TEST RUN SER VICE MANUAL R410A Models Indoor Units Class 7 9 12 18 24 36 48 X 4-W a y Air Discharge Semi-Concealed XHX1252 XHX1852 XHX2452 XHX3652 A 1-W a y Air Discharge Semi-Concealed AHX0752 AH.
i SM830157_W-2WAY_ECO-i.indb 2 SM830157_W-2WAY_ECO-i.indb 2 2007/06/08 14:23:11 2007/06/08 14:23:11.
ii 2. The standards f or minimum room volume are as f ol- lows . (1) No par tition (shaded por tion) (2) When there is an eff ective opening with the adjacent room f or ventilation of leaking refrigerant gas (open- ing without a door , or an opening 0.
iii Section 1: TEST R UN ..............................................................................................................1-1 1. T est Run ...................................................................................................
1-1 T est Run 1 2 3 4 5 6 7 8 Contents 1. TEST RUN 1. T est Run .............................................................................................................................. 1-2 1. Preparing for T est Run .............................
1-2 T est Run 1 2 3 4 5 6 7 8 1. T est Run 1. Preparing for T est Run Bef ore attempting to star t the air conditioner , check the f ol- lowing. (1) All loose matter is remov ed from the cabinet, especially steel fi lings, bits of wire , and clips. (2) The control wiring is correctly connected and all electr ical connections are tight.
1-3 T est Run 1 2 3 4 5 6 7 8 YES Make necessary corrections. Check the alarm contents. Check the alarm contents. Turn OFF the indoor and outdoor unit power . NO YES NO *1 *2 *3 *3 *2 CASE 1 CASE 2 CASE 3B CASE 3A YES YES NO YES NO NO NO YES YES NO Recheck the items to check bef ore the test run.
1-4 T est Run 1 2 3 4 5 6 7 8 2. Setting of Unit Control PCB 1. Main Outdoor Unit PCB Setting S003 S002 CN100 CN101 CN003 S004 S006 S005 S007.
1-5 T est Run 1 2 3 4 5 6 7 8 2. Setting of Unit Control PCB Examples of the No . of indoor units settings (S005, S004) z 2 3 2 1 ON 1 ON ON 3 12 3 2 1 ON 3 1 1 1 1 1 ON 1 2 3 ON 1 2 3 ON 1 2 3 ON 1 2.
1-6 T est Run 1 2 3 4 5 6 7 8 3. A uto Address Setting 1. A uto Address Setting Basic wiring diagram: Example (1) • If link wiring is not used (The inter-unit contr ol wires are not connected to multiple refrigerant systems.) Indoor unit addresses can be set without operating the compressors.
1-7 T est Run 1 2 3 4 5 6 7 8 1-1 1-2 2-1 2-2 2-9 1-3 1-13 2 9 2 1 ON 3 ON 1 2 3 ON 1 2 3 3 2 1 ON ON 1 2 3 ON 1 2 2 ON 1 3 1 1 ON 3 2 ON 1 2 2 ON 1 3 3 2 1 ON ON OFF ON OFF ON OFF ON OFF ON OFF ON OF.
1-8 T est Run 1 2 3 4 5 6 7 8 3. A uto Address Setting Case 2 A utomatic Address Setting (no compressor operation) Indoor and outdoor unit power can be turned ON f or each system separately . Indoor unit addresses can be set without operating the compressors.
1-9 T est Run 1 2 3 4 5 6 7 8 3. A uto Address Setting Case 3A A utomatic Address Setting in Heating Mode Indoor and outdoor unit power cannot be turned ON f or each system separately . In the f ollowing, automatic setting of indoor unit addresses is not possible if the compressors are not oper ating.
1-10 T est Run 1 2 3 4 5 6 7 8 3. A uto Address Setting Case 3B A utomatic Address Setting in Cooling Mode Indoor and outdoor unit power cannot be turned ON f or each system separately . In the f ollowing, automatic setting of indoor unit addresses is not possible if the compressors are not oper ating.
1-11 T est Run 1 2 3 4 5 6 7 8 3. A uto Address Setting Display during automatic ad dress setting On outdoor main unit PCB LED 1 2 Blink alternatel y * Do not shor t-circuit the automatic address setting pin (CN100) again while automatic address setting is in progress.
1-12 T est Run 1 2 3 4 5 6 7 8 4. Remote Controller T est Run Settings Request concerning recording the indoor/outdoor unit combination Nos. After automatic address setting has been completed, be sure to record them f or future reference .
1-13 T est Run 1 2 3 4 5 6 7 8 5. Caution for Pump Do wn 5. Caution for Pump Do wn Pump down means refrigerant gas in the system is returned to the outdoor unit. Pump down is used when the unit is to be mov ed, or bef ore ser vicing the refrigerant circuit.
1-14 T est Run 1 2 3 4 5 6 7 8 6. Meaning of Alarm Messages 6. Meaning of Alarm Messages T able of Self-Diagnostics Functions and Description of Alarm Displays Alarm messages are indicated by the blinking of LED 1 and 2 (D72, D75) on the outdoor unit PCB .
1-15 T est Run 1 2 3 4 5 6 7 8 6. Meaning of Alarm Messages P ossible cause of malfunction Alarm Message Activation of protective device Protective de vice in outdoor unit is activated. Compressor therminal protector is activated. P ower supply v oltage is unusual.
1-16 T est Run 1 2 3 4 5 6 7 8 6. Meaning of Alarm Messages Alarm messages display ed on system controller Serial communication errors Mis-setting Error in transmitting serial communication signal Indoor or main outdoor unit is not oparating correctly .
2-1 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions Contents 2. REMO TE CONTR OL FUNCTIONS 1.Main Operating Functions .................................................................................................. 2-2 1. Room T emperature Control .
2-2 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 1. Main Operating Functions 1. Room T emperature Control The thermostat is tur ned ON/OFF according to as shown belo w .
2-3 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 1. Main Operating Functions 2. A utomatic Control f or Heating and Cooling A utomatic Heating/Cooling Control (1) When operation star ts, heating or cooling is selected according to the set temper ature and the room temperature.
2-4 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 2. Wireless Remote Contr oller Optional Controller (Remote Contr oller) Wireless Remote Controller / RCS-SH80AAB.WL (f or X T ype) / RCS-TRP80AAB.WL (for A, T T ype) / RCS- BH80AAB.WL (for U , D T ype) / RCS - SH1AAB (for K T ype) 1.
2-5 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 2. Wireless Remote Contr oller F: FIL TER button If a separately installed signal receiv er is being employ ed, this button is used to turn off its filter lamp . When the filter lamp has lighted, first clean the filter , and then press the FIL TER button to turn off the filter lamp .
2-6 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 2. Wireless Remote Contr oller The wireless remote control unit sends the temperature signal to the air conditioner regularly at fi ve-minute intervals.
2-7 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 2. Wireless Remote Contr oller 2. Receiver The signal receivers with the e xception of the separately installed signal receiver are mounted on the indoor units. A: Receiver This section picks up infrared signals from the wireless remote control unit (transmitter).
2-8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 2. Wireless Remote Contr oller 3. Operation • T o warm up the system, the power mains must be turned on at least five (5) hours bef ore operation. STEP 1 T o start the air conditioner: Press the operation b utton (ON/OFF button).
2-9 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 2. Wireless Remote Contr oller 4. Using the Wireless Remote Control Unit Slide switch This is used to set the operation mode of the indoor units and to set the flaps.
2-10 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 2. Wireless Remote Contr oller 5. Address Settings When mounting the wireless remote control unit on a wall for use • Bef ore mounting .
2-11 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 2. Wireless Remote Contr oller Wireless remote control unit address displays …… X type P osition of address switch on signal receiver (inside indoor unit) * The address switch in the operation area may be set to any position.
2-12 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 2. Wireless Remote Contr oller 6. Emergency Operation In any of the f ollowing e v ents, use the Emergency operation b utton to operate the air conditioner on a makeshift basis .
2-13 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 2. Wireless Remote Contr oller A, U , D type Initiate operation using the Emergency operation b utton in the signal receiver .
2-14 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 2. Wireless Remote Contr oller 7. T roubleshooting Check out the f ollowing points before requesting service.
2-15 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 3. Timer Remote Controller (RCS-TM80BG) 1. How to Use the Timer Remote Contr oller 15 14 16 17 23 25 27 29 26 28 30 18 21 22 20 24 12 1 2 5 7 3 8 6 9 31 10 4 11 13 Operating buttons Display 8 10 9 13 11 12 1 3 4 7 2 5 6 SM830157_W-2WAY_ECO-i.
2-16 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 3. Timer Remote Controller (RCS-TM80BG) 2. Names and Operations 1. Start/Stop button Pushing this button starts, and pushing again stops the unit. 2. Operation lamp The lamp is turned on when an air conditioner is in opera- tion.
2-17 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 3. Timer Remote Controller (RCS-TM80BG) 17. Operation mode change control indication Displa ys when an operation mode is entered by the re- mote control unit, while another operation mode has been already selected.
2-18 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 3. Timer Remote Controller (RCS-TM80BG) 3. Installation Manual f or Timer Remote Controller Accessories for remote controller s witch 4.
2-19 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 3. Timer Remote Controller (RCS-TM80BG) Use A WG#20 to AWG#16 wires . Remote controller wiring can be extended to a maximum of 1640 ft. (1) Strip the insulation to approximately 35/64" from the ends of the wires that will be connected.
2-20 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 3. Timer Remote Controller (RCS-TM80BG) Fig. 2-4 Fi g . 2-5 5/32 7/64 4-23/32 4-23/32 5/8 1-1/2 1 1 3/16 × 3/8 53/64 4-13/32 15/16 11/64.
2-21 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 3. Timer Remote Controller (RCS-TM80BG) 10. Setting the Present Time 1. Press and hold for more than 2 seconds to enter in the present day and time setting mode. Once you enter in the setting mode , , “ ”(day) and “time” fl ash.
2-22 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 3. Timer Remote Controller (RCS-TM80BG) Checking W eekly Timer Set the weekly progr am assigning a given timer to each da y of the week. Maximum of 6 progr ams a day and 42 prog rams a week can be set.
2-23 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 3. Timer Remote Controller (RCS-TM80BG) Changing the Program Timer T o set the weekly prog ram, f ollow the steps below . 1. Select the program you want to set in the pr ogram confi rmation mode , and press .
2-24 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 3. Timer Remote Controller (RCS-TM80BG) 4. Set the program pattern. (program step 3) There are 4 program patterns. Pressing / repeats the f ollowing displa y patter ns. P attern 1 The indoor unit star ts operation at the progr ammed time.
2-25 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 3. Timer Remote Controller (RCS-TM80BG) Deleting the Program Timer T o delete the progr am timer setting, follo w the steps below . 1. Press to enter the program confi rmation mode. 2. Press / to select the day of the program y ou want to de- lete.
2-26 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 3. Timer Remote Controller (RCS-TM80BG) Duplicating the Program Timer Y ou can duplicate the preset program by da y . Select the copy sour ce. 1. If is pressed in program checking mode , it enters the cop y mode (Selecting the copy source ) of the pro- gram timer .
2-27 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 3. Timer Remote Controller (RCS-TM80BG) Outing function is a function that pre vents the room temperature from increasing too m uch (or decreasing too much) when no one is in the room. An air conditioner works automatically if this function is set effectiv e.
2-28 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 3. Timer Remote Controller (RCS-TM80BG) 1. Press and hold for more than 2 seconds to display the upper limit temperature setting screen. , and the upper limit temperature start fl ashing.
2-29 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 3. Timer Remote Controller (RCS-TM80BG) 13. Sleeping Function * This function leads you to a comf ortable sleep and chang- es the room temperature during your sleep . * Y ou can set the off timer e very one hour from 1 to 10 hours.
2-30 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 3. Timer Remote Controller (RCS-TM80BG) 14. Wired Remote Controller T est Run Settings 1. Press the remote controller button f or 4 seconds or longer . 2. “TEST” appears on the LCD displa y while the test run is in progress.
2-31 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 3. Timer Remote Controller (RCS-TM80BG) 15. Simple Settings Function • This allo ws the filter lifetime , operating mode prior- ity cha.
2-32 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 3. Timer Remote Controller (RCS-TM80BG) 0000 Not dis play ed 0001 150 ho urs 0002 2,500 ho urs 0003 5,000 ho urs 0004 10,000 ho urs Fil ter sig n ON tim e (filte r lifet ime) 0005 Use the f ilter clo gg ing se nsor .
2-33 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 3. Timer Remote Controller (RCS-TM80BG) 7 3 1 6 1 5 4 2 16. Detailed Settings Functions • This allo ws the system address, indoor unit .
2-34 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 3. Timer Remote Controller (RCS-TM80BG) List of D e tail ed Se tt ing Ite ms Item code Item No. No. No. Setting data 000 0 4-W a y Air Discharg e Semi-Concealed (X) 000 5 000 8 000 6 Ty p e In doo r un it capa city 000 1 Unit N o.
2-35 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 3. Timer Remote Controller (RCS-TM80BG) Setting data Description No. Item Item code F orced ther mostat ON time Cooling discharge tempera.
2-36 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions Sett in g d a ta Ite m code Ite m No. Descripti on 0000 No forced operat ion 0001 Forced opera ti on for 1 minute Automatic drain pump operation 0060 Continuous operation 0000 None V e ntilation fan o peratio n 0001 Ventilation fan operated by remote controller.
2-37 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions Sett i ng d a ta Ite m code Ite m No. Descript ion DC fan ta p operating mode Purpose 0000 Standard St andard (settin g at ti me of ship .
2-38 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions T able 1 T able of DC F an Motor T ap Settings (4-way Air Discharge Semi-Concealed type) T able 2 T able of DC F an Motor T ap Settings (.
2-39 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions Selecting the DC fan motor tap (when setting from the PCB) ● 4-way Air Disc harge Semi-Concealed type <Procedure> Stop the system bef ore performing these steps. Open the electrical component box cov er , then check the indoor unit control PCB .
2-40 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 3. Timer Remote Controller (RCS-TM80BG) 17. Remote Controller Servicing Functions T e s t r u n O p e r a t i o n w i t h f o r c e d t h e r m o s t a t O N P r e s s a n d h o l d t h e b u t t o n f o r 4 seconds or longer.
2-41 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 3. Timer Remote Controller (RCS-TM80BG) 2 1 4 3 T est Run Function Operates the unit with the thermostat forced ON. <Procedure> Press and hold the button f or 4 seconds or longer . “T est” appears on the remote controller LCD displa y .
2-42 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Remote Contr ol Functions 2 1 4 5 3 NOTE: The temperature on the remote controller is displayed in Celusis (C). Please note that you will not mistakenly read it in Fahrenheit (F) on the display . Sensor T emperature Diaplay 3.
3-1 T r ouble Diagnosis 1 2 3 4 5 6 7 8 Contents 1. Contents of Remote Controller Switch Alarm Displa y ....................................................3-2 2. Outdoor Unit Control PCB LED Displa y ..................................................
3-2 T r ouble Diagnosis 1 2 3 4 5 6 7 8 1. Contents of Remote Contr oller Switch Alarm Displa y Remote controller is detecting error signal from indoor unit. Indoor unit is detecting error signal from outdoor unit. Outdoor unit is detecting error signal from indoor unit.
3-3 T r ouble Diagnosis 1 2 3 4 5 6 7 8 1. Contents of Remote Contr oller Switch Alarm Displa y Overload current detected. Outdoor unit Lock current detected.
3-4 T r ouble Diagnosis 1 2 3 4 5 6 7 8 2. Outdoor Unit Contr ol PCB LED Display ( : ON : Blinking : OFF) LED (RED) Display meaning 12 After the power is turned ON (and automatic address setting is not in progress), no communication with the indoor units in that system is possib le.
3-5 T r ouble Diagnosis 1 2 3 4 5 6 7 8 3. W -2W A Y ECO-i Alarm Codes W -2W A Y ECO-i T rouble Diagnosis 3-10 3-10 3-11 3-11 3-11 3-12 3-14 3-14 3-15 3-15 3-15 3-14 3-15 3-16 3-16 3-16 3-17 Alarm code Alarm meaning Page E06 Outdoor unit f ailed to receive serial communication signals from indoor unit.
3-6 T r ouble Diagnosis 1 2 3 4 5 6 7 8 E06 alarm Alarm code E06 Alarm meaning Outdoor unit failed to receiv e serial communication signals from indoor unit.
3-7 T r ouble Diagnosis 1 2 3 4 5 6 7 8 E16 Alarm Alarm code E16 Alarm meaning Automatic address setting alarm (too many units) Alarm conditions • There were a number of indoor units w as too many when A utomatic address setting was perf ormed at a number of indoor units.
3-8 T r ouble Diagnosis 1 2 3 4 5 6 7 8 3. W -2W A Y ECO-i Alarm Codes E25 Alarm Alarm code E25 — — — — Alarm meaning Outdoor unit address setting failure (duplication) Alarm conditions Communication by the outdoor unit main/sub control wiring was receiv ed that contained the same address as that unit 5 times or more within 3 minutes.
3-9 T r ouble Diagnosis 1 2 3 4 5 6 7 8 3. W -2W A Y ECO-i Alarm Codes (3) A/D step is 10 steps or less (shor t circuit). F04, F05, F22 Alarm Alarm code F04, F05, F22 Alarm meaning Compressor 1 discha.
3-10 T r ouble Diagnosis 1 2 3 4 5 6 7 8 3. W -2W A Y ECO-i Alarm Codes F06, F23 Alarm Alarm code F06, F23 Alarm meaning Gas temperature sensor (EXG1) trouble at outdoor heat e xchanger 1; Gas temperature sensor (EXG2) trouble at outdoor heat e xchanger 2 Alarm conditions (1) A/D step is 10 steps or less (short circuit).
3-11 T r ouble Diagnosis 1 2 3 4 5 6 7 8 3. W -2W A Y ECO-i Alarm Codes F08 Alarm meaning Outdoor air temperature sensor (AIR TEMP) trouble Alarm conditions (1) A/D step is 10 steps or less (short circuit).
3-12 T r ouble Diagnosis 1 2 3 4 5 6 7 8 3. W -2W A Y ECO-i Alarm Codes F31 Alarm Alarm code F31 Alarm meaning Outdoor unit non-volatile memory (EEPROM) trouble Alarm conditions (1) Non-volatile memor y is not present when pow er initialization occurs.
3-13 T r ouble Diagnosis 1 2 3 4 5 6 7 8 3. W -2W A Y ECO-i Alarm Codes H 06 Al arm Alarm code H06 Alarm meaning Abnor mal low-pressure drop Alarm conditions A pre-tr ip occurs during the unit’ s operation when the lo w-pressure sensor installed at constant low-pressure parts detects a pressure of 7.
3-14 T r ouble Diagnosis 1 2 3 4 5 6 7 8 3. W -2W A Y ECO-i Alarm Codes H11, H12, H21, H22 Alarm Alarm code Alarm meaning Alarm conditions Probable cause Check Correction Example — (1) Compressor f .
3-15 T r ouble Diagnosis 1 2 3 4 5 6 7 8 3. W -2W A Y ECO-i Alarm Codes CT circuit f ailure H13, H23 Alarm Alarm code H13, H23 Alarm meaning Compressor 2 CT sensor (CT2) disconnected or shor t-circuit; Compressor 3 CT sensor (CT3) disconnected or shor t-circuit.
3-16 T r ouble Diagnosis 1 2 3 4 5 6 7 8 H 31 Al arm Alarm code H31 Alarm meaning HIC trouble alarm Alarm conditions This alar m occurs when the microcomputer identifies a trouble signal (indicating abnormal HIC temperature or other troub le) from the HIC.
3-17 T r ouble Diagnosis 1 2 3 4 5 6 7 8 3. W -2W A Y ECO-i Alarm Codes L10 Alarm Alarm code L10 Alarm meaning Outdoor unit capacity not set Alarm conditions The outdoor unit capacity has not been set, or the setting is not allowed by the system. Probable cause This alar m occurs because the capacity has not been set.
3-18 T r ouble Diagnosis 1 2 3 4 5 6 7 8 3. W -2W A Y ECO-i Alarm Codes P03, P17, P18 Alarm Alarm code P03, P17, P18 Alarm meaning Compressor 1 discharge temperature trouble; Compressor 2 discharge te.
3-19 T r ouble Diagnosis 1 2 3 4 5 6 7 8 3. W -2W A Y ECO-i Alarm Codes Correction Replace the f ailed par t and correct the amount of refrigerant charge. Example — — Notes Alarm code P04 Alarm meaning Alarm conditions Probable cause Check High-pressure s witch activated.
3-20 T r ouble Diagnosis 1 2 3 4 5 6 7 8 3. W -2W A Y ECO-i Alarm Codes P05 Alarm Alarm code P05 Alarm meaning Rev erse phase (or missing phase) detected Alarm conditions This alar m occurs when a rev erse phase or missing phase is detected in the L1-L2-L3 phases.
3-21 T r ouble Diagnosis 1 2 3 4 5 6 7 8 P22 Alarm Alarm code P22 Alarm meaning Fan motor troub le Alarm conditions Fan motor start failure , fan motor Hall IC input f ailure Probable cause P ossible causes are a Hall IC input circuit f ailure and a fan HIC f ailure.
3-22 T r ouble Diagnosis 1 2 3 4 5 6 7 8 4. Blinking (Inspection) Displa y on the Remote Contr oller Currently the blinking inspection displa y can be display ed only on the wired remote controller and system remote controller .
3-23 T r ouble Diagnosis 1 2 3 4 5 6 7 8 4. Blinking (Inspection) Displa y on the Remote Contr oller Blinking inspection display (2) (compressor ma gnet SW seizing detection) Alarm code Alarm meaning .
SM830157_W-2WAY_ECO-i.indb 24 SM830157_W-2WAY_ECO-i.indb 24 2007/06/08 14:23:48 2007/06/08 14:23:48.
4-1 PCB and Functions 1 2 3 4 5 6 7 8 Contents 4. PCB AND FUNCTIONS 1. Outdoor Unit Control PCB .................................................................................................4-2 1. Outdoor Unit Control PCB CR-CHDX14053 .............
4-2 PCB and Functions 1 2 3 4 5 6 7 8 1. Outdoor Unit Control PCB CR-CHDX14053 T erminal plug TEST(CN022)pin EMG(CN002)plug OC(CN001)plug RC(CN006)plug RC1(CN106)plug Control circuit fuse(F003) Low-pressure sensor LIquid temp. sensor at heat exchanger 1,2 High-pressure sensor Oil detection sensor Gas temp.
4-3 PCB and Functions 1 2 3 4 5 6 7 8 1. Outdoor Unit Contr ol PCB 2. Functions (for CR-CHDX14053) A utomatic address setting (CN100) 2P plug (white): Automatic address setting pin Shor t-circuit this.
4-4 PCB and Functions 1 2 3 4 5 6 7 8 1. Outdoor Unit Control PCB T erminal plug 3P plug (blac k): F or communications circuit impedance matching A connecting sock et (3P , black) is attached to the terminal plug at the time of shipment from the f actor y .
4-5 PCB and Functions 1 2 3 4 5 6 7 8 1. Outdoor Unit Control PCB T able 1. Setting the System Address [S002: Rotar y s witch (black), S003: 2P DIP (blue)] Outdoor system address S002 setting S003 set.
4-6 PCB and Functions 1 2 3 4 5 6 7 8 2. Indoor Unit Control PCB 1. Indoor Unit Control PCB Switc hes and Functions Indoor unit control PCB T10: 6P plug (yellow): Used f or remote control.
4-7 PCB and Functions 1 2 3 4 5 6 7 8 EMG (CN044) DISP (CN072) CHK (CN071) T10 (CN061) EXCT (CN073) GRL (CN020) JP001 F AN DRIVE (CN032) FIL TER (CN070) PO WER LED (D002) OC (CN040) EEPROM (IC010) OPT.
4-8 PCB and Functions 1 2 3 4 5 6 7 8 CHK (test) pin DISP pin TRANS-S plug EMG plug If the fuse (F002) has blo wn, deter mine the cause and correct it.
4-9 PCB and Functions 1 2 3 4 5 6 7 8 2. Indoor Unit Control PCB 4. CR1 (for CR-KR254GXH56A/KHX2452) (W all-Mounted) CHK (test) pin DISP pin TRANS-S plug EMG plug If the fuse (F002) has blo wn, deter mine the cause and correct it. Then change the sock et from the OC plug to the EMG plug.
4-10 PCB and Functions 1 2 3 4 5 6 7 8 2. Indoor Unit Control PCB 5. CR2 (for PO W -KR74GXH56/KHX0752~KHX2452) (W all-Mounted) TRANS-S plug Control circuit fuse (F201) T20 plug OP1 plug PO W -KR74GXH56-0 SM830157_W-2WAY_ECO-i.indb 10 SM830157_W-2WAY_ECO-i.
4-11 PCB and Functions 1 2 3 4 5 6 7 8 2. Indoor Unit Control PCB 6. Explanation of Functions (CR-KXRP56AN, CR-KXRP80AN, PO W -KRP50A) T10 (CN105) (f or remote control) 6P fl ag (yello w): Used f or remote control.
4-12 PCB and Functions 1 2 3 4 5 6 7 8 OPTION (CN014) 6P (white): Outputs external signals as shown in the fi gure below . OPTION (white) Indoor unit control PCB (CR1) DC 12V Relay (DC 12V , field su.
5-1 Self-Diagnosis Function T able 1 2 3 4 5 6 7 8 Contents 5. SELF-DIA GNOSIS FUNCTION T ABLE 1. Self-Diagnosis Function T able .......................................................................................... 5-2 SM830157_W-2WAY_ECO-i.indb 1 SM830157_W-2WAY_ECO-i.
5-2 Self-Diagnosis Function T able 1 2 3 4 5 6 7 8 1. Self-Diagnosis Function T able 1. Self-Diagnosis Function T able • Causes and corrections in instances when automatic address setting cannot be .
5-3 Self-Diagnosis Function T able 1 2 3 4 5 6 7 8 • When automatic address setting is star ted from the outdoor unit control PCB or from the remote controller , (SETTING) appears on the remote controller at units where the inter-unit control wiring and remote controller wiring are connected correctly .
5-4 Self-Diagnosis Function T able 1 2 3 4 5 6 7 8 1. Self-Diagnosis Function T able Alarm code Alarm meaning E06 Outdoor unit f ailed to receive serial communication signals from indoor unit.
6-1 Service Check er 1 2 3 4 5 6 7 8 Contents 6. SER VICE CHECKER 1. Outdoor Unit Maintenance Remote Controller ................................................................ 6-2 1. Over View .........................................................
6-2 Service Check er 1 2 3 4 5 6 7 8 1. Outdoor Unit Maintenance Remote Controller ● The special ser vice check er wir ing is required in order to connect the outdoor unit maintenance remote controller to the outdoor unit PCB.
6-3 Service Check er 1 2 3 4 5 6 7 8 LED 1. Outdoor Unit Maintenance Remote Controller ■ T emperature monitor Displa ys the temperature from each indoor/outdoor sensor . ■ Outdoor unit alarm history monitor Displa ys the outdoor unit alar m histor y .
6-4 Service Check er 1 2 3 4 5 6 7 8 1. Outdoor Unit Maintenance Remote Controller and correspond to Fig. 6-3 on the next page . Display (functions) The item codes can be changed with the and buttons . Outdoor unit alarm No . of connected indoor units Unit Nos.
6-5 Service Check er 1 2 3 4 5 6 7 8 1 3 2 LED <No . of connected indoor units> 4 units connected <Unit Nos. 1, 2, 3, 4 connected> 1. Outdoor Unit Maintenance Remote Controller Fig. 6-3 Fig. 6-4 Fig. 6-5 Sample display (Fig. 6-4, Fig. 6-5) XX-YY R.
6-6 Service Check er 1 2 3 4 5 6 7 8 1. Outdoor Unit Maintenance Remote Controller Concerning the 7-segment 4-digit display of remote contr oller timer time Display of unit Nos. 1 20 Display of unit Nos. 21 40 The unit Nos. of connected units are indicated by f our 7-segment digits and a colon.
6-7 Service Check er 1 2 3 4 5 6 7 8 4. Monitoring Operations Displa y the indoor unit and outdoor unit sensor temper atures. <Operating procedure> Press and hold the (CHECK) and (CANCEL) buttons simultaneously f or 4 seconds or longer to engage temperature monitor mode .
6-8 Service Check er 1 2 3 4 5 6 7 8 5. Outdoor Unit Alarm History Monitor Recalls and displa ys the outdoor unit alarm histor y . • This is f or the outdoor unit only . Indoor unit alar ms cannot be recalled. • The indoor unit alarm histor y can be viewed on the indoor unit remote controller or other controller .
6-9 Service Check er 1 2 3 4 5 6 7 8 1. Outdoor Unit Maintenance Remote Controller 6. Setting the Outdoor Unit EEPROM Data This function is used to make the outdoor unit EEPROM data settings . Setting mode 1 Press the (CHECK) b utton and the (VENTILA TION) b utton simultaneously f or 4 sec- onds or longer .
6-10 Service Check er 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 5 3 2 4 Refrigerant type : (C) and (D) are display ed alternately . The e xample here (000, 410) indicates R410A.
Section-6.indd 11 Section-6.indd 11 2007/06/08 15:46:28 2007/06/08 15:46:28.
200706MDC SM830157_W-2WAY_ECO-i.indb 1 SM830157_W-2WAY_ECO-i.indb 1 2007/06/08 14:24:06 2007/06/08 14:24:06.
Ein wichtiger Punkt beim Kauf des Geräts Sanyo UHX1252 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Sanyo UHX1252 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Sanyo UHX1252 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Sanyo UHX1252 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Sanyo UHX1252 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Sanyo UHX1252 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Sanyo UHX1252 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Sanyo UHX1252. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Sanyo UHX1252 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.