Isolated Multi-Dr op ™ Converter Operator’ s Manual Manual No. SG-6048-01 LOGO Isolated Multi-Drop™ Po r t 1 Tx Rx Po r t 4 Tx Rx Po r t 3 Tx Rx Po r t 2 Tx Rx RS485 RS485 RS485 RS485.
The use of unauthorized parts in the repair of the equipment o r tam- pering by unqualified pe rsonnel will r esult in danger ous conditions which may cause sever e personal injury or equipment damage. Follow all safety instructions contained her ein.
Contents Siemens Energy & Automation, Inc. 1 Introduction ........ ................... ....... 1 1.1 Product S ummary......... ...... ....... ...... ....... ... 1 1.2 How to Use This Manual .... ............. .......... 1 2 Setting Up the Converter .
1 Intr oduction Siemens Energy & Automation, Inc. 1 1 Introduction 1.1 Pr odu ct Summary The Siemens Isolated Multi-Dr op TM conver t er is an electr onic device that lets you connect your DO S-based PC to the Siemens SEAbus TM communications network for ACCESS TM devices o n your power distribution system.
2 Setting Up the Converter 2 Siemens Energy & Automation, Inc. 2 Setting Up th e Conver ter 2.1 Ove rvie w Before connecting the converter to y our system, understand the connectors, LEDs and switches.
2 Setting Up the Converter Siemens Energy & Automation, Inc. 3 . Figure 2.4 Rear Panel The BAUD thumbwheel switch selects the data rate for communications. Set the data rate to be consistent with the data rate for your system’ s S EAbus communications network.
3 Installing th e Converter 4 Siemens Energy & Automation, Inc. 3 Installing the Converter 3.1 Getting Ready This section explains how to install the Isolated Multi-Drop converter for your operation. Y ou can install t he converter either dir ectly to a PC or r emotely within switchgear using short-haul or dial-up modems.
3 Installing the Converter Siemens Energy & Automation, Inc. 5 3.3 Connecting Directly to a PC T o connect the Isolated Multi-Dr op converter dir ectly to a PC, you need an RS-2 32 serial cable of not more than 50 feet in length. Make sure the cable is a DCE-DTE cable, not a null modem cable .
3 Installing th e Converter 6 Siemens Energy & Automation, Inc. 3.4 Connecting wit h Short-Haul Modems If the distance between your PC and Isolated Multi-Dr op converter is gr e ater than 50 feet but less than 3.5 miles, you can connect them using short-haul modems and regular telephone cable.
3 Installing the Converter Siemens Energy & Automation, Inc. 7 3.5 Connecting wit h Dial-Up Modems If the distance between your PC and Isolated Multi-Dr op converter is gr eater than 3.
4 T esting ACCESS Devices 8 Siemens Energy & Automation, Inc. 4 T esting ACC ESS Dev ices Y ou can use the Isolated Multi-Dr op converter’ s 15 VDC power output to pr ovide DC power for testing Static T rip III trip units or SAMMS devices.
4 T esting ACCESS Devices Siemens Energy & Automation, Inc. 9 4.3 T esting Static T rip III on Desktop If you are testing a Static T rip III trip unit on a desktop, follow these steps to connect the trip unit to t h e converter for 15 VDC power , while re f erring to Figur e 4.
4 T esting ACCESS Devices 10 Siemens Energy & Automation, Inc. Figure 4.4 Connecting SAMMS Device for T esting T wo-wire cable RS-485 cable rear panel front panel 15VDC OUT + - RS485 + _ + _ RS485.
5 T r ou bleshootin g Siemens Energy & Automation, Inc. 11 5 T roubleshooting If you exper ience communications errors and suspect the Isolated Multi-Dr op converter i s at fault, perform the actions listed below . Before performing these tests: 1.
5 T r ou blesh ooting 12 Siemens Energy & Automation, Inc. NOTE S:.
Appendic es Siemens Energy & Automation, Inc. 13 Appendix A: Block Diag ram The illustratio n below is a block diagram showi ng how the Isolated Multi-Dr op converter operates. The diagram identifies the internal components that make up the converter .
Appendices 14 Siemens Energy & Automation, Inc.
Appendic es Siemens Energy & Automation, Inc. 15 Appendix B: M ounting Dimensions The illustration below shows the mounting dimensions for the Iso lated Multi-Drop conv erter . Use these dimensions to muont the converter to a switchgear panel or to some other location.
Appendices 16 Siemens Energy & Automation, Inc.
Siemens Ener gy & Automat i on, Inc. Switchgear and Motor C ontrol Business P .O. Box 2950 3 Ralei gh, NC 2762 6-0503 Manual No. SG- 6048-01 (Replaces -0 0) 1M 0595FP Printed in U.
Ein wichtiger Punkt beim Kauf des Geräts Siemens ISOLATED MULTI-DROP SG-6048-01 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Siemens ISOLATED MULTI-DROP SG-6048-01 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Siemens ISOLATED MULTI-DROP SG-6048-01 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Siemens ISOLATED MULTI-DROP SG-6048-01 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Siemens ISOLATED MULTI-DROP SG-6048-01 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Siemens ISOLATED MULTI-DROP SG-6048-01 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Siemens ISOLATED MULTI-DROP SG-6048-01 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Siemens ISOLATED MULTI-DROP SG-6048-01. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Siemens ISOLATED MULTI-DROP SG-6048-01 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.