AXIS 216FD AXIS 216FD-V
AXIS 216MFD AXIS 216MFD-V Fixed Dome Network Camera
Installation Guide



Installation Guide
This installation guide provides instructions for installing the AXIS 216FD, AXIS 216FD-V, AXIS 216MFD and AXIS 216MFD-V Fixed Network Dome Camera on your network. For all other aspects of using the product, please see the User’s Manual, available on the CD included in this package, or from www.axis.com/techsup Installation steps

16mm cable conduit (not supplied) fitted to AXIS 216FD-V/216MFD-V



Power connector (see page 14)
Product ID & Serial number (S/N). The serial number may be required during the installation.
Dimensions HxWxD = 94 x 144 x 132mm (3.7" x 5.7" x 5.2") Weight AXIS 216FD/AXIS 216MFD = 425g (0.94 lb) (power supply not included) Weight AXIS 216FD-V/216MFD-V = 580g (1.28 lb) (power supply not included)
Cover plates · Control button

!
The AXIS 216FD/216FD-V/216MFD/216MFD-V can be mounted with the cables routed through the wall/ceiling, or from above or below. There are cover plates for the openings on both sides of the dome cover. The AXIS 216FD-V/216MFD-V can also be fitted with a metal conduit for protecting the cabling when connected via the side openings. See the illustrations on page 4.
To mount the AXIS 216FD/216FD-V/216MFD/216MFD-V on a hard ceiling, check that the ceiling material is sturdy enough to hold the weight of the camera.
The camera can also be secured using a plate or board that better carries the weight of the camera, and which is more suitable for securing the screws.
216MFD/216MFD-V
The AXIS 216FD/AXIS 216MFD can also be mounted using the AXIS 216FD/AXIS 216MFD Drop Ceiling Mount, which allows the camera to be mounted more discreetly. Please see www.axis.com for all available mounting accessories.


Most networks today have a DHCP server that automatically assigns IP addresses to connected devices. If your network does not have a DHCP server the AXIS 216FD/216FD-V/ 216MFD/216MFD-V will use 192.168.0.90 as the default IP address.
If you would like to assign a static IP address the recommended method in Windows is either AXIS IP Utility or AXIS Camera Management. Depending on the number of cameras you wish to install, use the method that best suits your purpose.
Both of these free applications are available on the Axis Network Video Product CD supplied with this product, or they can be downloaded from www.axis.com/techsup

AXIS IP Utility automatically discovers and displays Axis devices on your network. The application can also be used to manually assign a static IP address.

Automatic discovery 1. Check that the AXIS 216FD/216FD-V/216MFD/216MFD-V is connected to the network and that power has been applied. 2. Start AXIS IP Utility. 3. When the camera appears in the window, double-click it to open its home page. 4. See page 10 for instructions on how to assign the password.
Assign the IP address manually (optional) 1. Acquire an unused IP address on the same network segment as your computer. 2. Select the AXIS 216FD/AXIS 216MFD in the list.
AXIS 216FD and AXIS 216FD-V will display in AXIS Camera Management as AXIS 216FD. AXIS 216MFD and AXIS 216MFD-V will display in AXIS Camera Management as AXIS 216MFD.

AXIS Camera Management can automatically discover multiple Axis devices, show connection status, manage firmware upgrades and set IP addresses.

Automatic discovery 1. Check that the camera is connected to the network and that power has been applied. 2. Start AXIS Camera Management. When the AXIS 216FD/AXIS 216MFD appears in the window, double-click it to open the camera’s home page. 3. See page 10 for instructions on how to set the password.
Assign an IP address in a single device 1. Select AXIS 216FD/AXIS 216MFD in AXIS Camera Man-

agement and click the Assign IP button.
Assign IP addresses in multiple devices AXIS Camera Management speeds up the process of assigning IP addresses to multiple devices, by suggesting IP addresses from a specified range.

els can be selected) and click the Assign IP button. 2. Select Assign the following IP address range and enter the range of IP addresses, the subnet mask and default router the devices will use. 3. Click the OK button. Note:
AXIS 216FD and AXIS 216FD-V will display in AXIS Camera Management as AXIS 216FD. AXIS 216MFD and AXIS 216MFD-V will display in AXIS Camera Management as AXIS 216MFD.

When accessing the AXIS 216FD/216FD-V/ 216MFD/216MFD-V for the first time, the ‘Configure Root Password’ dialog will be displayed.

Setup - Provides all the tools for configuring the camera to requirements.

Help - Displays online help on all aspects of using the camera.

Open the Live View page in the web interface and make the following adjustments to the camera:
2. Turn the lens to the desired position. 3. Once satisfied, gently tighten the locking screw and tilt adjustment screws to secure the camera’s position. 4. Turn the image balance ring to set the horizontal position. 5. Open the Focus Adjustment page in the Web interface under Basic Configuration > Focus and follow the on- screen instructions. Use the image window to adjust the focus and zoom. 6. To set the focus and zoom, loosen the zoom and focus pullers anti-clockwise and rotate the rings.
Focus puller Zoom puller
Due to the dome’s refraction, the image might appear slightly out of focus once the dome has been placed. To compensate, focus on an object slightly closer than the inteded area.
The image can also be fine-tuned for low lighting conditions. Go to Setup > Video & Image > Advanced and see the online help for more information.

Once installed, your AXIS 216FD/216FD-V/216MFD/216MFD-V is accessible on your local network (LAN). To access the camera from the Internet, network routers must be configured to allow incoming traffic, which is usually done on a specific port. Please refer to the documentation for your router for further instructions. For more information on this and other topics, visit the Axis Support Web at www.axis.com/techsup

The table below shows the other methods available for setting or discovering the IP address. All methods are enabled by default, and all can be disabled.
Use in operating system
Windows (ME or XP)
When enabled on your computer, the camera is automatically detected and added to “My Network Places.”
Bonjour MAC OSX (10.4 or later)
Applicable to browsers with support for Bonjour. Navigate to the Bonjour bookmark in your browser (e.g. Safari) and click on the link to access the camera’s web pages.
AXIS Dynamic DNS Service
All A free service from Axis that allows you to quickly and simply install your camera. Requires an Internet connection with no HTTP proxy. See www.axiscam.net for more information.
ARP/Ping All See below. The command must be issued within 2 minutes of connecting power to the camera.
All To view the admin pages for the network DHCP server, see the server’s own documentation.
View DHCP server admin pages
Windows syntax Windows example
arp -s ping -l 408 -t
arp -s 192.168.0.125 00-40-8c-18-10-00 ping -l 408 -t 192.168.0.125
UNIX/Linux/Mac syntax UNIX/Linux/Mac example
arp -s temp ping -s 408
arp -s 192.168.0.125 00:40:8c:18:10:00 temp ping -s 408 192.168.0.125
UPnP™

Network connector - RJ-45 Ethernet connector. Supports Power over Ethernet. Using shielded cables is recommended.
Power connector - Mini DC connector. 5.1V DC, max 3.8W. See product label for ± connection.
Audio in - 3.5mm input for a mono microphone, or a line-in mono signal (left channel is used from a stereo signal).
Audio out - Audio output (line level) that can be connected to a public address (PA) system or an active speaker with a built-in amplifier. A pair of headphones can also be attached. A stereo connector must be used for the audio out.
I/O terminal connector - Used in applications for e.g. motion detection, event triggering, time lapse recording and alarm notifications. It provides the interface to:
Function Pin number Notes Specifications
3.3V DC Power
2 Can be used to power auxiliary equipment.
Max load = 50mA
Digital Input 3 Connect to GND to activate, or leave floating (or unconnected) to deactivate.
Must not be exposed to voltages greater than 10V DC
4 Uses an open-collector NPN transistor with the emitter connected to the GND pin. If used with an external relay, a diode must be con- nected in parallel with the load, for protection against voltage transients.
Max load = 50mA Max voltage = 24V DC (to the transistor)
Transistor Output



Network Green Steady for connection to a 100 Mbit/s network. Flashes for network activity.
Amber Steady for connection to 10 Mbit/s network. Flashes for network activity.
Status Green Steady green for normal operation. Note: The Status LED can be configured to be unlit during normal operation, or to flash only when the camera is accessed. To configure, go to Setup > System Options > LED settings. See the online help files for more information.
Amber Steady during startup, during reset to factory default or when restoring settings.

This will reset all parameters, including the IP address, to the Factory Default settings:
1. Disconnect power from the camera. 2. Press and hold the Control button and reconnect power. 3. Keep the Control button pressed until the Power indicator flashes amber (this may take up to 15 seconds). 4. Release the Control button. When the Power indicator displays green (which can take up to 1 minute) the process is complete and the camera has been reset. 5. Re-assign the IP address, using one of the methods described in this document. It is also possible to reset parameters to the original factory default settings via the web interface. For more information, please see the online help or the user’s manual.
The user’s manual is available from the Axis Web site at www.axis.com or from the Axis Network Video Product CD supplied with this product.
In dieser Anleitung genannte Seiten – Hersteller, Support und Downloads.
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.
Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.