Benutzeranleitung / Produktwartung RS500 des Produzenten RuggedCom
Zur Seite of 16
Rugg edSwitch Rugg edSwitch Rugg edSwitch Rugg edSwitch RS50 0 RS50 0 RS50 0 RS50 0 Installation Guide Installation Guide Installation Guide Installation Guide RuggedCom Inc. 30 Whitmore Road, Woodbridge, On tario Canada L4L 7Z4 Web: www.
2 2008 Rugge dCom Inc. All rights r eserved Rev101 Federal Communications Commission Radio Frequency Interfe rence Statement This equipmen t has been tested and found to comply w ith the limits for a Class A digital device pursuant to Part 1 5 of the FCC Rules.
3 2008 Rugge dCom Inc. All rights r eserved Rev101 Table of Contents 1 Product Overview ..................................................................................................................... 4 1.1 Functional O verview ..............
4 2008 Rugge dCom Inc. All rights r eserved Rev101 1 Product Ov erview 1.1 Functional Overview The RuggedSw itch RS500 is a substation harde ned, fiber optical Ethe rnet switch specifically designed to ope rate in harsh environments such as those found in ele ctric utility substations and harsh industria l environments.
5 2008 Rugge dCom Inc. All rights r eserved Rev101 1.3 RS500 Front Panel Description Fig. 1.3.1 RS500 Fro nt Panel Detail ITEM Activity Comments Solid Link Established LINK LED (Yello w) Blinking .
6 2008 Rugge dCom Inc. All rights r eserved Rev101 1.4 RS500 Top and Bottom View Fig. 1.4.1 RS500 To p and Bottom View Surge Ground DC(+) DC(-) Safety Ground Stud Failsa fe Output Relay Botto m Vi.
7 2008 Rugge dCom Inc. All rights r eserved Rev101 2 Installation 2.1 DIN Rail Mounting Fig. 2.1.1 RS500 Ra il Mounting DIN RAI L DIN R AIL Mounting Latch Screw Driver Release Action Release Slot .
8 2008 Rugge dCom Inc. All rights r eserved Rev101 2.2 Power Supply Wiring and Grounding Fig. 2.2.1 RS500 P ower Supply Inputs The power supp ly input is connected as follows: 1. + = DC (+) is connect ed to the positive (+) termina l if the power source is DC or to the (Hot) terminal if t he power source is AC.
9 2008 Rugge dCom Inc. All rights r eserved Rev101 2.2.1 Powe r Supply - DC Input Fig. 2.2.2 Powe r Supply – DC Input Note: Ground bus can either be connected to the G round Stud on the rear of the RS50 0 chassis, or the Surge G round port on the screw-in termina l block.
10 2008 Rugge dCom Inc. All rights r eserved Rev101 2.3 HIPOT (Dielectric Strength) Testing HIPOT Dielectric st rength testing cannot be performed in the fie ld due to transient/surge suppression circu itry connected to the RS50 0 Surge/Chassis Ground.
11 2008 Rugge dCom Inc. All rights r eserved Rev101 2.4 Failsafe Output Wiring and Specifications The “Failsafe” outpu t relay is provided to signal critical e rror conditions that may occur on the RS500. The conta cts are energized upon power up o f the unit and remain energized until a critical error occurs.
12 2008 Rugge dCom Inc. All rights r eserved Rev101 3 T echnic al Specification s 3.1 Power Supply Specifications Power Su pply Type Minimum Input Maximum Input Fuse Rating Maximum P ower Consumption 24 VDC 18 VDC 36 VDC 5A(F) 48 VDC 36 VDC 59 VDC 3.
13 2008 Rugge dCom Inc. All rights r eserved Rev101 3.4 Fiber Optical Specifications Parameter Ports 1 to 4 10Mbps Por ts Uplink 100Mbps Port Multi-Mode Single-Mode* Multi-Mode Single-Mode* Speed .
14 2008 Rugge dCom Inc. All rights r eserved Rev101 3.6 Type Test Specifications Electrical Sa fety Levels Comments Dielectric Withstan d 2 kV rms for 1 minu te ANSI/IEEE C37.
15 2008 Rugge dCom Inc. All rights r eserved Rev101 3.7 Operating Environment Parameter Range Comments Ambient Ope rating Temperatu re -40 to 85 ° C Ambient Temperature a s measured from a 30cm radius surround ing the center of the R500 enclosure.
16 2008 Rugge dCom Inc. All rights r eserved Rev101 3.9 Agency Approvals Agency Standards Comments cCSAus, CE CSA C22.2 No . 60950, UL 60950, EN 60950 EN 61000-6 -2 Approv ed FCC FCC Part 15, Class A Approved 4 W arranty RuggedCom wa rrants this product for a period of five (5) years from date of purchase.
Ein wichtiger Punkt beim Kauf des Geräts RuggedCom RS500 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie RuggedCom RS500 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für RuggedCom RS500 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von RuggedCom RS500 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über RuggedCom RS500 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon RuggedCom RS500 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von RuggedCom RS500 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit RuggedCom RS500. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei RuggedCom RS500 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.