Featuring the Burner • Direct Vent Freestanding Stove • Natural Gas or Propane • Vent Horizontally or Vertically • Standard Residential • Mobile Home Approved Tested and Listed by Omni-Test Laboratories, Inc. Beaverton, Oregon Report # 028–S–38-5 AN S I Z 21.
.
Introduction 1 Travis Industries 4 1 2 2 1 0 4 93508117 Introduction We welcome you as a new owner of a Cedar Stove. In purchasing this heater you have joined the growing ranks of concerned individuals whose selection of an energy system reflects both a concern for the environment and aesthetics.
2 Safety Precautions Travis Industries 4 1 2 2 1 0 4 93508117 • IF YOU SMELL GAS: * Do not light any appliance * Extinguish any open flame * Do not touch any electrical switch or plug or unplug anyt.
Safety Precautions 3 Travis Industries 4 1 2 2 1 0 4 93508117 • Do not place clothing or other flammable items on or near the heater. Because this heater can be controlled by a thermostat there is a possibility of the heater turning on and igniting any items placed on or near it.
4 Table of Contents Travis Industries 4 1 2 2 1 0 4 93508117 Introduction Introduction ......................................................1 Important Information .........................................1 Safety Precautions Safety Precautions .....
Specifications 5 Travis Industries 4 1 2 2 1 0 4 93508117 Installation Options: • Freestanding Stove • Residential or Mobile Home • Horizontal or Vertical Vent Features: • Ember Fyre ™ Burne.
6 Installation (for qualified installers only) Travis Industries 4 1 2 2 1 0 4 93508117 Installation Warnings ! Failure to follow all of the requirements may result in property damage, bodily injury, or even death.
Installation (for qualified installers only) 7 Travis Industries 4 1 2 2 1 0 4 93508117 Heater Placement Requirements • Heater must be installed on a level surface capable of supporting the heater and vent • Due to the high temperature of the heater, it should be located out of traffic and away from furniture and draperies.
8 Installation (for qualified installers only) Travis Industries 4 1 2 2 1 0 4 93508117 Vent Requirements ! Always maintain the required 1 ” clearance (air space) to combustible materials to prevent a fire hazard. Do not fill air spaces with insulation.
Installation (for qualified installers only) 9 Travis Industries 4 1 2 2 1 0 4 93508117 Approved Vent Configurations Restrictor Position • A vent restrictor is built into the appliance to control the flow rate of exhaust gases. This ensures proper flames for the wide variety of vent configurations.
10 Installation (for qualified installers only) Travis Industries 4 1 2 2 1 0 4 93508117 Vertical Terminations with 0, 2, or 4 45° Offsets Offset Length Hor.
Installation (for qualified installers only) 11 Travis Industries 4 1 2 2 1 0 4 93508117 Horizontal Terminations with One 90° Elbow • If using a Snorkel Termination (14 ” or 36 ” ) add the snorkel height to the vertical height (snorkel terminations are used primarily for basement installations).
12 Installation (for qualified installers only) Travis Industries 4 1 2 2 1 0 4 93508117 Approved Venting Configurations with a Horizontal Termination and Two Elbows ( one 90° vertical and one 90° o.
Installation (for qualified installers only) 13 Travis Industries 4 1 2 2 1 0 4 93508117 Approved Venting Configurations with a Horizontal Termination and Three 90° Elbows (all vertical) • If using.
14 Installation (for qualified installers only) Travis Industries 4 1 2 2 1 0 4 93508117 Vertical Terminations with Two 90° Elbows • The termination must fall within the shaded area shown in the chart.
Installation (for qualified installers only) 15 Travis Industries 4 1 2 2 1 0 4 93508117 Approved Venting Configurations for Vertical Terminations with Three 90° Elbows (Two 90° Vertical and One 45° or 90° Horizontal Elbow) • The termination must fall within the shaded area shown in the chart.
16 Installation (for qualified installers only) Travis Industries 4 1 2 2 1 0 4 93508117 Termination Requirements (see the illustration below) A Minimum 9" clearance from any door or window B Min.
Installation (for qualified installers only) 17 Travis Industries 4 1 2 2 1 0 4 93508117 Finalizing the Installation ! Turn the gas control valve to “ OFF ” prior to conducting any service. 1 Install the control box following the instructions below.
18 Installation (for qualified installers only) Travis Industries 4 1 2 2 1 0 4 93508117 6 Let the heater burn for thirty minutes. Adjust the air shutter, if necessary, to achieve the correct looking flame (see the illustration below). • The air shutter adjusts the amount of air that mixes with the gas before it exits the burner holes.
Installation (for qualified installers only) 19 Travis Industries 4 1 2 2 1 0 4 93508117 Opening the Door Open the latch. With the pawl free of the strike, the door may be swung open. Swing the right panel back. When securing the door, make sure the pawl fits over the strike before tightening.
20 Installation (for qualified installers only) Travis Industries 4 1 2 2 1 0 4 93508117 Log Set and Coal Installation Step 1 Before installing the log set, make sure the burner is seated correctly. Remove the burner following the directions on page 31.
Operation 21 Travis Industries 4 1 2 2 1 0 4 93508117 Safety Notice Read this entire manual (especially the “ Safety Precautions ” on pages 2 and 3) before using this stove. Failure to follow the instructions may result in property damage, bodily injury, or even death.
22 Operation Travis Industries 4 1 2 2 1 0 4 93508117 Starting The Pilot Flame The pilot flame is required to ignite the main burners (it also plays a safety role). It should be left on once lit. It will stay lit unless the gas control valve is turned to "OFF".
Operation 23 Travis Industries 4 1 2 2 1 0 4 93508117 Starting the Heater for the First Time Cleaning Gold Surfaces Fingerprints or other marks left on gold surfaces may become etched in place if they are not wiped clean prior to turning the stove on.
24 Operation Travis Industries 4 1 2 2 1 0 4 93508117 Optional Blower - Adjusting the Speed The blower helps transfer heat from the heater into the room. It will not turn on until the heater is up to temperature (approximately 10 minutes after starting).
Maintenance 25 Travis Industries 4 1 2 2 1 0 4 93508117 Cleaning Your Heater Warning: Fingerprints or other marks left on the optional gold surface may become etched in place if they are not wiped clean prior to turning the stove on. With the heater cool, use denatured alcohol and a soft cloth to clean gold surfaces.
26 Maintenance Travis Industries 4 1 2 2 1 0 4 93508117 Troubleshooting Steps Problem: Possible Cause: Remedy: Pilot Will Not Flame A gas shut off valve is turned off ...................... The gas control knob isn ’ t turned to “ PILOT ” ......
Maintenance 27 Travis Industries 4 1 2 2 1 0 4 93508117 How this Heater Works Warning This heater was designed with safety as the primary concern. Many of the components inside this heater are for safety purposes. Therefore, only certified gas service technicians should service this heater.
28 Maintenance Travis Industries 4 1 2 2 1 0 4 93508117 Wiring Diagram 120 Volt Wiring Millivolt Wiring (for gas control valve) Orange White Piezo Igniter Thermopile Red Thermocouple Copper Co-Axial W.
Safety Label 29 Travis Industries 4 1 2 2 1 0 4 93508117 The listing label is shown below for your records. It can be found inside the left side panel. L.P . N.G. L.P . N.G. Input Rate on “HI” (BTU/Hr) . . . . . . . 31,000 31,000 Minimum Inlet Pressure (inches W .
30 Limited 7 Year Warranty Travis Industries 4 1 2 2 1 0 4 93508117 To register your TRAVIS INDUSTRIES, INC. 7 Year Warranty, complete the enclosed Warranty card and mail it within ten (10) days of the appliance purchase date to: TRAVIS INDUSTRIES, INC.
Optional Equipment 31 Travis Industries 4 1 2 2 1 0 4 93508117 LP Conversion Instructions Install the conversion kit prior to installing the gas line to ensure proper gas use. 1 Open the door (see page 19). Remove the logs and coals (if installed - page 20) 2 Remove the burner (see illustration below).
32 Optional Equipment Travis Industries 4 1 2 2 1 0 4 93508117 3 Follow the directions below to remove the natural gas orifice. Apply thread sealant to the LP orifice and tighten in place with a 1/2" open end wrench. Slide the adjustable shutter back in place over the orifice.
Optional Equipment 33 Travis Industries 4 1 2 2 1 0 4 93508117 4 Remove the pilot orifice following the instructions below. Replace with the propane pilot orifice Lift the pilot hood off the pilot assembly. 5/32" Hex Use a hex wrench to unscrew the orifice.
34 Optional Equipment Travis Industries 4 1 2 2 1 0 4 93508117 8 Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leak- test all gas connections and the gas control valve. Check the pilot. Adjust if necessary.
Optional Equipment 35 Travis Industries 4 1 2 2 1 0 4 93508117 Blower (part # 99000153) WARNING: Turn the gas control valve to off and make sure the appliance has fully cooled prior to conducting service . 1. Attach the two black wires at the rear right of the stove to the thermodisk (orientation does not matter).
36 Optional Equipment Travis Industries 4 1 2 2 1 0 4 93508117 3 Slide the left side of the blower mounting bracket over the grommets on the left mounting bracket attached to the stove (see the illustration below). Then insert the stud plate through the right side grommets and through the right mounting bracket on the stove.
Optional Equipment 37 Travis Industries 4 1 2 2 1 0 4 93508117 Gold Door (Part # 99300524) Follow the directions to the right to install the gold door. Warning : Clean the gold surface prior to starting the stove. Any marks left on the gold may become etched-in by the heat of the stove.
38 Installation Addenda Travis Industries 4 1 2 2 1 0 4 93508117 ADDENDUM #1 Class A Chimney Conversion Kit Simpson Duravent provides a conversion kit for those wishing to use an existing wood stove chimney to vent this direct vent stove. The illustration below gives an overview of this type of installation.
Installation Addenda 39 Travis Industries 4 1 2 2 1 0 4 93508117 ADDENDUM #2 Interior Masonry Chimney Conversions • Follow the requirements and use the equipment listed in the illustration to the right to install this appliance into an interior masonry chimney.
40 Index Travis Industries 4 1 2 2 1 0 4 93508117 Adjusting the Blower Speed ........................2 4 Adjusting the Flame Height .........................2 3 AFUE .........................................................5 Air Shutter Adjustment ...
Ein wichtiger Punkt beim Kauf des Geräts Avalon Stoves Cedar EF (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Avalon Stoves Cedar EF noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Avalon Stoves Cedar EF - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Avalon Stoves Cedar EF reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Avalon Stoves Cedar EF erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Avalon Stoves Cedar EF besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Avalon Stoves Cedar EF verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Avalon Stoves Cedar EF. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Avalon Stoves Cedar EF gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.