacturer: Würth Elektronik - type: 742 711 31
Dimensions (W x H x D) in mm 40 x 125 x 124
Installation options DIN rail S7-300 standard rail Wall mounting
“Industrial Ethernet TP and Fiber Optic Networks” manual
IE FC RJ-45 plug 180 pack of 1 6GK1 901-1BB10-2AA0
IE FC RJ-45 plug 180 pack of 10 6GK1 901-1BB10-2AB0
IE FC RJ-45 plug 180 pack of 50 6GK1 901-1BB10-2AE0

Product Characteristics 4.7 SCALANCE X005 Technical Specifications
The number of connected SCALANCE X Industrial Ethernet switches influences the frame propagation time.
When a frame passes through SCALANCE X005, it is delayed by the store and forward function of the switch: - With a 64 byte frame length by approx. 10 µs (at 100 Mbps) - With a 1500 byte frame length by approx. 130 µs (at 100 Mbps) This means that the more SCALANCE X005 devices are passed through, the higher the frame propagation time will be.

SCALANCE X005 can be installed in various ways:
When installing and operating the device, keep to the installation instructions and safety-related notices as described here and in the SIMATIC NET Industrial Ethernet Twisted Pair and Fiber Optic Networks /2/ manual.
Protect the device against exposure to direct sunlight by suitable shadowing. This avoids an undesired temperature rise of the device and prevents premature ageing of device and cabling.
Types of installation

Installation and Maintenance 5.2 Installation on a DIN Rail
Install the SCALANCE X005 on a 35 mm DIN rail complying with DIN EN 50022.



Figure 5-1 SCALANCE X005 installation on a DIN rail (35 mm)
To remove SCALANCE X005 from the rail:
Installation · Uninstalling

Installation and Maintenance 5.3 Installation on a Standard Rail



Figure 5-2 SCALANCE X005 removing from a DIN rail (35 mm)
Installation on a SIMATIC S7-300 Standard Rail
Uninstalling

Installation and Maintenance 5.4 Wall Mounting

Figure 5-3 SCALANCE X005 installation on a SIMATIC S7-300 standard rail
The wall mounting must be capable of supporting at least four times the weight of the device.
Wall Mounting

Installation and Maintenance 5.5 Grounding
Installation on a DIN Rail
The device is grounded over the DIN rail.
The device is grounded over its rear panel and the neck collar screw.
The device is grounded by the securing screw in the unpainted hole.
Please note that SCALANCE X005 must be grounded over one securing screw with minimum resistance.
If the device is mounted on a non-conducting surface, it is required to install a grounding cable. The grounding cable is not included in the delivery. Connect the unpainted surface of the device to the next grounding point via the grounding cable.
S7 Standard Rail · Wall Mounting

Installation and Maintenance 5.6 Assembling the IE FC Standard Cable
Assemble the IE FC RJ-45 plug 180 and the IE FC standard cable as follows
For information on the assembly, please refer to the instructions that ship with the IE FC RJ-45 plug 180.
The robust connectors of the nodes are designed for industry and are PROFINET-compliant. Due to the locking mechanism on the casing, they provide additional strain and torsion relief.




Figure 5-4 IE FC RJ-45 plug 180

Installation and Maintenance 5.6 Assembling the IE FC Standard Cable
Plugging the IE FC RJ-45 Plug 180

Figure 5-5 Plugging the IE FC RJ-45 plug 180
Due to the closing shape and the latching with the PROFINET-compliant connector IE FC RJ-45 plug 180, the sleeve at the TP port of SCALANCE X005 ensures a robust, industry- standard node connection which provides additional strain and torsion relief of the twisted pair port.

Installation and Maintenance 5.7 Maintenance
Unplugging the IE FC RJ-45 Plug 180

Figure 5-6 Unlatching the RJ-45 plug
If, for lack of space, a manual unlatching is not possible, you can also unlatch the plug with a 2.5 mm screwdriver. Subsequently you can unplug the IE FC RJ-45 plug 180 from the twisted pair port.
If a fault develops, please send the device to your SIEMENS service center for repair. Repairs on-site are not possible.
Maintenance

89/336/EEC “Electromagnetic Compatibility”
The product is designed for use in an industrial environment:
Area of Application Requirements
Noise emission Noise immunity
The product meets the requirements if you keep to the installation instructions and safety- related notices as described here and in the manual “SIMATIC NET Industrial Ethernet Twisted Pair and Fiber Optic Networks” /1/ when installing and operating the device.
The EU declaration of conformity is available for the responsible authorities according to the above-mentioned EU directive at the following address:
Siemens Aktiengesellschaft Bereich Automatisierungs- und Antriebstechnik Industrielle Kommunikation (A&D PT2) Postfach 4848 D-90327 Nürnberg

This product is not a machine in the sense of the EU directive on machines. There is therefore no declaration of conformity for the EU directive on machines 89/392/EEC.
If the product is part of the equipment of a machine, it must be included in the procedure for the declaration of conformity by the manufacturer of the machine.