IP Office Installation Manual 40DHB0002USCL – Issue 7 (09/25/2002).
Page 2 - Contents Page 2 - Contents IP Office Installation Manual Contents Introduc tion ......................................................................................................................................................5 General ..
Contents - Page 3 Contents (Cont.) Expansion Modules .......................................................................................................................................27 IP400 Digital Terminal 16/30 ...............................
Page 4 - Contents Contents (Cont.) Telephone Inst allation ...................................................................................................................................46 Checking Telephones ......................................
Introduction General - Page 5 Introduction General This manual covers the installation of your Avaya IP Office equipped with release Level 1.0+ software. It is intended for use by installers and maintainers who have successfully completed the appropriate IP Office training courses.
Page 6 - Lithium Batteries Safety and Homologation Statem ents Safety and Homologation Statements CE Mark The "CE" mark affixed to this equipment means that the unit complies with the 1999/5.
Safety and Homologation Statements Trunk Interface Modules - Page 7 Trunk Interface Modules ROW To ensue the validation of the approvals in ROW (i.e. EU, Hungary, Australia and New Zealand), only the .
Page 8 - Regulatory Instructions for Use Safety and Homologation Sta tements Regulatory Instructions for Use IP Office Operation in Australia Connection Connection of IP400 Office products must be via a Line Isolation Unit with a telecommunications compliance label.
Safety and Homologation Sta tements Regulatory Instructions for Us e - Page 9 IP Office Operation in EU 1. 999 and 112 calls must not be barred. Doing so will invalidate the approval. 2. All connections at the MDF shall be identifiable by suitable labeling.
Page 10 - General IP401 Compact Office Platform IP401 Compact Office Platform General The IP401 Compact Office system platform is supplied in two variants: IP401 Compact Office 2 supports: Two digital.
IP401 Compact Office Platform IP401 Comp act Office - Front View - Page 11 IP401 Compact Office - Front View D T P ort s 1- 4 G reen LED s - Ter m i nal connect ed Yel l ow LE D s – Stat us of I SD .
Page 12 - IP401 Compact Office - Rear View IP401 Compact Office Platform IP401 Compact Office - Rear View DC Power I/P Socket DTE Port WA N P o rt External O/P Socket USB Interface Socket Audio I/P Socket BRI Por ts Slot for VME Card AUDIO DTE EXT O/P WA N BRI 1 BRI 2 USB DC I/P - C + 24V DC 2A Vents Notes: 1.
IP401 Compact Office Platform IP401 Comp act Office - Rear View - Page 13 Typical Configuration Scenario: A customer requiring a voice and data solution for a warehousing facility remote from a regional office. Three administrators and two pickers staff the warehouse.
Page 14 - General IP403 Office Platform IP403 Office Platform General The IP403 Office system platform supports up to eight digital and two analog telephones. This can be expanded, by use of extension modules, to 100 extensions. Two variants are available and are equipped as follows: • DT ports - Support Avaya 2000 series telephones.
IP403 Office Platform IP403 Office - Front View - Page 15 IP403 Office - Front View Y ellow LEDs LEDs 1-3 = Expansi on Ports 1-3 status LEDs 4-7 = ISD N 1-4 status LED 8 = WAN status Green LEDs Termin.
Page 16 - IP403 Office - Rear View IP403 Office Platform IP403 Office - Rear View DC Power I/P Socket DTE Port WAN Port Slot A is normally blank, but ca n contain an ANAL OG Trunk Modu le Slot B can c.
IP403 Office Platform IP403 Office - Rear View - Page 17 Typical Configuration Scenario: A customer with sophisticated telephony requi rements, needing 30 exchange lines and 80 Display Terminals. This configuration provides support for 98 Avaya 20 series digital telephones (18 spare for growth) and a single Primary Rate ISDN connection.
Page 18 - General IP406 Office Platform IP406 Office Platform General The IP406 Office system platform supports up to 180 extensions. Connection to trunks is via any two of the following integral inte.
IP406 Office Platform IP406 Office - Front View - Page 19 IP406 Office - Front View Expansi on Port s 1 G r een St at us LED s C ascade S w i tch f or Port 8 I SDN Po r t s 1 G r een St at us LED s W .
Page 20 - IP406 Office - Rear View IP406 Office Platform IP406 Office - Rear View Slots A and B can contain any com bination of ANALOG or BRI or PR I Trunk Modules (Slot B must be used fir st) A udio .
IP406 Office Platform IP406 Office - Rear View - Page 21 Typical Configurations Scenario 1: A business requiring 60 analog Telephones and 8 Basic Rate ISDN lines (16 channels). The IP406 Office BRI 16 with two IP400 Office Phone 30 modules provides the required line and extension capacity.
Page 22 - General IP412 Office Platform IP412 Office Platform General The IP412 Office system platform supports up to 256 extensions. Connection to trunks is via a combination of any of the following .
IP412 Office Platform IP412 Office - Front View - Page 23 IP412 Office - Front View Expansi on Port s 1- 12 Green St at us LEDS Unit Sta t us LED R ed = A l i ve but not i ni t i at ed G r een = Runni.
Page 24 - IP412 Office - Rear View IP412 Office Platform IP412 Office - Rear View DC Power I/P Socket Expansion Ports 1-12 WAN Port Extern al O/P So cket A udio I/P Socket DTE Port Slot B AUDIO DTE WA.
IP412 Office Platform IP412 Office - Rear View - Page 25 Typical Configurations Scenario 1: A business requiring 180 Display Telephones and 96 Digital lines with 20 Analog lines for fall back purposes in the event of the T1 service failing.
Page 26 - IP412 Office - Rear View IP412 Office Platform Scenario 2: A Business requiring 90 IP hardphones, 90 IP softphones and 60 lines. This configuration illustrates an IP412 Office PRI 60 E1 fitted with two optional IP400 Office Voice Compression Module 20s.
Expansion Modules IP400 Digital Terminal 16/30 - Page 27 Expansion Modules Dependent upon configuration requirements, combinations of the following Expansion Modules are used with IP Office platforms.
Page 28 - IP400 Digital Stations 16/30 Expansion Modules IP400 Digital Stations 16/30 The IP400 Digital Station Expansion Module similar to the IP400 Digital Terminal Expansion Module (see page 27) with the exception that the Ports are labeled DS not DT and support Avaya 6400 or 4400 series telephones.
Expansion Modules IP400 So8 - Page 29 IP400 So8 The So8 Module is only applicable to countries that support the ETSI signaling protocol (see page 34). Front View Unit Sta t us LED R ed = A l i ve but .
Page 30 - IP400 WAN3 Expansion Modules IP400 WAN3 Front View Unit Sta t us LED R ed = A l i ve but not i ni t i at ed G r een = Runni ng O K W AN Li nk St at us 1 - 3 G r een LE D LAN Li nk O K LAN P .
Expansion Modules IP400 A nalog Trunk 16 - Page 31 IP400 Analog Trunk 16 Front View A nal og Tr unk Port s 1- 8 Uni t St a t us LED R ed = A l i ve but not i ni t i at ed G r een = Runni ng O K Anal o.
Page 32 - IP400 Office Systems Country Variants Country Variants The following are lists of the country variants fo r each IP400 Office platform, trunk module kits, Integral module kits and expansion modules. The PCS level for each module can be found on a label that is stuck to the base of each module.
Country Variants Integral Module Kits - Page 33 Integral Module Kits Voice Compression Modules (VCM) Variants Country SAP Code 5 Channel ALL 700185119 10 Channel ALL 700185127 20 Channel ALL 700185135.
Page 34 - IP Office Rack Mounting Kits Country Variants IP Office Rack Mounting Kits Rack Mounting Kit Variant Country SAP Code Rack Mounting kit for 19 inch racks ALL 700210800 Expansion Modules IP40.
Preparing for Installation Introduction - Page 35 Preparing for Installation Introduction This section reviews the requirements for installing an IP Office system. You must meet these requirements for the system to operat e safely and in the intended manner.
Page 36 - Env ironmental requirements Preparing for Installation Environmental requirements The planned location must meet the following requirements: – Check that the area is a well ventilated area, having a temperature range of 0 ° C to +40 ° C and a humidity range of 10% to 95% non-condensing.
Preparing for Installation Grounding - Page 37 Grounding Protective Ground A protective ground must be permanently fitted to IP400 Analog Trunk 16 modules (see page 31). Connection of this protective ground r equires the use of suitable tools and must be connected at both ends before connection is made to the telecommunications network.
Page 38 - Unpacking Installing a New System Installing a New System Unpacking Before proceeding with installation, ensure that you have read the notes covered in Preparing for Installation on page 35. Unpacking and checking : 1. Before unpacking check for any signs of dama g e that has occurred durin g transit.
Installing a New System Initial Assembly - Page 39 Installation of Integral Modules To install an integral module in a IP Office system, follow the pictorial instructions given below: Trunk Interface Modules (BRI/PRI/ANALOG4) For IP403 see page 16, for IP406 see page 20 and for IP412 see page 24.
Page 40 - Initial Assembly Installing a New System Voice Compression Module (VCM) An optional Voice Compression Module (see pages 14, 18 and 22) is fitted to an IP Office base unit as follows: Procedure 1. Remove the three fixing screws on the rear of cover.
Installing a New System Initial Assembly - Page 41 Dual Modem Module An optional Dual Modem Module (see pages 14, 18 and 22) is fitted to an IP Office base unit as follows: Procedure 1. Remove the three fixing screws on the rear of cover. 2. Turn the unit over and remove the four fixing screws from the base.
Page 42 - Initial Assembly Installing a New System Rack Mounting Assembly Instructions IP403, 406, 412 and expansion modules can be mounted in any standard 19" rack as follows: CAUTIONS: Elevated.
Installing a New System IP401 Compact Office Wall Mounting - Page 43 IP401 Compact Office Wall Mounting Bath variants of the IP401 Compact Office can be wall mounted. Four retaining slots (item n below) enable the IP401 unit to be mounted in any one of thr ee positions (two horizontal and one vertical) by using two No.
Page 44 - IP401 Expansion and Installation of Integral M odules Installing a New System IP401 Expansion and Installation of Integral Modules An IP401 Compact Office 2 can be expanded to an IP401 Compact Office 4. Either unit can be expanded with a WAN card.
Basic System Programming Introduction - Page 45 Basic System Programming Introduction This sections covers only the most basic aspects of system programming required to install an IP Office system. When first powered up, all IP Office systems will operate as a simple PBX.
Page 46 - Initial Programming Telephone Installation Initial Programming All the software used to configure and manage the IP Office system must be installed on your PC from the supplied Administration CD. With the initial assembly completed (see page 38) and your PC connected to the IP Office system, insert and run the Administration CD.
Telephone Installation Ch ecking Telephones - Page 47 Checking Telephones It is preferable to leave connection of telephones until after installation of other IP Office equipment and full system programming has been completed (i ncluding the set-up of directory numbers and names).
Page 48 - Wall Mounting 2000 Series Telephones Telephone Installation Wall Mounting 2000 Series Telephones Mounting brackets exist which clip onto the bas e on IP Office telephones. These brackets (two required per telephone) can be used to either raise the desk position of the telephone or for wall mounting.
Telephone Installation Wa ll Mounting 44/4600 & 6400 Series Telephones - Page 49 Wall Mounting 44/4600 & 6400 Series Telephones The following pictorial instructions, although for a 4600 telephone, provide a general overview on how to wall mount both series of telephones.
Page 50 - Checklist System Handov er System Handover Checklist Equipment : – Have all extensions been tested? – Have all exchange lines been tested? – Have all private wires been tested? – Is system programming in line with the customer specification? E.
Technical Data Port Pinouts - Page 51 Technical Data Port Pinouts This section provides the technical specifications for the IP Office ports with the exception of the USB port and cable. All diagrams are viewed from the front. The USB por t and cable (up to 5 meters) are standard.
Page 52 - Port Pinouts Technical Data ISDN Port – PRI (RJ45) Pin No. Description Signal Direction 1 Receive Data (Rx-A) Í 2 Receive Data (Rx-B) Í 4 Transmit Data (Tx-A) Î Pin 1 Pin 8 5 Transmit Data (Tx-B) Î LAN Port – 10/100 BaseT For IP Office 403/406 the information below refers to LAN ports 1 – 7.
Technical Data Port Pinouts - Page 53 Audio Port (3.5mm Stereo Jack Socket) Pin No. Description Signal Direction Common Common Left Audio in – Left Channel Í Left Right Common Right Audio in – Right Channel Í Expansion Port (RJ45 Socket) Pin No.
Page 54 - Port Pinouts Technical Data WAN Port (37 Way D-Ty pe Socket) Pin 1 Pin 37 Pin No. Description Signal Dir. Pin No. Description Signal Dir. 1 V11 Rx-B Í 20 V11 Rx-A Í 2 V11 Ind-A Í 21 V11 I.
Technical Data Cables - Page 55 Cables This section provides information about t he cables that are used with IP Office. Refer to page 51 for port pin out details. All of the following cables are for internal use only. All structured cabling/site wiring must conform to all local regulations.
Page 56 - Cables Technical Data DT Line Cord for Structured Cabling SAP Code.:- 700047871 A B C D A RJ11 Plug. B RJ45 Plug. C Cable. D 4 meters. Pin Connections RJ11 Pin Number RJ45 Pin Number 3 5 4 4 Caution: Other connections may be present in cables and or structured cabling.
Technical Data Cables - Page 57 PRI/BRI ISDN Cable SAP Code:- 700213440 Supply: As standard with IP Office systems. A B C D A RJ45 Plug. B RJ45 Plug. C Cat 5 UTP cable - RED .
Page 58 - Cables Technical Data LAN Interconnect Cable SAP Code:- 700213465 Supply: The cable is supplied with the WAN3 Expansion Module. A B C D A RJ45 Plug.
Technical Data Cables - Page 59 LAN Cable SAP Code:- 700213481 A B C D A RJ45 Plug. B RJ45 Plug. C Cat 5 UTP cable - GREY . D 3 meters. Pin Connections End A Color Cable Notes End B 1 White/Orange 1 2.
Page 60 - Cables Technical Data LAN Crossover Cable SAP Code:- 700213473 A B C D A RJ45 Plug. B RJ45 Plug. C Cat 5 UTP cable - BLACK . D 3 meters. Pin Connections End A Color Cable Notes End B 1 White.
Technical Data Cables - Page 61 Expansion Interconnect Cable SAP Code:- 700213457 Supply: One per Expansion Module. A B C D A Shielded RJ45 Plug. B Shielded RJ45 Plug.
Page 62 - Cables Technical Data V.24/V.28 WAN Cable SAP Code:- 700213416 A B C D E A 37 Way D-Type Plug with UNC 4-40 locking screws. B 25 Way D-Type Plug with UNC 4-40 locking screws.
Technical Data Cables - Page 63 X.21 WAN Cable SAP Code:- 700213408 A B C D E A 37 Way D-Type Plug with UNC 4-40 locking screws. B 15 Way D-Type Plug with M3 locking screws.
Page 64 - Cables Technical Data V.35 WAN Cable SAP Code:- 700213424 A B C D E A 37 Way D-Type Plug with UNC 4-40 locking screws. B 34 Way MRAC Plug. C Label D 10 twisted pair screened cable - each core is 7/0.
Technical Data Cables - Page 65 Telephone Converter Cables The following diagrams show the pin-outs of vari ous Structured Cabling Telephone Converters. The first two telephone converters shown provide the required conversion allowing correct operation of the attached telephone.
Page 66 - Port Safety Classification Technical Data Port Safety Classification The Avaya IP Office systems have the following ports: • Expansion ports • 10/100 BaseT LAN ports • Telephone ports .
Technical Data Technical Specifications - Page 67 Technical Specifications General Dimensions IP401: Width: 255mm. Height: 71mm. Depth: 235mm. IP403/6/12 and Expansion Modules : Width: 445mm. Height: 71mm. Depth: 245mm Environmental 0 to +40 ° C. 95% relative humidity, non-condensing.
Page 68 - Technical Specifications Technical Data Protocols Protocol Information A-Law - - - PCM encoding (mainly used outside N.America) µ -Law - - - PCM encoding (mainly used in N.America and Japan) V.120 - - - A standard Rate Adaption mechanism. V.
Index - Page 69 Index Analog 4....................................................................................................................... .......................................................... 14 , 18 , 22 Analogue Ports ..............
Performance figures and data quoted in this document are typical, and must be specifically confirmed in writing by Avaya before they become applicable to any particular order or contract. The company reserves the right to make alterations or amendments to the detailed specifications at its discretion.
Ein wichtiger Punkt beim Kauf des Geräts Avaya 40DHB0002USCL (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Avaya 40DHB0002USCL noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Avaya 40DHB0002USCL - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Avaya 40DHB0002USCL reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Avaya 40DHB0002USCL erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Avaya 40DHB0002USCL besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Avaya 40DHB0002USCL verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Avaya 40DHB0002USCL. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Avaya 40DHB0002USCL gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.