1 Overviewp.91.1 Important Notesp.91.2 Maintenance Notesp.101.3 Product Identificationp.101.4 About the Manualp.101.5 Conventions for this Documentp.101.6 The OpenStage Familyp.111.6.1 OpenStage 60/80p.111.6.2 OpenStage 40p.121.6.3 OpenStage 20p.141.7 Administration Interfacesp.141.7.1 Web-based Management (WBM)p.141.7.2 DLS Service (Deployment Service)p.151.7.3 Local Phone Menup.152 Startupp.172.1 Prerequisitesp.172.2 Assembling and Installing the Phonep.182.2.1 Shipmentp.182.2.2 Connectors at the bottom sidep.182.2.3 Assemblyp.202.2.4 Connecting the Phonep.212.3 Quick Startp.232.3.1 Access the Web Interface (WBM)p.232.3.2 Set the Terminal Numberp.242.3.3 Basic Network Configurationp.262.3.4 Date and Time / SNTPp.262.3.5 SIP Server Addressp.262.3.6 Extended Network Configurationp.272.3.7 Vendor specific: VLAN Discovery and DLS addressp.272.3.7.1 Using a Vendor Classp.282.3.7.2 Using Option #43 "Vendor Specific"p.362.3.8 Registering at the HiPath 8000p.413 Administrationp.433.1 Access via Local Phonep.433.2 LAN Settingsp.473.2.1 LAN Port Settingsp.473.2.2 VLANp.493.2.2.1 Automatic VLAN discovery (DHCP)p.503.2.2.2 Manual configuration of a VLAN IDp.513.3 IP Network Parametersp.523.3.1 Quality of Service (QoS)p.523.3.1.1 Layer 2 / 802.1pp.523.3.1.2 Layer 3 / Diffservp.533.3.2 Use DHCPp.553.3.3 IP Address - Manual Configurationp.573.3.4 Default Route/Gatewayp.583.3.5 Specific IP Routingp.593.3.6 DNSp.603.3.6.1 DNS Domain Namep.603.3.6.2 DNS Serversp.613.3.7 Configuration & Update Service (DLS)p.623.3.8 SNMPp.633.4 Speech Encryption (V1R4.x upwards)p.663.5 System Settingsp.673.5.1 Terminal and User Identityp.673.5.1.1 Terminal Identityp.673.5.1.2 Display Identityp.683.5.2 Emergency and Voice Mailp.693.5.3 Pixel Saver (OpenStage 40/60/80)p.713.5.4 Date and Timep.723.5.4.1 SNTP is available, but no automatic configuration by DHCP serverp.723.5.4.2 No SNTP server availablep.743.5.5 SIP Addresses and Portsp.753.5.5.1 SIP Addressesp.753.5.5.2 SIP Portsp.763.5.6 SIP Registrationp.773.5.7 SIP Connection and Communicationp.793.5.7.1 Response Timerp.793.5.7.2 Connectivity Checkp.793.5.7.3 Outbound Proxyp.803.5.7.4 SIP Transport Protocolp.813.5.8 SIP Session Timerp.823.5.9 SIP Survivabilityp.843.6 Features - Configurationp.873.6.1 Allow Refusep.873.6.2 Group Pickupp.893.6.2.1 Feature Codep.893.6.2.2 Pickup alert (V1R3.x upwards)p.903.6.3 Call Transferp.923.6.3.1 Transfer on Ringp.923.6.3.2 Transfer on Hangupp.923.6.4 Callback URIsp.943.6.5 Message Waiting Addressp.953.6.6 System Based Conferencep.963.6.7 Server Based Features (V1R3.x upwards)p.973.6.8 uaCSTA Interfacep.983.6.9 Local Menu Timeoutp.1003.7 Multiline Appearance/Keysetp.1023.7.1 Line key configurationp.1023.7.2 Configure Keyset Operationp.1063.7.3 Direct Station Select (DSS)p.1103.7.3.1 General DSS Settingsp.1103.7.3.2 Settings for a DSS keyp.1113.7.4 Key Modulesp.1133.8 Dialingp.1143.8.1 Canonical Dialing Configurationp.1143.8.2 Canonical Dial Lookupp.1183.9 Mobilityp.1203.10 Transferring Phone Software, Application and Media Filesp.1213.10.1 FTP/HTTPS Serverp.1213.10.2 Common FTP/HTTPS Settingsp.1213.10.3 Phone Softwarep.1233.10.3.1 FTP/HTTPS Access Datap.1233.10.3.2 Download/Update Phone Softwarep.1253.10.4 Music on Holdp.1263.10.4.1 FTP/HTTPS Access Datap.1263.10.4.2 Download Music on Holdp.1293.10.5 Picture Clipsp.1303.10.5.1 FTP/HTTPS Access Datap.1303.10.5.2 Download Picture Clipp.1323.10.6 LDAP Templatep.1333.10.6.1 FTP/HTTPS Access Datap.1333.10.6.2 Download LDAP Templatep.1353.10.7 Logop.1363.10.7.1 FTP/HTTPS Access Datap.1363.10.7.2 Download Logop.1383.10.8 Screensaverp.1393.10.8.1 FTP/HTTPS Access Datap.1393.10.8.2 Download Screensaverp.1413.10.9 Ringer Filep.1423.10.9.1 FTP/HTTPS Access Datap.1423.10.9.2 Download Ringer Filep.1453.11 Corporate Phonebook: Directory Settingsp.1463.11.1 LDAPp.1463.12 Speechp.1483.12.1 RTP Base Portp.1483.12.2 Codec Preferencesp.1493.12.3 Audio Settingsp.1513.13 Applicationsp.1523.13.1 XML Applications (OpenStage 60/80 with V1R3.x upwards)p.1523.13.1.1 Basic Setup/Configurationp.1523.13.1.2 HTTP Proxyp.1553.13.1.3 Modify an Existing Applicationp.1573.13.1.4 Remove an Existing Applicationp.1583.14 Passwordp.1603.15 Troubleshooting: Lost Passwordp.1613.16 Factory Resetp.1623.17 Diagnosticsp.1633.17.1 Display General Phone Informationp.1633.17.2 LAN Monitoringp.1643.17.3 IP Testsp.1653.17.4 Process and Memory Informationp.1663.17.5 Fault Trace Configurationp.1673.17.6 Easy Trace Profilesp.1733.17.6.1 Bluetooth Handsfreep.1733.17.6.2 Bluetooth Headsetp.1733.17.6.3 Call Connectionp.1743.17.6.4 Call Logp.1743.17.6.5 LDAP Phonebookp.1753.17.6.6 DAS Connectionp.1753.17.6.7 DLS Data Errorsp.1753.17.6.8 802.1xp.1763.17.6.9 Help Applicationp.1763.17.6.10 Sidecarp.1763.17.6.11 Key Inputp.1773.17.6.12 LAN Connectivityp.1773.17.6.13 Local Phonebookp.1773.17.6.14 Messagingp.1783.17.6.15 Mobilityp.1783.17.6.16 Phone administrationp.1783.17.6.17 Server based applicationsp.1793.17.6.18 Speechp.1793.17.6.19 Tonep.1793.17.6.20 USB Backup/Restorep.1793.17.6.21 Voice Diallingp.1803.17.6.22 Web Based Managementp.1803.17.6.23 No Tracing for All Servicesp.1813.17.7 QoS Reportsp.1823.17.7.1 Conditions and Thresholds for Report Generationp.1823.17.7.2 View Reportp.1853.17.8 Core dumpp.1893.17.9 Remote Tracing - Syslog (V1R4.x upwards)p.1893.17.10 Test Interfacep.1903.18 Bluetoothp.1914 Examples and HowTosp.1934.1 Canonical Dialingp.1934.1.1 Canonical Dialing Settingsp.1934.1.2 Canonical Dial Lookupp.1944.1.2.1 Conversion examplesp.1954.2 How to Create Logo Files for OpenStage Phonesp.1974.2.1 For OpenStage 40p.1974.2.2 For OpenStage 60/80p.1984.3 How to Set Up the Corporate Phonebook (LDAP)p.2014.3.1 Prerequisites:p.2014.3.2 Create an LDAP Templatep.2024.3.3 Load the LDAP Template into the Phonep.2054.3.4 Configure LDAP Accessp.2064.3.5 Testp.2065 Technical Referencep.2095.1 Menusp.2095.1.1 Web Interface Menup.2095.1.1.1 Menu Structurep.2095.1.1.2 Web Pagesp.2125.1.2 Local Phone Menup.239
Page 1 of the Siemens 8000 user manual — Communication for the open minded
Seite 1 · Zum Vergrößern klicken
Seite 1

Documentation

HiPath 8000 OpenStage 20, OpenStage 40, OpenStage 60, OpenStage 80

A31003-O1010-M100-10-76A9

Siemens 8000 — A31003-O1010-M100-10-76A9 diagram (page 1)
Abb. 1

Communication for the open minded

Siemens Enterprise Communications www.siemens.com/open

Administration Manual

Page 2 of the Siemens 8000 user manual
Seite 2 · Zum Vergrößern klicken
Seite 2
Page 2 of the Siemens 8000 user manual
Page 3 of the Siemens 8000 user manual — Content 0
Seite 3 · Zum Vergrößern klicken
Seite 3

bkTOC.fm

Nur für den internen Gebrauch Content

Content 0

1 Overview 1-1 1.1 Important Notes 1-1 1.2 Maintenance Notes 1-2 1.3 Product Identification 1-2 1.4 About the Manual 1-2 1.5 Conventions for this Document 1-2 1.6 The OpenStage Family 1-3 1.6.1 OpenStage 60/80 1-3 1.6.2 OpenStage 40 1-4 1.6.3 OpenStage 20 1-6 1.7 Administration Interfaces 1-6 1.7.1 Web-based Management (WBM) 1-6 1.7.2 DLS Service (Deployment Service) 1-7 1.7.3 Local Phone Menu 1-7

2 Startup 2-1 2.1 Prerequisites 2-1 2.2 Assembling and Installing the Phone 2-2 2.2.1 Shipment 2-2 2.2.2 Connectors at the bottom side 2-2 2.2.3 Assembly 2-4 2.2.4 Connecting the Phone 2-5 2.3 Quick Start 2-7 2.3.1 Access the Web Interface (WBM) 2-7 2.3.2 Set the Terminal Number 2-8 2.3.3 Basic Network Configuration 2-10 2.3.4 Date and Time / SNTP 2-10 2.3.5 SIP Server Address 2-10 2.3.6 Extended Network Configuration 2-11 2.3.7 Vendor specific: VLAN Discovery and DLS address 2-11 2.3.7.1 Using a Vendor Class 2-12 2.3.7.2 Using Option #43 "Vendor Specific" 2-20 2.3.8 Registering at the HiPath 8000 2-25

3 Administration 3-1 3.1 Access via Local Phone 3-1 3.2 LAN Settings 3-5 3.2.1 LAN Port Settings 3-5 3.2.2 VLAN 3-7 3.2.2.1 Automatic VLAN discovery (DHCP) 3-8 3.2.2.2 Manual configuration of a VLAN ID 3-9

Page 4 of the Siemens 8000 user manual
Seite 4 · Zum Vergrößern klicken
Seite 4

bkTOC.fm

Content Nur für den internen Gebrauch

3.3 IP Network Parameters 3-10 3.3.1 Quality of Service (QoS) 3-10 3.3.1.1 Layer 2 / 802.1p 3-10 3.3.1.2 Layer 3 / Diffserv 3-11 3.3.2 Use DHCP 3-13 3.3.3 IP Address - Manual Configuration 3-15 3.3.4 Default Route/Gateway 3-16 3.3.5 Specific IP Routing 3-17 3.3.6 DNS 3-18 3.3.6.1 DNS Domain Name 3-18 3.3.6.2 DNS Servers 3-19 3.3.7 Configuration & Update Service (DLS) 3-20 3.3.8 SNMP 3-21 3.4 Speech Encryption (V1R4.x upwards) 3-24 3.5 System Settings 3-25 3.5.1 Terminal and User Identity 3-25 3.5.1.1 Terminal Identity 3-25 3.5.1.2 Display Identity 3-26 3.5.2 Emergency and Voice Mail 3-27 3.5.3 Pixel Saver (OpenStage 40/60/80) 3-29 3.5.4 Date and Time 3-30 3.5.4.1 SNTP is available, but no automatic configuration by DHCP server 3-30 3.5.4.2 No SNTP server available 3-32 3.5.5 SIP Addresses and Ports 3-33 3.5.5.1 SIP Addresses 3-33 3.5.5.2 SIP Ports 3-34 3.5.6 SIP Registration 3-35 3.5.7 SIP Connection and Communication 3-37 3.5.7.1 Response Timer 3-37 3.5.7.2 Connectivity Check 3-37 3.5.7.3 Outbound Proxy 3-38 3.5.7.4 SIP Transport Protocol 3-39 3.5.8 SIP Session Timer 3-40 3.5.9 SIP Survivability 3-42 3.6 Features - Configuration 3-45 3.6.1 Allow Refuse 3-45 3.6.2 Group Pickup 3-47 3.6.2.1 Feature Code 3-47 3.6.2.2 Pickup alert (V1R3.x upwards) 3-48 3.6.3 Call Transfer 3-50 3.6.3.1 Transfer on Ring 3-50 3.6.3.2 Transfer on Hangup 3-50 3.6.4 Callback URIs 3-52 3.6.5 Message Waiting Address 3-53

Page 5 of the Siemens 8000 user manual
Seite 5 · Zum Vergrößern klicken
Seite 5

bkTOC.fm

Nur für den internen Gebrauch Content

3.6.6 System Based Conference 3-54 3.6.7 Server Based Features (V1R3.x upwards) 3-55 3.6.8 uaCSTA Interface 3-56 3.6.9 Local Menu Timeout 3-58 3.7 Multiline Appearance/Keyset 3-60 3.7.1 Line key configuration 3-60 3.7.2 Configure Keyset Operation 3-64 3.7.3 Direct Station Select (DSS) 3-68 3.7.3.1 General DSS Settings 3-68 3.7.3.2 Settings for a DSS key 3-69 3.7.4 Key Modules 3-71 3.8 Dialing 3-72 3.8.1 Canonical Dialing Configuration 3-72 3.8.2 Canonical Dial Lookup 3-76 3.9 Mobility 3-78 3.10 Transferring Phone Software, Application and Media Files 3-79 3.10.1 FTP/HTTPS Server 3-79 3.10.2 Common FTP/HTTPS Settings 3-79 3.10.3 Phone Software 3-81 3.10.3.1 FTP/HTTPS Access Data 3-81 3.10.3.2 Download/Update Phone Software 3-83 3.10.4 Music on Hold 3-84 3.10.4.1 FTP/HTTPS Access Data 3-84 3.10.4.2 Download Music on Hold 3-87 3.10.5 Picture Clips 3-88 3.10.5.1 FTP/HTTPS Access Data 3-88 3.10.5.2 Download Picture Clip 3-90 3.10.6 LDAP Template 3-91 3.10.6.1 FTP/HTTPS Access Data 3-91 3.10.6.2 Download LDAP Template 3-93 3.10.7 Logo 3-94 3.10.7.1 FTP/HTTPS Access Data 3-94 3.10.7.2 Download Logo 3-96 3.10.8 Screensaver 3-97 3.10.8.1 FTP/HTTPS Access Data 3-97 3.10.8.2 Download Screensaver 3-99 3.10.9 Ringer File 3-100 3.10.9.1 FTP/HTTPS Access Data 3-100 3.10.9.2 Download Ringer File 3-103 3.11 Corporate Phonebook: Directory Settings 3-104 3.11.1 LDAP 3-104 3.12 Speech 3-106 3.12.1 RTP Base Port 3-106 3.12.2 Codec Preferences 3-107

Page 6 of the Siemens 8000 user manual
Seite 6 · Zum Vergrößern klicken
Seite 6

bkTOC.fm

Content Nur für den internen Gebrauch

3.12.3 Audio Settings 3-109 3.13 Applications 3-110 3.13.1 XML Applications (OpenStage 60/80 with V1R3.x upwards) 3-110 3.13.1.1 Basic Setup/Configuration 3-110 3.13.1.2 HTTP Proxy 3-113 3.13.1.3 Modify an Existing Application 3-115 3.13.1.4 Remove an Existing Application 3-116 3.14 Password 3-118 3.15 Troubleshooting: Lost Password 3-119 3.16 Factory Reset 3-120 3.17 Diagnostics 3-121 3.17.1 Display General Phone Information 3-121 3.17.2 LAN Monitoring 3-122 3.17.3 IP Tests 3-123 3.17.4 Process and Memory Information 3-124 3.17.5 Fault Trace Configuration 3-125 3.17.6 Easy Trace Profiles 3-131 3.17.6.1 Bluetooth Handsfree 3-131 3.17.6.2 Bluetooth Headset 3-131 3.17.6.3 Call Connection 3-132 3.17.6.4 Call Log 3-132 3.17.6.5 LDAP Phonebook 3-133 3.17.6.6 DAS Connection 3-133 3.17.6.7 DLS Data Errors 3-133 3.17.6.8 802.1x 3-134 3.17.6.9 Help Application 3-134 3.17.6.10 Sidecar 3-134 3.17.6.11 Key Input 3-135 3.17.6.12 LAN Connectivity 3-135 3.17.6.13 Local Phonebook 3-135 3.17.6.14 Messaging 3-136 3.17.6.15 Mobility 3-136 3.17.6.16 Phone administration 3-136 3.17.6.17 Server based applications 3-137 3.17.6.18 Speech 3-137 3.17.6.19 Tone 3-137 3.17.6.20 USB Backup/Restore 3-137 3.17.6.21 Voice Dialling 3-138 3.17.6.22 Web Based Management 3-138 3.17.6.23 No Tracing for All Services 3-139 3.17.7 QoS Reports 3-140 3.17.7.1 Conditions and Thresholds for Report Generation 3-140 3.17.7.2 View Report 3-143 3.17.8 Core dump 3-147

Page 7 of the Siemens 8000 user manual
Seite 7 · Zum Vergrößern klicken
Seite 7

bkTOC.fm

Nur für den internen Gebrauch Content

3.17.9 Remote Tracing - Syslog (V1R4.x upwards) 3-147 3.17.10 Test Interface 3-148 3.18 Bluetooth 3-149

4 Examples and HowTos 4-1 4.1 Canonical Dialing 4-1 4.1.1 Canonical Dialing Settings 4-1 4.1.2 Canonical Dial Lookup 4-2 4.1.2.1 Conversion examples 4-3 4.2 How to Create Logo Files for OpenStage Phones 4-5 4.2.1 For OpenStage 40 4-5 4.2.2 For OpenStage 60/80 4-6 4.3 How to Set Up the Corporate Phonebook (LDAP) 4-9 4.3.1 Prerequisites: 4-9 4.3.2 Create an LDAP Template 4-10 4.3.3 Load the LDAP Template into the Phone 4-13 4.3.4 Configure LDAP Access 4-14 4.3.5 Test 4-14

5 Technical Reference 5-1 5.1 Menus 5-1 5.1.1 Web Interface Menu 5-1 5.1.1.1 Menu Structure 5-1 5.1.1.2 Web Pages 5-4 5.1.2 Local Phone Menu 5-31

Glossary 6-1

Index 7-1

Page 8 of the Siemens 8000 user manual
Seite 8 · Zum Vergrößern klicken
Seite 8

bkTOC.fm

Content Nur für den internen Gebrauch

Page 9 of the Siemens 8000 user manual — Q
Seite 9 · Zum Vergrößern klicken
Seite 9

uebersicht.fm

1 Overview

1.1 Important Notes

Do not operate the equipment in environments where there is a danger of explosions.

Q

For safety reasons the phone should only be operating using the supplied plug in power unit. Use only original Siemens accessories!

Using other accessories may be dangerous, and will invalidate the warranty, extended manufacturer’s liability and the CE mark. Never open the telephone or add-on equipment. If you encounter any problems, con tact System Support. Installation requirement for USA, Canada, Norway, Finland and Sweden: Connection to networks which use outside cables is prohibited. Only in-house networks are permit ted.

  • 7 For USA and Canada only: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential installation. This equipment generates, uses, and can radi ate radio frequency energy and, if not installed and used in accordance with the in structions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help. This product is a UL Listed Accessory, I.T.E., in U.S.A. and Canada. This equipment also complies with the Part 68 of the FCC Rules and the Industrie Canada CS-03.

Overview Important Notes

Page 10 of the Siemens 8000 user manual — 1.5 Conventions for this Document
Seite 10 · Zum Vergrößern klicken
Seite 10

uebersicht.fm

1.2 Maintenance Notes

Do not operate the telephone in environments where there is a danger of ex plosions.

Use only original Siemens accessories. Using other accessories may be dan gerous, and will invalidate the warranty and the CE mark.

Never open the telephone or a key module. If you encounter any problems, con tact System Support.

1.3 Product Identification

1.4 About the Manual

The instructions within this manual will help you in administering and maintaining the Open Stage phone. The instructions contain important information for safe and proper operation of the phones. Follow them carefully to avoid improper operation and get the most out of your multi-function telephone in a network environment.

This guide is intended for service providers and network administrators who administer VoIP services using the OpenStage phone and who have a fundamental understanding of SIP. The tasks described in this guide are not intended for end users. Many of these tasks affect the abil ity of a phone to function on the network and require an understanding of IP networking and telephony concepts.

These instructions are laid out in a user-oriented manner, which means that you are led through the functions of the OpenStage phone step by step, wherever expedient. For the users, a sep arate manual is provided.

You can find further information on the official Siemens Enterprise Communications website (http://www.enterprise-communications.siemens.com) and on the Siemens Enterprise Wiki (ht tp://wiki.siemens-enterprise.com).

1.5 Conventions for this Document

The terms for parameters and functions used in this document are derived from the web inter face (WBM). In some cases, the the phone’s local menu uses shorter, less specific terms and abbreviations. In a few cases the terminologies differ in wording. If so, the local menu term is added with a preceding "/".

Overview · Maintenance Notes

Page 11 of the Siemens 8000 user manual — 1.6 The OpenStage Family
Seite 11 · Zum Vergrößern klicken
Seite 11

uebersicht.fm

Overview The OpenStage Family

1.6 The OpenStage Family

1.6.1 OpenStage 60/80

Siemens 8000 — 1.6 The OpenStage Family diagram (page 11)
Abb. 2 · 1.6 The OpenStage Family
Page 12 of the Siemens 8000 user manual — 1.6.2 OpenStage 40
Seite 12 · Zum Vergrößern klicken
Seite 12

uebersicht.fm

1.6.2 OpenStage 40

1The Handset lets you pick up and dial calls in the usual manner. 2The Graphics Display provides intuitive support for telephone operation. 3The user-friendly Application Keys provide easy access to your telephone’s applications. 4With the TouchGuide, the user/administrator can navigate in the various pho ne functions, applications, and configuration menus. 5You can customize your telephone in line with your personal needs by assig ning individual phone numbers and functions to the Program Keys. 6Press the Function Keys to access frequently used telephony functions. 7The Audio Keys let you optimize the audio settings on your telephone. 8With the TouchSlider, the user can adjust the volume, e.g. of ringtones. 9Inbound calls are visually signaled on the Call Display. 10The Keypad is used for entering phone numbers and text.
Siemens 8000 — 1.6.2 OpenStage 40 diagram (page 12)
Abb. 3 · 1.6.2 OpenStage 40
1The Handset lets you pick up and dial calls in the usual manner. 2The Graphics Display provides intuitive support for telephone operation. 3The user-friendly Application Keys provide easy access to your telephone’s applications. 4With the Navigation Key, the user/administrator can navigate in the various phone functions, applications, and configuration menus.

Overview · The OpenStage Family · Tabelle 1-1

Page 13 of the Siemens 8000 user manual — 1.6.2 OpenStage 40
Seite 13 · Zum Vergrößern klicken
Seite 13

uebersicht.fm

Overview The OpenStage Family

5 You can customize your telephone in line with your personal needs by assig ning individual phone numbers and functions to the Program Keys.

6 Press the Function Keys to access frequently used telephony functions.

7 The Audio Keys let you optimize the audio settings on your telephone.

8 Inbound calls are visually signaled on the Call Display.

9 The Keypad is used for entering phone numbers and text.

Page 14 of the Siemens 8000 user manual — >
Seite 14 · Zum Vergrößern klicken
Seite 14

uebersicht.fm

1.6.3 OpenStage 20

Siemens 8000 — 1.6.3 OpenStage 20 diagram (page 14)
Abb. 4 · 1.6.3 OpenStage 20

1 The Handset lets you pick up and dial calls in the usual manner.

2 The Display provides intuitive support for telephone operation.

3 The user-friendly Application Keys provide easy access to your telephone’s applications.

4 Press the Function Keys to access frequently used telephony functions.

5 With the Navigation Key, the user/administrator can navigate in the various phone functions, applications, and configuration menus.

6 The Keypad is used for entering phone numbers and text.

1.7 Administration Interfaces

You can configure the OpenStage phone by using any of the following methods.

1.7.1 Web-based Management (WBM)

This method employs a web browser for communication with the phone via HTTP or HTTPS. It is applicable for remote configuration of individual IP phones in your network. Direct access to the phone is not required.

>

To use this method, the phone must first obtain IP connectivity.

Overview · Administration Interfaces

Page 15 of the Siemens 8000 user manual — >
Seite 15 · Zum Vergrößern klicken
Seite 15

uebersicht.fm

1.7.2 DLS Service (Deployment Service)

The Deployment Service (DLS) is a HiPath Management application for administering phones and soft clients in both HiPath and non-HiPath networks. It has a Java-supported, web-based user interface, which runs on an internet browser. For further information, please refer to the Deployment Service Administration Guide.

1.7.3 Local Phone Menu

This method provides direct configuration of an the OpenStage phone. Direct access to the phone is required.

>

As long as the IP connection is not properly configured, you have to use this method to set up the phone.

Overview Administration Interfaces

Page 16 of the Siemens 8000 user manual — 1.7.2 DLS Service (Deployment Service)
Seite 16 · Zum Vergrößern klicken
Seite 16

uebersicht.fm

Overview · Administration Interfaces

Page 17 of the Siemens 8000 user manual — 2.1 Prerequisites
Seite 17 · Zum Vergrößern klicken
Seite 17

inbetriebnahme.fm

2 Startup

2.1 Prerequisites

The OpenStage phone acts as an endpoint client on an IP telephony network, and has the fol lowing network requirements: • An Ethernet connection to a network with SIP clients and servers.

7 Only use switches in the LAN, to which the OpenStage phone is connected. An operation at hubs can cause serious malfunctions in the hub and in the whole network.

  • HiPath 8000 server.
  • An FTP Server for file transfer, e. g. firmware, configuration data, application software.
  • A DHCP (Dynamic Host Configuration Protocol) server (recommended).
  • DLS (Deployment Service) for advanced configuration and software deployment (recommended).

Startup Prerequisites

Page 18 of the Siemens 8000 user manual — PC
Seite 18 · Zum Vergrößern klicken
Seite 18

inbetriebnahme.fm

Assembling and Installing the Phone

2.2 Assembling and Installing the Phone

2.2.1 Shipment

  • Phone
  • Handset
  • Handset cable
  • Subpackage:
  • Document "Information and Important Operating Procedures"
  • Emergency number sticker
  • Emergency Number Sticker

2.2.2 Connectors at the bottom side

Siemens 8000 — 2.2.2 Connectors at the bottom side diagram (page 18)
Abb. 5 · 2.2.2 Connectors at the bottom side

PC

Show 9 more labels / short text on this page
Startup · OpenStage 60 · Keyboard · Power supply · USB Extension · Switch · Headset · Key Module · Handset
Page 19 of the Siemens 8000 user manual — PC
Seite 19 · Zum Vergrößern klicken
Seite 19

inbetriebnahme.fm

Startup Assembling and Installing the Phone

OpenStage 40 (similar to OpenStage 20, except 1)

Siemens 8000 — 2.2 Assembling and Installing the Phone diagram (page 19)
Abb. 6 · 2.2 Assembling and Installing the Phone

[1] OpenStage 40 only

PC

Show 5 more labels / short text on this page
Power supply · Switch · Headset[1] · Key Module[1] · Handset
Page 20 of the Siemens 8000 user manual — 2.2.3 Assembly
Seite 20 · Zum Vergrößern klicken
Seite 20

inbetriebnahme.fm

Assembling and Installing the Phone

2.2.3 Assembly

1. Handset

Insert the plug on the long end of the handset cable into the jack on the base of the tele phone and press the cable into the groove provided for it. Next, insert the plug on the short end of the handset cable into the jack on the handset.

2. Emergency Number Sticker Write your telephone number and those for the fire and police departments on the included label and attach it to the telephone housing underneath the handset (see arrow).
Siemens 8000 — 2.2.3 Assembly diagram (page 20)
Abb. 7 · 2.2.3 Assembly

Startup

Page 21 of the Siemens 8000 user manual — 2.2.4 Connecting the Phone
Seite 21 · Zum Vergrößern klicken
Seite 21

inbetriebnahme.fm

Startup Assembling and Installing the Phone

2.2.4 Connecting the Phone

1. Plug the LAN cable into the connector at the bottom of the telephone and connect the cable to the LAN resp. switch. If PoE (Power over Ethernet) is to be used, the PSE (Power Sourcing Equipment) must meet the IEEE 802.3af specification. For details about the required power supply, see the following table:

OpenStage 20 Power Class 1

OpenStage 20 G Power Class 2

OpenStage 40 + 2nd Key Module Power Class 3

OpenStage 40 G1 Power Class 3

OpenStage 40 G + 2nd Key Module External power unit required

OpenStage 60/80 + 2nd Key Module Power Class 3

OpenStage 60/80 G2 Power Class 3

OpenStage 60/80 G + 2nd Key Module External power unit required

1 Includes 1 Key Module.

2 Includes 1 Key Module + USB-Extension with Acoustic Unit.

2. Only if Power over Ethernet (PoE) is NOT supported:

7 Use only the plug-in power supply unit fitting the OpenStage phone: EU: C39280-Z4-C510 UK: C39280-Z4-C512 USA: C39280-Z4-C511

Plug the power supply unit into the mains. Connect the plug-in power supply unit to the jack at the bottom of the phone.

Show 6 more labels / short text on this page
Model Power Consumption/Supply · OpenStage 401 · Power Class 2 · OpenStage 60/802 · Power Class 3 · Tabelle 2-1
Page 22 of the Siemens 8000 user manual — 2.2.4 Connecting the Phone
Seite 22 · Zum Vergrößern klicken
Seite 22

inbetriebnahme.fm

Assembling and Installing the Phone

3. If applicable, connect the following optional jacks:
  • LAN connection to PC
  • Headset (accessory)
  • Connection to add-on device (accessory)
  • Connection to external keyboard (accessory)
  • USB master for connection to a USB device (e. g. accessory USB Acoustic Adapter)

7 To prevent damage on the OpenStage phone, connect an USB stick using the adapter cable C39195-Z7704-A5.

7 Do not connect a USB hub to the phone’s USB port, as this may lead to stability problems.

Startup

Page 23 of the Siemens 8000 user manual — 2.3.1 Access the Web Interface (WBM)
Seite 23 · Zum Vergrößern klicken
Seite 23

inbetriebnahme.fm

2.3 Quick Start

This section describes a typical case: the setup of an OpenStage endpoint in an environment using a DHCP server and the web interface. For different scenarios, cross-references to the corresponding section of the administration chapter are given.

>

Alternatively, the DLS (Deployment Service) administration tool can be used. Its Plug & Play functionality allows to provide the phone with configuration data by as signing an existing data profile to the phone’s MAC address or E.164 number. For further information, see the Deployment Service Administration Manual.

>

Any settings made by a DHCP server are not configurable by other configuration tools.

2.3.1 Access the Web Interface (WBM)

1. Open your web browser (MS Internet Explorer or Firefox) and enter the transfer protocol, IP address and port number of your phone. If HTTP is used, port 8085 must be added, for example http://192.168.1.15:8085 For HTTPS, the phone uses the standard port 443. After entering the URL, the browser might display a certificate notification. The start page of the web interface appears. In the upper right corner, the phone number, the phone’s IP address, as well as the DNS name assigned to the phone are displayed. The left corner contains the user menu tree.

Siemens 8000 — 2.3.1 Access the Web Interface (WBM) diagram (page 23)
Abb. 8 · 2.3.1 Access the Web Interface (WBM)

Startup Quick Start

Page 24 of the Siemens 8000 user manual — 2.3.2 Set the Terminal Number
Seite 24 · Zum Vergrößern klicken
Seite 24

inbetriebnahme.fm

2. Click on the tab "Administrator Pages". In the dialog box, enter the admin password:
Siemens 8000 — 2.3.2 Set the Terminal Number diagram (page 24)
Abb. 9 · 2.3.2 Set the Terminal Number
3. The administration main page opens. The left column contains the menu tree. If you click on an item which is printed in normal style, the corresponding dialog opens in the center of the page. If you click on an item printed in bold letters, a sub-menu opens in the right column.

2.3.2 Set the Terminal Number

If the user and administrator menus are needed in the course of setup, the terminal number, which by default is identical with the phone number, must be configured first. The terminal num ber input form is presented to the user/administrator right after booting, unless the Plug&Play facility of the DLS is used. For further information about this setting, please refer to Section 3.5.1.1, “Terminal Identity”. With the WBM, the teminal number is configured as follows:

Siemens 8000 — 2.3.2 Set the Terminal Number diagram (page 24)
Abb. 10 · 2.3.2 Set the Terminal Number

Startup · Quick Start

Page 25 of the Siemens 8000 user manual — 2.3.2 Set the Terminal Number
Seite 25 · Zum Vergrößern klicken
Seite 25

inbetriebnahme.fm

4. In the left column, select System > System Identity to open the "System Identity" dialog. Enter the terminal number, i. e. the SIP name / phone number.
Siemens 8000 — 2.3.2 Set the Terminal Number diagram (page 25)
Abb. 11 · 2.3.2 Set the Terminal Number

Startup Quick Start

Page 26 of the Siemens 8000 user manual — 2.3.5 SIP Server Address
Seite 26 · Zum Vergrößern klicken
Seite 26

inbetriebnahme.fm

2.3.3 Basic Network Configuration

  • For basic functionality, DHCP must provide the following parameters:
  • IP Address : IP Address for the phone.
  • Subnet Mask (option #1) : Subnet mask of the phone.
  • Default Route (option #3 "Router") : IP Address of the default gateway which is used for connections beyond the subnet.
  • DNS IP Addresses (option #6 "Domain Server") : IP Addresses of the primary and sec ondary DNS servers.

If no DHCP server is present, see Section 3.3.3, “IP Address - Manual Configuration” for IP ad dress and subnet mask, and Section 3.3.4, “Default Route/Gateway” for default route.

2.3.4 Date and Time / SNTP

An SNTP (Simple Network Time Protocol) server provides the current date and time for network clients. The IP address of an SNTP server can be given by DHCP.

In order to provide the correct time, it is required to give the timezone offset, i.e. the shift in hours to be added to the UTC time provided by the SNTP server.

  • The following DHCP options are required:
  • SNTP IP Address (option #42 "NTP Servers") : IP Address of the SNTP server to be used by the phone.
  • Timezone offset (option #2 "Time Offset") : Offset in hours in relationship to the UTC time provided by the SNTP server.

For manual configuration of date and time see Section 3.5.4, “Date and Time”.

2.3.5 SIP Server Address

The IP Address or hostname of a SIP server can be provided by DHCP.

The option’s name and code are as follows: • option #120 "SIP Servers DHCP Option"

For manual configuration of the SIP server address see Section 3.5.5.1, “SIP Addresses”.

Startup · Quick Start

Page 27 of the Siemens 8000 user manual — 2.3.7 Vendor specific: VLAN Discovery and DLS address
Seite 27 · Zum Vergrößern klicken
Seite 27

inbetriebnahme.fm

2.3.6 Extended Network Configuration

To have constant access to other subnets, you can enter a total of two more network destina tions. For each further domain/subnet you wish to use, first the IP address for the destination, and then that of the router must be given. The option’s name and code are as follows: • option #33 "Static Routing Table"

For manual configuration of specific/static routing see Section 3.3.5, “Specific IP Routing”.

Also the DNS domain wherein the phone is located can be specified by DHCP. The option’s name and code are as follows: • option #15 "Domain Name"

For manual configuration of the DNS domain name see Section 3.3.6.1, “DNS Domain Name”.

2.3.7 Vendor specific: VLAN Discovery and DLS address

If the phone is to be located in a VLAN (Virtual LAN), a VLAN ID must be assigned. In case the VLAN shall be provided by DHCP, VLAN Discovery must be set to "DHCP" (see Section 3.2.2.1, “Automatic VLAN discovery (DHCP)”).

If a DLS (Deployment Service) server is in use, its IP address must be provided. It is recom mended to configure the DLS server address by DCHP, as this method enables full Plug & Play: having received the DLS address from DHCP, the phone will contact the DLS during startup. Provided that the DLS is configured appropriately, it will send all necessary configuration data to the phone. Additionally, this method is relevant to security, as it ensures the authenticity of the DLS server.

For manual configuration of the DLS server address see Section 3.3.7, “Configuration & Update Service (DLS)”.

For the configuration of vendor-specific settings by DHCP, there are two alternative methods: 1) the use of a vendor class, or 2) the use of DHCP option 43.

Startup Quick Start

Page 28 of the Siemens 8000 user manual — >
Seite 28 · Zum Vergrößern klicken
Seite 28

inbetriebnahme.fm

2.3.7.1 Using a Vendor Class

It is recommended to define a vendor class on the DHCP server, thus enabling server and phone to exchange vendor-specific data exclusively. The data is disclosed from other clients.

In the following, the configuration of vendor classes is explained both for a Windows DHCP Server and for Unix/Linux.

Configuration of the Windows DHCP Server

For DHCP servers on a pre-SP2 Windows 2003 Server:

>

Windows 2003 Server contains a bug that prevents you from using the DHCP console to create an option with the ID 1 for a user-defined vendor class. In stead, this entry must be created with the netsh tool in the command line (DOS shell).

You can use the following command to set the required option (without error message), so that it will appear in the DHCP console afterwards:

netsh dhcp server add optiondef 1 "Optipoint element 001" STRING 0 vendor=OptiIpPhone comment="Tag 001 for Optipoint"

The value "Siemens" for optiPoint Element 1 can then be re-assigned using the DHCP console.

This error was corrected in Windows 2003 Server SP2.

1. In the Windows Start menu, select Start > Programs > Administrative Tools > DHCP .
2. In the DHCP console menu, right-click the DHCP server in question and select Define Vendor Classes... in the context menu.
Siemens 8000 — > diagram (page 28)
Abb. 12
3. A dialog window opens with a list of the classes that are already available.

Startup · Quick Start

Page 29 of the Siemens 8000 user manual — 2.3.7.1 Using a Vendor Class
Seite 29 · Zum Vergrößern klicken
Seite 29

inbetriebnahme.fm

Siemens 8000 — 2.3.7.1 Using a Vendor Class diagram (page 29)
Abb. 13 · 2.3.7.1 Using a Vendor Class
4. Press Add... to define a new vendor class.
5. Enter "OptiIpPhone" as Display name and give a description of this class. Provide the class name proper by setting the cursor underneath ASCII and typing "OptiIpPhone". The binary value is displayed simultaneously.
Siemens 8000 — 2.3.7.1 Using a Vendor Class diagram (page 29)
Abb. 14 · 2.3.7.1 Using a Vendor Class

Click OK to apply the changes. The new vendor class now appears in the list:

Siemens 8000 — 2.3.7.1 Using a Vendor Class diagram (page 29)
Abb. 15 · 2.3.7.1 Using a Vendor Class
6. Exit the window with Close .

Startup Quick Start

Page 30 of the Siemens 8000 user manual — 2.3.7.1 Using a Vendor Class
Seite 30 · Zum Vergrößern klicken
Seite 30

inbetriebnahme.fm

7. In the DHCP console menu, right-click the DHCP server in question and select Set Pre defined Options from the context menu.
Siemens 8000 — 2.3.7.1 Using a Vendor Class diagram (page 30)
Abb. 16 · 2.3.7.1 Using a Vendor Class
8. In the dialog, select the previously defined OptiIpPhone class and click on Add... to add a new option. (If the workaround for a pre-SP2 Windows 2003 Server has been applied, the first option will be there already.)
Siemens 8000 — 2.3.7.1 Using a Vendor Class diagram (page 30)
Abb. 17 · 2.3.7.1 Using a Vendor Class

Startup · Quick Start

Page 31 of the Siemens 8000 user manual — 2.3.7.1 Using a Vendor Class
Seite 31 · Zum Vergrößern klicken
Seite 31

inbetriebnahme.fm

9. In the following dialog, specify the option type as follows. (If the workaround for a pre-SP2 Windows 2003 Server has been applied, the option type dialog will be skipped for the first option.)
  • Name: Free text, e. g. "OptiIpPhone element 01".
  • Data type: "String".
  • Code: "1" .
  • Description: Free text, e. g. "tag 1 for OptiIpPhone class".
Siemens 8000 — 2.3.7.1 Using a Vendor Class diagram (page 31)
Abb. 18 · 2.3.7.1 Using a Vendor Class

Click OK to return to the previous window.

10. The newly created option is displayed now. Enter "Siemens" in the Value field.
Siemens 8000 — 2.3.7.1 Using a Vendor Class diagram (page 31)
Abb. 19 · 2.3.7.1 Using a Vendor Class

Startup Quick Start

Page 32 of the Siemens 8000 user manual — 2.3.7.1 Using a Vendor Class
Seite 32 · Zum Vergrößern klicken
Seite 32

inbetriebnahme.fm

11. If the VLAN is to be provided by DHCP: Repeat step 7 and 8, and then specify the option type as follows. If you want to proceed to the configuration of the DLS address, continue with step 13.
  • Name: Free text, e. g. "OptiIpPhone element 02"
  • Data type: "Long"
  • Code: "2"
  • Description: Free text, e. g. "tag 2 for OptiIpPhone class".
Siemens 8000 — 2.3.7.1 Using a Vendor Class diagram (page 32)
Abb. 20 · 2.3.7.1 Using a Vendor Class

Click OK to return to the previous window.

12. The newly created option is displayed now. Enter the VLAN ID as a hexadecimal number in the Value field. In the example, the VLAN ID is 10 (Hex: 2A).
Siemens 8000 — 2.3.7.1 Using a Vendor Class diagram (page 32)
Abb. 21 · 2.3.7.1 Using a Vendor Class

If you do not intend to configure the DLS address, click OK and continue with step 15.

Startup · Quick Start

Page 33 of the Siemens 8000 user manual — 2.3.7.1 Using a Vendor Class
Seite 33 · Zum Vergrößern klicken
Seite 33

inbetriebnahme.fm

13. If the DLS address is to be provided by DHCP: Repeat step 7 and 8, and then specify the option type as follows.
  • Name: Free text, e. g. "OptiIpPhone element 03".
  • Data type: "String".
  • Code: "3" .
  • Description: Free text, e. g. "tag 3 for OptiIpPhone class".
Siemens 8000 — 2.3.7.1 Using a Vendor Class diagram (page 33)
Abb. 22 · 2.3.7.1 Using a Vendor Class

Click OK to return to the previous window.

14. The newly created option is displayed now. Enter the DLS address in the Value field, using the following format: :://: In the example, the DLS address is "sdlp://192.168.3.30:18443".
Siemens 8000 — 2.3.7.1 Using a Vendor Class diagram (page 33)
Abb. 23 · 2.3.7.1 Using a Vendor Class

Click OK.

Startup Quick Start

Page 34 of the Siemens 8000 user manual — 2.3.7.1 Using a Vendor Class
Seite 34 · Zum Vergrößern klicken
Seite 34

inbetriebnahme.fm

15. To define a scope, select the DHCP server in question, and then Scope , and right-click Scope Options . Select Configure Options... in the context menu.
Siemens 8000 — 2.3.7.1 Using a Vendor Class diagram (page 34)
Abb. 24 · 2.3.7.1 Using a Vendor Class
16. Select the Advanced tab. Under Vendor class , select the class that you previously de fined ( OptiIpPhone ) and, under User class , select Default User Class .
Siemens 8000 — 2.3.7.1 Using a Vendor Class diagram (page 34)
Abb. 25 · 2.3.7.1 Using a Vendor Class

Activate the check boxes for the options that you want to assign to the scope (in the exam ple, 001, 002, and 003). Click OK.

Startup · Quick Start

Page 35 of the Siemens 8000 user manual — 2.3.7.1 Using a Vendor Class
Seite 35 · Zum Vergrößern klicken
Seite 35

inbetriebnahme.fm

17. The DHCP console now shows the information that will be transmitted to the corresponding workpoints. Information from the Standard vendor is transmitted to all clients, whereas in formation from the OptiIpPhone vendor is transmitted only to the clients (workpoints) in this vendor class.
Siemens 8000 — 2.3.7.1 Using a Vendor Class diagram (page 35)
Abb. 26 · 2.3.7.1 Using a Vendor Class

Startup Quick Start

Page 36 of the Siemens 8000 user manual — 2.3.7.2 Using Option #43 "Vendor Specific"
Seite 36 · Zum Vergrößern klicken
Seite 36

inbetriebnahme.fm

Setup using a DHCP server on Unix/Linux

The following snippet from a DHCP configuration file (usually dhcpd.conf) shows how to set up a configuration using a vendor class and the "vendor-encapsulated-options" option.

class "OptiIpPhone" { option vendor-encapsulated-options # The vendor encapsulated options consist of hexadecimal values for the option number (for instance, 01), the length of the value (for in stance, 07), and the value (for instance, 53:69:65:6D:65:6E:73). The options can be written in separate lines; the last option must be fol lowed by a ’;’ instead of a ’:’. # Tag/Option #1: Vendor "Siemens" #1 7 S i e m e n s 01:07:53:69:65:6D:65:6E:73: # Tag/Option #2: VLAN ID # 2 4 0 0 0 10 02:04:00:00:00:0A; # Tag/Option #3: DLS IP Address (here: sdlp://192.168.3.30:18443) # 3 25 s d l p : / / 1 9 2 . 1 6 8 . 3 . (...etc.) 03:19:73:64:6C:70:3A:2F:2F:31:39:32:2E:31:36:38:2E:33:2E:33:30: 3A:31:38:34:34:33; match if substring (option vendor-class-identifier, 0, 11) = "OptiIpPhone"; }

2.3.7.2 Using Option #43 "Vendor Specific"

  • Alternatively, option #43 can be used for setting up the VLAN ID and DLS address. The follow ing tags are used:
  • Tag 1: Vendor name
  • Tag 2: VLAN ID
  • Tag 3: DLS address

Optionally, the DLS address can be given in an alternative way: • Tag 4: DLS hostname

The Vendor name tag is coded as follows (the first line indicates the ASCII values, the second line contains the hexadecimal values):

Code Length Vendor name

1 7 S i e m e n s

01 07 53 69 65 6D 65 6E 73

Startup · Quick Start · Table 2-2

Page 37 of the Siemens 8000 user manual — 02 04 00 00 00 0A
Seite 37 · Zum Vergrößern klicken
Seite 37

inbetriebnahme.fm

The following example shows a VLAN ID with the decimal value "10". Providing

:

Code Length VLAN ID

2 4 0 0 1 0

02 04 00 00 00 0A

For manual configuration of the VLAN ID see Section 3.2.2.2, “Manual configuration of a VLAN ID”.

The DLS IP address tag consists of the protocol prefix "sdlp://", the IP address of the DLS serv er, and the DLS port number, which is "18443" by default. The following example illustrates the syntax:

Code Length DLS IP address

3 25 s d l p : / / 1 9 2 . 1 6 8 . 3 . 3 0 : 1 8 4 4 3

73 64 6C 70 3A 2F 2F 31 39 32 2E 31 36 38 2E 33 2E 33 30 3A 31 38 34 34 33

Setup using the Windows DHCP Server

1. In the Windows Start menu, select Start > Programs > Administrative Tools > DHCP .
2. Select the DHCP server and the scope. Choose Configure Options in the context menu using the right mouse button.

Startup Quick Start · Table 2-3

Page 38 of the Siemens 8000 user manual — 2.3.7.2 Using Option #43 "Vendor Specific"
Seite 38 · Zum Vergrößern klicken
Seite 38

inbetriebnahme.fm

3. Enter tag 1, that is the vendor tag.
Siemens 8000 — 2.3.7.2 Using Option #43 "Vendor Specific" diagram (page 38)
Abb. 27 · 2.3.7.2 Using Option #43 "Vendor Specific"
4. If the VLAN ID is to be provided by DHCP: Enter the hexadecimal value in Data entry . Pro viding the length is not required here, as the VLAN ID is always 4 Bytes long. In the exam ple, the VLAN ID is 10 (Hex: 2A).

Startup · Quick Start

Page 39 of the Siemens 8000 user manual — >
Seite 39 · Zum Vergrößern klicken
Seite 39

inbetriebnahme.fm

5. If the DLS address is to be provided by DHCP: Enter the DLS address in the Value field, using the following format: :://:

>

For ensuring proper functionality, the port number should not be followed by any character.

In the example, the DLS address is "sdlp://192.168.3.30:18443". Note that the screenshot also shows the VLAN ID described in step 4.

Siemens 8000 — > diagram (page 39)
Abb. 28

Click OK.

Startup Quick Start

Page 40 of the Siemens 8000 user manual — 2.3.7.2 Using Option #43 "Vendor Specific"
Seite 40 · Zum Vergrößern klicken
Seite 40

inbetriebnahme.fm

6. The DHCP console now shows the information that will be transmitted to the corresponding workpoints.
Siemens 8000 — 2.3.7.2 Using Option #43 "Vendor Specific" diagram (page 40)
Abb. 29 · 2.3.7.2 Using Option #43 "Vendor Specific"

Startup · Quick Start

Page 41 of the Siemens 8000 user manual — 2.3.8 Registering at the HiPath 8000
Seite 41 · Zum Vergrößern klicken
Seite 41

inbetriebnahme.fm

2.3.8 Registering at the HiPath 8000

For registration at the HiPath 8000 SIP server, a SIP user ID and passwort must be provided by the phone. The following procedure describes the configuration using the web interface (see Section 2.3.1, “Access the Web Interface (WBM)”; if the web interface is not applicable, please refer to Section 3.5.6, “Authenticated Registration”):

1. In the administration menu, select System > Registration. The "Registration" dialog opens.
Siemens 8000 — 2.3.8 Registering at the HiPath 8000 diagram (page 41)
Abb. 30 · 2.3.8 Registering at the HiPath 8000
2. In the Server type field, enter "HiQ8000".
3. In Realm , enter the SIP realm the targeted user/password combination refers to.
4. In the User ID and Password fields, enter the user name/password combination for the phone.

Startup Quick Start

Page 42 of the Siemens 8000 user manual — 2.3.8 Registering at the HiPath 8000
Seite 42 · Zum Vergrößern klicken
Seite 42

inbetriebnahme.fm

Startup · Quick Start

Page 43 of the Siemens 8000 user manual — 3.1 Access via Local Phone
Seite 43 · Zum Vergrößern klicken
Seite 43

Administration Access via Local Phone

This chapter describes the configuration of every parameter available on the OpenStage phones. For access via the local phone menu, see the following; for access using the web in terface, please refer to Section 2.3.1, “Access the Web Interface (WBM)”.

3.1 Access via Local Phone

>

The data entered in input fields is parsed and controlled by the phone. Thus, data is accepted only if it complies to the value range.

1. Access the Administration Menu OpenStage 60/80: Press the v key to activate the administration menu (the v key toggles between the user’s configuration menu and the administration menu). OpenStage 60/80 V1R3.x upwards: The v key toggles between the Settings menu, the Applications menu, and the applica tions currently running. Press the v key repeatedly until the "Settings" tab is active. (The v key toggles between the Settings menu, the Applications menu, and the applications currently running.) OpenStage 20/40: Press the keys D, l, and i consecutively to select the administration menu.

2. Enter Password When the Admin menu is active, you will be prompted to enter the administrator password. The default admin password is "123456". It is recommended to change the password (see Section 3.14, “Password”) after your first login. For entering passwords with non-numeric characters, please consider the following: By default, password entry is in numeric mode. For changing the mode, press the # key once or repeatedly, depending on the desired character. The # key cycles around the input modes as follows: (Abc) -> (abc) -> (123) -> (ABC) -> back to start.

Page 44 of the Siemens 8000 user manual — 3 Administration
Seite 44 · Zum Vergrößern klicken
Seite 44

Access via Local Phone

3. Navigate within the Administration Menu

Use the TouchGuide to navigate and execute administrative actions in the administration menu. For using the TouchGuide, see the following figure:

Press the m key briefly- scroll up
Press the i key- confirm entries
Siemens 8000 — 3 Administration diagram (page 44)
Abb. 31 · 3 Administration
Press the h key- cancel a function
Press the g key- open a context menu
Press the l key briefly- scroll down

Run your finger around the sensor ring W: - browse lists and menus - set up volume

Use the 5-way Navigator to navigate and execute administrative actions in the administra tion menu.

Press the m key briefly- scroll up Hold down: - scroll to top of list
Press the i key- confirm entries - perform an action
Siemens 8000 — 3 Administration diagram (page 44)
Abb. 32 · 3 Administration
Press the h key- cancel a function - delete character left
Press the g key- open a context menu - down one level

of cursor - up one level

Press the l key briefly- scroll down Hold down: - scroll to end of list

OpenStage 60/80 · OpenStage 40

Page 45 of the Siemens 8000 user manual — 3 Administration
Seite 45 · Zum Vergrößern klicken
Seite 45

Administration Access via Local Phone

Use the 3-way Navigator to navigate and execute administrative actions in the administra tion menu.

Press the m key briefly- scroll up Hold down: - scroll to top of list
Siemens 8000 — 3 Administration diagram (page 45)
Abb. 33 · 3 Administration
Press the i key- confirm entries - perform an action
Press the l key briefly- scroll down Hold down: - scroll to end of list
4. Select a parameter If a parameter is set by choosing a value from a selective list, an arrow symbol appears in the parameter field that has the focus. Press the key to enter the selective list. Use the Sen sor Wheel resp. the m and l key to scroll up and down in the selective list. To select a list entry, press the i key.
5. Enter the parameter value For selecting numbers and characters, you can use special keys. See the following table:

* Switch to punctuation and special characters.

# Toggle between lowercase characters, uppercase characters, and digits in the following order: (Abc) -> (abc) -> (123) -> (ABC) -> back to start.

OpenStage 20 · Key Function · Tabelle 3-1

Page 46 of the Siemens 8000 user manual — 3 Administration
Seite 46 · Zum Vergrößern klicken
Seite 46

Access via Local Phone

If a parameter is set by entering a number or character data, the onscreen keypad is used. Press the i key to enter the editor. Within the editor, solely use the key numbers or the Sensor Wheel for selecting numbers, characters, or groups of characters. The h key de letes one character in the input field, and the g key moves the cursor to the OK field. The following figure describes the elements of the onscreen keypad and their functions:

Letters, digits, punctuation marks or special characters

Copy contents of active field to clipboard

Insert clipboard contents at cursor position

Move cursor left/right Shift to punctuation and special characters

Shift to numeric entry Shift to upper/lower case

Additionally, you can use the following keys on the keypad as shortcuts for the selection of character groups

* Switch to punctuation and special characters.

# Toggle between lowercase characters, uppercase characters, and digits.

With the OpenStage 20/40, use the keypad for entering parameters. With the 3 way/5 way- Navigator, you can enter, delete, copy and paste characters and numbers as well as navi gate within an entry and toggle the input mode.

6. Save and exit When you are done, select Save & exit and press .
Show 5 more labels / short text on this page
OpenStage 60/80 · Element with focus · Command line · Element Function · OpenStage 20/40
Page 47 of the Siemens 8000 user manual — >
Seite 47 · Zum Vergrößern klicken
Seite 47

3.2 LAN Settings

3.2.1 LAN Port Settings

The OpenStage phone provides an integrated switch which connects the LAN, the phone itself and a PC port. By default, the switch will auto negotiate transfer rate (10/100 Mb/s, 1000 Mb/s with OpenStage 20/40/60/80 G) and duplex method (full or half duplex) with whatever equip ment is connected. Optionally, the required transfer rate and duplex mode can be specified manually using the LAN port speed parameter.

>

In the default configuration, the LAN port supports automatic detection of cable con figuration (pass through or crossover cable) and will reconfigure itself as needed to connect to the network. If the phone is set up to manually configure the switch port settings, the cable detection mechanism is disabled. In this case, care must be taken to use the correct cable type.

The PC Ethernet port is controlled by the PC port mode parameter. If set to "Disabled", the PC port is inactive; if set to "Enabled", it is active. If set to "Mirror", the data traffic at the LAN port is mirrored at the PC port. This setting is for diagnostic purposes. If, for instance, a PC running Ethereal/Wireshark is connected to the PC port, all network activities at the phone’s LAN port can be captured.

When PC port autoMDIX is enabled, the switch determines automatically whether a regular MDI connector or a MDI-X (crossover) connector is needed, and configures the connector ac cordingly.

  • LAN port speed / LAN port type : Settings for the ethernet port connected to a LAN switch. Value range: "Automatic," "10 Mbps half duplex", "10 Mbps full duplex", "100 Mbps half du plex", "100 Mbps full duplex", "1 Gbps half duplex" (OpenStage 60/80 G), "1 Gbps full du plex" (OpenStage 60/80 G). Default: "Automatic".
  • PC port speed / PC port type : Settings for the ethernet port connected to a PC. Value range: "Automatic", "10 Mbps half duplex", "10 Mbps full duplex", "100 Mbps half du plex", "100 Mbps full duplex", "1 Gbps half duplex" (OpenStage 60/80 G), "1 Gbps full du plex" (OpenStage 60/80 G). Default: "Automatic".
  • PC port mode / PC port status : Controls the PC port. Value range: "disabled", "enabled", "mirror". Default: "disabled".

LAN Settings · Data required

Page 48 of the Siemens 8000 user manual — 3.2 LAN Settings
Seite 48 · Zum Vergrößern klicken
Seite 48
  • PC port autoMDIX : Switches between MDI and MDI-X automatically. Value range: "On", "Off". Default: "Off".

Network > Port configuration

Siemens 8000 — 3.2 LAN Settings diagram (page 48)
Abb. 34 · 3.2 LAN Settings

Administration via Local Phone

|--- Administration |--- Network |--- Port Configuration |--- LAN port type |--- PC port status |--- PC port type |--- PC port autoMDIX

LAN Settings · Administration via WBM

Page 49 of the Siemens 8000 user manual — >
Seite 49 · Zum Vergrößern klicken
Seite 49

3.2.2 VLAN

VLAN (Virtual Local Area Network) is a technology that allows network administrators to parti tion one physical network into a set of virtual networks (or broadcast domains).

Physically partitioning the LAN into separate VLANs allows a network administrator to build a more robust network infrastructure. A good example is a separation of the data and voice net works into data and voice VLANs. This isolates the two networks and helps shield the endpoints within the voice network from disturbances in the data network and vice versa.

The implementation of a voice network based on VLANs requires the network infra structure (the switch fabric) to support VLANs.

>

In a layer 1 VLAN, the ports of VLAN-aware switch are assigned to a VLAN statically. The switch only forwards traffic to a particular port if that port is a member of the VLAN that the traffic is allocated to. Any device connected to a VLAN-assigned port is automatically a member of this VLAN, without being a VLAN aware device itself. If two or more network clients are con nected to one port, they cannot be assigned to different VLANs. When a network client is mov ing from one switch to another, the switches’ ports have to be updated accordingly by hand.

With a layer 2 VLAN, the assignment of VLANs to network clients is realized by the MAC ad dresses of the network devices. In some environments, the mapping of VLANs and MAC ad dresses can be stored and managed by a central database. Alternatively, the VLAN ID, which defines the VLAN whereof the device is a member, can be assigned directly to the device, e. g. by DHCP. The task of determining the VLAN an Ethernet packet is belonging to is carried out by VLAN tags within each Ethernet frame. As the MAC addresses are (more or less) wired to the devices, mobility does not require any administrator action, as opposed to layer 1 VLAN. It is possible to assign one device, i.e. one MAC address, to different VLANs.

It is important that every switch connected to a PC is VLAN-capable. This is also true for the integrated switch of the OpenStage. The phone must be configured as a VLAN aware endpoint if the phone itself is a member of the voice VLAN, and the PC connected to the phone’s PC port is a member of the data VLAN.

The VLAN ID can be configured automatically by DHCP or manually.

LAN Settings

Page 50 of the Siemens 8000 user manual — 3.2.2.1 Automatic VLAN discovery (DHCP)
Seite 50 · Zum Vergrößern klicken
Seite 50

3.2.2.1 Automatic VLAN discovery (DHCP)

To automatically discover a VLAN ID using DHCP, the phone must be configured as DHCP en abled, and VLAN discovery mode must be set to "DHCP". The DHCP server must be config ured to supply the Vendor Unique Option in the correct Siemens VLAN over DHCP format. If a phone configured for VLAN discovery by DHCP fails to discover its VLAN, it will proceed to con figure itself from the DHCP within the non-tagged LAN. In these circumstances network routing will probably not be correct.

Network > IP configuration

Siemens 8000 — 3.2.2.1 Automatic VLAN discovery (DHCP) diagram (page 50)
Abb. 35 · 3.2.2.1 Automatic VLAN discovery (DHCP)

Administration via Local Phone

|--- Administration |--- Network |--- IP Configuration |--- VLAN discovery

LAN Settings · Administration via WBM

Page 51 of the Siemens 8000 user manual — 3.2.2.2 Manual configuration of a VLAN ID
Seite 51 · Zum Vergrößern klicken
Seite 51

3.2.2.2 Manual configuration of a VLAN ID

To configure layer 2 VLAN and QoS manually, first make shure that QoS layer 2 and 3 are con figured as described in Section 3.3.1, “Quality of Service (QoS)”, and VLAN discovery is set to "Manual" (see Section 3.2.2.1, “Automatic VLAN discovery (DHCP)”). Then, the phone must be provided with a VLAN ID between 1 and 4095. If you mis-configure a phone to an incorrect VLAN, the phone will possibly not connect to the network. In DHCP mode it will behave as though the DHCP server cannot be found, in fixed IP mode no server connections will be pos sible.

Network > IP configuration

Siemens 8000 — 3.2.2.2 Manual configuration of a VLAN ID diagram (page 51)
Abb. 36 · 3.2.2.2 Manual configuration of a VLAN ID

Administration via Local Phone

|--- Administration |--- Network |--- IP Configuration |--- VLAN ID

LAN Settings · Administration via WBM

Page 52 of the Siemens 8000 user manual — 3.3 IP Network Parameters
Seite 52 · Zum Vergrößern klicken
Seite 52

3.3 IP Network Parameters

3.3.1 Quality of Service (QoS)

The QoS technology based on layer 2 and the two QoS technologies Diffserv and TOS/IP Pre cedence based on layer 3 are allowing the VoIP application to request and receive predictable service levels in terms of data throughput capacity (bandwidth), latency variations (jitter), and delay.

3.3.1.1 Layer 2 / 802.1p

QoS on layer 2 is using 3 Bits in the 802.1q/p 4-Byte VLAN tag which has to be added in the Ethernet header.

The CoS (class of service) value can be set from 0 to 7. 7 is describing the highest priority and is reserved for network management. 5 is used for voice (RTP-streams) by default. 3 is used for signaling by default.

Three Bits Used for CoS

PREAM. SFD DA SA TAG 4 Bytes PT DATA FCS

  • Layer 2 : Activates or deactivates QoS on layer 2. Value range: "Yes", "No". Default: "Yes".
  • Layer 2 voice : Sets the CoS (Class of Service) value for voice data (RTP streams). Value range: 0-7. Default: 5.
  • Layer 2 signalling : Sets the CoS (Class of Service) value for signaling. Value range: 0-7. Default: 3.
  • Layer 2 default : Sets the default CoS (Class of Service) value. Value range: 0-7. Default: 0.

IP Network Parameters · (User Priority) · Data required

Page 53 of the Siemens 8000 user manual — 3.3.1.2 Layer 3 / Diffserv
Seite 53 · Zum Vergrößern klicken
Seite 53

Administration IP Network Parameters

Siemens 8000 — 3.3.1.2 Layer 3 / Diffserv diagram (page 53)
Abb. 37 · 3.3.1.2 Layer 3 / Diffserv

Administration via Local Phone

|--- Administration |--- Network |--- QoS |--- Service |--- Layer 2 |--- Layer 2 voice |--- Layer 2 signalling |--- Layer 2 default

3.3.1.2 Layer 3 / Diffserv

Diffserv assigns a class of service to an IP packet by adding an entry in the IP header.

Traffic flows are classified into 3 per-hop behavior groups:

1. Default Any traffic that does not meet the requirements of any of the other defined classes is placed in the default per-hop behaviour group. Typically, the forwarding has best-effort forwarding characteristics. The DSCP (Diffserv Codepoint) value for Default is "0".
2. Expedited Forwarding (EF referred to RFC 3246) Expedited Forwarding is used for voice (RTP streams) by default. It effectively creates a special low-latency path in the network. The DSCP (Diffserv Codepoint) value for EF is "1 0 1 1 1 0".
3. Assured Forwarding (AF referred to RFC 2597) Assured forwarding is used for signaling messages by default (AF31). It is less stringent than EF in a multiple dropping system. The AF values are containing two digits X and Y (AFXY), where X is describing the priority class and Y the drop level. Four classes X are reserved for AFXY: AF1Y (high priority), AF2Y, AF3Y and AF4Y (low priority).

Administration via WBM · Network > QoS

Page 54 of the Siemens 8000 user manual — 3.3.1.2 Layer 3 / Diffserv
Seite 54 · Zum Vergrößern klicken
Seite 54

Three drop levels Y are reserved for AFXY: AFX1 (low drop probability), AFX2 and AFX3 (High drop probability). In the case of low drop level, packets are buffered over an extended period in the case of high drop level, packets are promptly rejected if they cannot be for warded.

  • Layer 3 : Activates or deactivates QoS on layer 3. Value range: "Yes", "No". Default: "Yes".
  • Layer 3 voice : Sets the CoS (Class of Service) value for voice data (RTP streams). Value range: "AF11", "AF12", "AF13", "AF21", "AF22", "AF23", "AF31", "AF32", "AF33", "AF41", "AF42", "AF43", "EF", "CST". Default: "EF".
  • Layer 3 signalling : Sets the CoS (Class of Service) value for signaling. Value range: "AF11", "AF12", "AF13", "AF21", "AF22", "AF23", "AF31", "AF32", "AF33", "AF41", "AF42", "AF43", "EF", "CST"). Default: "AF31".
Siemens 8000 — 3.3.1.2 Layer 3 / Diffserv diagram (page 54)
Abb. 38 · 3.3.1.2 Layer 3 / Diffserv

Administration via Local Phone

|--- Administration |--- Network |--- QoS |--- Service |--- Layer 3 |--- Layer 3 voice |--- Layer 3 signalling

Show 4 more labels / short text on this page
IP Network Parameters · Data required · Administration via WBM · Network > QoS
Page 55 of the Siemens 8000 user manual — >
Seite 55 · Zum Vergrößern klicken
Seite 55

Administration IP Network Parameters

3.3.2 Use DHCP

If this parameter is set to "Yes", the phone will search for a DHCP server on startup and try to obtain IP data and further configuration parameters from that central server.

If no DHCP server is available in the IP network, please deactivate this option. In this case, the IP address, subnet mask and default gateway/route must be defined manually.

>

The change will only have effect if you restart the phone.

The following parameters can be obtained by DHCP:

  • IP Address
  • Subnet Mask
  • Default Route (Routers option 3)
  • IP Routing/Route 1 & 2 (Static Routes option 33)
  • SNTP IP Address (NTP Server option 42)
  • Timezone offset (Time Server Offset option 2)
  • Primary/Secondary IP Addresses (DNS Server option 6)
  • DNS Domain Name (DNS Domain option 15)
  • SIP Addresses / SIP Server & Registrar (SIP Server option 120)
  • Vendor Unique (option 43)

Basic informations · Optional informations

Page 56 of the Siemens 8000 user manual — 3.3.2 Use DHCP
Seite 56 · Zum Vergrößern klicken
Seite 56

Network > IP configuration

Siemens 8000 — 3.3.2 Use DHCP diagram (page 56)
Abb. 39 · 3.3.2 Use DHCP

Administration via Local Phone

|--- Administration |--- Network |--- IP Configuration |--- Use DHCP

IP Network Parameters · Administration via WBM

Page 57 of the Siemens 8000 user manual — 3.3.3 IP Address - Manual Configuration
Seite 57 · Zum Vergrößern klicken
Seite 57

Administration IP Network Parameters

3.3.3 IP Address - Manual Configuration

If not provided by DHCP dynamically, the phone’s IP address and subnet mask must be spec ified manually.

  • IP address : used for addressing the phone.
  • Subnet mask : subnet mask that is needed for the subnet in use.

Network > IP configuration

Siemens 8000 — 3.3.3 IP Address - Manual Configuration diagram (page 57)
Abb. 40 · 3.3.3 IP Address - Manual Configuration

Administration via Local Phone

|--- Administration |--- Network |--- IP Configuration |--- IP address |--- Subnet mask

Data required · Administration via WBM

Page 58 of the Siemens 8000 user manual — >
Seite 58 · Zum Vergrößern klicken
Seite 58

3.3.4 Default Route/Gateway

If not provided by DHCP dynamically (see Section 3.3.2, “Use DHCP”), enter the IP address of the router that links your IP network to other networks. If the value was assigned by DHCP, it can only be read.

The change will only have effect if you restart the phone.

>

Network > IP configuration

Siemens 8000 — > diagram (page 58)
Abb. 41

Administration via Local Phone

|--- Administration |--- Network |--- IP Configuration |--- Route (default)

IP Network Parameters · Administration via WBM

Page 59 of the Siemens 8000 user manual — 3.3.5 Specific IP Routing
Seite 59 · Zum Vergrößern klicken
Seite 59

Administration IP Network Parameters

3.3.5 Specific IP Routing

To have constant access to network subscribers of other domains, you can enter a total of two more network destinations, in addition to the default route/gateway. This is useful if the LAN has more than one router or if the LAN is divided into subnets.

  • Route 1/2 IP address : IP address of the selected route.
  • Route 1/2 gateway : IP address of the gateway for the selected route.
  • Route 1/2 mask : Network mask for the selected route.

Network > IP configuration

Siemens 8000 — 3.3.5 Specific IP Routing diagram (page 59)
Abb. 42 · 3.3.5 Specific IP Routing

Administration via Local Phone

|--- Administration |--- Network |--- IP Configuration |--- Route 1 IP |--- Route 1 gateway |--- Route 1 mask |--- Route 2 IP |--- Route 2 gateway |--- Route 2 mask

Data required · Administration via WBM

Page 60 of the Siemens 8000 user manual — 3.3.6 DNS
Seite 60 · Zum Vergrößern klicken
Seite 60

3.3.6 DNS

The main task of the domain name system (DNS) is to translate domain names to IP address es. For some features and functions of the OpenStage phone, it is necessary to configure the DNS domain the phone belongs to, as well as the nameservers needed for DNS resolving.

3.3.6.1 DNS Domain Name

This is the name of the phone’s local domain.

Network > IP configuration

Siemens 8000 — 3.3.6 DNS diagram (page 60)
Abb. 43

Administration via Local Phone

|--- Administration |--- Network |--- IP Configuration |--- DNS domain

IP Network Parameters · Administration via WBM

Page 61 of the Siemens 8000 user manual — 3.3.6.2 DNS Servers
Seite 61 · Zum Vergrößern klicken
Seite 61

Administration IP Network Parameters

3.3.6.2 DNS Servers

If not provided by DHCP automatically, a primary and a secondary DNS server can be config ured.

  • Primary DNS : IP address of the primary DNS server.
  • Secondary DNS : IP address of the secondary DNS server.

Network > IP configuration

Siemens 8000 — 3.3.6.2 DNS Servers diagram (page 61)
Abb. 44 · 3.3.6.2 DNS Servers

Administration via Local Phone

|--- Administration |--- Network |--- IP Configuration |--- Primary DNS |--- Secondary DNS

Data required · Administration via WBM

Page 62 of the Siemens 8000 user manual — 3.3.7 Configuration & Update Service (DLS)
Seite 62 · Zum Vergrößern klicken
Seite 62

3.3.7 Configuration & Update Service (DLS)

The Deployment Service (DLS) is a HiPath Management application for administering work points in both HiPath and non-HiPath networks. Amongst the most important features are: se curity (e.g. PSS generation and distribution within an SRTP security domain), mobility for opti Point and OpenStage SIP phones, software deployment, plug&play support, as well as error and activity logging.

DLS address, i.e. the IP address or hostname of the DLS server, and DLS port, i.e. the port on which the DLS server is listening, are required to enable proper communication between phone and DLS. The Contact gap parameter controls a security function. It specifies a mini mum time interval that must elapse between HTTP requests; any requests coming within that time will be ignored. The purpose is to prevent DoS (Denial of Service) attacks on the phone. The Security mode determines whether the communication between the phone and the DLS is secure. A secure connection is established by exchanging credentials between the DLS and the phone for mutual authentication. After this, the communication is encrypted, and a different port is used.

  • DLS address : IP address or hostname of the server on which the Deployment Service is running.
  • DLS port : Port on which the DLS Deployment Service is listening. Default: 18443.
  • Contact gap : Minimum time interval in seconds that must elapse between HTTP requests, in order to prevent DoS attacks. Default: 300.
  • Security mode / Security status : Determines whether the communication between the phone and the DLS is secure. Value range: "Default mode", "Secure mode". Default: "Default".

Network > Update Service (DLS)

Siemens 8000 — 3.3.7 Configuration & Update Service (DLS) diagram (page 62)
Abb. 45 · 3.3.7 Configuration & Update Service (DLS)

IP Network Parameters · Data required · Administration via WBM

Page 63 of the Siemens 8000 user manual — 3.3.8 SNMP
Seite 63 · Zum Vergrößern klicken
Seite 63

Administration IP Network Parameters

Administration via Local Phone

|--- Administration |--- Network |--- Update Service (DLS) |--- DLS address |--- DLS port |--- Contact gap |--- Security status

3.3.8 SNMP

The Simple Network Management Protocol is used by network management systems for mon itoring network-attached devices for conditions that warrant administrative attention. An SNMP manager surveys and, if needed, configures several SNMP elements, e.g. VoIP phones.

The OpenStage phone supports SNMP version 1 and 2.

There are currently 4 categories of trap that can be sent by the phones:

  • OpenStage phones support the following types of standard SNMP traps, as defined in RFC 1157:
  • coldStart : sent if the phone does a full restart.
  • warmStart : sent if only the phone software is restarted.
  • linkUp : sent when IP connectivity is restored.

These traps are designed specifically for receipt and interpretation by the QDC collection sys tem. The traps are common to SIP phones, HFA phones, Gateways, etc.

Traps for important high level SIP related problems

Currently, these traps are related to problems in registering with a SIP Server and to a failure in remotely logging off a mobile user. These traps are aimed at a non-expert user (e.g. a stan dard Network Management System) to highlight important telephony related problems.

Traps specific to OpenStage phones

Currently, the following traps are defined:

TraceEventFatal: sent if severe trace events occur; aimed at expert users.

TraceEventError: sent if severe trace events occur; aimed at expert users.

Standard SNMP traps · QoS Related traps

Page 64 of the Siemens 8000 user manual — 3.3.8 SNMP
Seite 64 · Zum Vergrößern klicken
Seite 64
  • Trap sending enabled : Enables or disables the sending of a TRAP message to the SNMP manager. Value range: "Yes", "No". Default: "No".
  • Trap destination : IP address or hostname of the SNMP manager that receives traps.
  • Trap destination port : Port on which the SNMP manager is receiving TRAP messages.
  • Default: 162.
  • Trap community : SNMP community string for the SNMP manager receiving TRAP mes sages. Default: "snmp".
  • Queries allowed : Enables or disables queries from the SNMP manager.
  • Query password : Password for the execution of a query by the SNMP manager.
  • Diagnostic sending enabled : Enables or disables the sending of diagnostic data to the SNMP manager. Value range: "Yes", "No". Default: "No".
  • Diagnostic destination : IP address or hostname of the SNMP manager receiving diag nostic data.
  • Diagnostic destination port : Port on which the SNMP manager is receiving diagnostic data.
  • Diagnostic community : SNMP community string for the SNMP manager receiving diag nostic data.
  • QoS traps to QCU : Enables or disables the sending of TRAP messages to the QCU serv er. Value range: "Yes", "No". Default: "No".
  • QCU address : IP address of the QCU server.
  • QCU port : Port on which the QCU server is listening for messages. Default: 12010.
  • QCU community : QCU community string. Default: "QOSCD".
  • QoS to generic destination / QoS to generic device : Enables or disables the sending of QoS traps to a generic destination. Value range: "Yes", "No". Default: "No".

IP Network Parameters · Data required

Page 65 of the Siemens 8000 user manual — 3.3.8 SNMP
Seite 65 · Zum Vergrößern klicken
Seite 65

Administration IP Network Parameters

Siemens 8000 — 3.3.8 SNMP diagram (page 65)
Abb. 46

Administration via Local Phone

|--- Administration |--- System |--- SNMP |--- Trap sending enabled |--- Trap destination |--- Trap destination port |--- Trap community |--- Diag sending enabled |--- Diag destination |--- Diag destination port |--- Diag community |--- QoS traps to QCU |--- QCU address |--- QCU port |--- QCU community |--- QoS to generic device

Administration via WBM · System > SNMP

Page 66 of the Siemens 8000 user manual — >
Seite 66 · Zum Vergrößern klicken
Seite 66

Speech Encryption (V1R4.x upwards)

3.4 Speech Encryption (V1R4.x upwards)

With software version V1R4.x or higher, secure speech transmission via SRTP is possible.

If Use secure calls is activated, the encryption of outgoing calls is enabled, and the phone is capable of receiving encrypted calls. An icon in the call view tells the user whether a call is se cure or not. If an active call changes from secure to insecure, e. g. after a transfer, a popup win dow and an alert tone will notify the user. For enabling secure calls, a TLS connection to the HiPath 8000 is required.

For secure calls, it is required that both endpoints support SRTP. The secure call in dication tells the user that the other endpoint has acknowledged the secure connec tion.

>

>

In order to use SRTP, the phone must be configured for NTP (for further information please see Section 3.5.4, “Date and Time”). The reason is that the key generation (MIKEY) uses the system time of the particular device as a basis. Thus, encryption will only work correctly if all devices have the same UTC time.

If SIP server certificate validation resp. Backup SIP server certificate validation is activat ed, the phone will validate the server certificate sent by the HiPath 8000 in order to establish a TLS connection. The server certificate is validated against the root certificate from the trusted certificate authority (CA), which must be stored on the phone first. For delivering the root cer tificate, a DLS (Deployment Software) server is required.

Siemens 8000 — > diagram (page 66)
Abb. 47

Administration via Local Phone

|--- Administration |--- System |--- Security |--- Server cerfificate |--- Backup certificate |--- Use secure calls

Administration via WBM · System > Security

Page 67 of the Siemens 8000 user manual — 3.5 System Settings
Seite 67 · Zum Vergrößern klicken
Seite 67

3.5 System Settings

3.5.1 Terminal and User Identity

3.5.1.1 Terminal Identity

Within a SIP environment, both Terminal Number and Terminal Name may serve as a phone number. The values are used in the userinfo part of SIP URIs.

In order to register with a SIP registrar, the phone sends REGISTER messages to the registrar containing the contents of Terminal number

  • Terminal number : Number to be registered at the SIP registrar.
  • Terminal name : Name to be registered at the SIP registrar.

System > System Identity

Siemens 8000 — 3.5 System Settings diagram (page 67)
Abb. 48 · 3.5 System Settings

Administration via Local Phone

|--- Administration |--- System |--- Identity |--- Terminal number |--- Terminal name

Administration System Settings · Data required · Administration via WBM

Page 68 of the Siemens 8000 user manual — 3.5.1.2 Display Identity
Seite 68 · Zum Vergrößern klicken
Seite 68

3.5.1.2 Display Identity

If an individual name oder number is entered as Display identity, and Enable ID is activated, it is displayed in the phone’s status bar instead of the Terminal number or Terminal name.

System > System Identity

Siemens 8000 — 3.5.1.2 Display Identity diagram (page 68)
Abb. 49 · 3.5.1.2 Display Identity

Administration via Local Phone

|--- Administration |--- System |--- Identity |--- Display identity |--- Enable ID

System Settings · Administration via WBM

Page 69 of the Siemens 8000 user manual — 3.5.2 Emergency and Voice Mail
Seite 69 · Zum Vergrößern klicken
Seite 69

3.5.2 Emergency and Voice Mail

It is important to have an Emergency number configured. If the phone is locked, a clickable area for making an emergency call is created.

If a mailbox located at a remote server shall be used, its Voice mail number must be entered.

Administration via WBM (V1R2.x)

System > Features > Configuration

Siemens 8000 — 3.5.2 Emergency and Voice Mail diagram (page 69)
Abb. 50 · 3.5.2 Emergency and Voice Mail

Administration via WBM (V1R3.x upwards)

System > Features > Configuration

Siemens 8000 — 3.5.2 Emergency and Voice Mail diagram (page 69)
Abb. 51 · 3.5.2 Emergency and Voice Mail

Administration System Settings

Page 70 of the Siemens 8000 user manual — 3.5.2 Emergency and Voice Mail
Seite 70 · Zum Vergrößern klicken
Seite 70

Administration via Local Phone

|--- Administration |--- System |--- Features |--- Configuration |--- General |--- Emergency number |--- Voicemail number

System Settings

Page 71 of the Siemens 8000 user manual — 3.5.3 Pixel Saver (OpenStage 40/60/80)
Seite 71 · Zum Vergrößern klicken
Seite 71

3.5.3 Pixel Saver (OpenStage 40/60/80)

After the phone has beeen incative within a specified timespan, the display backlight is switched off. The length of the timespan ranges from 2 hours to 8 hours.

Local functions > Pixel saver

Siemens 8000 — 3.5.3 Pixel Saver (OpenStage 40/60/80) diagram (page 71)
Abb. 52 · 3.5.3 Pixel Saver (OpenStage 40/60/80)

Administration via Local Phone

|--- Administration |--- Local Functions |--- Pixel saver

Administration System Settings · Administration via WBM

Page 72 of the Siemens 8000 user manual — 3.5.4 Date and Time
Seite 72 · Zum Vergrößern klicken
Seite 72

3.5.4 Date and Time

If the DHCP server in your network provides information about the SNTP server access, the correct date and time is automatically shown on the phone. If the DHCP server in your network does not provide an SNTP address, you have to set the SNTP address manually, using the SNTP IP address parameter. If no SNTP server is available, you have to configure the date and time manually.

For correct display of the current time, the Timezone offset must be set appropriately. This is the time offset from UTC (Coordinated Universal Time). If, for instance, the phone is located in Munich, Germany, the offset is +1 (or simply 1); if it is located in Los Angeles, USA, the offset is -8. For countries or areas with half-our time zones, like South Australia or India, non-integer values can be used, for example 10.5 for South Australia (UTC +10:30).

If the phone is located in a country with daylight saving, the administrator can choose whether daylight saving time is activated manually or automatically. If Daylight saving is enabled, and Auto time change is disabled, daylight saving time (DST) is in effect immediately. If Auto time change is enabled, daylight saving is controlled by the Time zone parameter. This selects the daylight saving time zone which is characterized by the start and end date for daylight saving time.

The Difference (minutes) provides the time difference for daylight saving time in minutes. This parameter is required also when Auto time change is enabled. In Germany, for instance, as in most countries, this is +60.

3.5.4.1 SNTP is available, but no automatic configuration by DHCP server

  • SNTP IP address : IP address or hostname of the SNTP server.
  • Timezone offset (hours) : Shift in hours corresponding to UTC.
  • Daylight saving : Enables or disables daylight saving time in conjunction with Auto time change . Value range: "Yes", "No".
  • Difference (minutes) : Time difference when daylight saving time is in effect.
  • Auto time change / Auto DST : Enables or disables automatic control of daylight saving time according to the Time zone . Value range: "Yes", "No".
  • Time zone / DST zone : Area with common start and end date for daylight saving time. Value range: "Australia 2007 (ACT, South Australia, Tasmania, Victoria)", "Australia 2007 (New South Wales)", "Australia (Western Australia)", "Australia 2008+ (ACT, New South Wales, South Australia, Tasmania, Victoria)", "Brazil", "Canada", "Canada (Newfound land)", "Europe (Portugal, United Kingdom)", "Europe (Finland)", "Europe (Rest)", "Mexi co", "United States".

System Settings · Data required

Page 73 of the Siemens 8000 user manual — 3.5.4 Date and Time
Seite 73 · Zum Vergrößern klicken
Seite 73
Siemens 8000 — 3.5.4 Date and Time diagram (page 73)
Abb. 53 · 3.5.4 Date and Time

Administration via Local Phone

|--- Administration |--- Date and Time |--- SNTP IP address |--- Timezone offset

Administration System Settings · Administration via WBM · Date and Time

Page 74 of the Siemens 8000 user manual — >
Seite 74 · Zum Vergrößern klicken
Seite 74

3.5.4.2 No SNTP server available

If no SNTP server is available, date and time must be set manually.

>

The manual setting of Time and Date is located in the user menu, not in the administrator menu.

  • Local time (hh:mm) : Local time.
  • Local date (day, month, year) : Local date.
  • Allow daylight saving : Defines whether there is daylight is set.
  • Difference (minutes) : Timezone offset in minutes.

(User pages >) Date and time

Siemens 8000 — > diagram (page 74)
Abb. 54

Administration via Local Phone

|--- Menu |--- Date and Time |--- Time |--- Date |--- Daylight saving |--- Difference (mins)

System Settings · Data required · Administration via WBM

Page 75 of the Siemens 8000 user manual — 3.5.5 SIP Addresses and Ports
Seite 75 · Zum Vergrößern klicken
Seite 75

3.5.5 SIP Addresses and Ports

3.5.5.1 SIP Addresses

In this group of parameters, the IP addresses or host names for the SIP server, the SIP regis trar, and the SIP gateway are defined.

SIP server address provides the IP address or host name of the SIP proxy server (Hipath 8000). This is necessary for outgoing calls. SIP registrar address contains the IP address or host name of the registration server, to which the phone will send REGISTER messages. When registered, the phone is ready to receive incoming calls. SIP gateway address gives the IP address or host name of the SIP gateway. The SIP gateway performs a conversion of SIP to TDM, which enables to phone directly into the public network.Data required

  • SIP server address : IP address or host name of the SIP proxy server.
  • SIP registrar address : IP address or host name of the registration server.
  • SIP gateway address : IP address or host name of the SIP gateway.
Siemens 8000 — 3.5.5 SIP Addresses and Ports diagram (page 75)
Abb. 55 · 3.5.5 SIP Addresses and Ports

Administration System Settings · Administration via WBM · System > Registration

Page 76 of the Siemens 8000 user manual — 3.5.5.2 SIP Ports
Seite 76 · Zum Vergrößern klicken
Seite 76

Administration via Local Phone

|--- Administration |--- System |--- Registration |--- SIP Addresses |--- SIP server |--- SIP registrar |--- SIP gateway

3.5.5.2 SIP Ports

In this group of parameters, the ports for the SIP server, the SIP registrar, and the SIP gateway are defined (for further information see Section 3.5.5.1, “SIP Addresses”), as well as the SIP port used by the phone (SIP local).

  • SIP server : Port of the SIP proxy server. Default: 5060.
  • SIP registrar : Port of the server at which the phone registers. Default: 5060.
  • SIP gateway : Port of the SIP gateway. Default: 5060.
  • SIP local : Port used by the phone for sending and receiving SIP messages. Default: 5060.

Network > Port configuration

Siemens 8000 — 3.5.5.2 SIP Ports diagram (page 76)
Abb. 56 · 3.5.5.2 SIP Ports

System Settings · Data required · Administration via WBM

Page 77 of the Siemens 8000 user manual — >
Seite 77 · Zum Vergrößern klicken
Seite 77

Administration via Local Phone

|--- Administration |--- Network |--- Port Configuration |--- SIP server |--- SIP registrar |--- SIP gateway |--- SIP local

3.5.6 SIP Registration

Registration is the process by which centralized SIP Server/Registrars become aware of the existence and readiness of an endpoint to make and receive calls. The phone supports a num ber of configuration parameters to allow this to happen. Registration can be authenticated or un-authenticated depending on how the server and phone is configured.

For unauthenticated registration, the following parameters must be set on the phone: Terminal number or Terminal name (see Section 3.5.1.1, “Terminal Identity”), SIP server and SIP regis trar address (see Section 3.5.5.1, “SIP Addresses”). Moreover, the correct Server type must be set. Additionally, the expiry time of a registration can be specified by Registration timer.

In unauthenticated mode, the server must pre-authenticate the user. This procedure is server specific and is not described here.

The phone supports the digest authentication scheme and requires some parameters to be configured in addition to those for unauthenticated registration. By providing a User ID and a Password which match with a corresponding account on the SIP registrar, the phone authen ticates itself. Optionally, a Realm can be added. This parameter specifies the protection domain wherein the SIP authentication is meaningful. The protection domain is globally unique, so that each protection domain has its own arbitrary usernames and passwords.

>

A challenge from the server for authentication information is not only restricted to the REGISTER message, but can also occur in response to other SIP messages, e. g. INVITE.

>

If registration has not succeeded at startup or registration fails after having been pre viously successfully registered the phone will try to re-register every 30 seconds. This is not configurable.

Administration System Settings · Unauthenticated Registration · Authenticated Registration

Page 78 of the Siemens 8000 user manual — 3.5.6 SIP Registration
Seite 78 · Zum Vergrößern klicken
Seite 78
  • Registration timer (seconds) : Expiry time of the registration in seconds. Default value: 3600.
  • Server type : Type of server the phone will register to. Value range: "Other", "HiQ8000". Default value: "HiQ8000".
  • Realm : Protection domain for authentication.
  • User ID : Username required for an authenticated registration.
  • Password : Password required for an authenticated registration.
Siemens 8000 — 3.5.6 SIP Registration diagram (page 78)
Abb. 57 · 3.5.6 SIP Registration

Administration via Local Phone

|--- Administration |--- System |--- Registration |--- SIP Session |--- Registration timer |--- Server type |--- Realm |--- User ID |--- Password

Show 4 more labels / short text on this page
System Settings · Data required · Administration via WBM · System > Registration
Page 79 of the Siemens 8000 user manual — 3.5.7 SIP Connection and Communication
Seite 79 · Zum Vergrößern klicken
Seite 79

3.5.7 SIP Connection and Communication

3.5.7.1 Response Timer

The Response timer is started whenever the phone sends a new message to the SIP server. If the timer expires before the phone gets a response from the SIP server, the phone assumes that the server had died and then attempts to contact the backup server, if configured. If there is no backup server configured, the phone just tidies up internally.

The data is given in milliseconds. The default value is 32 000; for the HiPath 8000, the recom mended setting is 3.7 seconds (3700 ms).

System > SIP interface

Siemens 8000 — 3.5.7 SIP Connection and Communication diagram (page 79)
Abb. 58 · 3.5.7 SIP Connection and Communication

Administration via Local Phone

|--- Administration |--- System |--- SIP Interface |--- Response timer (ms)

3.5.7.2 Connectivity Check

A regular check ensures that the TLS link is active. When the Connectivity check timer is set to a non-zero value, test messages will be sent at the defined interval. If the link is found to be dead, the phone searches for another links.

System > SIP interface

Siemens 8000 — 3.5.7 SIP Connection and Communication diagram (page 79)
Abb. 59 · 3.5.7 SIP Connection and Communication

Administration System Settings · Administration via WBM · Administration via WBM

Page 80 of the Siemens 8000 user manual — 3.5.7.3 Outbound Proxy
Seite 80 · Zum Vergrößern klicken
Seite 80

3.5.7.3 Outbound Proxy

If this option set to "Yes", the phone routes outbond requests to the configured proxy, i. e. the SIP server/registrar. The outbound proxy will fulfill the task of resolving the domain contained in the SIP request. If "No" is set, the phone will attempt to resolve the domain by itself.

If a Default OBP (Outbound Proxy) domain is set and the number or name dialed by the user does not provide a domain, this value will be appended to the name or number. Otherwise, the domain of the outbound proxy will be appended.

  • Outbound proxy : Determines whether an outbound proxy is used or not. Value range: "Yes", "No". Default: "No".
  • Default OBP domain : Alternative value for the domain that is given in the outbound re quest.

System > SIP interface

Siemens 8000 — 3.5.7.3 Outbound Proxy diagram (page 80)
Abb. 60 · 3.5.7.3 Outbound Proxy

Administration via Local Phone

|--- Administration |--- System |--- SIP Interface |--- Outbound proxy |--- Default OBP domain

System Settings · Data required · Administration via WBM

Page 81 of the Siemens 8000 user manual — 3.5.7.4 SIP Transport Protocol
Seite 81 · Zum Vergrößern klicken
Seite 81

3.5.7.4 SIP Transport Protocol

Selects the transport protocol to be used for SIP messages. The values "UDP", "TCP", and "TLS" are available. The default is "UDP".

System > SIP interface

Siemens 8000 — 3.5.7.4 SIP Transport Protocol diagram (page 81)
Abb. 61 · 3.5.7.4 SIP Transport Protocol

Administration via Local Phone

|--- Administration |--- System |--- SIP Interface |--- SIP transport

Administration System Settings · Administration via WBM

Page 82 of the Siemens 8000 user manual — >
Seite 82 · Zum Vergrößern klicken
Seite 82

3.5.8 SIP Session Timer

Session timers provide a basic keep-alive mechanism between 2 user agents or phones. This mechanism can be useful to the endpoints concerned or for stateful proxies to determine that a session is still alive. This is achieved by the phone sending periodic re-INVITEs to keep the session alive. If no re-INVITE is received before the interval passes, the session is considered terminated. Both phones are supposed to terminate the call, and stateful proxies can remove any state for the call.

This feature is sufficiently backward compatible such that only one end of a call needs to im plement the SIP extension for it to work.

The parameter Session timer enabled determines whether the mechanism shall be used, and Session duration (seconds) sets the expiration time, and thus the interval between refresh re-INVITEs.

>

Some server environments support their own mechanism for auditing the health of a session (e. g. Broadsoft). In these cases, the Session timer must be deactivated.

  • Session timer enabled : Activates or deactivates the session timer mechanism. Value range: "Yes", "No". Default value: "No".
  • Session duration (seconds) : Sets the expiration time for a SIP session. Default: 3600.

System Settings · Data required

Page 83 of the Siemens 8000 user manual — 3.5.8 SIP Session Timer
Seite 83 · Zum Vergrößern klicken
Seite 83
Siemens 8000 — 3.5.8 SIP Session Timer diagram (page 83)
Abb. 62 · 3.5.8 SIP Session Timer

Administration via Local Phone

|--- Administration |--- System |--- Registration |--- SIP session |--- Session timer |--- Session duration

Administration System Settings · Administration via WBM · System > Registration

Page 84 of the Siemens 8000 user manual — 3.5.9 SIP Survivability
Seite 84 · Zum Vergrößern klicken
Seite 84

3.5.9 SIP Survivability

The survivability feature will allow the SIP User Agent to register with a backup SIP proxy which will be used to make and receive calls when the primary SIP proxy fails or is not reachable due to a network failure.

The prime reason for this feature is to maintain basic call functionality when network failures occur, and it is therefore expected that some features and functionality will not be available when working in survivability mode.

The Backup registration flag indicates whether or not the phone treats the backup proxy serv er as a SIP registrar. If set to "Yes", the phone tries to register its SIP address with the server whose IP address or hostname is specified by Backup proxy address.

The Backup registration timer determines the duration of a registration with the SIP server.

The Backup transport option displays the current transport protocol used to carry SIP mes sages to the Backup proxy server.

The Backup OBP flag indicates whether or not the Backup proxy server is used as an out bound proxy.

  • Backup registration flag : Determines whether or not the backup proxy is used as a SIP Registrar. Value Range: "Yes", "No". Default: "Yes".
  • Backup proxy address : IP address or hostname of the backup proxy server.
  • Backup registration timer : Expiry time of the registration in seconds. Default: 3600.
  • Backup transport : Transport protocol to be used for messages to the backup proxy. Value range: "TCP", "UDP", "TLS". Default: "UDP".
  • Backup OBP flag : Determines whether or not the backup proxy is used as an outbound proxy. Value range: "Yes", "No". Default: "No".
  • Network > Port Configuration > Backup proxy : Port of the backup proxy server. Default: 5060.

System Settings · Data required

Page 85 of the Siemens 8000 user manual — 3.5.9 SIP Survivability
Seite 85 · Zum Vergrößern klicken
Seite 85
Siemens 8000 — 3.5.9 SIP Survivability diagram (page 85)
Abb. 63 · 3.5.9 SIP Survivability

Network > Port configuration

Siemens 8000 — 3.5.9 SIP Survivability diagram (page 85)
Abb. 64 · 3.5.9 SIP Survivability

Administration System Settings · Administration via WBM · System > Registration

Page 86 of the Siemens 8000 user manual — 3.5.9 SIP Survivability
Seite 86 · Zum Vergrößern klicken
Seite 86

Administration via Local Phone

|--- Administration |--- System |--- Registration |--- SIP Session |--- SIP Survivability |--- Backup registration flag |--- Backup proxy address |--- Backup transport |--- OBP flag

|--- Administration |--- Network |--- Port Configuration |--- Backup proxy

System Settings

Page 87 of the Siemens 8000 user manual — 3.6 Features - Configuration
Seite 87 · Zum Vergrößern klicken
Seite 87

Administration Features - Configuration

3.6 Features - Configuration

3.6.1 Allow Refuse

This parameter defines whether the Refuse Call feature is available on the phone. The possible values are "Yes" or "No". The default is "Yes".

Administration via WBM (V1R2.x)

System > Features > Configuration

Siemens 8000 — 3.6 Features - Configuration diagram (page 87)
Abb. 65 · 3.6 Features - Configuration

Administration via WBM (V1R3.x upwards)

System > Features > Configuration

Siemens 8000 — 3.6 Features - Configuration diagram (page 87)
Abb. 66 · 3.6 Features - Configuration
Page 88 of the Siemens 8000 user manual — 3.6 Features - Configuration
Seite 88 · Zum Vergrößern klicken
Seite 88

Administration via Local Phone

|--- Administration |--- System |--- Features |--- Configuration |--- General |--- Allow refuse

Features - Configuration

Page 89 of the Siemens 8000 user manual — 3.6.2 Group Pickup
Seite 89 · Zum Vergrößern klicken
Seite 89

Administration Features - Configuration

3.6.2 Group Pickup

3.6.2.1 Feature Code

This feature allows a user to collect a call from any ringing phone that is in the same pickup group. To be a member of a Call Pickup group, the phone must be configured with the corre sponding URI of the Call Pickup group service provided by the server. This URI has the follow ing form: @ (for instance **[email protected] or Domain Name).

System > Features > Addressing

Siemens 8000 — 3.6.2 Group Pickup diagram (page 89)
Abb. 67 · 3.6.2 Group Pickup

Administration via Local Phone

|--- Administration |--- System |--- Features |--- Addressing |--- Group pickup URI

Administration via WBM

Page 90 of the Siemens 8000 user manual — 3.6.2.2 Pickup alert (V1R3.x upwards)
Seite 90 · Zum Vergrößern klicken
Seite 90

3.6.2.2 Pickup alert (V1R3.x upwards)

If desired, an incoming call for the pickup group can be indicated acoustically.

The Group pickup tone allowed parameter activates or deactivates the generation of an acoustic signal for incoming pickup group calls. The default is "Yes". If this is activated, Group pickup as ringer determines whether the current ringtone or an alert beep is used. If set to "Yes", a pickup group call will be signaled by a short standard ringtone. If set to "No", a pickup group call will be signaled by an alert tone. The default is "Yes".

Group pickup visual alert defines the user action required to accept a pickup call. If "Prompt" is selected, an incoming pickup call is signaled by an alert on the phone GUI. As soon as the user goes off-hook or presses the speaker key, the pickup call is accepted. Alternatively, the user can press the corresponding function key, if configured. If "Notify" is selected, an incoming pickup call is signaled by an alert on the phone GUI. To accept the call, the user must confirm the alert or press the corresponding function key, if configured.

System > Features > Configuration

Siemens 8000 — 3.6.2.2 Pickup alert (V1R3.x upwards) diagram (page 90)
Abb. 68 · 3.6.2.2 Pickup alert (V1R3.x upwards)

Features - Configuration · Administration via WBM

Page 91 of the Siemens 8000 user manual — 3.6.2.2 Pickup alert (V1R3.x upwards)
Seite 91 · Zum Vergrößern klicken
Seite 91

Administration Features - Configuration

Administration via Local Phone

|--- Administration |--- System |--- Features |--- Configuration |--- Audio |--- Group pickup tone allowed |--- Group pickup as ringer |--- Group pickup visual alert

Page 92 of the Siemens 8000 user manual — 3.6.3 Call Transfer
Seite 92 · Zum Vergrößern klicken
Seite 92

3.6.3 Call Transfer

3.6.3.1 Transfer on Ring

If this function is active, a call can be transferred after the user has dialled the third participant’s number, but before the third party has answered the call. This feature is enabled or disabled in the User menu. The default is "Yes".

(User) Configuration > Outgoing calls

Siemens 8000 — 3.6.3 Call Transfer diagram (page 92)
Abb. 69 · 3.6.3 Call Transfer

Administration via Local Phone

|--- User |--- Configuration |--- Outgoing calls |--- Transfer on ring

3.6.3.2 Transfer on Hangup

This feature applies to the following scenario: While A is talking to B, C calls A. A accepts the call, so B is on hold and the call between A and C is active. If Transfer on hangup is enabled, and A goes on-hook, B gets connected to C.

If Transfer on hangup is disabled, C will be released when A hangs up, and A has the possibility to reconnect to B.

The default is "No".

Features - Configuration · Administration via WBM

Page 93 of the Siemens 8000 user manual — 3.6.3 Call Transfer
Seite 93 · Zum Vergrößern klicken
Seite 93

Administration Features - Configuration

Administration via WBM (V1R2.x)

System > Features > Configuration

Siemens 8000 — 3.6.3 Call Transfer diagram (page 93)
Abb. 70 · 3.6.3 Call Transfer

Administration via WBM (V1R3.x upwards)

System > Features > Configuration

Siemens 8000 — 3.6.3 Call Transfer diagram (page 93)
Abb. 71 · 3.6.3 Call Transfer

Administration via Local Phone

|--- Administration |--- System |--- Features |--- Configuration |--- General |--- Transfer on hangup

Page 94 of the Siemens 8000 user manual — 3.6.4 Callback URIs
Seite 94 · Zum Vergrößern klicken
Seite 94

3.6.4 Callback URIs

The Callback option allows the user to request a callback on certain conditions. The callback request is sent to the SIP server. The Code for callback busy requests a callback if the line is busy, i. e. if there is a conversation on the remote phone. Code for callback no reply applies when the call is not answered, i. e. if nobody lifts the handset or accepts the call in another way. The Code for callback cancel all all deletes all the callback requests stored previously on the telephone system/SIP server.

  • Code for callback busy / Callback: Busy : Access code that is sent to the server if the line is busy.
  • Code for callback no reply / Callback: No reply : Access code that is sent to the server if the callee does not reply.
  • Code for callback cancel all / Callback: Cancel all : Access code for canceling all call back requests on the server.

System > Features > Services

Siemens 8000 — 3.6.4 Callback URIs diagram (page 94)
Abb. 72 · 3.6.4 Callback URIs

Administration via Local Phone

|--- Administration |--- System |--- Features |--- Addressing |--- Callback: Busy |--- Callback: No reply |--- Callback: Cancel all

Features - Configuration · Data required · Administration via WBM

Page 95 of the Siemens 8000 user manual — 3.6.5 Message Waiting Address
Seite 95 · Zum Vergrößern klicken
Seite 95

Administration Features - Configuration

3.6.5 Message Waiting Address

The MWI (Message Waiting Indicator) is an optical signal which indicates that voicemail mes sages are on the server. Depending on the SIP server / gateway in use, the Message waiting server address, that is the address or host name of the server that sends message waiting notifications to the phone, must be configured.

With HiPath 8000, this setting is not typically necessary for enabling MWI functionality.

System > Features > Services

Siemens 8000 — 3.6.5 Message Waiting Address diagram (page 95)
Abb. 73 · 3.6.5 Message Waiting Address

Administration via Local Phone

|--- Administration |--- System |--- Features |--- Addressing |--- MWI server URI

Administration via WBM

Page 96 of the Siemens 8000 user manual — >
Seite 96 · Zum Vergrößern klicken
Seite 96

3.6.6 System Based Conference

The Conference URI provides the number/URI used for system based conferences, which can involve more than three members. This feature is not available with every system.

>

It is recommended not to enter the full URI, but only the user part. For instance, enter "123", not "123@". A full address in this place might cau se a conflict when the HiPath 8000 uses multiple nodes.

System > Features > Services

Siemens 8000 — > diagram (page 96)
Abb. 74

Features - Configuration · Administration via WBM

Page 97 of the Siemens 8000 user manual — 3.6.7 Server Based Features (V1R3.x upwards)
Seite 97 · Zum Vergrößern klicken
Seite 97

Administration Features - Configuration

3.6.7 Server Based Features (V1R3.x upwards)

The use of several server based features, such as server based DND (Do Not Disturb) and server based call forwarding, is enabled or disabled here.

System > Features > Configuration

Siemens 8000 — 3.6.7 Server Based Features (V1R3.x upwards) diagram (page 97)
Abb. 75 · 3.6.7 Server Based Features (V1R3.x upwards)

Administration via Local Phone

|--- Administration |--- System |--- Features |--- Configuration |--- General |--- Server features

Administration via WBM

Page 98 of the Siemens 8000 user manual — 3.6.8 uaCSTA Interface
Seite 98 · Zum Vergrößern klicken
Seite 98

3.6.8 uaCSTA Interface

User Agent CSTA (uaCSTA) is a limited subset of the CSTA protocol, which allows external CTI applications to interact with the phone.

If Allow uaCSTA is enabled, applications which support the uaCSTA standard will have access to the OpenStage phone. The default is "Yes".

Administration via WBM (V1R2.x)

System > Features > Configuration

Siemens 8000 — 3.6.8 uaCSTA Interface diagram (page 98)
Abb. 76 · 3.6.8 uaCSTA Interface

Administration via WBM (V1R3.x upwards)

System > Features > Configuration

Siemens 8000 — 3.6.8 uaCSTA Interface diagram (page 98)
Abb. 77 · 3.6.8 uaCSTA Interface

Features - Configuration

Page 99 of the Siemens 8000 user manual — 3.6.8 uaCSTA Interface
Seite 99 · Zum Vergrößern klicken
Seite 99

Administration Features - Configuration

Administration via Local Phone

|--- Administration |--- System |--- Features |--- Configuration |--- General |--- Allow uaCSTA

Page 100 of the Siemens 8000 user manual — 3.6.9 Local Menu Timeout
Seite 100 · Zum Vergrößern klicken
Seite 100

3.6.9 Local Menu Timeout

The timeout for the local user and admin menu is configurable. When the time interval is over, the menu is closed and the administrator/user is logged out.

The timeout may be helpful in case a user does a long press on a line key unintentionally, and thereby invokes the key configuration menu. The menu will close after the timeout, and the key will return to normal line key operation.

The timeout ranges from 1 to 5 five minutes. The default value is 2.

Administration via WBM (V1R2.x)

System > Features > Configuration

Siemens 8000 — 3.6.9 Local Menu Timeout diagram (page 100)
Abb. 78 · 3.6.9 Local Menu Timeout

Administration via WBM (V1R3.x upwards)

System > Features > Configuration

Siemens 8000 — 3.6.9 Local Menu Timeout diagram (page 100)
Abb. 79 · 3.6.9 Local Menu Timeout

Features - Configuration

Page 101 of the Siemens 8000 user manual — 3.6.9 Local Menu Timeout
Seite 101 · Zum Vergrößern klicken
Seite 101

Administration Features - Configuration

Administration via Local Phone

|--- Administration |--- System |--- Features |--- Configuration |--- General |--- Not used timeout

Page 102 of the Siemens 8000 user manual — 3.7.1 Line key configuration
Seite 102 · Zum Vergrößern klicken
Seite 102

3.7 Multiline Appearance/Keyset

>

This feature is available only on OpenStage 40 and OpenStage 60/80 phones.

A phone that has more than one line associated to it, and therefore works as a multiline phone, is referred to as "keyset". The lines are assigned to the phone by setting up a separate line key for each line.

The multiline appearance feature allows for multiple lines to be assigned to a keyset and for a line to be assigned to multiple keysets. This feature requires configuration in the HiPath 8000 and in the telephone, and is particularly useful for executive-assistant arrangements.

For each keyset, a primary line is required. The primary line is the dialing number for that key set.

  • There are two types of line:
  • Private line : A line that appears on only one keyset.
  • Shared line : A line that is shared between keysets.

3.7.1 Line key configuration

A line corresponds to a SIP address of record (AoR), which can have a form similar to an E- mail address, or can be a phone number. It is defined by the Address of record parameter. For registration of the line, a corresponding entry must exist on the SIP server resp. the SIP registrar server.

A label can be assigned to the line key by setting its Key label.

Every keyset must necessarily have a line key for the primary line. To configure the key of the primary line, set Primary line to "true".

If Ring on/off is checked, the line will ring when an incoming call occurs, and a popup will ap pear on the display. If the option is not checked, the incoming call will be indicated only by the blinking of the key’s LED. If it is desired that the line ring with a delay, the time interval in sec onds can be configured by Ring delay.

When the user lifts the handset in order to initiate a call, the line to be used is determined by selection rules. To each line, a priority is assigned by the Selection order parameter. A line with the rank 1 is the first line to be considered for use. If more than one lines have the same rank, the selection is made according to the key number. Note that Selection order is a manda tory setting; it is also used in the Terminating line preference, as well as in other functions.

The Address (Address of Record) parameter gives is the phone number resp. SIP name cor responding to the entry in the SIP registrar at which the line is to be registered.

Multiline Appearance/Keyset

Page 103 of the Siemens 8000 user manual — >
Seite 103 · Zum Vergrößern klicken
Seite 103

>

For the configuration of line keys, the use of the DLS (Deployment Service) is recom mended. For operating the DLS, please refer to the DLS user’s guide. Alternatively, the web interface or the local menu can be used. Note that the creation of a new line key and the configuration of some parameters can not be accomplished by the pho ne’s local menu. Generally, it is advisable to restrict the user’s possibilities to modify line keys. This can be achieved solely by the DLS. For further instructions, see the DLS Administra tion Guide.

The Realm, a protection domain used for authenticated access to the SIP server, works as a name space. Any combination of user id and password is meaningful only within the realm it is assigned to. The other parameters necessary for authenticated access are User Identifier and Password. For all three parameters, there must be corresponding entries on the SIP server.

The Shared type parameter determines whether the line is a shared line, i. e. shared with other endpoints, or a private line, i .e. available exclusively for this endpoint. A line that is configured as primary line on one phone can be configured as secondary line on other phones.

When Allow in Overview is set to "Yes", the line will be visible in the line overview on the phone’s display.

  • Key label <n> : Set the label of the line key with the key number <n>. Default: "Line".
  • Primary line : Determines whether the line is the primary line. Value range: "Yes", "No". Default: "No".
  • Ring on/off : Determines whether the line rings on an incoming call. Value range: "On", "Off". Default: "On".
  • Ring delay : Time interval in seconds after which the line starts ringing on an incoming call. Default: 0.
  • Selection order : Priority assigned to the line for the selection of an outgoing line. Default: 0.
  • Address : Address/phone number which has a corresponding entry on the SIP server/ registrar.
  • Realm : Domain wherein user id and password are valid.
  • User Identifier : User name for authentication with the SIP server.
  • Password : Password for authentication with the SIP server.

Administration Multiline Appearance/Keyset · Data required

Page 104 of the Siemens 8000 user manual — >
Seite 104 · Zum Vergrößern klicken
Seite 104
  • Shared type : Determines whether the line is a shared line (shared by multiple endpoints) or a private line (only available for this endpoint). Value range: "shared", "private", "unknown". Default: "shared".
  • Allow in Overview : Determines whether the line appears in the phone’s line overview. Value range: "Yes", "No". Default: "Yes".

A new line key can only be added by use of the WBM or, preferably, the DLS. Once a line key exists, it can also be configured by the local menu.

>

1. Invoke the "Phone keys" dialog and select "line" in the pulldown menu of the key you want to configure. Next, press "Edit...".

Features > Program keys

Siemens 8000 — > diagram (page 104)
Abb. 80

Multiline Appearance/Keyset · Administration via WBM

Page 105 of the Siemens 8000 user manual — 3.7 Multiline Appearance/Keyset
Seite 105 · Zum Vergrößern klicken
Seite 105
2. In the "Line" dialog, set the specific parameters for the line key.
Siemens 8000 — 3.7 Multiline Appearance/Keyset diagram (page 105)
Abb. 81 · 3.7 Multiline Appearance/Keyset

Administration via Local Phone

The configuration of a line via Local phone is only possible when the line key has been created via Web interface or DLS before.

|--- Administration |--- System |--- Features |--- Configuration |--- Keyset Lines |--- Details For Keyset Line |--- Address |--- Ring on/off |--- Selection order

Administration Multiline Appearance/Keyset

Page 106 of the Siemens 8000 user manual — >
Seite 106 · Zum Vergrößern klicken
Seite 106

3.7.2 Configure Keyset Operation

The following parameters provide general settings which are common for all keyset lines.

The Rollover ring setting will be used in the case that, during an active call, an incoming call arrives on a different line. If "no ring" is selected, the incoming call will not initiate a ring. If "alert ring" is selected, a special alert ringtone is activated on an incoming call; "alert beep" selects a beep instead of a ringtone. "Standard ringtone" selects the default ringtone.

LED on registration determines whether the line LEDs will be lit for a few seconds if they have been registered successfully with the SIP server on phone startup.

The Originating line preference parameter determines which line will be used when the user goes off-hook or starts on-hook dialing.

>

When a terminating call exists, the terminating line preference takes priority over originating line preference.

The following preferences can be configured:

  • "idle line": An idle line is selected. The selection is based on the Hunt ranking param eter assigned to each line (see Section 3.7.1, “Line key configuration”).
  • "primary": The designated Primary Line is always selected for originating calls.
  • "last": The line selected for originating calls is the line that has been used for the last call (originating or terminating).
  • "none": The user manually selects a line by pressing its line key before going off-hook, or by pressing the speaker key, to originate a call. Manual line selection overrides au tomatic line preferences.

The Terminating line preference parameter decides which terminating line, i. e. line with an incoming call, is selected when the user goes off-hook.

The following preferences can be configured:

  • "ringing line": The line in the alerting or audible ringing state is automatically selected when the user goes off-hook. In the case of multiple lines alerting or ringing, the lines are selected on the one that has been alerting the longest.
  • "ringing PLP": The line in the alerting or audible ringing state is automatically selected when the user goes off-hook. However, if the prime line is alerting, it is given priority.
  • "incoming": The earliest line to start audible ringing is selected, or else the earliest alerting (ringing suppression ignored) line is selected.
  • "incoming PLP": The earliest line to start audible ringing is selected, or else the earliest alerting (ringing suppression ignored) line is selected. However, if the prime line is alerting, it is given priority.

Multiline Appearance/Keyset

Page 107 of the Siemens 8000 user manual — 3.7.2 Configure Keyset Operation
Seite 107 · Zum Vergrößern klicken
Seite 107
  • "none": To answer a call, the user manually selects a line by pressing its line key before going off-hook, or by pressing the speaker key. Manual line selection overrides auto matic line preferences.

Line action mode determines the consequence for an established connection when the line key is pressed. If "hold" is selected, the call currently active is set to hold as soon as the line key is activated. The user has two options: 1) to reconnect to the remote phone by pressing the line key that corresponds to that call, or 2) to initiate another call from the newly selected line. If "release" is selected, the previously established call is ended.

If Show Focus is checked, the LED of a line key flutters when the line is in use. If it is not checked, the line key is lit steady when it is in use.

The Reservation timer sets the period after which the reservation of a line is canceled. A line is automatically reserved for the keyset whenever the user has selected a line for an outgoing call and hears a dial tone. The reservation of a line is accomplished by the HiPath 8000 server, which notifies all the endpoints sharing this line. If set to 0, the reservation timer is deactivated.

Forward indication activates or deactivates the indication of station forwarding, i. e. the for warding function of the HiPath 8000. If Forward indication is activated and station forwarding is active for the corresponding line, the LED of the line key blinks.

Preselect mode determines the phone’s behaviour when a call is active, and another call is ringing. If the parameter is set to "Single button", the user can accept the call a single press on the line key. If it is set to "Preselection", the user must first press the line key to select it and then press it a second time to accept the call. In both cases, the options for a ringing call are presented to the user: "Accept", "Reject", "Deflect".

Preselect timer sets the timeout for an incoming call. After the timeout has expired, the call is no longer available.

  • Rollover ring : Determines if a ringtone will signal an incoming call while a call is active. Value range: "No ring", "Alert beep", "Alert ring". Default: "Alert beep".
  • LED on registration : Determines if line LEDs will signal SIP registration. Value range: "Yes", "No". Default: "Yes".
  • Originating line preference : Selects the line to be used for outgoing calls. Value range: "Idle line", "Primary", "Last", "None". Default: "Idle line".
  • Terminating line preference : Determines which line with an incoming call shall be select ed for answering. Value range: "Ringing line", "Incoming", "Incoming PLP", "Ringing PLP", "None". Default: "Idle line".

Administration Multiline Appearance/Keyset · Data required

Page 108 of the Siemens 8000 user manual — 3.7.2 Configure Keyset Operation
Seite 108 · Zum Vergrößern klicken
Seite 108
  • Line action mode : Determines the consequence for an established connection when the line key is pressed. Value range: "Hold", "Release". Default: "Hold".
  • Show focus : Determines whether the line Key LED blinks or is steady when it is in use. Value range: "Yes", "No". Default: "Yes".
  • Reservation timer : Sets the period in seconds after which a line reservation is cancelled. If set to 0, the reservation timer is deactivated. Default: 60.
  • Forward indication : Activates or deactivates the indication of station forwarding. Value range: "Yes", "No". Default: "No".
  • Preselect mode : Determines whether an incoming call is accepted by a single press on the corresponding line key or a double press is needed. Value range: "Single button", "Preselection". Default: "Single button".
  • Preselect timer : Sets the timeout in seconds for accepting an incoming call.

Multiline Appearance/Keyset

Page 109 of the Siemens 8000 user manual — 3.7.2 Configure Keyset Operation
Seite 109 · Zum Vergrößern klicken
Seite 109

System > Features > Keyset Operation

Siemens 8000 — 3.7.2 Configure Keyset Operation diagram (page 109)
Abb. 82 · 3.7.2 Configure Keyset Operation

Administration via Local Phone

|--- Administration |--- System |--- Features |--- Keyset operation |--- Rollover ring |--- LED on registration |--- Originating line preference |--- Terminating line preference |--- Line action mode |--- Show focus |--- Reservation timer |--- Forward indicated |--- Preselect mode |--- Preselect timer

Administration Multiline Appearance/Keyset · Administration via WBM

Page 110 of the Siemens 8000 user manual — >
Seite 110 · Zum Vergrößern klicken
Seite 110

3.7.3 Direct Station Select (DSS)

>

This feature is available only on OpenStage 40/60/80, and requires HiPath V 3.0.

A DSS key is a special variant of a line key. It enables a direct connection to a target phone, allowing the user to pick up or forward a call alerting the DSS target and make/complete a call to the DSS target.

3.7.3.1 General DSS Settings

These parameters define the behaviour of all DSS keys.

Generally, it is advisable to restrict the user’s possibilities to modify line keys, includ ing DSS keys. This can be achieved solely by the DLS. For further instructions, see the DLS Administration Guide.

>

If the user picks up an incoming call for the DSS target by pressing the associated DSS key, the call is forwarded to the user’s primary line. Thereafter, the user’s phone rings, and the user can accept the call.

To enable the immediate answering of a call via the DSS key, Allow auto-answer in the user menu must be activated. The complete path on the WBM is: User Pages > Configuration > Incoming calls > CTI calls > Allow auto-answer.

>

The value of Call pickup detect timer (seconds) determines the time interval, within which the call must be present at the primary line. If the interval is exceeded, forwarding will not be tried any longer. The default is 3.

If Deflecting call enabled is checked, the user can forward an alerting call to the DSS target by pressing the DSS key. The default is "No".

If Allow pickup to be refused is checked, the user is enabled to reject a call alerting on the line associated with the DSS key. The default is "No".

System > Features > DSS Settings

Siemens 8000 — > diagram (page 110)
Abb. 83

Multiline Appearance/Keyset · Administration via WBM

Page 111 of the Siemens 8000 user manual — 3.7.3.2 Settings for a DSS key
Seite 111 · Zum Vergrößern klicken
Seite 111

Administration via Local Phone

|--- Administration |--- System |--- Features |--- Feature Access |--- Call establish |--- Deflect to DSS |--- Refuse DSS pickup

|--- Administration |--- System |--- Features |--- Configuration |--- General |--- DSS Pickup timer

3.7.3.2 Settings for a DSS key

The Key label <n> parameter provides the DSS key with a label that is displayed on the graphic display on a OpenStage 60/80 phone. The label is also user configurable.

Address contains the call number of the line associated with the DSS key.

The Realm parameter stores the SIP Realm of the line associated with the DSS key.

User Identifier gives the SIP user ID of the line associated with the DSS key.

Password provides the password corresponding to the SIP user ID.

The Outgoing calls parameter determines the behaviour of a call over the DSS line at the tar get phone. If set to "Direct", any forwarding and Do not Disturb settings on the target phone will be overridden, so that a call will always alert. If set to Line type is set to "Normal", this is not the case, and the call will be treated like a regular call.

Action on calls defines the handling of an active call when pressing the DSS key. If set to "Consult", the user has an option to start a consultation with the DSS target. If set to "Transfer", the user can only transfer the call to the DSS target. If "No action" is selected, pressing the DSS key will have no effect.

When Allow in Overview is set to "Yes", the line corresponding to the DSS key will be visible in the line overview on the phone’s display.

  • Key label <key number> : Label to be displayed on the display. Default: "DSS".
  • Address : SIP Address of Record of the destination that is assigned to the DSS key.
  • Realm : SIP Realm of the DSS destination.

Administration Multiline Appearance/Keyset · Data required

Page 112 of the Siemens 8000 user manual — 3.7.3.2 Settings for a DSS key
Seite 112 · Zum Vergrößern klicken
Seite 112
  • User ID : SIP user ID of the DSS destination.
  • Password : Password corresponding to the SIP user ID.
  • Outgoing calls : Determines whether forwarding and DND at the target phone will be over ridden on a DSS call. Value range: "Normal", "Direct". Default: "Normal".
  • Action on calls : Handling of an active call when pressing the DSS key. "Consult": the user can start a consultation with the DSS target; "Transfer": the user can transfer the call to the DSS target. Value range: "Consult", "Transfer", "No action". Default: "Consult".
  • Allow in Overview : Determines whether the line appears in the phone’s line overview. Value range: "Yes", "No". Default: "Yes".

System > Features > Program keys > [edit]

Siemens 8000 — 3.7.3.2 Settings for a DSS key diagram (page 112)
Abb. 84 · 3.7.3.2 Settings for a DSS key

Multiline Appearance/Keyset · Administration via WBM

Page 113 of the Siemens 8000 user manual — 3.7.4 Key Modules
Seite 113 · Zum Vergrößern klicken
Seite 113

3.7.4 Key Modules

A Key module provides 12 additional program keys. It is available for the OpenStage 40, 60 and 80. A maximum of 2 key modules can be connected to one phone. The configuration of a key on the key module is just the same as the configuration of a phone key.

System > Features > Key module 1/2

Siemens 8000 — 3.7.4 Key Modules diagram (page 113)
Abb. 85 · 3.7.4 Key Modules
Siemens 8000 — 3.7.4 Key Modules diagram (page 113)
Abb. 86 · 3.7.4 Key Modules

Administration Multiline Appearance/Keyset · Administration via WBM

Page 114 of the Siemens 8000 user manual — >
Seite 114 · Zum Vergrößern klicken
Seite 114

3.8 Dialing

3.8.1 Canonical Dialing Configuration

Call numbers taken from a directory application, LDAP for instance, are mostly expressed in canonical format. Moreover, call numbers entered into the local phone book are automatically converted and stored in canonical format, thereby adding "+", Local country code, Local na tional code, and Local enterprise number as prefixes. If, for instance, the user enters the ex tension "1234", the local country code is "49", the local national code is "89", and the local en terprise number is "722", the resulting number in canonical format is "+49897221234".

For generating an appropiate dial string, a conversion from canonical format to a different for mat may be required. The following parameters determine the local settings of the phone, like Local country code or Local national code, and define rules for converting from canonical format to the format required by the PBX.

>

To enable the number conversion, all parameters not marked as optional must be provided, and the canonical dial lookup settings must be configured (see Section 3.8.2, “Canonical Dial Lookup”).

  • Local country code : E.164 Country code, e.g. "49" for Germany, "44" for United Kingdom. Maximum length: 5.
  • National prefix digit : Prefix for national connections, e.g. "0" in Germany and United King dom. Maximum length: 5.
  • Local national code : Local area code or city code, e.g. "89" for Munich, "20" for London. Maximum length: 6.
  • Minimal local number length : Minimum number of digits in a local PSTN number, e.g. 3335333 = 7 digits.
  • Local enterprise number : Number of the company/PBX wherein the phone is residing. Maximum length: 10. (Optional)
  • PSTN access code : Access code used for dialing out from a PBX to a PSTN. Maximum length: 10. (Optional)
  • International access code : International prefix used to dial to another country, e.g. "00" in Germany and United Kingdom. Maximum length: 5.
  • Operator codes : List of extension numbers for a connection to the operator. The numbers entered here are not converted to canonical format. Maximum length: 50. (Optional)
  • Emergency number : List of emergency numbers to be used for the phone. If there are more than one numbers, they must be separated by commas. The numbers entered here are not converted to canonical format. Maximum length: 50. (Optional)

Dialing · Data required

Page 115 of the Siemens 8000 user manual — >
Seite 115 · Zum Vergrößern klicken
Seite 115
  • From V1R4.x on, these emergency numbers can also be dialed when the phone is locked, in line with the emergency number configured in Features > Configuration (see Section 3.5.2, “Emergency and Voice Mail”).
  • Initial extension digits / Initial digits : List of initial digits of all possible extensions in the local enterprise network. When a call number could not be matched as a public network number, the phone checks if it is part of the local enterprise network. This is done by com paring the first digit of the call number to the value(s) given here. If it matches, the call num ber is recognized as a local enterprise number and processed accordingly. If, for instance, the extensions 3000-5999 are configured in the HiPath 8000, each number will start with 3, 4, or 5. Therefore, the digits to be entered are 3, 4, 5.
  • Internal numbers

>

To enable the phone to discern internal numbers from external numbers, it is crucial that a canonical lookup table is provided (Section 3.8.2, “Canonical Dial Lookup”).

  • "Local enterprise form": Default value. Any extension number is dialled in its simplest form. For an extension on the local enterprise node, the node ID is omitted. If the ex tension is on a different enterprise node, then the appropriate node ID is prefixed to the extension number. Numbers that do not correspond to an enterprise node exten sion are treated as external numbers.
  • "Always add node": Numbers that correspond to an enterprise node extension are al ways prefixed with the node ID, even those on the local node. Numbers that do not cor respond to an enterprise node extension are treated as external numbers.
  • "Use external numbers": All numbers are dialled using the external number form.
  • External numbers
  • "Local public form": Default value. All external numbers are dialled in their simplest form. Thus a number in the local public network region does not have the region code prefix. Numbers in the same country but not in the local region are dialled as national numbers. Numbers for a different country are dialled using the international format.
  • "National public form": All numbers within the current country are dialled as national numbers, thus even local numbers will have a region code prefix (as dialling from a mo bile). Numbers for a different country are dialled using the international format.
  • "International form": All numbers are dialled using their full international number for mat.
  • External access code
  • "Not required": The access code to allow a public network number to be dialled is not required.

Dialing

Page 116 of the Siemens 8000 user manual — 3.8 Dialing
Seite 116 · Zum Vergrößern klicken
Seite 116
  • "For external numbers": Default value. All public network numbers will be prefixed with the access code that allows a number a call to be routed outside the enterprise net work. However, international numbers that use the + prefix will not be given access code.
  • International gateway code :
  • "Use national code": Default value. All international formatted numbers will be dialled explicitly by using the access code for the international gateway to replace the "+" pre fix.
  • "Leave as +": All international formatted numbers will be prefixed with "+".

Local functions > Locality > Canonical dial settings

Siemens 8000 — 3.8 Dialing diagram (page 116)
Abb. 87 · 3.8 Dialing

Local functions > Locality > Canonical dial

Siemens 8000 — 3.8 Dialing diagram (page 116)
Abb. 88 · 3.8 Dialing

Dialing · Administration via WBM

Page 117 of the Siemens 8000 user manual — 3.8 Dialing
Seite 117 · Zum Vergrößern klicken
Seite 117

Administration via Local Phone

|--- Administration |--- Local Functions |--- Locality |--- Canonical dial settings |--- Local country code |--- National prefix digit |--- Local national code |--- Minimum local number length |--- Local enterprise node |--- PSTN access code |--- International access code |--- Operator code |--- Emergency number

|--- Administration |--- Local Functions |--- Locality |--- Canonical dial |--- Internal numbers |--- External numbers |--- External access code |--- International gateway

Dialing

Page 118 of the Siemens 8000 user manual — >
Seite 118 · Zum Vergrößern klicken
Seite 118

3.8.2 Canonical Dial Lookup

The parameters given here are important for establishing outgoing calls and for recognizing in coming calls.

In the local phonebook, and, mostly, in LDAP directories, numbers are stored in canonical for mat. In order to generate an appropriate dial string according to the settings in Internal num bers and External numbers (-> Section 3.8.1), internal numbers must be discerned from ex ternal numbers. The canonical lookup table provides patterns which allow for operation.

Furthermore, these patterns enable the phone to identify callers from different local or interna tional telephone networks by looking up the caller’s number in the phone book. As incoming numbers are not always in canonical format, their composition must be analyzed first. For this purpose, an incoming number is matched against one or more patterns consisting of country codes, national codes, and enterprise nodes. Then, the result of this operation is matched against the entries in the local phone book.

>

  • To make sure that canonical dial lookup works properly, at least the following para meters of the phone must be provided:
  • Local country code (-> Section 3.8.1)
  • Local area code (-> Section 3.8.1)
  • Local enterprise code (-> Section 3.8.1)

Up to 5 patterns can be defined. The Local code 1 ... 5 parameters define up to 5 different local enterprise nodes, whilst International code 1... 5 define up to 5 international codes, that is, fully E.164 call numbers for use in a PSTN.

  • Local code 1 ... 5 : Local enterprise code for the node/PBX the phone is connected to. Example: "722" for Siemens Munich.
  • International code 1 ... 5 : Sequence of "+", local country code, local area code, and local enterprise node corresponding to to one or more phone entries. Example: "+4989722" for Siemens Munich.

Locality > Canonical dial lookup

Siemens 8000 — > diagram (page 118)
Abb. 89

Dialing · Data required · Administration via WBM

Page 119 of the Siemens 8000 user manual — 3.8.2 Canonical Dial Lookup
Seite 119 · Zum Vergrößern klicken
Seite 119

Administration via Local Phone

|--- Administration |--- Local Functions |--- Locality |--- Canonical Dial Lookup |--- Local code 1 |--- International code 1 |--- Local code 2 |--- International code 2 |--- Local code 3 |--- International code 3 |--- Local code 4 |--- International code 4 |--- Local code 5 |--- International code 5

Dialing

Page 120 of the Siemens 8000 user manual — 3.9 Mobility
Seite 120 · Zum Vergrößern klicken
Seite 120

3.9 Mobility

The Mobility feature requires the HiPath Deployment Severice (DLS). If the phone is mobility enabled by the DLS, a mobile user can log on to the phone and thereby have his own user set tings transferred to the phone. These user data are stored in the DLS database and include, for instance, SIP registration settings, dialing properties, key layouts, as well as the user’s phone book.

If the mobile user changes some settings, the changed data is sent to the DLS server. This en sures that his user profile is updated if necessary.

If Unauthorized logoff trap is set to "Yes", a message is sent to the SNMP server if an unau thorized attempt is made to log off the mobile user.

Logoff trap delay defines the time span in seconds between the unauthorized logoff attempt and the trap message to the SNMP server.

Timer med priority determines the time span in seconds between a change of user data in the phone and the transfer of the changes to the DLS server.

The Mobility feature parameter indicates whether the mobility feature is enabled by the DNS or not.

  • Unauthorized logoff trap : An SNMP trap is sent on an unauthorized logoff attempt. Value range: "Yes", "No". Default: "No".
  • Logoff trap delay : Time span in seconds between the unauthorized logoff attempt and the SNMP trap. Default: 300.
  • Timer med priority : Time span in seconds between a data change in the phone and its transfer to the DLS server. Default: 60.
  • Mobility feature : Indicates whether the mobility feature is enabled.

Administration via Local Phone

|--- Administration |--- Mobility |--- Unauthorized logoff trap |--- Logoff trap delay |--- Timer med priority |--- Mobility feature

Mobility · Data required

Page 121 of the Siemens 8000 user manual — >
Seite 121 · Zum Vergrößern klicken
Seite 121

Administration Transferring Phone Software, Application and Media Files

3.10 Transferring Phone Software, Application and Media Files

New software images, hold music, picture clips for phonebook entries, LDAP templates, com pany logos, screensaver images, and ringtones can be uploaded to the phone via DLS (De ployment Service) or WBM (Web Based Management).

>

  • For all user data, which includes files as well as phonebook content, the following amounts of storage place are available:
  • OpenStage 20/40: 4 MB
  • OpenStage 60/80: 8 MB

3.10.1 FTP/HTTPS Server

There are no specific requirements regarding the FTP server for transferring files to the Open Stage phone. Any FTP server providing standard functionality will do.

3.10.2 Common FTP/HTTPS Settings

For each one of the various file types, e.g. phone software, hold music, and picture clips, spe cific FTP/HTTPS access data can be defined. If some or all file types have the parameters Download method, Server, Server port, Account, Username, FTP path, and HTTPS baser URL in common, they can be specified here. These settings will be used for a specific file type if its Use defaults parameter is set to "Yes".

If Use defaults is activated for a specific file type, any specific settings for this file type are overridden by the defaults.

>

  • Download method : Selects the protocol to be used. Value range: "FTP", "HTTPS". Default: "FTP".
  • Server address : IP address or hostname of the FTP/HTTPS server in use.
  • Server port : Port number of the FTP/HTTPS server in use. Default: 21.
  • FTP account : Account at the server (if applicable).
  • FTP username : User name for accessing the server.
  • FTP password : Password corresponding to the user name.
  • FTP path : Path of the directory containing the files.
  • HTTPS base URL : IP address or hostname of the HTTPS server in use; only applicable if Download method is switched to "HTTPS".

Data required

Page 122 of the Siemens 8000 user manual — 3.10 Transferring Phone Software, Application and Media Files
Seite 122 · Zum Vergrößern klicken
Seite 122

Transferring Phone Software, Application and Media Files

File transfer > Defaults

Siemens 8000 — 3.10 Transferring Phone Software, Application and Media Files diagram (page 122)
Abb. 90 · 3.10 Transferring Phone Software, Application and Me…

Administration via Local Phone

|--- Administration |--- File Transfer |--- Defaults |--- Download method |--- Server |--- Port |--- Account |--- Username |--- Password |--- FTP path |--- HTTPS base URL

Administration via WBM

Page 123 of the Siemens 8000 user manual — 3.10.3 Phone Software
Seite 123 · Zum Vergrößern klicken
Seite 123

Administration Transferring Phone Software, Application and Media Files

3.10.3 Phone Software

The firmware for the phone can be updated by downloading a new software file to the phone.

7 Do not disconnect the phone from the LAN or power unit during software update. An active update process is indicated by blinking LEDs and/or in the display.

3.10.3.1 FTP/HTTPS Access Data

If the default FTP/HTTPS Access settings (see Section 3.10.2, “Common FTP/HTTPS Set tings”) are to be used, Use default must be set to "Yes", and only the Filename must be spec ified.

Data required (in every case)

  • Use default : Specifies whether the default FTP/HTTPS access settings shall be used. Val ue range: "Yes", "No". Default: "No".
  • Filename : Specifies the file name of the phone software.

Data required (if not derived from Defaults)

  • Download method : Selects the protocol to be used. Value range: "FTP", "HTTPS". Default: "FTP".
  • Server address : IP address or hostname of the FTP/HTTPS server in use.
  • Server port : Port number of the FTP/HTTPS server in use. Default: 21.
  • FTP account : Account at the server (if applicable).
  • FTP username : User name for accessing the server.
  • FTP password : Password corresponding to the user name.
  • FTP path : Path of the directory containing the files.
  • HTTPS base URL : IP address or hostname of the HTTPS server in use; only applicable if Download method is switched to "HTTPS".
Page 124 of the Siemens 8000 user manual — 3.10.3 Phone Software
Seite 124 · Zum Vergrößern klicken
Seite 124

Transferring Phone Software, Application and Media Files

File transfer > Phone application

Siemens 8000 — 3.10.3 Phone Software diagram (page 124)
Abb. 91 · 3.10.3 Phone Software

Administration via Local Phone

|--- Administration |--- File Transfer |--- Phone app |--- Use default |--- Download method |--- Server |--- Port |--- Account |--- Username |--- Password |--- FTP path |--- HTTPS base URL |--- Filename

Administration via WBM

Page 125 of the Siemens 8000 user manual — 3.10.3.2 Download/Update Phone Software
Seite 125 · Zum Vergrößern klicken
Seite 125

Administration Transferring Phone Software, Application and Media Files

3.10.3.2 Download/Update Phone Software

If applicable, phone software should be deployed using the Deployment Service (DLS). Alter natively, the download can be triggered from the web interface or from the Local phone menu. When the download has been successful, the phone will restart and boot up using the new soft ware.

Start Download via WBM

Siemens 8000 — 3.10.3.2 Download/Update Phone Software diagram (page 125)
Abb. 92 · 3.10.3.2 Download/Update Phone Software

In the File transfer > Phone application dialog, set After submit to "start download" and press the Submit button.

Start Download via Local Phone

1. In the administration menu, set the focus to Phone app .

|--- Administration |--- File Transfer |--- Phone app

2. Press the g key. A context menu opens. In the context menu, select Download . The down load will start immediately.
Page 126 of the Siemens 8000 user manual — >
Seite 126 · Zum Vergrößern klicken
Seite 126

Transferring Phone Software, Application and Media Files

3.10.4 Music on Hold

If enabled by the user, the Music on Hold (MoH) sound file is played when a call is put on hold.

With V1R4.x upwards, the file size for a Music on Hold file is limited to 1MB. If the file is too large or the contents of the file are not valid, the file will not be stored in the phone.

>

  • The following formats for Music on Hold are supported:
  • Proprietary Music on Hold format for optiPoint 410/420 phones
  • WAV format. The recommended specifications are:
  • Audio format: PCM
  • Bitrate: 16 kB/sec
  • Sampling rate: 8 kHz
  • Quantization level: 16 bit.
  • MIDI format.
  • MP3 format (OpenStage 60/80 only). A bitrate of 48 kB/sec is recommended.

3.10.4.1 FTP/HTTPS Access Data

If the default FTP/HTTPS access settings (see Section 3.10.2, “Common FTP/HTTPS Set tings”) are to be used, Use Default must be set to "Yes", and only the Filename must be spec ified.

Data required (in every case)

  • Use default : Specifies whether the default FTP/HTTPS access settings shall be used. Val ue range: "Yes", "No". Default: "No".
  • Filename : Specifies the file name of the phone software.

Data required (if not derived from Defaults)

  • Download method : Selects the protocol to be used. Value range: "FTP", "HTTPS". Default: "FTP".
  • Server address : IP address or hostname of the FTP/HTTPS server in use.
  • Server port : Port number of the FTP/HTTPS server in use. Default: 21.
  • FTP account : Account at the server (if applicable).
  • FTP username : User name for accessing the server.
Page 127 of the Siemens 8000 user manual — 3.10.4 Music on Hold
Seite 127 · Zum Vergrößern klicken
Seite 127

Administration Transferring Phone Software, Application and Media Files

  • FTP password : Password corresponding to the user name.
  • FTP path : Path of the directory containing the files.
  • HTTPS base URL : IP address or hostname of the HTTPS server in use; only applicable if Download method is switched to "HTTPS".
Page 128 of the Siemens 8000 user manual — 3.10.4 Music on Hold
Seite 128 · Zum Vergrößern klicken
Seite 128

Transferring Phone Software, Application and Media Files

File transfer > Hold music

Siemens 8000 — 3.10.4 Music on Hold diagram (page 128)
Abb. 93 · 3.10.4 Music on Hold

Administration via Local Phone

|--- Administration |--- File Transfer |--- Hold Music |--- Use default |--- Download method |--- Server |--- Port |--- Account |--- Username |--- Password |--- FTP path |--- HTTPS base URL |--- Filename

Administration via WBM

Page 129 of the Siemens 8000 user manual — 3.10.4.2 Download Music on Hold
Seite 129 · Zum Vergrößern klicken
Seite 129

Administration Transferring Phone Software, Application and Media Files

3.10.4.2 Download Music on Hold

If applicable, Music on Hold should be deployed using the Deployment Service (DLS). Alterna tively, the download can be triggered from the web interface or from the local phone menu.

Start Download via WBM

In the File transfer > Hold music dialog, set After submit to "start download" and press the Submit button.

Start Download via Local Phone

1. In the administration menu, set the focus to Hold Music .

|--- Administration |--- File Transfer |--- Hold Music

2. Press the g key. A context menu opens. In the context menu, select Download . The down load will start immediately.
Page 130 of the Siemens 8000 user manual — >
Seite 130 · Zum Vergrößern klicken
Seite 130

Transferring Phone Software, Application and Media Files

3.10.5 Picture Clips

>

Picture clips are available only on OpenStage 60/80 phones.

>

With V1R4.x upwards, the file size for a picture clip is limited to 300 KB. If the file is too large or the contents of the file are not valid, the file will not be stored in the pho ne.

Picture Clips are small images used for displaying a picture of a person that is calling on a line. The supported file formats for picture clips are JPEG and PNG (recommended).

3.10.5.1 FTP/HTTPS Access Data

If the default FTP/HTTPS access settings (see Section 3.10.2, “Common FTP/HTTPS Set tings”) are to be used, Use default must be set to "Yes", and only the Filename must be spec ified.

Data required (in every case)

  • Use default : Specifies whether the default FTP/HTTPS access settings shall be used. Val ue range: "Yes", "No". Default: "No".
  • Filename : Specifies the file name of the phone software.

Data required (if not derived from Defaults)

  • Download method : Selects the protocol to be used. Value range: "FTP", "HTTPS". Default: "FTP".
  • Server address : IP address or hostname of the FTP/HTTPS server in use.
  • Server port : Port number of the FTP/HTTPS server in use. Default: 21.
  • FTP account : Account at the server (if applicable).
  • FTP username : User name for accessing the server.
  • FTP password : Password corresponding to the user name.
  • FTP path : Path of the directory containing the files.
  • HTTPS base URL : IP address or hostname of the HTTPS server in use; only applicable if Download method is switched to "HTTPS".
Page 131 of the Siemens 8000 user manual — 3.10.5 Picture Clips
Seite 131 · Zum Vergrößern klicken
Seite 131

Administration Transferring Phone Software, Application and Media Files

File transfer > Picture clip

Siemens 8000 — 3.10.5 Picture Clips diagram (page 131)
Abb. 94 · 3.10.5 Picture Clips

Administration via Local Phone

|--- Administration |--- File Transfer |--- Picture Clip |--- Use default |--- Download method |--- Server |--- Port |--- Account |--- Username |--- Password |--- FTP path |--- HTTPS base URL |--- Filename

Administration via WBM

Page 132 of the Siemens 8000 user manual — 3.10.5.2 Download Picture Clip
Seite 132 · Zum Vergrößern klicken
Seite 132

Transferring Phone Software, Application and Media Files

3.10.5.2 Download Picture Clip

If applicable, picture clips should be deployed using the Deployment Service (DLS). Alterna tively, the download can be triggered from the web interface or from the local phone menu.

Start Download via WBM

In the File transfer > Picture clip dialog, set After submit to "start download" and press the Submit button.

Start Download via Local Phone

1. In the administration menu, set the focus to Picture clip .

|--- Administration |--- File Transfer |--- Picture clip

2. Press the g key. A context menu opens. In the context menu, select Download . The down load will start immediately.
Page 133 of the Siemens 8000 user manual — >
Seite 133 · Zum Vergrößern klicken
Seite 133

Administration Transferring Phone Software, Application and Media Files

3.10.6 LDAP Template

>

LDAP is available only on OpenStage 60/80 phones.

The LDAP template is an ASCII text file that uses an allocation list to assign directory server attributes to input and output fields on an LDAP client. The LDAP template must be modified correctly for successful communication between the directory server and the LDAP client.

>

The OpenStage phone supports LDAPv3.

3.10.6.1 FTP/HTTPS Access Data

If the default FTP/HTTPS access settings (see Section 3.10.2, “Common FTP/HTTPS Set tings”) are to be used, Use default must be set to "Yes", and only the Filename must be spec ified.

Data required (in every case)

  • Use default : Specifies whether the default FTP/HTTPS access settings shall be used. Val ue range: "Yes", "No". Default: "No".
  • Filename : Specifies the file name of the phone software.

Data required (if not derived from Defaults)

  • Download method : Selects the protocol to be used. Value range: "FTP", "HTTPS". Default: "FTP".
  • Server address : IP address or hostname of the FTP/HTTPS server in use.
  • Server port : Port number of the FTP/HTTPS server in use. Default: 21.
  • FTP account : Account at the server (if applicable).
  • FTP username : User name for accessing the server.
  • FTP password : Password corresponding to the user name.
  • FTP path : Path of the directory containing the files.
  • HTTPS base URL : IP address or hostname of the HTTPS server in use; only applicable if Download method is switched to "HTTPS".
Page 134 of the Siemens 8000 user manual — 3.10.6 LDAP Template
Seite 134 · Zum Vergrößern klicken
Seite 134

Transferring Phone Software, Application and Media Files

File transfer > LDAP

Siemens 8000 — 3.10.6 LDAP Template diagram (page 134)
Abb. 95 · 3.10.6 LDAP Template

Administration via Local Phone

|--- Administration |--- File Transfer |--- LDAP |--- Use default |--- Download method |--- Server |--- Port |--- Account |--- Username |--- Password |--- FTP path |--- HTTPS base URL |--- Filename

Administration via WBM

Page 135 of the Siemens 8000 user manual — >
Seite 135 · Zum Vergrößern klicken
Seite 135

Administration Transferring Phone Software, Application and Media Files

3.10.6.2 Download LDAP Template

If applicable, LDAP templates should be deployed using the Deployment Service (DLS). Alter natively, the download can be triggered from the web interface or from the local phone menu.

>

The OpenStage phone supports LDAPv3.

Start Download via WBM

In the File transfer > LDAP dialog, set After submit to "start download" and press the Submit button.

Start Download via Local Phone

1. In the administration menu, set the focus to LDAP .

|--- Administration |--- File Transfer |--- LDAP

2. Press the g key. A context menu opens. In the context menu, select Download . The down load will start immediately.
Page 136 of the Siemens 8000 user manual — 3.10.7 Logo
Seite 136 · Zum Vergrößern klicken
Seite 136

Transferring Phone Software, Application and Media Files

3.10.7 Logo

On OpenStage 40/60/80, a custom background image for the telephony interface can be sup plied. In most cases, this will be the company logo.

  • On OpenStage 40, monochrome bitmap files (BMP) are supported. The ideal size is as follows:
  • Width: 144 px
  • Height: 32 px

On OpenStage 60/80, the supported file formats are JPEG and PNG. The ideal size values are is as follows:

  • OpenStage 60:
  • Width: 240 px
  • Height: 70 px
  • OpenStage 80:
  • Width: 480 px
  • Height: 148 px

If the size should deviate from these values, the image will appear skewed.

For guidance on creating a logo file for OpenStage 40/60/80, see Section 4.2, “How to Create Logo Files for OpenStage Phones”.

3.10.7.1 FTP/HTTPS Access Data

If the default FTP/HTTPS access settings (see Section 3.10.2, “Common FTP/HTTPS Set tings”) are to be used, Use default must be set to "Yes", and only the Filename must be spec ified.

Data required (in every case)

  • Use default : Specifies whether the default FTP/HTTPS access settings shall be used. Val ue range: "Yes", "No". Default: "No".
  • Filename : Specifies the file name of the phone software.
Page 137 of the Siemens 8000 user manual — 3.10.7 Logo
Seite 137 · Zum Vergrößern klicken
Seite 137

Administration Transferring Phone Software, Application and Media Files

Data required (if not derived from Defaults)

  • Download method : Selects the protocol to be used. Value range: "FTP", "HTTPS". Default: "FTP".
  • Server address : IP address or hostname of the FTP/HTTPS server in use.
  • Server port : Port number of the FTP/HTTPS server in use. Default: 21.
  • FTP account : Account at the server (if applicable).
  • FTP username : User name for accessing the server.
  • FTP password : Password corresponding to the user name.
  • FTP path : Path of the directory containing the files.
  • HTTPS base URL : IP address or hostname of the HTTPS server in use; only applicable if Download method is switched to "HTTPS".

File transfer > Logo

Siemens 8000 — 3.10.7 Logo diagram (page 137)
Abb. 96 · 3.10.7 Logo

Administration via Local Phone

|--- Administration |--- File Transfer |--- Logo |--- Use default |--- Download method |--- Server |--- Port |--- Account |--- Username |--- Password |--- FTP path |--- HTTPS base URL |--- Filename

Administration via WBM

Page 138 of the Siemens 8000 user manual — 3.10.7.2 Download Logo
Seite 138 · Zum Vergrößern klicken
Seite 138

Transferring Phone Software, Application and Media Files

3.10.7.2 Download Logo

If applicable, logos should be deployed using the Deployment Service (DLS). Alternatively, the download can be triggered from the web interface or from the local phone menu.

Start Download via WBM

In the File transfer > Logo dialog, set After submit to "start download" and press the Submit button.

Start Download via Local Phone

1. In the administration menu, set the focus to Logo .

|--- Administration |--- File Transfer |--- Logo

2. Press the g key. A context menu opens. In the context menu, select Download . The down load will start immediately.
Page 139 of the Siemens 8000 user manual — >
Seite 139 · Zum Vergrößern klicken
Seite 139

Administration Transferring Phone Software, Application and Media Files

3.10.8 Screensaver

The screensaver is displayed when the phone is in idle mode. It performs a slide show consist ing of images which can be uploaded using the web interface.

>

Screensavers are available only on OpenStage 60/80 phones.

With V1R4.x upwards, the file size for a screensaver image is limited to 300 KB. If the file is too large or the contents of the file are not valid, the file will not be stored in the phone.

>

  • For screensaver images, the following specifications are valid:
  • Data format: JPG or PNG. JPG is recommended.
  • Screen format: 4:3. The images are resized to fit in the screen, so that images with a width/ height ratio differing from 4:3 will appear with deviant proportions.
  • Resolution: The phone’s screen resolution is the best choice for image resolution:
  • OpenStage 60: 320x240
  • OpenStage 80: 640x480

3.10.8.1 FTP/HTTPS Access Data

If the default FTP/HTTPS access settings (see Section 3.10.2, “Common FTP/HTTPS Set tings”) are to be used, Use default must be set to "Yes", and only the Filename must be spec ified.

Data required (in every case)

  • Use default : Specifies whether the default FTP/HTTPS access settings shall be used. Val ue range: "Yes", "No". Default: "No".
  • Filename : Specifies the file name of the phone software.

Data required (if not derived from Defaults)

  • Download method : Selects the protocol to be used. Value range: "FTP", "HTTPS". Default: "FTP".
  • Server address : IP address or hostname of the FTP/HTTPS server in use.
  • Server port : Port number of the FTP/HTTPS server in use. Default: 21.
  • FTP account : Account at the server (if applicable).
Page 140 of the Siemens 8000 user manual — 3.10.8 Screensaver
Seite 140 · Zum Vergrößern klicken
Seite 140

Transferring Phone Software, Application and Media Files

  • FTP username : User name for accessing the server.
  • FTP password : Password corresponding to the user name.
  • FTP path : Path of the directory containing the files.
  • HTTPS base URL : IP address or hostname of the HTTPS server in use; only applicable if Download method is switched to "HTTPS".

File transfer > Screensaver

Siemens 8000 — 3.10.8 Screensaver diagram (page 140)
Abb. 97 · 3.10.8 Screensaver

Administration via Local Phone

|--- Administration |--- File Transfer |--- Screensaver |--- Use default |--- Download method |--- Server |--- Port |--- Account |--- Username |--- Password |--- FTP path |--- HTTPS base URL |--- Filename

Administration via WBM

Page 141 of the Siemens 8000 user manual — 3.10.8.2 Download Screensaver
Seite 141 · Zum Vergrößern klicken
Seite 141

Administration Transferring Phone Software, Application and Media Files

3.10.8.2 Download Screensaver

If applicable, screensavers should be deployed using the Deployment Service (DLS). Alterna tively, the download can be triggered from the web interface or from the local phone menu.

Start Download via WBM

In the File transfer > Screensaver dialog, set After submit to "start download" and press the Submit button.

Start Download via Local Phone

1. In the administration menu, set the focus to Screensaver .

|--- Administration |--- File Transfer |--- Screensaver

2. Press the g key. A context menu opens. In the context menu, select Download . The down load will start immediately.
Page 142 of the Siemens 8000 user manual — >
Seite 142 · Zum Vergrößern klicken
Seite 142

Transferring Phone Software, Application and Media Files

3.10.9 Ringer File

Custom Ringtones can be uploaded to the phone.

With V1R4.x upwards, the file size for a ringer file is limited to 1 MB. IIf the file is too large or the contents of the file are not valid, the file will not be stored in the phone.

>

The following file formats are supported: • WAV format. The recommended specifications are:

  • Audio format: PCM
  • Bitrate: 16 kB/sec
  • Sampling rate: 8 kHz
  • Quantization level: 16 bit
  • MIDI format.
  • MP3 format (OpenStage 60/80 only). The OpenStage 60/80 phones are able to play MP3 files from 32 kbit/s up to 320 kbit/s. As the memory for user data is limited to 8 MB, a con stant bitrate of 48 kbit/sec to 112 kbit/s and a length of max. 1 minute is recommended. Although the phone software can play stereo files, mono files are recommended, as the phone has only 1 loudspeaker. See the following table for estimated file size (mono files):

Length 64 kbit/s 80 kbit/s 96 kbit/s 112 kbit/s

0:15 min 0,12 MB 0,15 MB 0,18 MB 0,21 MB

0:30 min 0,23 MB 0,29 MB 0,35 MB 0,41 MB

0:45 min 0,35 MB 0,44 MB 0,53 MB 0,62 MB

1:00 min 0,47 MB 0,59 MB 0,70 MB 0,82 MB

3.10.9.1 FTP/HTTPS Access Data

If the default FTP/HTTPS access settings (see Section 3.10.2, “Common FTP/HTTPS Set tings”) are to be used, Use default must be set to "Yes", and only the Filename must be spec ified.

Tabelle 3-2

Page 143 of the Siemens 8000 user manual — 3.10.9 Ringer File
Seite 143 · Zum Vergrößern klicken
Seite 143

Administration Transferring Phone Software, Application and Media Files

Data required (in every case)

  • Use default : Specifies whether the default FTP/HTTPS access settings shall be used. Val ue range: "Yes", "No". Default: "No".
  • Filename : Specifies the file name of the phone software.

Data required (if not derived from Defaults)

  • Download method : Selects the protocol to be used. Value range: "FTP", "HTTPS". Default: "FTP".
  • Server address : IP address or hostname of the FTP/HTTPS server in use.
  • Server port : Port number of the FTP/HTTPS server in use. Default: 21.
  • FTP account : Account at the server (if applicable).
  • FTP username : User name for accessing the server.
  • FTP password : Password corresponding to the user name.
  • FTP path : Path of the directory containing the files.
  • HTTPS base URL : IP address or hostname of the HTTPS server in use; only applicable if Download method is switched to "HTTPS".

File transfer > Ringer file

Siemens 8000 — 3.10.9 Ringer File diagram (page 143)
Abb. 98 · 3.10.9 Ringer File

Administration via Local Phone

|--- Administration |--- File Transfer |--- Ringer |--- Use default |--- Download method

Administration via WBM

Page 144 of the Siemens 8000 user manual — 3.10.9 Ringer File
Seite 144 · Zum Vergrößern klicken
Seite 144

Transferring Phone Software, Application and Media Files

|--- Server |--- Port |--- Account |--- Username |--- Password |--- FTP path |--- HTTPS base URL |--- Filename

Page 145 of the Siemens 8000 user manual — 3.10.9.2 Download Ringer File
Seite 145 · Zum Vergrößern klicken
Seite 145

Administration Transferring Phone Software, Application and Media Files

3.10.9.2 Download Ringer File

If applicable, ringtone files should be deployed using the Deployment Service (DLS). Alterna tively, the download can be triggered from the web interface or from the local phone menu.

Start Download via WBM

In the File transfer > Ringer dialog, set After submit to "start download" and press the Submit button.

Start Download via Local Phone

1. In the administration menu, set the focus to Ringer .

|--- Administration |--- File Transfer |--- Ringer

2. Press the g key. A context menu opens. In the context menu, select Download . The down load will start immediately.
Page 146 of the Siemens 8000 user manual — >
Seite 146 · Zum Vergrößern klicken
Seite 146
Corporate PhonebookDirectory Settings

3.11 Corporate Phonebook: Directory Settings

3.11.1 LDAP

>

LDAP is available only on OpenStage 60/80 phones.

The Lightweight Directory Access Protocol enables access to a directory server via an LDAP client. Various personal information is stored there, e.g. the name, organisation and contact data of persons working in an organisation. When the LDAP client has found a person’s data, e. g. by looking up the surname, the user can call this person directly using the displayed num ber.

>

The OpenStage phone supports LDAPv3.

For connecting the phone’s LDAP client to a LDAP server, the required access data must be configured. The parameters Server address and Server port specify the IP address and host name as well as the port used by the LDAP server. If the Authentication is not set to "Anony mous", the user must authenticate himself with the server by providing an User name and a corresponding Password.

  • Server address : IP address or hostname of the LDAP server.
  • Server port : Port on which the LDAP server is listening for requests. Default: 389.
  • Authentication : Authentication method used for connecting to the LDAP server. value range: "Anonymous", "Simple". Default: "Anonymous".
  • User name : User name used for authentication with the LDAP server.
  • Password : Password used for authentication with the LDAP server.

Data required

Page 147 of the Siemens 8000 user manual — 3.11 Corporate Phonebook: Directory Settings
Seite 147 · Zum Vergrößern klicken
Seite 147
Administration Corporate PhonebookDirectory Settings

Local Functions > Directory settings

Siemens 8000 — 3.11 Corporate Phonebook: Directory Settings diagram (page 147)
Abb. 99 · 3.11 Corporate Phonebook: Directory Settings

Administration via Local Phone

|--- Administration |--- Local Functions |--- Directory Settings |--- LDAP server address |--- LDAP server port |--- LDAP authentication |--- LDAP user name |--- LDAP password

Administration via WBM

Page 148 of the Siemens 8000 user manual — 3.12 Speech
Seite 148 · Zum Vergrößern klicken
Seite 148

3.12 Speech

3.12.1 RTP Base Port

This parameter sets the port to be used for speech data, which is transmitted by RTP (Real- Time Transport Protocol). The default port number is 5010.

Network > Port Configuration

Siemens 8000 — 3.12 Speech diagram (page 148)
Abb. 100 · 3.12 Speech

Administration via Local Phone

|--- Administration |--- Network |--- Port Configuration |--- RTP base

Speech · Administration via WBM

Page 149 of the Siemens 8000 user manual — 3.12.2 Codec Preferences
Seite 149 · Zum Vergrößern klicken
Seite 149

3.12.2 Codec Preferences

If Silence suppression is activated, the transmission of data packets is suppressed on no con versation, that is, if the user doesn’t speak.

The OpenStage phone provides the codecs G.711, G.722, and G.729. When a SIP connection is established between two endpoints, the phones negotiate the codec to be used. The result of the negotiation is based on the general availability and ranking assigned to each codec. The administrator can allow or disallow a codec as well as assign a ranking number to it.

The Packet size, i. e. length in milliseconds, of the RTP packets for speech data, can be set to 10ms or 20ms or to automatic detection.

  • Data required
  • Silence suppression : Suppression of data transmission on no conversation. Value range: "On", "Off". Default: "Off".
  • Packet size : Size of RTP packets in milliseconds. Value range: "10 ms", "20ms", "Automatic". Default: "Automatic".
  • G.711 : Parameters for the G. 711 codec. Value Range: "Choice 1", "Choice 2", "Choice 3", "Disabled", "Enabled". Default: "Choice 1".
  • G.729 : Parameters for the G. 729 codec. Value Range: "Choice 1", "Choice 2", "Choice 3", "Disabled", "Enabled". Default: "Choice 2".
  • G.722 : Parameters for the G. 722 codec. Value Range: "Choice 1", "Choice 2", "Choice 3", "Disabled", "Enabled". Default: "Disabled".

Speech > Codec preferences

Siemens 8000 — 3.12.2 Codec Preferences diagram (page 149)
Abb. 101 · 3.12.2 Codec Preferences

Speech · Administration via WBM

Page 150 of the Siemens 8000 user manual — 3.12.2 Codec Preferences
Seite 150 · Zum Vergrößern klicken
Seite 150

Administration via Local Phone

|--- Administration |--- Speech |--- Codec Preferences |--- Silence suppression |--- Packet size |--- G.711 |--- G.729 |--- G.722

Speech

Page 151 of the Siemens 8000 user manual — 3.12.3 Audio Settings
Seite 151 · Zum Vergrößern klicken
Seite 151

3.12.3 Audio Settings

The usage of microphone and speaker for speakerphone mode can be controlled by the ad ministrator.

Both microphone and loudspeaker can be switched on or off separately. By default, both micro phone and loudspeaker are switched on.

Speech > Audio Settings

Siemens 8000 — 3.12.3 Audio Settings diagram (page 151)
Abb. 102 · 3.12.3 Audio Settings

Administration via Local Phone

|--- Administration |--- Speech |--- Audio Settings |--- Disable microphone |--- Disable loudspeech

Speech · Administration via WBM

Page 152 of the Siemens 8000 user manual — 3.13 Applications
Seite 152 · Zum Vergrößern klicken
Seite 152

3.13 Applications

3.13.1 XML Applications (OpenStage 60/80 with V1R3.x upwards)

3.13.1.1 Basic Setup/Configuration

The XML interface enables server-based applications with a set of GUI elements. The techno logies commonly used in web applications can be used: Java Servlets, JSP, PHP, CGI etc., de livered by servers such as Tomcat, Apache, Microsoft IIS.

Xpressions is a special Unified Communications application which also uses the XML interface.

To set up a new XML application, enter the access data for the application on the server:

The Display name can be defined freely. This name will appear in the applications tab once the application is configured, and it will appear in a newy created tab when the application is running. With Xpressions, this value is predefined as "Xpressions".

The Application name is used by the phone software to identify the XML application running on the phone. With Xpressions, this value is predefined as "Xpressions".

The Protocol for exchanging XML data with the server-side program can be set to "HTTP" or "HTTPS".

The Server address is the IP address or domain name of the server which hosts the remote program. Server port number specifies the corresponding port.

Program name specifies the relative path to the servlet or to the first XML page of the applica tion on the server. The relative path refers to the root directory for documents on the web serv er. The program name cannot be longer than 100 characters.

XML trace enabled determines whether debugging information is sent to a special debugging program on the remote server. The relative path for the debugging program is given by the De bug program name parameter.

Applications

Page 153 of the Siemens 8000 user manual — 3.13 Applications
Seite 153 · Zum Vergrößern klicken
Seite 153
  • Display name : Program name to be displayed on the phone. Value specifications:
  • It must be unique on the phone.
  • It cannot contain the ’^’ character.
  • It cannot not be empty.
  • Its length cannot not exceed 20 characters.
  • Application name : Used internally to identify the XML application running on the phone. Value specifications:
  • It must be unique on the phone.
  • It cannot contain non-alphanumeric characters, spaces for instance.
  • The first character must be a letter.
  • It must not be empty.
  • Its length must not exceed 20 characters.
  • Protocol : Communication protocol for the data exchange with the server. Value range: "HTTP", "HTTPS". Default: "HTTPS".
  • Server address : IP address or domain/host name of the server that provides the applica tion or the XML document.
  • Server port number : Number of the port that the server uses to provide the application or XML document.
  • Program name : Relative path to the servlet or to the first XML page of the application on the server.
  • XML trace enabled : Enables or Disables the debugging of the XML application. Value range: "Yes", "No". Default: "No".
  • Debug program name : The relative path to a special servlet that receives the debug in formation.

Applications · Data required

Page 154 of the Siemens 8000 user manual — 3.13 Applications
Seite 154 · Zum Vergrößern klicken
Seite 154

Applications > XML Applications > Add application

Siemens 8000 — 3.13 Applications diagram (page 154)
Abb. 103 · 3.13 Applications

Applications > XML Applications > Modify application

Siemens 8000 — 3.13 Applications diagram (page 154)
Abb. 104 · 3.13 Applications

Applications · Administration via WBM

Page 155 of the Siemens 8000 user manual — 3.13.1.2 HTTP Proxy
Seite 155 · Zum Vergrößern klicken
Seite 155

Administration via Local Phone

|--- Administration |--- Applications |--- XML |--- Add application |--- Display name |--- Application name |--- Server address |--- Server port |--- Protocol |--- Program name |--- XML trace enabled |--- Debug program name

3.13.1.2 HTTP Proxy

The HTTP data transfer between the phone and the server on which the remote program is run ning can be handled be an HTTP proxy, if desired.

First, the proxy itself must be configured. Enter the IP address of the proxy it in the Network > IP configuration > HTTP proxy parameter, and the corresponding port in the Network > Port configuration > HTTP proxy parameter.

Use proxy enables or disables the use of the proxy. If disabled, the phones connects directly to the server. By default, the use of a proxy is disabled.

Applications > XML Applications > Add application

Siemens 8000 — 3.13.1.2 HTTP Proxy diagram (page 155)
Abb. 105 · 3.13.1.2 HTTP Proxy

Applications · Administration via WBM

Page 156 of the Siemens 8000 user manual — 3.13.1.2 HTTP Proxy
Seite 156 · Zum Vergrößern klicken
Seite 156

Applications > XML Applications > Modify application

Siemens 8000 — 3.13.1.2 HTTP Proxy diagram (page 156)
Abb. 106 · 3.13.1.2 HTTP Proxy

Network > IP Configuration

Siemens 8000 — 3.13.1.2 HTTP Proxy diagram (page 156)
Abb. 107 · 3.13.1.2 HTTP Proxy

Applications

Page 157 of the Siemens 8000 user manual — 3.13.1.3 Modify an Existing Application
Seite 157 · Zum Vergrößern klicken
Seite 157

Administration via Local Phone

|--- Administration |--- Applications |--- XML |--- Add application | |--- Use proxy |--- Add Xpressions |--- Use proxy

|--- Administration |--- Network |--- IP Configuration |--- HTTP proxy

|--- Administration |--- Network |--- Port configuration |--- HTTP proxy

3.13.1.3 Modify an Existing Application

An existing application can be modified by changing its parameters. Please ensure to select the desired application before changing the parameters.

Applications > XML applications > Modify application

Siemens 8000 — 3.13.1.3 Modify an Existing Application diagram (page 157)
Abb. 108 · 3.13.1.3 Modify an Existing Application

Applications · Administration via WBM

Page 158 of the Siemens 8000 user manual — 3.13.1.4 Remove an Existing Application
Seite 158 · Zum Vergrößern klicken
Seite 158

Administration via Local Phone

|--- Administration |--- Applications |--- XML |--- |--- Display name |--- Application name |--- Server address |--- Server port |--- Protocol |--- Program name |--- XML trace enabled |--- Debug program name

3.13.1.4 Remove an Existing Application

An existing application can be removed. Please ensure to select the desired application before changing the parameters.

Applications > XML applications > Modify application

Siemens 8000 — 3.13.1.4 Remove an Existing Application diagram (page 158)
Abb. 109 · 3.13.1.4 Remove an Existing Application

Applications · Administration via WBM

Page 159 of the Siemens 8000 user manual — 3.13.1.4 Remove an Existing Application
Seite 159 · Zum Vergrößern klicken
Seite 159

Administration via Local Phone

|--- Administration |--- Applications |--- XML |--- |--- Display name |--- Application name |--- Server address |--- Server port |--- Protocol |--- Program name |--- XML trace enabled |--- Debug program name

Applications

Page 160 of the Siemens 8000 user manual — 3.14 Password
Seite 160 · Zum Vergrößern klicken
Seite 160

3.14 Password

The passwords for user and administrator can be set here. They have to be confirmed after en tering. The factory setting is "123456"; it should be changed after the first login.

Authentication > Change Admin password

Siemens 8000 — 3.14 Password diagram (page 160)
Abb. 110 · 3.14 Password

Authentication > Change User password

Siemens 8000 — 3.14 Password diagram (page 160)
Abb. 111 · 3.14 Password

Administration via Local Phone

|--- Administration |--- Password |--- Admin |--- Confirmation |--- User |--- Confirmation

Password · Administration via WBM

Page 161 of the Siemens 8000 user manual — 3.15 Troubleshooting: Lost Password
Seite 161 · Zum Vergrößern klicken
Seite 161
Administration TroubleshootingLost Password

3.15 Troubleshooting: Lost Password

If the administration and/or user password is lost, and there is no DLS available, new passwords must be provided. For this purpose, a factory reset is necessary. Take the following steps to initiate a factory reset:

1. On the phone, press the v key to activate the administration menu (the v key toggles be tween the user’s configuration menu and the administration menu).
2. Press the number keys 2-8-9 simultaneously. The factory reset menu opens.
3. In the input field, enter the special password for factory reset: "124816".
4. Confirm by pressing i .
Page 162 of the Siemens 8000 user manual — 3.16 Factory Reset
Seite 162 · Zum Vergrößern klicken
Seite 162

3.16 Factory Reset

This function resets all parameters to their factory settings. A special reset password is required for this operation: "124816".

Maintenance > Factory reset

Siemens 8000 — 3.16 Factory Reset diagram (page 162)
Abb. 112 · 3.16 Factory Reset

Administration via Local Phone

|--- Administration |--- Maintenance |--- Factory reset

Factory Reset · Administration via WBM

Page 163 of the Siemens 8000 user manual — 3.17 Diagnostics
Seite 163 · Zum Vergrößern klicken
Seite 163

3.17 Diagnostics

3.17.1 Display General Phone Information

General information about the status of the phone can be displayed if desired.

  • MAC address : Shows the phone’s MAC address.
  • Software version : Displays the version of the phone’s firmware.
  • Last restart : Shows date and time of the last reboot.

Display on the WBM

Siemens 8000 — 3.17 Diagnostics diagram (page 163)
Abb. 113 · 3.17 Diagnostics

Display on the Local Phone

|--- Administration |--- General Information |--- MAC address |--- Software version |--- Last restart

Diagnostics · Displayed Data · General information

Page 164 of the Siemens 8000 user manual — 3.17.2 LAN Monitoring
Seite 164 · Zum Vergrößern klicken
Seite 164

3.17.2 LAN Monitoring

The LAN port mirror facility allows for monitoring all network traffic at the phone’s LAN port. For further information, see Section 3.2.1, “LAN Port Settings”.

Additionally, there is a possibility to monitor LAN traffic and port settings in the Local user menu:

|--- User |--- Network information |--- IP address |--- WBM URL |--- DNS domain |--- LAN RX |--- LAN TX |--- PC RX |--- PC TX |--- LAN autonegotiated |--- LAN information |--- PC autonegotiated |--- PC information

Diagnostics

Page 165 of the Siemens 8000 user manual — 3.17.3 IP Tests
Seite 165 · Zum Vergrößern klicken
Seite 165

3.17.3 IP Tests

For network diagnostics, the OpenStage phone can ping any host or network device to deter mine whether it is reachable. Additionally, the IP route to a host or network device can be traced using the traceroute tool contained in the phone software.

The Pre Defined Ping tests provide pinging for a pre-defined selection of servers: DLS, SIP server, and SIP registrar.

Ping tests enables the pinging of a random IP address.

The Pre Defined Trace tests provide traceroute tests for a pre-defined selection of servers: DLS, SIP server, and SIP registrar.

Traceroute enables traceroute tests for a random IP address.

Diagnostics > Miscellaneous > IP tests

Siemens 8000 — 3.17.3 IP Tests diagram (page 165)
Abb. 114 · 3.17.3 IP Tests

Diagnostics · Administration via WBM

Page 166 of the Siemens 8000 user manual — 3.17.4 Process and Memory Information
Seite 166 · Zum Vergrößern klicken
Seite 166

3.17.4 Process and Memory Information

The processes currently running on the phone’s operating system as well as their CPU and memory usage can be monitored here. 100 processes are displayed on the web page. For fur ther information, please refer to the documentation of the "top" command for Unix/Linux sys tems.

Diagnostics > Miscellaneous > Memory information

Siemens 8000 — 3.17.4 Process and Memory Information diagram (page 166)
Abb. 115 · 3.17.4 Process and Memory Information

Diagnostics · Administration via WBM

Page 167 of the Siemens 8000 user manual — 3.17.5 Fault Trace Configuration
Seite 167 · Zum Vergrößern klicken
Seite 167

3.17.5 Fault Trace Configuration

Error tracing and logging can be configured separately for all components, i. e. the services and applications running on the OpenStage phone. The resulting files can be viewed in the WBM web pages over the Download links.

The File size (bytes) parameter sets the maximum file size. When the maximum size is reached, the file is deleted, and a new file is generated. The trace data is then written to the new file. The default value is 65536.

The Trace timeout (minutes) determines when to stop tracing, i. e. writing to the trace file.

If Automatic clear before start is checked, the existing trace file will be deleted on pressing the Submit button, and a new, empty trace file will be generated. By default, it is unchecked.

  • You can read the log files by clicking on the appropriate hyperlinks (the hyperlinks work only if the file in question has been created). The following logs can be viewed:
  • Download trace file The trace data according to the settings specified for the services.
  • Download boot file The system messages of the booting process.
  • Download saved trace file Normally, the trace file is saved only in the phone RAM. When the phone restarts in a con trolled manner, the trace file will be saved in permanent memory.
  • Download saved boot file Normally, the boot file is saved only in the phone RAM. When the phone restarts in a con trolled manner, the boot file will be saved in permanent memory..
  • Download upgrade trace file The trace log created during a software upgrade.
  • Download upgrade error file The error messages created during a software upgrade.
  • Download exception file If an exceptions occurs in a process running on the phone, a message is written to this file.
  • Download old exception file The exception file is stored permanent memory. When the file has reached its size limit, it will be saved as old exception file, and the current exception file is emptied for future mes sages. The old exception file can be viewed here.
  • Download old trace file The trace file is stored permanent memory. When the file has reached its size limit, it will be saved as old trace file, and the current exception file is emptied for future messages. The old trace file can be viewed here.
  • Download error file

Diagnostics

Page 168 of the Siemens 8000 user manual — 3.17.5 Fault Trace Configuration
Seite 168 · Zum Vergrößern klicken
Seite 168
  • Download syslog file

By pressing Submit, the trace settings are submitted to the phone. With Reset, the recent changes can be canceled.

  • The following trace levels can be selected:
  • OFF : Default value. Only error messages are stored.
  • ERROR : Error messages are stored.
  • TRACE : Trace messages are stored. These contain detailed information about the pro cesses taking place in the phone.
  • DEBUG : All types of messages are stored.

Brief Descriptions of the Components/Services

  • Administration Deals with the changing and setting of parameters within the phone database, from both the User and Admin menus.
  • Application framework All applications within the phone, e.g. Call view, Call log or Phonebook, are run within the application framework. It is responsible for the switching between different applications and bringing them into and out of focus as appropriate.
  • Application menu This is where applications to be run on the phone can be started and stopped.
  • Bluetooth service Handles the Bluetooth interactions between external Bluetooth devices and the phone. Bluetooth is available only on OpenStage 60/80 phones.
  • Call log The Call log application displays the call history of the phone.
  • Call view Handles the representation of telephony calls on the phone screen.
  • Certificate management Handles the verification and exchange of certificates for security and verification purposes.
  • Communications Involved in the passing of call related information and signaling to and from the CSTA ser vice.
  • Component registrar Handles data relating to the type of phone, e.g. OpenStage 20/40 HFA/SIP, OpenStage 60/ 80 HFA/SIP.
  • CSTA service

Diagnostics

Page 169 of the Siemens 8000 user manual — 3.17.5 Fault Trace Configuration
Seite 169 · Zum Vergrößern klicken
Seite 169
  • Any CSTA messages are handled by this service. CSTA messages are used within the phone by all services as a common call progression and control protocol.
  • Data Access service Allows other services to access the data held within the phone database.
  • Desktop Responsible for the shared parts of the phone display. Primarily these are the status bar at the top of the screen and the FPK labels.
  • Digit analysis service Analyses and modifies digit streams which are sent to and received by the phone, e.g. ca nonical conversion.
  • Directory service Performs a look up for data in the phonebook, trying to match incoming and outgoing num bers with entries in the phonebook.
  • DLS client management Handles interactions with the DLS (Deployment Service).
  • Health service Monitors other components of the phone for diagnostic purposes and provides a logging interface for the services in the phone.
  • Help Handles the help function.
  • Instrumentation service Used by the Husim phone tester to exchange data with the phone for remote control, test ing and monitoring purposes.
  • Java Any Java applications running on the phone will be run in the Java sandbox controlled by the Java service.
  • Journal service Responsible for saving and retrieving call history information, which is used by the Call log application.
  • Media control service Provides the control of media streams (voice, tones, ringing etc. ) within the phone.
  • Media processing service This is a layer of software between the media control service, the tone generation, and voice engine services. It is also involved in the switching of audio devices such as the hand set and loudspeaker.
  • Mobility service Handles the mobility feature whereby users can log onto different phones and have them configured to their own profile.
  • OBEX service Involved with Bluetooth accesses to the phone.

Diagnostics

Page 170 of the Siemens 8000 user manual — >
Seite 170 · Zum Vergrößern klicken
Seite 170
  • Bluetooth is available only on OpenStage 60/80 phones.
  • Openstage client management Provides a means by which other services within the phone can interact with the database.
  • Phonebook Responsible for the phonebook application.
  • POT service Takes over control of basic telephony if the callview application fails.
  • Password management service Verifies passwords used in the phone.
  • Physical interface service Handles any interactions with the phone via the keypad, mode keys, fixed feature buttons, clickwheel and slider.
  • Service framework This is the environment within which other phone services operate. It is involved in the starting and stopping of services.
  • Service registry Keeps a record of all services currently running inside the phone.
  • SIP call control Contains the call model for the phone and is associated with telephony and call handling.
  • SIP messages Traces the SIP messages exchanged by the phone.

>

After changing the level for the tracing of SIP messages, the phone must be reboo ted. Otherwise the changes would have no effect.

  • SIP signalling Involved in the creation and parsing of SIP messages. This service communicates directly with the SIP stack.
  • Sidecar service Handles interactions between the phone and any attached sidecars.
  • Team Service Primarily concerned with keyset operation.
  • Tone generation service Handles the generation of the tones and ringers on the phone.
  • Transport service Provides the IP (LAN) interface between the phone and the outside world.
  • USB backup service (V1R3.x upwards) Used to make backup/restore to/from USB stick by using password. This item is available in the phone GUI.
  • vCard parser service (V1R3.x upwards)

Diagnostics

Page 171 of the Siemens 8000 user manual — 3.17.5 Fault Trace Configuration
Seite 171 · Zum Vergrößern klicken
Seite 171
  • Handles parsing and identification of VCard information while sending or getting VCards via Bluetooth.
  • Voice engine Provides a switching mechanism for voice streams within the phone. This component is also involved in QDC, Music on hold and voice instrumentation.
  • Voice mail Handles the voice mail functionality.
  • Voice recognition (V1R3.x upwards) Used by the voice dial facility for recognizing spoken dialing commands.
  • Web Server service Provides access to the phone via web browser.
  • 802.1x service (V1R3.x upwards) Provides authentication to devices attached to a LAN port, establishing a point-to-point connection or preventing access from that port if authentication fails. The service is used for certain closed wireless access points,

Diagnostics

Page 172 of the Siemens 8000 user manual — 3.17.5 Fault Trace Configuration
Seite 172 · Zum Vergrößern klicken
Seite 172

Diagnostics > Fault Trace Configuration

Siemens 8000 — 3.17.5 Fault Trace Configuration diagram (page 172)
Abb. 116 · 3.17.5 Fault Trace Configuration

Diagnostics · Administration via WBM

Page 173 of the Siemens 8000 user manual — 3.17.6 Easy Trace Profiles
Seite 173 · Zum Vergrößern klicken
Seite 173

3.17.6 Easy Trace Profiles

In order to simplify tracing for a specific problem, the tracing levels can be adjusted using pre defined settings. The Easy Trace profiles provide settings for a specific area, e. g. call connec tion. On pressing Submit, those pre-defined settings are sent to the phone. If desired, the set tings can be modified anytime using the general mask for trace configuration under Diagnostics > Fault Trace Configuration (see Section 3.17.5, “Fault Trace Configuration”).

If desired, the tracing for all services can be disabled (see Section 3.17.6.23, “No Tracing for All Services”).

The following sections describe the Easy Trace profiles available for the phone.

3.17.6.1 Bluetooth Handsfree

Diagnostics > Easy Trace Profiles > Bluetooth handsfree profile

Siemens 8000 — 3.17.6 Easy Trace Profiles diagram (page 173)
Abb. 117 · 3.17.6 Easy Trace Profiles

3.17.6.2 Bluetooth Headset

Diagnostics > Easy Trace Profiles > Bluetooth headset profile

Siemens 8000 — 3.17.6 Easy Trace Profiles diagram (page 173)
Abb. 118 · 3.17.6 Easy Trace Profiles

Diagnostics · Administration via WBM · Administration via WBM

Page 174 of the Siemens 8000 user manual — >
Seite 174 · Zum Vergrößern klicken
Seite 174

3.17.6.3 Call Connection

Diagnostics > Easy Trace Profiles > Call connection

Siemens 8000 — 3.17.6.3 Call Connection diagram (page 174)
Abb. 119 · 3.17.6.3 Call Connection

>

This Easy Trace profile contains the tracing of SIP messages. Please note that after changing the level for the tracing of SIP messages, the phone must be rebooted.

3.17.6.4 Call Log

Diagnostics > Easy Trace Profiles > Call log problems

Siemens 8000 — > diagram (page 174)
Abb. 120

Diagnostics · Administration via WBM · Administration via WBM

Page 175 of the Siemens 8000 user manual — 3.17.6.5 LDAP Phonebook
Seite 175 · Zum Vergrößern klicken
Seite 175

3.17.6.5 LDAP Phonebook

Diagnostics > Easy Trace Profiles > Phonebook (LDAP) problems

Siemens 8000 — 3.17.6.5 LDAP Phonebook diagram (page 175)
Abb. 121 · 3.17.6.5 LDAP Phonebook

3.17.6.6 DAS Connection

Diagnostics > Easy Trace Profiles > DAS connection

Siemens 8000 — 3.17.6.5 LDAP Phonebook diagram (page 175)
Abb. 122 · 3.17.6.5 LDAP Phonebook

3.17.6.7 DLS Data Errors

Diagnostics > Easy Trace Profiles > DLS data errors

Siemens 8000 — 3.17.6.5 LDAP Phonebook diagram (page 175)
Abb. 123 · 3.17.6.5 LDAP Phonebook
Show 4 more labels / short text on this page
Diagnostics · Administration via WBM · Administration via WBM · Administration via WBM
Page 176 of the Siemens 8000 user manual — 3.17.6.8 802.1x
Seite 176 · Zum Vergrößern klicken
Seite 176

3.17.6.8 802.1x

Diagnostics > Easy Trace Profiles > 802.1x

Siemens 8000 — 3.17.6.8 802.1x diagram (page 176)
Abb. 124 · 3.17.6.8 802.1x

3.17.6.9 Help Application

Diagnostics > Easy Trace Profiles > Help application problems

Siemens 8000 — 3.17.6.8 802.1x diagram (page 176)
Abb. 125 · 3.17.6.8 802.1x

3.17.6.10 Sidecar

Diagnostics > Easy Trace Profiles > Sidecar problems

Siemens 8000 — 3.17.6.8 802.1x diagram (page 176)
Abb. 126 · 3.17.6.8 802.1x
Show 4 more labels / short text on this page
Diagnostics · Administration via WBM · Administration via WBM · Administration via WBM
Page 177 of the Siemens 8000 user manual — 3.17.6.11 Key Input
Seite 177 · Zum Vergrößern klicken
Seite 177

3.17.6.11 Key Input

Diagnostics > Easy Trace Profiles > Key input problems

Siemens 8000 — 3.17.6.11 Key Input diagram (page 177)
Abb. 127 · 3.17.6.11 Key Input

3.17.6.12 LAN Connectivity

Diagnostics > Easy Trace Profiles > LAN connectivity problems

Siemens 8000 — 3.17.6.11 Key Input diagram (page 177)
Abb. 128 · 3.17.6.11 Key Input

3.17.6.13 Local Phonebook

Diagnostics > Easy Trace Profiles > Phonebook (local) problems

Siemens 8000 — 3.17.6.11 Key Input diagram (page 177)
Abb. 129 · 3.17.6.11 Key Input
Show 4 more labels / short text on this page
Diagnostics · Administration via WBM · Administration via WBM · Administration via WBM
Page 178 of the Siemens 8000 user manual — 3.17.6.14 Messaging
Seite 178 · Zum Vergrößern klicken
Seite 178

3.17.6.14 Messaging

Diagnostics > Easy Trace Profiles > Messaging application problems

Siemens 8000 — 3.17.6.14 Messaging diagram (page 178)
Abb. 130 · 3.17.6.14 Messaging

3.17.6.15 Mobility

Diagnostics > Easy Trace Profiles > Mobility problems

Siemens 8000 — 3.17.6.14 Messaging diagram (page 178)
Abb. 131 · 3.17.6.14 Messaging

3.17.6.16 Phone administration

Diagnostics > Easy Trace Profiles > Phone administration problems

Siemens 8000 — 3.17.6.14 Messaging diagram (page 178)
Abb. 132 · 3.17.6.14 Messaging

Diagnostics · Administration via WBM

Page 179 of the Siemens 8000 user manual — 3.17.6.17 Server based applications
Seite 179 · Zum Vergrößern klicken
Seite 179

3.17.6.17 Server based applications

Diagnostics > Easy Trace Profiles > Server based application problems

Siemens 8000 — 3.17.6.17 Server based applications diagram (page 179)
Abb. 133 · 3.17.6.17 Server based applications

3.17.6.18 Speech

Diagnostics > Easy Trace Profiles > Speech problems

Siemens 8000 — 3.17.6.17 Server based applications diagram (page 179)
Abb. 134 · 3.17.6.17 Server based applications

3.17.6.19 Tone

Diagnostics > Easy Trace Profiles > Tone problems

Siemens 8000 — 3.17.6.17 Server based applications diagram (page 179)
Abb. 135 · 3.17.6.17 Server based applications

3.17.6.20 USB Backup/Restore

Diagnostics > Easy Trace Profiles > USB backup/restore

Siemens 8000 — 3.17.6.17 Server based applications diagram (page 179)
Abb. 136 · 3.17.6.17 Server based applications
Show 4 more labels / short text on this page
Diagnostics · Administration via WBM · Administration via WBM · Administration via WBM
Page 180 of the Siemens 8000 user manual — 3.17.6.21 Voice Dialling
Seite 180 · Zum Vergrößern klicken
Seite 180

3.17.6.21 Voice Dialling

Diagnostics > Easy Trace Profiles > Voice recognition problems

Siemens 8000 — 3.17.6.21 Voice Dialling diagram (page 180)
Abb. 137 · 3.17.6.21 Voice Dialling

3.17.6.22 Web Based Management

Diagnostics > Easy Trace Profiles > Web based management

Siemens 8000 — 3.17.6.21 Voice Dialling diagram (page 180)
Abb. 138 · 3.17.6.21 Voice Dialling

Diagnostics · Administration via WBM · Administration via WBM

Page 181 of the Siemens 8000 user manual — 3.17.6.23 No Tracing for All Services
Seite 181 · Zum Vergrößern klicken
Seite 181

3.17.6.23 No Tracing for All Services

Diagnostics > Easy Trace Profiles > Clear all profiles

Siemens 8000 — 3.17.6.23 No Tracing for All Services diagram (page 181)
Abb. 139 · 3.17.6.23 No Tracing for All Services

Diagnostics · Administration via WBM

Page 182 of the Siemens 8000 user manual — >
Seite 182 · Zum Vergrößern klicken
Seite 182

3.17.7 QoS Reports

3.17.7.1 Conditions and Thresholds for Report Generation

For details about the functionality, please refer to the release notes.

>

The generation of QoS (Quality of Service) reports which are sent to a QCU server (see Sec tion 3.3.8, “SNMP”) is configured here.

  • Report mode : Sets the conditions for generating a QoS report. Value range:
  • "OFF": No reports are generated.
  • "EOS Threshold exceeded": Default value. A report is created if a) a telephone con versation longer than the Minimum session length has just ended, and b) a threshold value has been exceeded during the conversation.
  • "EOR Threshold exceeded": A report is created if a) the report interval has just passed, and b) a threshold value has been exceeded during the observation interval.
  • "EOS (End of Session)": A report is created if a telephone conversation longer than the Minimum session length has just ended.
  • "EOR (End of Report Interval)": A report is created if the report interval has just passed.
  • Report interval (seconds) : Time interval between the periodical observations. Default: 60.
  • Observation interval (seconds) : During this time interval, the traffic is observed. Value: 10.
  • Minimum session length (100 millisecond units) : When the Report mode is set to "EOS Threshold exceeded" or "EOS (End of Session)", a report can be created only if the dura tion of the conversation exceeds this value. Default: 20.
  • Maximum jitter (milliseconds) : When the jitter exceeds this value, a report is generated. Default: 20.
  • Average round trip delay (milliseconds) : When the average round trip time exceeds this value, a report is generated. Default: 100.

Diagnostics · Data required

Page 183 of the Siemens 8000 user manual — 3.17.7 QoS Reports
Seite 183 · Zum Vergrößern klicken
Seite 183
  • Non-compressing codecs / Compressing codes:
  • Lost packets (per 1000 packets) : When the number of lost packets exceeds this maxi mum value during the observation interval, a report is created. Default: 10.
  • Consecutive lost packets : When the number of lost packets following one another ex ceeds this maximum value during the observation interval, a report is created. Default: 2.
  • Consecutive good packets : When the number of good packets following one another falls below this minimum value, a report is created. Default: 8.
  • Resend last report : If checked, the previous report is sent once again on pressing Sub mit . Value range: "Yes", "No". Default: "No".

The transmission of report data can be triggered manually by pressing Send now in the local menu.

Diagnostics > QoS Reports > Generation

Siemens 8000 — 3.17.7 QoS Reports diagram (page 183)
Abb. 140 · 3.17.7 QoS Reports

Diagnostics · Administration via WBM

Page 184 of the Siemens 8000 user manual — 3.17.7 QoS Reports
Seite 184 · Zum Vergrößern klicken
Seite 184

Administration via Local Phone

|--- Administration |--- Network |--- QoS |--- Reports |--- Generation | |--- Mode | |--- Report interval | |--- Observe interval | |--- Minimum session length |--- Send now |--- Thresholds |--- Maximum jitter |--- Round-trip delay |--- Non-compressing: |--- ...Lost packets (K) |--- ...Lost consecutive |--- ...Good consecutive |--- Compressing: |--- ...Lost packets (K) |--- ...Lost consecutive |--- ...Good consecutive

Diagnostics

Page 185 of the Siemens 8000 user manual — 3.17.7.2 View Report
Seite 185 · Zum Vergrößern klicken
Seite 185

3.17.7.2 View Report

OpenStage phones generate QoS reports using a HiPath specific format, QDC (QoS Data Col lection). The reports created for the last 6 sessions, i. e. conversations, can be viewed on the WBM.

  • To enable the generation of reports, please ensure that:
  • the switch QoS traps to QCU (System > SNMP) is activated (see Section 3.3.8, “SNMP”);
  • the conditions for the generation of reports are set adequately (see Section 3.17.7.1, “Con ditions and Thresholds for Report Generation”).

For details about QoS reports on HiPath devices, see the HiPath QoS Data Collection V 1.0 Service Manual.

  • A QoS report contains the following data:
  • Start of report period - seconds : NTP time in seconds for the start of the report period.
  • Start of report period - fraction of seconds : Additional split seconds to be added to the seconds for an exact start time.
  • End of report period - seconds : NTP time in seconds for the end of the report period.
  • End of report period - fraction of seconds : Additional split seconds to be added to the seconds for an exact end time.
  • SNMP specific trap type : The trap type is a 5 bit value calculated from a list of thresholdexceeding bits. Every time a threshold is exceeded, the associated bit is set, otherwise it is cleared. The trace type bits are defined as follows:
  • Bit 0: Jitter threshold was exceeded.
  • Bit 1: Delay threshold was exceeded.
  • Bit 2: Threshold for lost packets was exceeded.
  • Bit 3: Threshold for consecutive lost packets was exceeded.
  • Bit 4: Threshold for consecutive good packets was exceeded.
  • IP address (local) : IP address of the local phone.
  • Port number (local) : RTP receiving port of the local phone.
  • IP address (remote) : IP address of the remote phone that took part in the session.
  • Port number (remote) : RTP sending port of the local phone.
  • SSRC (receiving) : RTP Source Synchronization Identifier of the local phone.
  • SSRC (sending) : RTP Source Synchronization Identifier of the remote phone.
  • Codec : Number of the Payload Type applied in the session; see RFC 3551 (Table 4 and 5).
  • Maximum packet size : Maximum size (in ms) of packets received during the report inter val.

Diagnostics

Page 186 of the Siemens 8000 user manual — 3.17.7.2 View Report
Seite 186 · Zum Vergrößern klicken
Seite 186
  • Silence suppression : Number of silence suppression activation objects found in the RTP stream received. A silence suppression activation object is defined as a period of silence when no encoded voice signals were transmitted by the sender.
  • Count of good packets : Total amount of good packets.
  • Maximum jitter : Maximum jitter (in ms) found during the report interval.
  • Maximum inter-arrival jitter : Maximum of the interarrival jitter values (in ms). The interar rival jitter is the smoothed absolute value of the jitter measurements. It is calculated con tinuously. For details about the calulation, see RFC 3550.
  • Periods jitter threshold exceeded : Number of observation intervals in which the thresh old for maximum jitter was exceeded.
  • Round trip delay : Average value of delay calculated for each RTCP packet. The first value is available after about 15 sec.
  • Round trip delay threshold exceeded : Set to "true" if the average round trip delay thresh old value was exceeded in the report interval.
  • Count of lost packets : Number of packets lost in the course of speech decoding.
  • Count of discarded packets : Number of the packets discarded without transferring the contents.
  • Periods of lost packets : Number of observation intervals in which the threshold for lost packets was exceeded.
  • Consecutive packet loss (CPL) : List of sequences consecutive packets that were all lost, grouped according to the amount of packets per sequence. The first number in the list counts single lost packets, the second number counts sequences of two lost packets, and so on. The last number counts sequences of more than 10 lost packets.
  • Periods of consecutive lost packets : Number of observation intervals in which the threshold for consecutive lost packets was exceeded.
  • Consecutive good packets (CGP) : List of sequences consecutive packets that were all processed, grouped according to the amount of packets per sequence. The first number in the list counts single good packets, the second number counts sequences of two good packets, and so on. The last number counts sequences of more than 10 good packets. All values are reset to 0 after an interval without packet loss.
  • Periods of consecutive good packets : Number of intervals in which the count of lost packets went below the threshold.
  • Count of jitter buffer overruns : Number of packets rejected because the jitter buffer was full.
  • Count of jitter buffer under-runs : Increased by one whenever the decoder requests new information on decoding and finds an empty jitter buffer.
  • Codec change on the fly : The value is 1, if there has been a codec or SSRC change dur ing the observation period, and 0, if there has been no change.
  • Periods with at least one threshold exceeded : Number of observation intervals with at least one threshold exceedance. If there is no data, the value is 255. The threshold values included are:

Diagnostics

Page 187 of the Siemens 8000 user manual — 3.17.7.2 View Report
Seite 187 · Zum Vergrößern klicken
Seite 187
  • maximum jitter;
  • lost packets;
  • consecutive lost packets;
  • consecutive good packets.
  • HiPath Switch ID : Unique number identifying the HiPath switch to which the endpoints are assigned.
  • LTU number : In HiPath 4000 only, the shelf identification is taken from the shelf containing a gateway.
  • Slot number : The slot number where the phoneis connected in the shelf.
  • Endpoint type : Type of the local phone.
  • Version : Software version of the local phone.
  • Subscriber number type : Type of subscriber number assigned to the local phone. The possible types are:
  • 1: local number, extension only;
  • 2: called number, network call
  • 3: E.164 number of the local phone.
  • Subscriber number : Subscriber number of the local phone.
  • Call ID : SIP call id.
  • MAC address : MAC address of the local phone.

Diagnostics

Page 188 of the Siemens 8000 user manual — 3.17.7.2 View Report
Seite 188 · Zum Vergrößern klicken
Seite 188

Data viewing via WBM:

Diagnostics > QoS reports > View Session Data

Siemens 8000 — 3.17.7.2 View Report diagram (page 188)
Abb. 141 · 3.17.7.2 View Report

Diagnostics

Page 189 of the Siemens 8000 user manual — 3.17.9 Remote Tracing - Syslog (V1R4.x upwards)
Seite 189 · Zum Vergrößern klicken
Seite 189

3.17.8 Core dump

If Enable core dump is checked, a core dump will be initiated in case of a severe error. The core dump will be saved to a file. By default, this function is activated.

When File size unlimited is checked, there is no size limit for the core dump file. By default, it is not checked.

The maximum size for core dump files in MBytes can be chosen in the Limited file size (MBs) field. The possible values are 1, 5, 10, 25, 50, 75, and 100. The default value is 100.

If Delete core dump is activated, the current core dump file is deleted on Submit. By default, this is not activated.

If one or more core dump file exist, hyperlinks for downloading will be created automatically.

Diagnostics > Miscellaneous > Core dump

Siemens 8000 — 3.17.8 Core dump diagram (page 189)
Abb. 142 · 3.17.8 Core dump

3.17.9 Remote Tracing - Syslog (V1R4.x upwards)

All trace messages created by the components of the phone software can be sent to a remote server using the syslog protocol. This is helpful especially for long-term observations with a greater number of phones.

To enable remote tracing, Remote trace status must be set to "Enabled". Furthermore, the IP address of the server receiving the syslog messages must be entered in Remote ip, and the corresponding server port must be given in Remote port.

Administration via Local Phone

|--- Administration |--- Maintenance |--- Remote trace |--- Remote trace status |--- Remote ip |--- Remote port

Diagnostics · Administration via WBM

Page 190 of the Siemens 8000 user manual — 3.17.10 Test Interface
Seite 190 · Zum Vergrößern klicken
Seite 190

3.17.10 Test Interface

This parameters enables or disables the test interface (HPT).

Maintenance > Test interface

Administration via Local Phone

|--- Administration |--- Maintenance |--- Disable HPT

Diagnostics · Administration via WBM

Page 191 of the Siemens 8000 user manual — >
Seite 191 · Zum Vergrößern klicken
Seite 191

3.18 Bluetooth

The Bluetooth interface can be enabled or disabled in the admin menu. By default, it is enabled. If Bluetooth is enabled, the user has the possibility to activate or deactivate it.

In version V1R3.x upwards, the Bluetooth address is displayed.

Bluetooth is available only on OpenStage 60/80 phones.

>

V1R2.xBluetooth
Siemens 8000 — > diagram (page 191)
Abb. 143
V1R3.x and upwardsSystem > Features > Feature access > Services
Siemens 8000 — > diagram (page 191)
Abb. 144
V1R4.x and upwardsSystem > Features > Configuration
Siemens 8000 — > diagram (page 191)
Abb. 145

Administration via Local Phone

In V1R2.x, only enabling or disabling Bluetooth is possible via the local admin menu:

Bluetooth · Administration via WBM

Page 192 of the Siemens 8000 user manual — 3.18 Bluetooth
Seite 192 · Zum Vergrößern klicken
Seite 192

|--- Bluetooth |--- Enable

In V1R3.x and upwards, only the device address can be viewed via the local admin menu:

|--- Administration |--- System |--- Features |--- Configuration |--- Bluetooth |--- Local device address

Bluetooth

Page 193 of the Siemens 8000 user manual — 4.1 Canonical Dialing
Seite 193 · Zum Vergrößern klicken
Seite 193

beispiele.fm

4 Examples and HowTos

4.1 Canonical Dialing

4.1.1 Canonical Dialing Settings

The following example shows settings suitable for the conversion of given dial strings to canon ical format. The example phone is located in Nottingham, UK.

Parameter Example value Explanation

Local country code 44 International country code for the UK.

National prefix digit 0 Used in front of national codes when dialled without international prefix.

Local national code 115 Area code within the UK (here: Nottingham).

Minimum local number length

7 Minimum number of digits in a local PSTN number (e. g. 3335333 = 7 digits).

Local enterprise node 780 Prefix to access Nottingham numbers from within the Siemens network.

PSTN access code 9 Prefix to make an international call in the UK.

Operator codes 0, 7800 Set of numbers to access the local operators.

Emergency numbers 999, 555 Set of numbers to access emergency ser vices.

Initial extension digits 2, 3, 4, 5, 6, 8 1st digits of numbers that are used for extensi on numbers on the local node.

Examples and HowTos · Canonical Dialing · Tabelle 4-1

Page 194 of the Siemens 8000 user manual — 4.1.2 Canonical Dial Lookup
Seite 194 · Zum Vergrößern klicken
Seite 194

beispiele.fm

4.1.2 Canonical Dial Lookup

The following example shows settings suitable for recognizing incoming numbers and assign ing them to entries in the local phone book, and for generating correct dial strings from phone book entries, depending on whether the number is internal or external.

Parameter Example value Explanation

Local code 780 Enterprise node prefix (here: Nottingham).

International code +44115943 Equivalent prefix to access numbers on this node from the PSTN. Here, the prefix used by the PSTN (DID/DDI: direct inward dialing) is 943, which differs from the enterprise node prefix used within the enterprise network.

Local code 722 Enterprise node prefix (here: Munich).

International code +4989722 Equivalent prefix to access numbers on this node from the PSTN. Here, the prefix used by the PSTN for direct inward dialing is identical to the enterprise node prefix.

Examples and HowTos · Canonical Dialing

Page 195 of the Siemens 8000 user manual — 4.1.2.1 Conversion examples
Seite 195 · Zum Vergrößern klicken
Seite 195

beispiele.fm

4.1.2.1 Conversion examples

In the following examples, numbers entered into the local phonebook by the user are converted according to the settings given above.

Example 1Internal number, same node as the local phone

External numbers Local public form

International gate way code

Number stored in the phone book

Dial string sent when dialing from the phone book

Internal numbers = Local enterprise form 1234

Internal numbers = Always add node 7802345

Internal numbers = Use external numbers 9432345

Example 2Internal number, different node

External numbers Local public form

International gate way code

Number stored in the phone book

Dial string sent when dialing from the phone book

Internal numbers = Local enterprise form 2345

Internal numbers = Always add node 7802345

Internal numbers = Use external numbers 9432345

Show 13 more labels / short text on this page
Examples and HowTos · Canonical Dialing · User entry 2345 · External access code · Not required · Use national code · +441159432345 · Tabelle 4-2 · User entry 7222345 · External access code · Not required · Use national code · +49897222345
Page 196 of the Siemens 8000 user manual — 4.1.2.1 Conversion examples
Seite 196 · Zum Vergrößern klicken
Seite 196

beispiele.fm

Example 3External number, same local national code as the local phone

External numbers Local public form

International gate way code

Number stored in the phone book

Dial string sent when dialing from the phone book

External numbers = Local public form 234567

External numbers = National public form 011511234567

External numbers = International form 004411511234567

Show 7 more labels / short text on this page
Examples and HowTos · Canonical Dialing · User entry 011511234567 · External access code · Not required · Use national code · +4411511234567
Page 197 of the Siemens 8000 user manual — 4.2 How to Create Logo Files for OpenStage Phones
Seite 197 · Zum Vergrößern klicken
Seite 197

beispiele.fm

Examples and HowTos How to Create Logo Files for OpenStage Phones

4.2 How to Create Logo Files for OpenStage Phones

4.2.1 For OpenStage 40

1. Create a New Image Create an image with the following specifications:
  • Width: 144 px
  • Height: 32 px
  • Color Mode: 1 bit (monochrome) Adobe Photoshop:
Siemens 8000 — 4.2 How to Create Logo Files for OpenStage Phones diagram (page 197)
Abb. 146 · 4.2 How to Create Logo Files for OpenStage Phones
2. Insert the Logo Place the logo image on the background, e.g. by copying it from a source file. Due to the size and color specifications, some adaptations may be necessary. Adobe Photoshop Example:
Siemens 8000 — 4.2 How to Create Logo Files for OpenStage Phones diagram (page 197)
Abb. 147 · 4.2 How to Create Logo Files for OpenStage Phones
3. Save the Image Finally, save the image in BMP format. You can now upload the logo file to the phone as described in Section 3.10.7, “Logo”.
Page 198 of the Siemens 8000 user manual — >
Seite 198 · Zum Vergrößern klicken
Seite 198

beispiele.fm

How to Create Logo Files for OpenStage Phones

4.2.2 For OpenStage 60/80

In the following, the creation of a transparent image suitable for use as a logo in OpenStage 60/ 80 is described. This description is based on Adobe Photoshop, but any similar graphics soft ware can be used as well.

>

Because of performance issues, half transparency in the alpha channel of the PNG files is not allowed on OpenStage phones. Therefore only 100% transparency or no transparency is used in the phone’s UI elements.

1. Select the Background Color For production purposes, we set the background color to the background color of the skin currently selected on the phone. Later, the background color will be replaced by transpar ency, which facilitates placing a logo on a gradient background. The following table lists the hexadecimal values, as used in HTML:

Phone Type Skin Color Code

OpenStage 60 Crystal Sea #BDBDBD

OpenStage 60 Warm Grey #4242421

OpenStage 80 Crystal Sea #E6EBEF

OpenStage 80 Warm Grey #3A3D3A

1 The background color on WP4 - skin 1 is a gradient; the colour listed here is an average value.

Adobe Photoshop: Click on the Background Color icon on the Color palette group, then type the color code without leading "#" into the # field)

Examples and HowTos · Tabelle 4-3

Page 199 of the Siemens 8000 user manual — 4.2.2 For OpenStage 60/80
Seite 199 · Zum Vergrößern klicken
Seite 199

beispiele.fm

Examples and HowTos How to Create Logo Files for OpenStage Phones

2. Create a New Image Create an image with the size according to the phone type:

Phone Type Size (px)

OpenStage 60 240 x 70

OpenStage 80 480 x 142

Adobe Photoshop:

Siemens 8000 — 4.2.2 For OpenStage 60/80 diagram (page 199)
Abb. 148 · 4.2.2 For OpenStage 60/80
3. Insert the Logo Place the logo image on the background, e.g. by copying it from a source file. Adobe Photoshop Example:
Siemens 8000 — 4.2.2 For OpenStage 60/80 diagram (page 199)
Abb. 149 · 4.2.2 For OpenStage 60/80
4. Merge Layers Merge the two layers to one. Adobe Photoshop: In the Panel, select both the background layer and the new layer containing the inserted logo. Afterwards, go to Layer in the Menu bar, and select Merge Layers .

Tabelle 4-4

Page 200 of the Siemens 8000 user manual — 4.2.2 For OpenStage 60/80
Seite 200 · Zum Vergrößern klicken
Seite 200

beispiele.fm

How to Create Logo Files for OpenStage Phones

5. Background Transparency Delete the background colour so that only the exact former background colour is 100% transparent. Adobe Photoshop: Make sure that the background color is selected by clicking on the Background Color icon. In the Tool palette, click on the Eraser symbol with the right Mouse button and select the Magic Eraser Tool . After this, got to the Menu bar and set the Tolerance field to "0".
Siemens 8000 — 4.2.2 For OpenStage 60/80 diagram (page 200)
Abb. 150 · 4.2.2 For OpenStage 60/80
6. Save the Image Finally, save the image in PNG format. You can now upload the logo file to the phone as described in Section 3.10.7, “Logo”.

Examples and HowTos

Page 201 of the Siemens 8000 user manual — 4.3.1 Prerequisites:
Seite 201 · Zum Vergrößern klicken
Seite 201

beispiele.fm

Examples and HowTos How to Set Up the Corporate Phonebook (LDAP)

4.3 How to Set Up the Corporate Phonebook (LDAP)

The Corporate Phonebook function is based on an LDAP client that can be connected to the company’s LDAP service. A variety of LDAP servers can be used, for instance Microsoft Active Directory, OpenLDAP, or Apache Directory Server.

>

The Corporate Phonebook is available only on OpenStage 60/80.

4.3.1 Prerequisites:

1. An LDAP server is present and accessible to the phone’s network. The standard port for LDAP is 389 .
2. Query access to the LDAP server must be provided. Unless anonymous access is used, a user name and passwort must be provided. It might be feasible to use a single login/pass word for all OpenStage phones.

3. To enable dialing internal numbers from the corporate phonebook, an LDAP entry must be provided that contains the proper number format required by the HiPath 8000. In Microsoft Active Directory, the standard LDAP attribute telephoneNumber is typically populated as follows: +1<area code><call number>. However, in a standard configura tion, the HiPath 8000 will not handle this dial string correctly, due to the +1 prefix. There fore, it is recommended to use the ipPhone field, which is typically unused in Active Direc tory. It can be found in the Telephones tab of the Active Directory User Manager.

Page 202 of the Siemens 8000 user manual — 4.3.2 Create an LDAP Template
Seite 202 · Zum Vergrößern klicken
Seite 202

beispiele.fm

How to Set Up the Corporate Phonebook (LDAP)

4.3.2 Create an LDAP Template

The user interface of the corporate phonebook application provides a form which is used both for search and retrieval.

Siemens 8000 — 4.3.2 Create an LDAP Template diagram (page 202)
Abb. 151 · 4.3.2 Create an LDAP Template

The task of an LDAP template is to map the phone’s search and display fields to LDAP at tributes that can be delivered by the server. In the LDAP template, the fields are represented by hard-coded names: ATTRIB01, ATTRIB02, and so on. These field names are assigned to LDAP attributes, as appropriate.

Examples and HowTos

Page 203 of the Siemens 8000 user manual — 4.3.2 Create an LDAP Template
Seite 203 · Zum Vergrößern klicken
Seite 203

beispiele.fm

Examples and HowTos How to Set Up the Corporate Phonebook (LDAP)

The following examples show the relations between GUI field names, the attribute labels used in the template, and exemplary mappings to LDAP attributes.

Generic Example (Standard Attributes)

OpenStage Field LDAP Template Lables

LDAP Attribute Example Value

Last name ATTRIB01 sn Doe

First name ATTRIB02 givenName John

Business 1 ATTRIB03 telephoneNumber 9991234

Business 2 ATTRIB04 facsimileTelephoneNumber 9992345

Mobile ATTRIB05 mobile 017711223344

Private ATTRIB06 homePhone 441274333444

Company ATTRIB07 o Example Inc.

Address 1 ATTRIB08 departmentNumber 0815

Job function ATTRIB10 title Product Manager

Email ATTRIB11 mail doe@example.com

Given "example.com" as the LDAP subtree to be searched, the LDAP template file would look like this:

OpenStage LDAP TEMPLATE (v.1) SEARCHBASE="dc=example,dc=com" ATTRIB01="sn" ATTRIB02="givenname" ATTRIB03="telephoneNumber" ATTRIB04="facsimileTelephoneNumber" ATTRIB05="mobile" ATTRIB06="homePhone" ATTRIB07="o" ATTRIB08="departmentNumber" ATTRIB09="" ATTRIB10="title" ATTRIB11="mail" EOF

Address 2 ATTRIB09

Page 204 of the Siemens 8000 user manual — 4.3.2 Create an LDAP Template
Seite 204 · Zum Vergrößern klicken
Seite 204

beispiele.fm

How to Set Up the Corporate Phonebook (LDAP)

Microsoft Active Directory Specific Example

OpenStage Field LDAP Template Attribute

LDAP Attribute Example Value

Last name ATTRIB01 sn Doe

First name ATTRIB02 givenName John

Business 1 ATTRIB03 ipPhone 9991234

Business 2 ATTRIB04 otherTelephone 9992345

Mobile ATTRIB05 mobile 017711223344

Private ATTRIB06 homePhone 441274333444

Company ATTRIB07 company Example Inc.

Address 1 ATTRIB08 department Administration

Job function ATTRIB10 title Product Manager

Email ATTRIB11 mail doe@example.com

Given "example.com" as the LDAP subtree to be searched, the LDAP template file would look like this:

OpenStage LDAP TEMPLATE (v.1) SEARCHBASE="dc=example,dc=com" ATTRIB01="sn" ATTRIB02="givenname" ATTRIB03="ipPhone" ATTRIB04="otherTelephone" ATTRIB05="mobile" ATTRIB06="homePhone" ATTRIB07="company" ATTRIB08="department" ATTRIB09="" ATTRIB10="title" ATTRIB11="mail" EOF

Examples and HowTos · Address 2 ATTRIB09

Page 205 of the Siemens 8000 user manual — 4.3.3 Load the LDAP Template into the Phone
Seite 205 · Zum Vergrößern klicken
Seite 205

beispiele.fm

Examples and HowTos How to Set Up the Corporate Phonebook (LDAP)

4.3.3 Load the LDAP Template into the Phone

When you have configured the LDAP template, you can upload it to the phone:

1. Save the template under a suitable name, for example, ldap-template.txt .
2. Copy the template file to the FTP server designated for deploying LDAP templates.
3. Upload the file using the WBM (see Section 3.10.6, “LDAP Template”), or, alternatively, the Local menu, or the DLS (see the Deployment Service Administration Manual). For an ex ample configuration, see the following WBM screenshot (path: File transfer > LDAP):
Siemens 8000 — 4.3.3 Load the LDAP Template into the Phone diagram (page 205)
Abb. 152 · 4.3.3 Load the LDAP Template into the Phone
Page 206 of the Siemens 8000 user manual — 4.3.5 Test
Seite 206 · Zum Vergrößern klicken
Seite 206

beispiele.fm

How to Set Up the Corporate Phonebook (LDAP)

4.3.4 Configure LDAP Access

To enter the access data using the WBM, take the following steps:

1. Navigate to Local Functions > Directory Settings.
2. Enter the following parameters:
  • Server address (IP address or hostname of the LDAP server)
  • Server port (port used by the LDAP, typically 389)
  • Authentication (authentication method for the connection to the LDAP server)
  • User name (only required if simple authentication is selected); Password (relating to the user name).
Siemens 8000 — 4.3.4 Configure LDAP Access diagram (page 206)
Abb. 153 · 4.3.4 Configure LDAP Access
3. Press Submit .

4.3.5 Test

If everything went well, you can run a test query on your OpenStage phone.

1. To navigate to the phone’s corporate phonebook, press the u button twice.
2. Press g on the TouchGuide. In the context menu, select Find by pressing i .
3. In the query mask, select the entry to be searched, for instance Last Name . Press i to open the onscreen keypad for text input.

Examples and HowTos

Page 207 of the Siemens 8000 user manual — 4.3.4 Configure LDAP Access
Seite 207 · Zum Vergrößern klicken
Seite 207

beispiele.fm

Examples and HowTos How to Set Up the Corporate Phonebook (LDAP)

4. Enter the text to be searched. For information on using the onscreen keypad, see Section 3.1, “Access via Local Phone”, step 5.
Siemens 8000 — 4.3.4 Configure LDAP Access diagram (page 207)
Abb. 154 · 4.3.4 Configure LDAP Access
6. Navigate to the Find option and press i . If the query was successful, at least one entry will be listed in the following manner:
Siemens 8000 — 4.3.4 Configure LDAP Access diagram (page 207)
Abb. 155 · 4.3.4 Configure LDAP Access
Page 208 of the Siemens 8000 user manual — 4.3.4 Configure LDAP Access
Seite 208 · Zum Vergrößern klicken
Seite 208

beispiele.fm

How to Set Up the Corporate Phonebook (LDAP)

7. Navigate to the desired entry and press g on the TouchGuide to open the context menu. You can select one of the following options:
  • Dial the Business 1 number.
  • Dial the Mobile number.
  • Have the entry’s details, that is, all attributes displayed.
  • Start a new search.
  • Clear the list of search results.
Siemens 8000 — 4.3.4 Configure LDAP Access diagram (page 208)
Abb. 156 · 4.3.4 Configure LDAP Access

Examples and HowTos ·

Page 209 of the Siemens 8000 user manual — 5.1.1 Web Interface Menu
Seite 209 · Zum Vergrößern klicken
Seite 209

referenz.fm

5 Technical Reference

5.1 Menus

>

This section describes the structure of the administration menus of the OpenStage phone. For information on user menus, please refer to the user manual.

5.1.1 Web Interface Menu

5.1.1.1 Menu Structure

Add application Modify application Xpressions

IP configuration (V1R2.x) / IP configuration (V1R3.x upwards) Update Service (DLS) QoS Port configuration (V1R2.x and V1R3.x on OpenStage 20/40) / Port configuration (V1R3.x upwards on OpenStage 60/80)

System Identity SIP interface (V1R2.x) / SIP interface (V1R3.x) Registration SNMP Features

Configuration (V1R2.x) / Configuration (V1R3.x upwards on OpenStage 20/40) / Con figuration (V1R3.x upwards on OpenStage 60/80) DSS settings3

1. OpenStage 60/80 only. 2. In V1R3.x upwards, this parameter has moved to System > Features > 3. OpenStage 40/60/80 only.
Show 8 more labels / short text on this page
Technical Reference · Menus · Admin Login · Applications · XML applications1 · Bluetooth1 2 · Network · System
Page 210 of the Siemens 8000 user manual — LDAP 1
Seite 210 · Zum Vergrößern klicken
Seite 210

referenz.fm

Program keys > Line2

Key Module 12

Key Module 22

Services Feature access1

Services (V1R3.x) Security (V1R4.x)

Defaults Phone application Hold music Picture Clip1

LDAP 1

Ringer file Dongle key

Canonical dial settings Canonical dial lookup Canonical dial Pixel Saver (V1R4.x)

Codec preferences Audio settings

Change Admin password Change User password

Fault trace configuration EasyTrace Profiles

Show 14 more labels / short text on this page
Technical Reference · Menus · Keyset operation2 · File transfer · Logo3 · Screensaver1 · Local functions · Directory settings1 · Locality · Date and time · Speech · General information · Authentication · Diagnostics
Page 211 of the Siemens 8000 user manual — 5 Technical Reference
Seite 211 · Zum Vergrößern klicken
Seite 211

referenz.fm

Bluetooth handsfree profile1

Bluetooth headset profile1

Call connection Call log problems DAS connection DLS data errors Help application problems1

Key input problems LAN connectivity problems Messaging application problems Mobility problems Phone administration problems Phonebook (LDAP) problems1

Phonebook (local) problems1

Server based application problems1

Sidecar problems Speech problems Tone problems USB backup/restore1

Voice recognition problems1

Web based management 802.1x problems Clear all profiles QoS Reports

Generation View Session Data Miscellaneous

IP tests Memory information Core dump

Remote trace (V1R4.x upwards) Restart phone Factory reset HPT interface

Technical Reference · Menus · Maintenance

Page 212 of the Siemens 8000 user manual — 5.1.1.2 Web Pages
Seite 212 · Zum Vergrößern klicken
Seite 212

referenz.fm

5.1.1.2 Web Pages

Show 5 more labels / short text on this page
Technical Reference · Menus · Admin Login · Add application · Modify application
Page 213 of the Siemens 8000 user manual — 5.1.1.2 Web Pages
Seite 213 · Zum Vergrößern klicken
Seite 213

referenz.fm

Siemens 8000 — 5.1.1.2 Web Pages diagram (page 213)
Abb. 157 · 5.1.1.2 Web Pages

IP configuration (V1R2.x)

Siemens 8000 — 5.1.1.2 Web Pages diagram (page 213)
Abb. 158 · 5.1.1.2 Web Pages
Show 4 more labels / short text on this page
Technical Reference · Menus · Xpressions · Bluetooth
Page 214 of the Siemens 8000 user manual — 5.1.1.2 Web Pages
Seite 214 · Zum Vergrößern klicken
Seite 214

referenz.fm

IP configuration (V1R3.x upwards)

Siemens 8000 — 5.1.1.2 Web Pages diagram (page 214)
Abb. 159 · 5.1.1.2 Web Pages
Siemens 8000 — 5.1.1.2 Web Pages diagram (page 214)
Abb. 160 · 5.1.1.2 Web Pages
Show 4 more labels / short text on this page
Technical Reference · Menus · Update Service (DLS) · QoS
Page 215 of the Siemens 8000 user manual — 5.1.1.2 Web Pages
Seite 215 · Zum Vergrößern klicken
Seite 215

referenz.fm

Port configuration (V1R2.x and V1R3.x on OpenStage 20/40)

Siemens 8000 — 5.1.1.2 Web Pages diagram (page 215)
Abb. 161 · 5.1.1.2 Web Pages

Port configuration (V1R3.x upwards on OpenStage 60/80)

Siemens 8000 — 5.1.1.2 Web Pages diagram (page 215)
Abb. 162 · 5.1.1.2 Web Pages
Siemens 8000 — 5.1.1.2 Web Pages diagram (page 215)
Abb. 163 · 5.1.1.2 Web Pages

Technical Reference · Menus · System Identity

Page 216 of the Siemens 8000 user manual — 5.1.1.2 Web Pages
Seite 216 · Zum Vergrößern klicken
Seite 216

referenz.fm

SIP interface (V1R2.x)

Siemens 8000 — 5.1.1.2 Web Pages diagram (page 216)
Abb. 164 · 5.1.1.2 Web Pages

SIP interface (V1R3.x)

Siemens 8000 — 5.1.1.2 Web Pages diagram (page 216)
Abb. 165 · 5.1.1.2 Web Pages
Siemens 8000 — 5.1.1.2 Web Pages diagram (page 216)
Abb. 166 · 5.1.1.2 Web Pages

Technical Reference · Menus · Registration

Page 217 of the Siemens 8000 user manual — SNMP
Seite 217 · Zum Vergrößern klicken
Seite 217

referenz.fm

SNMP

Configuration (V1R2.x)

Siemens 8000 — SNMP diagram (page 217)
Abb. 167

Technical Reference · Menus

Page 218 of the Siemens 8000 user manual — 5.1.1.2 Web Pages
Seite 218 · Zum Vergrößern klicken
Seite 218

referenz.fm

Configuration (V1R3.x upwards on OpenStage 20/40)

Siemens 8000 — 5.1.1.2 Web Pages diagram (page 218)
Abb. 168 · 5.1.1.2 Web Pages

Configuration (V1R3.x upwards on OpenStage 60/80)

Siemens 8000 — 5.1.1.2 Web Pages diagram (page 218)
Abb. 169 · 5.1.1.2 Web Pages

Technical Reference · Menus · DSS settings

Page 219 of the Siemens 8000 user manual — 5.1.1.2 Web Pages
Seite 219 · Zum Vergrößern klicken
Seite 219

referenz.fm

Show 4 more labels / short text on this page
Technical Reference · Menus · Program keys · Line
Page 220 of the Siemens 8000 user manual — 5.1.1.2 Web Pages
Seite 220 · Zum Vergrößern klicken
Seite 220

referenz.fm

Show 4 more labels / short text on this page
Technical Reference · Menus · Key Module 1 · Key Module 2
Page 221 of the Siemens 8000 user manual — 5.1.1.2 Web Pages
Seite 221 · Zum Vergrößern klicken
Seite 221

referenz.fm

Siemens 8000 — 5.1.1.2 Web Pages diagram (page 221)
Abb. 170 · 5.1.1.2 Web Pages

Services (V1R3.x)

Security (V1R4.x)

Show 4 more labels / short text on this page
Technical Reference · Menus · Keyset operation · Services
Page 222 of the Siemens 8000 user manual — 5.1.1.2 Web Pages
Seite 222 · Zum Vergrößern klicken
Seite 222

referenz.fm

Show 5 more labels / short text on this page
Technical Reference · Menus · Defaults · Phone application · Hold music
Page 223 of the Siemens 8000 user manual — LDAP
Seite 223 · Zum Vergrößern klicken
Seite 223

referenz.fm

LDAP

Show 4 more labels / short text on this page
Technical Reference · Menus · Picture Clip · Logo
Page 224 of the Siemens 8000 user manual — 5.1.1.2 Web Pages
Seite 224 · Zum Vergrößern klicken
Seite 224

referenz.fm

Siemens 8000 — 5.1.1.2 Web Pages diagram (page 224)
Abb. 171 · 5.1.1.2 Web Pages
Show 5 more labels / short text on this page
Technical Reference · Menus · Screensaver · Ringer file · Dongle key
Page 225 of the Siemens 8000 user manual — 5.1.1.2 Web Pages
Seite 225 · Zum Vergrößern klicken
Seite 225

referenz.fm

Show 6 more labels / short text on this page
Technical Reference · Menus · Directory settings · Canonical dial settings · Canonical dial lookup · Canonical dial
Page 226 of the Siemens 8000 user manual — 5.1.1.2 Web Pages
Seite 226 · Zum Vergrößern klicken
Seite 226

referenz.fm

Pixel Saver (V1R4.x)

Show 6 more labels / short text on this page
Technical Reference · Menus · Date and time · Codec preferences · Audio settings · General information
Page 227 of the Siemens 8000 user manual — 5.1.1.2 Web Pages
Seite 227 · Zum Vergrößern klicken
Seite 227

referenz.fm

Show 4 more labels / short text on this page
Technical Reference · Menus · Change Admin password · Change User password
Page 228 of the Siemens 8000 user manual — 5.1.1.2 Web Pages
Seite 228 · Zum Vergrößern klicken
Seite 228

referenz.fm

Show 4 more labels / short text on this page
Technical Reference · Menus · Fault trace configuration · Bluetooth handsfree profile
Page 229 of the Siemens 8000 user manual — 5.1.1.2 Web Pages
Seite 229 · Zum Vergrößern klicken
Seite 229

referenz.fm

Siemens 8000 — 5.1.1.2 Web Pages diagram (page 229)
Abb. 172 · 5.1.1.2 Web Pages
Show 6 more labels / short text on this page
Technical Reference · Menus · Bluetooth headset profile · Call connection · Call log problems · DAS connection
Page 230 of the Siemens 8000 user manual — 5.1.1.2 Web Pages
Seite 230 · Zum Vergrößern klicken
Seite 230

referenz.fm

Siemens 8000 — 5.1.1.2 Web Pages diagram (page 230)
Abb. 173 · 5.1.1.2 Web Pages
Show 6 more labels / short text on this page
Technical Reference · Menus · DLS data errors · Help application problems · Key input problems · LAN connectivity problems
Page 231 of the Siemens 8000 user manual — 5.1.1.2 Web Pages
Seite 231 · Zum Vergrößern klicken
Seite 231

referenz.fm

Siemens 8000 — 5.1.1.2 Web Pages diagram (page 231)
Abb. 174 · 5.1.1.2 Web Pages
Show 6 more labels / short text on this page
Technical Reference · Menus · Messaging application problems · Mobility problems · Phone administration problems · Phonebook (LDAP) problems
Page 232 of the Siemens 8000 user manual — 5.1.1.2 Web Pages
Seite 232 · Zum Vergrößern klicken
Seite 232

referenz.fm

Server based application problems

Show 6 more labels / short text on this page
Technical Reference · Menus · Phonebook (local) problems · Sidecar problems · Speech problems · Tone problems
Page 233 of the Siemens 8000 user manual — 5.1.1.2 Web Pages
Seite 233 · Zum Vergrößern klicken
Seite 233

referenz.fm

Show 5 more labels / short text on this page
Technical Reference · Menus · USB backup/restore · Voice recognition problems · Web based management
Page 234 of the Siemens 8000 user manual — 5.1.1.2 Web Pages
Seite 234 · Zum Vergrößern klicken
Seite 234

referenz.fm

802.1x problems

Technical Reference · Menus · Clear all profiles

Page 235 of the Siemens 8000 user manual — 5.1.1.2 Web Pages
Seite 235 · Zum Vergrößern klicken
Seite 235

referenz.fm

Technical Reference · Menus · Generation

Page 236 of the Siemens 8000 user manual — 5.1.1.2 Web Pages
Seite 236 · Zum Vergrößern klicken
Seite 236

referenz.fm

Technical Reference · Menus · View Session Data

Page 237 of the Siemens 8000 user manual — 5.1.1.2 Web Pages
Seite 237 · Zum Vergrößern klicken
Seite 237

referenz.fm

Siemens 8000 — 5.1.1.2 Web Pages diagram (page 237)
Abb. 175 · 5.1.1.2 Web Pages

Remote trace (V1R4.x upwards)

Show 5 more labels / short text on this page
Technical Reference · Menus · IP tests · Memory information · Core dump
Page 238 of the Siemens 8000 user manual — 5.1.1.2 Web Pages
Seite 238 · Zum Vergrößern klicken
Seite 238

referenz.fm

Remote trace (V1R4.x)

Show 5 more labels / short text on this page
Technical Reference · Menus · Restart phone · Factory reset · HPT interface
Page 239 of the Siemens 8000 user manual — 5.1.2 Local Phone Menu
Seite 239 · Zum Vergrößern klicken
Seite 239

referenz.fm

5.1.2 Local Phone Menu

Menu Further information ... |--- Administration | |--- Applications | | |--- CPP | | |--- Java | | |--- XML | | |--- Add application1 |--- Display name -> Section 3.13.1 |--- Application name -> Section 3.13.1 |--- Server address -> Section 3.13.1 |--- Server port -> Section 3.13.1 |--- Protocol -> Section 3.13.1 |--- Program name -> Section 3.13.1 |--- Use proxy -> Section 3.13.1 |--- XML trace enabled -> Section 3.13.1 |--- Debug program name -> Section 3.13.1 | | |--- Add Xpressions1 | | |--- Display name -> Section 3.13.1 | | |--- Application name -> Section 3.13.1 | | |--- Server address -> Section 3.13.1 | | |--- Server port -> Section 3.13.1 | | |--- Protocol -> Section 3.13.1 | | |--- Program name -> Section 3.13.1 | | |--- Use proxy -> Section 3.13.1 | | |--- XML trace enabled -> Section 3.13.1 | | |--- Debug program name -> Section 3.13.1 | |--- Bluetooth | | |--- Enable2 -> Section 3.18 | |--- Network | | |--- IP configuration |--- Use DHCP -> Section 3.2.2 |--- IP address -> Section 3.3.3 |--- Subnet mask -> Section 3.3.3 |--- Route (default) -> Section 3.3.4 |--- DNS domain -> Section 3.3.6.1 |--- Primary DNS -> Section 3.3.6.2 |--- Secondary DNS -> Section 3.3.6.2 |--- Route 1 IP -> Section 3.3.6 |--- Route 1 gateway -> Section 3.3.6 |--- Route 1 mask -> Section 3.3.6 |--- Route 2 IP -> Section 3.3.6 |--- Route 2 gateway -> Section 3.3.6 |--- Route 2 mask -> Section 3.3.6 |--- VLAN discovery -> Section 3.2.2.1 |--- VLAN ID -> Section 3.2.2.2 |--- HTTP proxy3 -> Section 3.13.1.2 | | |--- Update Service (DLS) |--- DLS address -> Section 3.3.7

Technical Reference · Menus

Page 240 of the Siemens 8000 user manual — 5.1.2 Local Phone Menu
Seite 240 · Zum Vergrößern klicken
Seite 240

referenz.fm

Menu Further information ...

|--- DLS port -> Section 3.3.7 |--- Contact gap -> Section 3.3.7 |--- Security status -> Section 3.3.7 | | |--- QoS |--- Service |--- Layer 2 -> Section 3.3.1.1 |--- Layer 2 voice -> Section 3.3.1.1 |--- Layer 2 signalling -> Section 3.3.1.1 |--- Layer 2 default -> Section 3.3.1.1 |--- Layer 3 -> Section 3.3.1.2 |--- Layer 3 voice -> Section 3.3.1.2 |--- Layer 3 signalling -> Section 3.3.1.2 |--- Reports |--- Generation |--- Mode -> Section 3.17.7 |--- Report interval -> Section 3.17.7 |--- Observe interval -> Section 3.17.7 |--- Minimum session length -> Section 3.17.7 |--- Send now -> Section 3.17.7.1 |--- Thresholds |--- Maximum jitter -> Section 3.17.7 |--- Round-trip delay -> Section 3.17.7 |--- Non-compressing: |--- ...Lost packets (K) -> Section 3.17.7 |--- ...Lost consecutive -> Section 3.17.7 |--- ...Good consecutive -> Section 3.17.7 |--- Compressing: |--- ...Lost packets (K) -> Section 3.17.7 |--- ...Lost consecutive -> Section 3.17.7 |--- ...Good consecutive -> Section 3.17.7 | | |--- Port configuration | | |--- SIP server -> Section 3.5.5.2 | | |--- SIP registrar -> Section 3.5.5.2 | | |--- SIP gateway -> Section 3.5.5.2 | | |--- SIP local -> Section 3.5.5.2 | | |--- Backup proxy -> Section 3.5.9 | | |--- RTP base -> Section 3.12.1 | | |--- LDAP server port | | |--- LAN port type -> Section 3.2.1 | | |--- PC port status -> Section 3.2.1 | | |--- PC port type -> Section 3.2.1 | | |--- PC port autoMDIX -> Section 3.2.1 | | |--- HTTP proxy -> Section 3.13.1.2 | |--- System | | |--- Identity |--- Terminal number -> Section 3.5.1.1 |--- Terminal name -> Section 3.5.1.1 |--- Display identity -> Section 3.5.1.2 |--- Enable ID -> Section 3.5.1.2 | | |--- SIP Interface |--- Outbound proxy -> Section 3.5.7.3

Technical Reference · Menus

Page 241 of the Siemens 8000 user manual — 5.1.2 Local Phone Menu
Seite 241 · Zum Vergrößern klicken
Seite 241

referenz.fm

Menu Further information ...

|--- Default OBP domain -> Section 3.5.7.3 |--- SIP transport -> Section 3.5.7.4 |--- Response timer (ms) -> Section 3.5.7.1 |--- Connectivity timer (ms) -> Section 3.5.7.2 | | |--- Registration |--- SIP addresses |--- SIP server -> Section 3.5.5.1 |--- SIP registrar -> Section 3.5.5.1 |--- SIP gateway -> Section 3.5.5.1 |--- SIP session |--- Session timer -> Section 3.5.8 |--- Session duration (s) -> Section 3.5.8 |--- Registration timer (s) -> Section 3.5.6 |--- Server type -> Section 3.5.6 |--- Realm -> Section 3.5.6 |--- User ID -> Section 3.5.6 |--- Password -> Section 3.5.6 |--- SIP survivability |--- Backup registration flag -> Section 3.5.9 |--- Backup proxy address -> Section 3.5.9 |--- Backup registration timer (s) -> Section 3.5.9 |--- Backup transport -> Section 3.5.9 |--- OBP flag -> Section 3.5.9 | | |--- SNMP |--- Trap sending enabled -> Section 3.3.8 |--- Trap destination -> Section 3.3.8 |--- Trap destination port -> Section 3.3.8 |--- Trap community -> Section 3.3.8 |--- Diagnostic sending enabled -> Section 3.3.8 |--- Diagnostic destination -> Section 3.3.8 |--- Diagnostic destination port -> Section 3.3.8 |--- Diagnostic community -> Section 3.3.8 |--- QoS traps to QCU -> Section 3.3.8 |--- QCU address -> Section 3.3.8 |--- QCU port -> Section 3.3.8 |--- QCU community -> Section 3.3.8 |--- QoS to generic destination -> Section 3.3.8 | | |--- Features |--- Configuration |--- General |--- Emergency number -> Section 3.5.2 |--- Voicemail number -> Section 3.5.2 |--- Allow refuse -> Section 3.6.1 |--- Initial digit timer -> Section 3.6.3 |--- Allow uaCSTA -> Section 3.6.8 |--- Server features4 -> Section 3.6.7 |--- Transfer on hangup -> Section 3.6.3.2 |--- Not used timeout -> Section 3.6.9 |--- DSS Pickup timer -> Section 3.7.3.1 |--- Audio |--- Group pickup tone allowed5 -> Section 3.6.2.2

Technical Reference · Menus

Page 242 of the Siemens 8000 user manual — 5.1.2 Local Phone Menu
Seite 242 · Zum Vergrößern klicken
Seite 242

referenz.fm

Menu Further information ...

|--- Group pickup as ringer5 -> Section 3.6.2.2 |--- Group pickup visual alert5 -> Section 3.6.2.2 |--- Keyset Lines5 |--- Details For Keyset Line |--- Address -> Section 3.7.1 |--- Ring on/off -> Section 3.7.1 |--- Selection order -> Section 3.7.1 |--- Bluetooth1 |--- Local device address -> Section 3.18 |--- Keyset operation5 |--- Rollover ring -> Section 3.7.2 |--- LED on registration -> Section 3.7.2 |--- Originating line preference -> Section 3.7.2 |--- Terminating line preference -> Section 3.7.2 |--- Line action mode -> Section 3.7.2 |--- Show focus -> Section 3.7.2 |--- Reservation timer -> Section 3.7.2 |--- Forwarding indicated -> Section 3.7.2 |--- Preselect mode -> Section 3.7.2 |--- Preselect timer -> Section 3.7.2 |--- Addressing |--- MWI server URI -> Section 3.6.5 |--- Conference -> Section 3.6.6 |--- Group pickup URI -> Section 3.6.2 |--- Callback: busy -> Section 3.6.4 |--- Callback: no reply -> Section 3.6.4 |--- Callback: cancel all -> Section 3.6.4 |--- Feature Access |--- Call establish |--- Deflect to DSS -> Section 3.7.3.1 |--- Refuse DSS pickup -> Section 3.7.3.1 | | |--- Security6 | | |--- Server cerfificate -> Section 3.4 | | |--- Backup certificate -> Section 3.4 | | |--- Use secure calls -> Section 3.4 | |--- File Transfer | | |--- Defaults -> Section 3.10.2 |--- Download method -> Section 3.10.2 |--- Server -> Section 3.10.2 |--- Port -> Section 3.10.2 |--- Account -> Section 3.10.2 |--- Username -> Section 3.10.2 |--- Password -> Section 3.10.2 |--- FTP path -> Section 3.10.2 |--- HTTPS base URL -> Section 3.10.2 | | |--- Phone app -> Section 3.10.3 |--- Use default -> Section 3.10.3.1 |--- Download method -> Section 3.10.3.1 |--- Server -> Section 3.10.3.1 |--- Port -> Section 3.10.3.1 |--- Account -> Section 3.10.3.1

Technical Reference · Menus

Page 243 of the Siemens 8000 user manual — 5.1.2 Local Phone Menu
Seite 243 · Zum Vergrößern klicken
Seite 243

referenz.fm

Menu Further information ...

|--- Username -> Section 3.10.3.1 |--- Password -> Section 3.10.3.1 |--- FTP path -> Section 3.10.3.1 |--- HTTPS base URL -> Section 3.10.3.1 |--- Filename -> Section 3.10.3.1 | | |--- Hold Music |--- Use default -> Section 3.10.4.1 |--- Download method -> Section 3.10.4.1 |--- Server -> Section 3.10.4.1 |--- Port -> Section 3.10.4.1 |--- Account -> Section 3.10.4.1 |--- Username -> Section 3.10.4.1 |--- Password -> Section 3.10.4.1 |--- FTP path -> Section 3.10.4.1 |--- HTTPS base URL -> Section 3.10.4.1 |--- Filename -> Section 3.10.4.1 | | |--- Ringer |--- Use default -> Section 3.10.6.1 |--- Download method -> Section 3.10.6.1 |--- Server -> Section 3.10.6.1 |--- Port -> Section 3.10.6.1 |--- Account -> Section 3.10.6.1 |--- Username -> Section 3.10.6.1 |--- Password -> Section 3.10.6.1 |--- FTP path -> Section 3.10.6.1 |--- HTTPS base URL -> Section 3.10.6.1 |--- Filename -> Section 3.10.6.1 | | |--- Picture clip3 |--- Use default -> Section 3.10.5.1 |--- Download method -> Section 3.10.5.1 |--- Server -> Section 3.10.5.1 |--- Port -> Section 3.10.5.1 |--- Account -> Section 3.10.5.1 |--- Username -> Section 3.10.5.1 |--- Password -> Section 3.10.5.1 |--- FTP path -> Section 3.10.5.1 |--- HTTPS base URL -> Section 3.10.5.1 |--- Filename -> Section 3.10.5.1 | | |--- LDAP3 |--- Use default -> Section 3.10.6.1 |--- Download method -> Section 3.10.6.1 |--- Server -> Section 3.10.6.1 |--- Port -> Section 3.10.6.1 |--- Account -> Section 3.10.6.1 |--- Username -> Section 3.10.6.1 |--- Password -> Section 3.10.6.1 |--- FTP path -> Section 3.10.6.1 |--- HTTPS base URL -> Section 3.10.6.1 |--- Filename -> Section 3.10.6.1 | | |--- Logo5 |--- Use default -> Section 3.10.7.1

Technical Reference · Menus

Page 244 of the Siemens 8000 user manual — 5.1.2 Local Phone Menu
Seite 244 · Zum Vergrößern klicken
Seite 244

referenz.fm

Menu Further information ...

|--- Download method -> Section 3.10.7.1 |--- Server -> Section 3.10.7.1 |--- Port -> Section 3.10.7.1 |--- Account -> Section 3.10.7.1 |--- Username -> Section 3.10.7.1 |--- Password -> Section 3.10.7.1 |--- FTP path -> Section 3.10.7.1 |--- HTTPS base URL -> Section 3.10.7.1 |--- Filename -> Section 3.10.7.1 | | |--- Screensaver3 |--- Use default -> Section 3.10.8.1 |--- Download method -> Section 3.10.8.1 |--- Server -> Section 3.10.8.1 |--- Port -> Section 3.10.8.1 |--- Account -> Section 3.10.8.1 |--- Username -> Section 3.10.8.1 |--- Password -> Section 3.10.8.1 |--- FTP path -> Section 3.10.8.1 |--- HTTPS base URL -> Section 3.10.8.1 |--- Filename -> Section 3.10.8.1 | | |--- Java midlets7 |--- Use default |--- Download method |--- Server |--- Port |--- Account |--- Username |--- Password |--- FTP path |--- HTTPS base URL |--- Filename | | |--- HPT dongle | | |--- Use default | | |--- Download method | | |--- Server | | |--- Port | | |--- Account | | |--- Username | | |--- Password | | |--- FTP path | | |--- HTTPS base URL | | |--- Filename | |--- Local Functions | | |--- Directory Settings3 |--- LDAP server address -> Section 3.11.1 |--- LDAP server port -> Section 3.11.1 |--- LDAP authenticate -> Section 3.11.1 |--- LDAP user name -> Section 3.11.1 |--- LDAP password -> Section 3.11.1 | | |--- Locality |--- Canonical settings

Technical Reference · Menus

Page 245 of the Siemens 8000 user manual — 5.1.2 Local Phone Menu
Seite 245 · Zum Vergrößern klicken
Seite 245

referenz.fm

Menu Further information ...

|--- Local country code -> Section 3.8.1 |--- National prefix digit -> Section 3.8.1 |--- Local national code -> Section 3.8.1 |--- Minimum local number length -> Section 3.8.1 |--- Local enterprise node -> Section 3.8.1 |--- PSTN access code -> Section 3.8.1 |--- International access code -> Section 3.8.1 |--- Operator code -> Section 3.8.1 |--- Emergency number -> Section 3.8.1 |--- Initial digits -> Section 3.8.1 |--- Canonical lookup |--- Local code 1 -> Section 3.8.2 |--- International code 1 -> Section 3.8.2 |--- Local code 2 -> Section 3.8.2 |--- International code 2 -> Section 3.8.2 |--- Local code 3 -> Section 3.8.2 |--- International code 3 -> Section 3.8.2 |--- Local code 4 -> Section 3.8.2 |--- International code 4 -> Section 3.8.2 |--- Local code 5 -> Section 3.8.2 |--- International code 5 -> Section 3.8.2 |--- Canonical dial |--- Internal numbers -> Section 3.8.1 |--- External numbers -> Section 3.8.1 |--- External access code -> Section 3.8.1 |--- International gateway -> Section 3.8.1 | | |--- Pixel saver -> Section 3.5.3 | |--- Date and Time | | |--- Time source -> Section 3.5.4.1 |--- SNTP IP address -> Section 3.5.4.1 |--- Timezone offset -> Section 3.5.4.1 | | |--- Daylight saving -> Section 3.5.4.1 |--- Daylight saving -> Section 3.5.4.1 |--- Difference (mins) -> Section 3.5.4.1 |--- Auto DST -> Section 3.5.4.1 |--- DST zone -> Section 3.5.4.1 | |--- Speech | | |--- Codec Preferences |--- Silence suppression -> Section 3.12.2 |--- Packet size -> Section 3.12.2 |--- G.711 -> Section 3.12.2 |--- G.729 -> Section 3.12.2 |--- G.722 -> Section 3.12.2 | | |--- Audio Settings | | |--- Disable microphone -> Section 3.12.3 | | |--- Disable loudspeech -> Section 3.12.3 | |--- General Information | | |--- MAC address -> Section 3.17.1 | | |--- Software version -> Section 3.17.1 | | |--- Last restart -> Section 3.17.1 | |--- Password

Technical Reference · Menus

Page 246 of the Siemens 8000 user manual — 5.1.2 Local Phone Menu
Seite 246 · Zum Vergrößern klicken
Seite 246

referenz.fm

Menu Further information ...

| | |--- Admin -> Section 3.14 | | |--- Confirm admin -> Section 3.14 | | |--- User -> Section 3.14 | | |--- Confirm user -> Section 3.14 | |--- Mobility | | |--- Unauthorized logoff trap -> Section 3.9 | | |--- Logoff trap delay -> Section 3.9 | | |--- Timer med priority -> Section 3.9 | | |--- Mobility feature -> Section 3.9 | | |--- Managed profile | | |--- Error count local | | |--- Error count remote | |--- Maintenance | |--- Factory reset -> Section 3.16 | |--- Disable HPT -> Section 3.17.10 | |--- Remote trace4 | |--- Remote trace status -> Section 3.17.9 | |--- Remote ip -> Section 3.17.9 | |--- Remote port -> Section 3.17.9 1 OpenStage 60/80 V1R3.x upwards only. 2 OpenStage 60/80 V1R2.x only. In V1R3.x, Bluetooth can be enabled or disabled only via WBM or DLS. 3 OpenStage 60/80 only. 4 V1R3.x upwards only. 5 OpenStage 40/60/80 only. 6 V1R4.x upwards. 7 Not available yet.

Technical Reference · Menus

Page 247 of the Siemens 8000 user manual — DHCP
Seite 247 · Zum Vergrößern klicken
Seite 247

bkglos.fm

Nur für den internen Gebrauch Glossary

Glossary X

A

Address of Record (AoR)

A ->SIP ->URI that represents the "public address" of a SIP user resp. a phone or line. The format is similar to an E-mail address: "username@hostname". (for a definition, see RFC 3261)

ADPCM

Adaptive Differential Pulse Code Modulation. A compressed encoding method for audio signals which are to be transmitted by a low bandwidth. As opposed to regular ->PCM, a sample is coded as the difference between its predicted value and its real value. As this difference is usually smaller than the real, absolute value itself, a lesser number of bits can be used to encode it.

CSTA

Computer Supported Telecommunications Applications. An abstraction layer for telecom munications applications allowing for the interaction of ->CTI computer applications with te lephony devices and networks.

CTI

Computer Telephony Integration. This term denotes the interaction of computer applica tions with telephony devices and networks.

D

DFT

Digital Feature Telephone. A phone with no line keys.

DHCP

Dynamic Host Configuration Protocol. Allows for the automatic configuration of network endpoints, like IP Phones and IP Clients.

Differentiated Services. Specifies a layer 3 mechanism for classifying and managing net work traffic and providing quality of service (->QoS) guarantees on ->IP networks. DiffServ can be used to provide low-latency, guaranteed service for e. g. voice or video communi cation.

A31003-O1010-M100-10-76A9, 13/06/2008 HiPath 8000 - OpenStage Family, Administration Manual X-1

DiffServ

Page 248 of the Siemens 8000 user manual — G.729
Seite 248 · Zum Vergrößern klicken
Seite 248

bkglos.fm

Glossary Nur für den internen Gebrauch

DLS

The Deployment Service (DLS) is a HiPath management application for the administration of workpoints, i. e. IP Phones and IP Clients, in both HiPath- and non-HiPath networks.

DNS

Domain Name System. Performs the translation of network domain names and computer hostnames to ->IP addresses.

DTMF

Dual Tone Multi Frequency. A means of signaling between a phone and e. g. a voicemail facility. The signals can be transmitted either in-band, i. e. within the speech band, or out- band, i. e. in a separate signaling channel.

E

EAP

Extensible Authentication Protocol. An authentication framework that is frequently used in WLAN networks. It is defined in RFC 3748.

F

FTP

File Transfer Protocol. Used for transferring files in networks, e. g., to update telephone software.

G

G.711

ITU-T standard for audio encoding, used in ISDN and ->VoIP. It requires a 64 kBit/s band width.

G.722

ITU-T standard for audio encoding using split band ->ADPCM. The audio bandwidth is 7 kHz at a sampling rate of 16 kHz. There are several transfer rates ranging from 32 to 64 kBit/s, which correspond to different compression degrees. The voice quality is very good.

G.729

ITU-T standard for audio encoding with low bandwidth requirements, mostly used in VoIP. The standard bitrate is 8 kBit/s. Music or tones such as ->DTMF or fax tones cannot be transported reliably with this codec.

Mediation components between two different network types, e. g., ->IP network and ISDN network.

A31003-O1010-M100-10-76A9, 13/06/2008 X-2 HiPath 8000 - OpenStage Family, Administration Manual

Gateway

Page 249 of the Siemens 8000 user manual — LDAP
Seite 249 · Zum Vergrößern klicken
Seite 249

bkglos.fm

Nur für den internen Gebrauch Glossary

GUI

Graphical User Interface.

H

HTTP

Hypertext Transfer Protocol. A standard protocol for data transfer in ->IP networks.

IP

Internet Protocol. A data-oriented network layer protocol used for transferring data across a packet-switched internetwork. Within this network layer, reliability is not guaranteed.

The unique address of a terminal device in the network. It consists of four number blocks of 0 to 255 each, separated by a point.

J

Latency fluctuations in the data transmission resulting in distorted sound.

LAN

Local Area Network. A computer network covering a local area, like an office, or group of buildings.

2nd layer (Data Link Layer) of the 7-layer OSI model for describing data transmission inter faces.

3rd layer (Network Layer) of the 7-layer OSI model for describing the data transmission in terfaces.

LCD

Liquid Crystal Display. Display of numbers, text or graphics with the help of liquid crystal technology.

LDAP

Lightweight Directory Access Protocol. Simplified protocol for accessing standardized di rectory systems, e.g., a company telephone directory.

A31003-O1010-M100-10-76A9, 13/06/2008 HiPath 8000 - OpenStage Family, Administration Manual X-3

Show 4 more labels / short text on this page
IP address · Jitter · Layer 2 · Layer 3
Page 250 of the Siemens 8000 user manual — PSTN
Seite 250 · Zum Vergrößern klicken
Seite 250

bkglos.fm

Glossary Nur für den internen Gebrauch

LED

Light Emitting Diode. Cold light illumination in different colours at low power consumption.

M

Media Access Control address. Unique 48-bit identifier attached to network adapters.

MDI-X

Media Dependent Interface crossover (X). The send and receive pins are inverted. This MDI allows the connection of two endpoints without using a crossover cable. When Auto MDI-X is available, the MDI can switch between regular MDI and MDI-X automatically, de pending on the connected device.

MIB

Management Information Base. A type of database used to manage the devices in a com munications network.

MWI

Message Waiting Indicator. A signal, typically a LED, to notify the user that new mailbox messages have arrived.

P

PBX

Private Branch Exchange. Private telephone system that connects the internal devices to each other and to the ISDN network.

PCM

Pulse Code Modulation. A digital representation of an analog signal, e. g. audio data, which consists of quantized samples taken in regular time intervals.

PING

Packet Internet Gro(u)per. A program to test whether a connection can be made to a de fined IP target. Data is sent to the target and returned from there during the test.

Power over Ethernet. The IEEE 802.3af standard specifies how to supply power to compli ant devices over Ethernet cabling (10/100Base-T).

Ports are used in ->IP networks to permit several communication connections simulta neously. Different services often have different port numbers.

PSTN

Public Switched Telephone Network. The network of the world's public circuit-switched telephone networks.

A31003-O1010-M100-10-76A9, 13/06/2008 X-4 HiPath 8000 - OpenStage Family, Administration Manual

MAC Address · PoE · Port

Page 251 of the Siemens 8000 user manual — SIP
Seite 251 · Zum Vergrößern klicken
Seite 251

bkglos.fm

Nur für den internen Gebrauch Glossary

Q

Quality of Service. The term refers to control mechanisms that can provide different priority to different users or data flows, or guarantee a certain level of performance to a data flow in accordance with requests from the application program. The OpenStage phone allows for the setting of QoS parameters on layer 2 and layer 3 (DiffServ).

QDC

QoS Data Collection. A HiPath IP service that is used to collect data from HiPath products in order to analyze their voice and network quality.

QCU

Quality of Service Data Collection Unit. A service tool that collects QoS report data from IP endpoints.

Quality of Service. Provides different priority to different users or data flows, or guarantee a certain level of performance to a data flow.

R

RAM

Random Access Memory. Memory with read / write access.

ROM

Read Only Memory. Memory with read only access.

RTCP

Realtime Transport Control Protocol. Controls the ->RTP stream and provides information about the status of the transmission, like QoS parameters.

RTP

Realtime Transport Protocol. This application layer protocol has been designed for audio and video communication. Typically, the underlying protocol is ->UDP.

S

SDP

Session Description Protocol. Describes and initiates multimedia sessions, like web con ferences. The informations provided by SDP can be processed by ->SIP.

SIP

Session Initiation Protocol. Signaling protocol for initialising and controlling sessions, used e. g. for ->VoIP calls.

A31003-O1010-M100-10-76A9, 13/06/2008 HiPath 8000 - OpenStage Family, Administration Manual X-5

QoS · QoS

Page 252 of the Siemens 8000 user manual — URL
Seite 252 · Zum Vergrößern klicken
Seite 252

bkglos.fm

Glossary Nur für den internen Gebrauch

SNMP

Simple Network Management Protocol. Used for monitoring, controlling, and administra tion of network and network devices.

SNTP

Simple Network Time Protocol. Used to synchronize the time of a terminal device with a timeserver.

To discern the network part from the host part of an ->IP address, a device performs an AND operation on the IP address and the network mask. The network classes A, B, and C each have a subnet mask that demasks the relevant bits: 255.0.0.0 for Class A, 255.255.0.0 for Class B and 255.255.255.0 for Class C. In a Class C network, for instance, 254 IP addresses are available.

Network device that connects multiple network segments and terminal devices. The for warding of data packets is based on ->MAC Addresses: data targeted to a specific device is directed to the switch port that device is attached to.

T

TCP

Transfer Control Protocol. The protocol belongs to the transport layer and establishes a connection between two entities on the application layer. It guarantees reliable and in-order delivery of data from sender to receiver, as opposed to ->UDP.

TLS

Transport Layer Security. Ensures privacy between communicating applications. Typically, the server is authenticated, but mutual authentication is also possible.

U

UDP

User Datagram Protocol. A minimal message-oriented transport layer protocol used espe cially in streaming media applications such as ->VoIP. Reliability and order of packet deliv ery are not guaranteed, as opposed to ->TCP, but ->UDP is faster and more efficient.

URI

Uniform Resource Identifier. A compact string of characters used to identify or name a re source.

URL

Uniform Resource Locator. A special type of ->URI which provides means of acting upon or obtaining a representation of the resource by describing its primary access mechanism or network location.

A31003-O1010-M100-10-76A9, 13/06/2008 X-6 HiPath 8000 - OpenStage Family, Administration Manual

Subnet Mask · Switch

Page 253 of the Siemens 8000 user manual — WSP
Seite 253 · Zum Vergrößern klicken
Seite 253

bkglos.fm

Nur für den internen Gebrauch Glossary

VLAN

Virtual Local Area Network. A method of creating several independent logical networks within a physical network. For example, an existing network can be separated into a data and a voice VLAN.

Voice over IP. A term for the protocols and technologies enabling the routing of voice con versations over the internet or through any other ->IP-based network

W

WAP

Wireless Application Protocol. A collection of protocols and technologies aiming at en abling access to internet applications for wireless devices. WAP can also be used by the OpenStage phone.

WBM

Web Based Management. A web interface which enables configuration of the device using a standard web browser.

WML

Wireless Markup Language. An XML-based markup language which supports text, graphics, hyperlinks and forms on a ->WAP-browser.

WSP

Wireless Session Protocol. The protocol is a part of the ->WAP specification. Its task is to establish a session between the terminal device and the WAP gateway.

A31003-O1010-M100-10-76A9, 13/06/2008 HiPath 8000 - OpenStage Family, Administration Manual X-7

VoIP

Page 254 of the Siemens 8000 user manual — 5.1.2 Local Phone Menu
Seite 254 · Zum Vergrößern klicken
Seite 254

bkglos.fm

Glossary Nur für den internen Gebrauch

A31003-O1010-M100-10-76A9, 13/06/2008 X-8 HiPath 8000 - OpenStage Family, Administration Manual

Page 255 of the Siemens 8000 user manual — Index Z
Seite 255 · Zum Vergrößern klicken
Seite 255

OperaAdminSIX.fm

Nur für den internen Gebrauch Index

Index Z

A Address of Record (AoR) 6-1 Administration Menu (Local Menu) 3-1, 3-2 Application Keys 1-4, 1-6 Audio Keys 1-4, 1-5

G Graphics Display 1-4 Group Pickup 3-47

H Handset 1-4, 1-6 HiPath 8000 (Registration) 2-25

I Initial Digits 3-73 Internal Numbers 3-73 International Code (Local Country Code) 3-

C Call Display 1-4, 1-5 Call Transfer 3-50 Callback 3-52 Canonical Dial Lookup 3-76 Canonical Dialing 3-72 Conference (System based) 3-54 CSTA 3-56, 6-1 CTI 6-1

72 International Gateway Code 3-74 International Prefix (International Access Co-

Address 2-10 Address (Manual Configuration) 3-15 IP 6-3 Specific Routing 3-17

D Date and Time (SNTP) 2-10, 3-30 Daylight Saving 3-30 Default Route 3-16 DFT (Digital Feature Telephone) 6-1 DHCP 3-13, 6-1 Diffserv 3-11 DLS (Deployment Service) 1-7, 3-20, 6-2 DNS 3-18, 6-2 DNS Domain Name 3-18 DST Zone (Daylight Saving Time Zone) 3-30

K Keypad 1-4, 1-5, 1-6

L LAN 6-3 LAN Port 3-5 LDAP 6-3 LDAP Template (Download) 3-91 Line Key Configuration 3-60 Local Area Code (Local National Code) 3-72 Local Country Code (International Code) 3-

E Emergency Number 3-27, 3-72 External Access Code 3-73 External Numbers 3-73

72 Local Enterprise Number 3-72 Local National Code (Local Area Code) 3-72 Logo (Create) 4-5 Logo (Download) 3-94

F FTP Settings 3-79 Function Keys 1-4, 1-5, 1-6

M MAC Address 6-4

A31003-O1010-M100-10-76A9, 13/06/2008 HiPath 8000 - OpenStage Family, Administration Manual Z-1

B Bluetooth 3-149 · de) 3-72 IP

Page 256 of the Siemens 8000 user manual — R RTP 6-5
Seite 256 · Zum Vergrößern klicken
Seite 256

OperaAdminSIX.fm

Index Nur für den internen Gebrauch

MDI-X 3-5, 6-4 MIB 6-4 Multiline / Keyset 3-60 Music on Hold (Download) 3-84 MWI 3-53 MWI (Message Waiting Indicator) 6-4

T TCP 6-6 Terminal Number 2-8, 3-25 Timeout (Not used) 3-58 Timezone Offset 2-10, 3-30 TLS 6-6 TouchGuide 1-4, 1-6 TouchSlider 1-4 Trunk Prefix (National Prefix) 3-72

N National Prefix (Trunk Prefix) 3-72

O Operator Code 3-72 Outbound Proxy 3-38

U uaCSTA 3-56 UDP 6-6

P Password, change 3-118 Password, enter 3-1 PBX 6-4 Phone Software (Download) 3-81 Picture Clips (Download) 3-88 PoE (Power over Ethernet) 2-5, 6-4 Program Keys 1-4, 1-5 PSTN 6-4 PSTN Aaccess Code 3-72

V Vendor Class (DHCP) 2-12 VLAN 2-11, 3-7 Voice Mail Number 3-27

W WBM (Web Based Management) 1-6, 2-7, 6-

Q QCU 3-22 QoS 3-10

R RTP 6-5

S Screensaver (Download) 3-97 SIP

Registration 3-35 Server Addresses 3-33 Server Ports 3-34 Session Timer 3-40 Transport Protocol 3-39 SNMP 3-21, 6-6 Subnet Mask 2-10 Subnet Mask (Manual Configuration) 3-15 Survivability 3-42

A31003-O1010-M100-10-76A9, 13/06/2008 Z-2 HiPath 8000 - OpenStage Family, Administration Manual

Page 257 of the Siemens 8000 user manual — 5.1.2 Local Phone Menu
Seite 257 · Zum Vergrößern klicken
Seite 257

OperaAdminSIX.fm

Nur für den internen Gebrauch Index

A31003-O1010-M100-10-76A9, 13/06/2008 HiPath 8000 - OpenStage Family, Administration Manual Z-3

Page 258 of the Siemens 8000 user manual — 5.1.2 Local Phone Menu
Seite 258 · Zum Vergrößern klicken
Seite 258

OperaAdminSIX.fm

Index Nur für den internen Gebrauch

A31003-O1010-M100-10-76A9, 13/06/2008 Z-4 HiPath 8000 - OpenStage Family, Administration Manual

Page 259 of the Siemens 8000 user manual — 5.1.2 Local Phone Menu
Seite 259 · Zum Vergrößern klicken
Seite 259
Page 259 of the Siemens 8000 user manual — 5.1.2 Local Phone Menu
Page 260 of the Siemens 8000 user manual — Communication for the open minded
Seite 260 · Zum Vergrößern klicken
Seite 260

Copyright © Siemens Enterprise Communications GmbH & Co. KG 13/06/2008 Hofmannstr. 51, D-81359 München

Reference No.: A31003-O1010-M100-10-76A9

The information provided in this document contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Subject to availability. Right of modificati- on reserved. The trademarks used are owned by Siemens Enterprise Communications GmbH & Co. KG or their respective owners.

Communication for the open minded

Siemens Enterprise Communications www.siemens.com/open

Quellen

Referenzen & Links

In dieser Anleitung genannte Seiten – Hersteller, Support und Downloads.

Frage zu Siemens 8000 stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Siemens 8000

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Siemens 8000 PDF-Anleitung

260 Seiten·4.6 MB·Telefon·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…