Benutzeranleitung / Produktwartung 6000 des Produzenten Scytek electronic
Zur Seite of 36
V I S I O N G U A R D 6000 VEHICLE SECURITY SYSTEM WITH BUILT-IN CAMERA AND A REMOTE START PRODUCT MANUAL.
L i m i t e d L i f e t i m e W a r r a n t y This vehicle security system is warranted to the original purchaser , to be free from defects in material and workmanship.
1. About Y our System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 1 2. Remote T ransmitters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
The ScyT ek VisionGuard 6000 is a combination vehicle security and remote starting system f eaturing a built- in "ScyNet Network P ort" that allows direct connection of optional accessory modules and a PC interface offering expanded system oper ation.
Standard Remote Transmitter Description The VisionGuard 6000 is compatible with the optional 5-button R emote T ransmitters used to control system operations. Note : Using the optional PC or P ocket PC interface with the network softw are, it is possible to reconfigure the functionality of the tr ansmitter buttons.
Adding/Replacing Transmitters T o replace lost or stolen transmit ters or to add additional transmitters into the system, ha ve all desired transmit ters ready and follow the steps below . Note : Up to 4 transmit ters can be programmed to oper ate the system.
Page 4 - VisionGuard 6000 True Color 2-way Camera Ready Remote Transmitter Description The VisionGuard 6000 True Color 2-way LCD remote transmitter, is offering increased range and confirmation of any activated features. Button 1 Arms the system. Button 1 also locks the doors when the system is in Valet Mode.
VisionGuard 6000 - Page 5 4. Turn off the ignition key. 5. Repeat steps 1-4 to add an additional 2-way transmitter. System Confirmation The 2-wa y transmitter's confirmation f eature allows the current vehicle status to be displayed at any time. T o display system status: Press and hold Button 4 until the display shows CON.
Page 6 - VisionGuard 6000 C a m e r a F e a t u r e s.
VisionGuard 6000 - Page 7.
Page 8 - VisionGuard 6000 Remote Arming The system monitors 6 independent areas ( zones ) while armed: doors, hood, trunk, shock sensor , optional sensor input, and the network port for future expansion. T o Arm the System: 1. T urn off the ignition. 2.
VisionGuard 6000 - Page 9 Tamper Alert If the system was triggered while awa y , the LED will flash to indicate which zone triggered the system after disarming and turning on the ignition.
Page 10 - VisionGuard 6000 Panic Mode In the event of an emergency the tr ansmitter’s remote P anic feature can be used to instantly trigger the alarm. T o activate the P anic Mode: 1. Press and hold Button 1 for 3 seconds. · The alarm will sound. · The parking lights will flash.
VisionGuard 6000 - Page 11 T o set the Emergency Override Code: 1. T urn on ignition. 2. Within 5 seconds, press the valet switch 5 times. · The siren will provide one long chirp, indicating that y ou have entered Progr amming. 3. Press the valet switch 4 times.
Page 12 - VisionGuard 6000 Remote Starting T o Remote Start the S ystem: 1. Be sure the system is not in V alet Mode. 2. Press and hold Button 4 for three seconds. · The parking lights will flash 4 times and turn on. · The Siren will chirp 4 times. · The engine will start and run for the dur ation of its programmed Run Time.
VisionGuard 6000 - Page 13 Turbo Timer Feature The T urbo Timer feature allows vehicles with turbocharged engines to remain running after the ignition key is removed, f or proper cool-down of the turbocharger . The T urbo Timer feature requires connection to the vehicle’ s parking brake wire.
Page 14 - VisionGuard 6000 E x t e n d e d F e a t u r e s Ignition Door Locking F or added safety , the Ignition Door Locking feature allows v ehicles equipped with power door lock systems to automatically lock the doors when the ignition is turned on.
VisionGuard 6000 - Page 15 1. Thoroughly read and become familiar with the installation instructions bef ore beginning the installation. 2. R eview system contents: Main Unit T wo 5-Button Remote T ra.
Page 16 - VisionGuard 6000 Mounting the Control Unit The control unit must only be mounted in the interior of the vehicle. Do not mount the main unit in the engine compartment.
VisionGuard 6000 - Page 17 S y s t e m W i r i n g 6-Pin Starter Harness Pin 1 RED WIRE A : Main Power Input A (+). Connect to the battery or constant power wire at the ignition switch with a minimum 25 Amp supply . R emo v e the fuse until the installation is complete and all wiring is check ed.
Page 18 - VisionGuard 6000 when the door is open. This type of door circuit is usually found on F ord vehicles. Pin 12 GREEN WIRE : Negativ e Door Input (-). Connect to the door switch circuit wire that shows ground when the door is open. Pin 13 WHITE/BLACK WIRE : Hood Pin Input (-).
VisionGuard 6000 - Page 19 Jumper Selection Carefully separ ate the top and bottom halves of the main unit case. Once the cov er is removed, the parking light polarity jumper will be visible next to the parking light relay . Set the jumper for the correct polarit y output as described below , then reassembly the main unit case.
Page 20 - VisionGuard 6000 Entering System Programming This system is compatible with both the optional LCD tr ansmitter or the standard AM transmit ter , all system programming can be perf ormed using either one. T o enter System Progr amming: 1. T urn on ignition.
VisionGuard 6000 - Page 21 5. Ignition Door Unlocking. Selects whether or not the system automatically unlocks the doors when the ignition is turned off . The Ignition Door Locking f eature may be programmed to unlock all doors or the driver’ s door only .
Page 22 - VisionGuard 6000 8. Passive Door Locking. Selects whether or not the system will automatically lock the doors during P assive Arming and Auto Rearming mode. 9. Passive Arming Entry Delay. When selected, the siren will chirp for 10 seconds before sounding if a door is opened.
VisionGuard 6000 - Page 23 Diesel Engine. Sets the engine type f or Diesel and monitors the glow plug input to make sure the glow plugs are warm before cr anking the starter . If the glow plug wire is not connected, the built-in timer waits 15 seconds before automatically cr anking the starter .
Page 24 - VisionGuard 6000 W i r i n g D i a g r a m s TO POSITIVE DOME LIGHT +12V Black/White (-) DOME LIGHT OUTPUT TO NEGATIVE DOME LIGHT +12V Black/White (-) DOME LIGHT OUTPUT P ositive Dome Light .
VisionGuard 6000 - Page 25 Negative T rigger P ositive T rigger R everse P olarity V acuum Adding Actuators F ollow the diagrams below for connecting basic door lock systems. F or T wo Stage door lock systems (separately unlocks driv er and passenger doors) see following pages.
Page 26 - VisionGuard 6000 T w o S t a g e D o o r L o c k D i a g r a m s T wo Stage Negative T rigger T wo Stage P ositive T rigger The VisionGuard 6000 is equipped with a dedicated P assenger Unlock output allowing T wo Stage Door Lock operation. When connected as shown below , disarming the system will unlock only the driver’ s door .
VisionGuard 6000 - Page 27 T w o S t a g e D o o r L o c k Diagrams c o n t ’ d T wo Stage R everse P olarity T wo Stage Adding Actuators.
Page 28 - VisionGuard 6000 FCC ID: OARRXAM2000 This device complies with P art 15 of FCC Rules. Operation is subject to the f ollowing two conditions: 1) This device may not cause harmf ul interference.
VisionGuard 6000 - Page 29 S t a r t e r D i a g n o s t i c s Starter doesn’t start and Side Lights flash: 3 Times - Engine RPM not detected Hood T rigger is active 4 Times - Brak e T rigger is active 5 Times - Unit is in V alet (service) mode, and start is disabled.
Page 30 - VisionGuard 6000.
VisionGuard 6000 - Page 31.
ScyTek Electronics 11627 Cantara Street North Hollywood, CA 91605 © ScyT ek Electronics 2005 VisionGuard 6000 r3 11/05 W i r i n g D i a g r a m ScyNet Blue Star t (-) Green Emer gency brak e(-) Ante.
Ein wichtiger Punkt beim Kauf des Geräts Scytek electronic 6000 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Scytek electronic 6000 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Scytek electronic 6000 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Scytek electronic 6000 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Scytek electronic 6000 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Scytek electronic 6000 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Scytek electronic 6000 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Scytek electronic 6000. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Scytek electronic 6000 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.