Benutzeranleitung / Produktwartung AC880 des Produzenten Sharp
Zur Seite of 19
OPERATION & MAINTENANCE MANUAL AC880 Refrigerant Handling System Manual P/N 035- 80749-00.
TA BLE OF CONTENTS A C880 B e f o r e U s i n g t h e A C 8 8 0 ..................... 2 S a f e t y P r e c a u t i o n s .......................... 2 U s i n g t h e A C 8 8 0 ........................... 3 S e t u p ..................................
Page 2 BEFORE USING T HE A C880 Check for any shipping damage. Place a claim with carrier if damage is disc overed. DO NOT USE A DAMA GED UNIT. Complete and retur n the Warr anty Card to ac tivate te chnical s upport ser vice and w arra nty coverage.
Page 3 USIN G T HE A C880 Note: The purpose of this discus sio n is to fa m iliarize the user with t he features and functions of the AC880 Refrigerant Handling Station.
Page 4 SETUP 1 Low Pressure Gauge 7 Oil Charge - High Side 13 Fill Port 2 Keypad 8 Red Hose - High Side 14 Refrigerant Cylinder 3 Power Switch 9 Blue Hose - Low Side 15 Y ellow Hose w/Anti-blowback 4 .
Page 5 N N N N N N N N N N N N EXTREMELY IMPOR TA NT N N N N N N N N N N N N Always connect Y ellow Hose (15) to Cylinder (14) first and then connect other end of hose with anti-blowback valve to Fill Port (13) on AC880. WEIGHT = XX.X LB AUTOMA TIC ? # >>>> WEIGHT = XX.
Page 6 WEIGHT = XX.X LB AUTOMA TIC ? # > WEIGHT = XX.X LB RECYCL E ? # ENTER RECYCL E HOLD TIME XX MI N # >< ENTER CHECK HO SES START ? # ENTER WEIGHT = XX.
Page 7 DRA IN RECOVERED OIL Oil is separated from the recove re d refrigerant and MUST be removed following EACH Recover/ Recycle procedure to determine the amount (if any ) necessary to add into the A/C Sy stem as follows: Note: The AC880 must be connected to pow er source.
Page 8 WEIGHT = XX.X LB AUTOMA TIC ? # >> WEIGHT = XX.X LB VACUUM ? # ENTER * A/C HAS PR ESSURE GO TO RECY CLE # ENTER ENTER VA CUUM TIME XX MI N # >< ENTER PEFORM L EAK TEST ? Y/N # < .
Page 9 WEIGHT = XX.X LB AUTOMA TIC ? # >>> WEIGHT = XX.X LB CHARGE ? # ENTER ENTER CH ARGE AMOUNT = XX.X LB # >< ENTER * LOW LEVEL , GO T O FILL CY LIND ER # ENTER CHECK H IGH- LOW CHARGE S WITCH # ENTER WEIGHT = XX.X LB CHARGI NG CHARG E COMP LETE EVAC HOS ES # ENTER CHA RGE 1.
Page 10 WEIGHT = XX.X LB AUTOMA TIC ? # ENTER RECYCL E HOLD TIME XX MI N # >< ENTER ENTER VA CUUM TIME XX MI N # >< ENTER PEFORM L EAK TEST ? Y/N # < ENTER ADD OIL ? Y/N # < ENTER ENTER CH ARGE AMOUNT = XX.
Page 11 WEIGHT = XX.X LB COMPRE SSOR OFF * HIGH PR ESSU RE SEE MAN UAL ** CYLIND ER FULL GO TO CHAR GE # TIME LE FT=X X MIN PUMP ON PUMP OFF XX MIN CONTIN UE ? # ENTER ADD OIL NO W CONTIN UE ? # ENTER WEIGHT = XX.
Page 12 WEIGHT = XX.X LB AUTOMA TIC ? # >>>>> ENTER WEIGHT = XX.X LB SETUP ? # ENTER FILTER H OURS= XX.X HOU RS > TOTAL R ECYC LED= XXXX.X K G > TOTAL C HARG ED= XXXX.X K G > A CCESS ST ORED DA TA 1. Set up the AC880 and t urn the Main Power Switch ON.
Page 13 WEIGHT = XX.X LB AUTOMA TIC ? # >>>>> ENTER WEIGHT = XX.X LB SETUP ? # Calibration Switch WEIGHT = XX.X LB CHARGI NG > OVER CH ARGE AMOUNT = X.XX KG # >< ENTER SET OVER CHA RGE A MOUNT 1. Remove the front panel of the AC880.
Page 14 SCHEDULED MA INT ENA NCE DA IL Y... Che ck the oil le vel in t he Vacuum Pump while the pump is running. The Vacuum Pum p Oil Level Sight Glass is visible thr ough a hole in the Lower Rear Panel of the AC880. The oil l evel s hould be at the “half-way” point of the glass.
Page 15 PA RT S IDENTIFICA T ION P/N DESCRIPTION 1 360-81555-00 Manifold Assy 880 120V 2 024-80037-00 Contactor ½ HP (120V) 3NO/1N C 3 024-80066-00 Rocker Swi tch SPDT Visired N on-lig hted 4 360-803.
Page 16 PA RT S IDENTIFICA T ION P/N DESCRIPTION 1 026-80077-00 Combo Filter 3/8 Fl are (Long) 2 360-81192-00 Compressor Inlet Tube Assy 3 360-81197-00 Accumulator Assy 4 360-81356-01 Compressor Assy .
Page 17 PA RT S IDENTIFICA T ION P/N DESCRIPTION 1 024-80040-00 Rocker Swi tch SPDT (on-on) Amber 125V 2 024-80060-01 Circuit Boar d 120V 3 026-80065-03 Gauge 30"-120 Psig 1/4 MFL 3.
Page 18 T ROUBLESHOOTING FILL CYLINDER PROCEDURE 1) The cy linder of new refrigerant should be at ambient temperature or great er for best performance of the Fill Cylinder procedure. Make sure the cy linder was not recently moved from an air-conditi oned storage ro om to a w arm w ork a rea .
Ein wichtiger Punkt beim Kauf des Geräts Sharp AC880 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Sharp AC880 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Sharp AC880 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Sharp AC880 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Sharp AC880 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Sharp AC880 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Sharp AC880 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Sharp AC880. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Sharp AC880 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.