Benutzeranleitung / Produktwartung REMJ70 des Produzenten Remington
Zur Seite of 24
PORT ABLE FORCED AIR HEA TERS OWNER’S MANUAL 150 SIDE HANDLE PFA/PV 005 REMJ150 IMPORTANT Read and understand this manual before assembling, starting or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference.
2 102961 Safety Information ......................................................................... 2 Product Identification .................................................................... 4 Unpacking ..........................................
3 102961 SAFETY INFORMA TION Continued W ARNINGS (Continued) • Use only kerosene to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alcohol, or other highly flammable fuels.
4 102961 Side Cover PRODUCT IDENTIFICA TION Figure 1 - REMJ70 Fan Guard Power Cord Fuel Cap Fan Guard Hot Air Outlet Upper Shell Fuel Tank Lower Shell Fuel Gauge Flame-Out Control Reset Button ON/OFF .
5 102961 UNP ACKING 1. Remove all packing items applied to heater for shipment. 2. Remove all items from carton. 3. Check items for any shipping damage. If heater is damaged, promptly inform dealer where you bought heater. ASSEMBL Y These models are furnished with wheels and handles.
6 102961 THEOR Y OF OPERA TION The Fuel System: The air pump forces air through the air line. The air is then pushed through the burner head nozzle. This air causes fuel to lift from the tank. A fine mist of fuel is sprayed into the combustion chamber.
7 102961 W ARNING Review and understand the warnings in the Safety Information Section , page 3. They are needed to safely operate this heater. Follow all local codes when using this heater. OPERA TION To Start Heater 1. Follow all ventilation and safety information.
8 102961 To Stop Heater 1. Turn ON/OFF switch to “OFF.” 2. Unplug power cord from outlet. To Restart Heater 1. Wait 2 minutes after stopping heater. 2. Repeat steps under To Start Heater , page 7. Note: If shipping, transport companies require fuel tanks to be empty.
9 102961 TROUBLE- SHOOTING OBSERVED FAULT POSSIBLE CAUSE REMEDY Wrong pump pressure Dirty air output, air intake, and lint filters Dirty fuel filter Dirt in nozzle Dirty photocell lens Bad flame-out control Heater ignites, but flame-out control shuts off heater after a short period of time See Pump Pressure Adjustment , page 12.
10 102961 SER VICE PROCEDURES Upper Shell Removal 1. Remove screws along each side of heater using 5/16" nut-driver. These screws attach upper and lower shells together. 2. Lift upper shell off. 3. Remove fan guard. Figure 9 - Fuel Filter Removal (REMJ70) Side Cover Fuel Filter (REMJ70) 1.
11 102961 Fuel Filter (REMJ150) 1. Remove side cover screws using 5/16" nut-driver. 2. Remove side cover. 3. Pull upper fuel line off fuel filter neck. 4. Carefully pry bushing, lower fuel line, and fuel filter out of fuel tank. 5. Wash fuel filter with clean fuel and replace in tank.
12 102961 Air Output, Air Intake, and Lint Filters 1. Remove upper shell (see page 10). 2. Remove filter end cover screws using 5/16" nut- driver. 3. Remove filter end cover. 4. Replace air output and lint filters. 5. Wash or replace air intake filter (see Preventative Maintenance Schedule, page 8).
13 102961 Nozzle 1. Remove upper shell (see page 10). 2. Remove fan (see page 15). 3. Remove fuel and air line hoses from burner head. 4. Remove spark plug wire from spark plug. 5. Remove spark plug from burner head using 13/16" open-end wrench. 6.
14 102961 Pump Rotor (Procedure if rotor is binding) 1. Remove upper shell (see page 10). 2. Remove filter end cover screws using 5/16" nut- driver. 3. Remove filter end cover and air filters. 4. Remove pump plate screws using 5/16" nut- driver.
15 102961 REMJ70 REMJ150 Heat Output (Kcal/hr) 17,640 38,500 Fuel Consumption (liters/hr) 1.9 4.2 Fuel T ank Capacity (liters) 16 47 Run T ime per T ank (hours) 8 11 Hot Air Output (m 3 /min) 6.7@50Hz 12.4@50Hz 7.5@60Hz 13.7@60Hz V oltage 100 100 Frequency (Hz) 50/60 50/60 W attage (W) 200 340 Pump Pressure (kg/cm 2 ) 0.
16 102961 ILLUSTRA TED P ARTS BREAKDOWN REMJ70 18-2 Motor and Pump Assembly 18-5 18-16 18-4 18-8 18-3 18-6 18-7 18-9 18-10 18-11 18-12 18-13 18-14 18-15 10-2 10-3 10-4 10-5 10-6 10-7 10-1 18-1 18-18 B.
17 102961 KEY PART PART NO. NUMBER DESCRIPTION QTY. 19 M50050 Rubber Boot 1 20 NTC-4C Hex locknut 2 21 M50104-02 Shorty Bushing (wires) 1 22 M11084-26 Screw, #10-16 x 3/8" 6 23 098511-81 Lower Sh.
18 102961 10-2 10-11 Motor and Pump Assembly 10-1 10-4 10-3 10-5 10-6 10-7 10-8 10-9 10-10 10-12 10-13 10-14 10-15 10-16 10-17 10-18 BURNER HEAD 100 EAI/EBI PFA/P 022 Burner Head Assembly 7-1 7-2 7-3 .
19 102961 17 101901-03 Electronic Ignitor 1 18 M11084-29 Screw, #10-16 x 3/4" 2 19 M51345-01 Fuel Line 1 20 M51150-01 Fuel Filter 1 21 M51151-02 Fuel Line Tube 1 22 M10990-3 Rubber Bushing 1 23 M.
20 102961 WHEELS AND HANDLES 3 6 5 7 2 4 1 7 4 3 5 6 1 2 REMJ70 REMJ150 KEY PART PART REMJ70 REMJ150 NO. NUMBER DESCRIPTION QTY. QTY. 1 097198-02 Handle (Rear) 1 — 097777-03 Handles — 2 2 M12345-3.
21 102961 WIRING DIAGRAMS White Photo- cell Black Blue Flame Out Control B Reset Button R Red Blue White Spark Plug Green/ Yellow Black Power Plug Green White White White Red Red Green Terminal Board Motor Ignitor Plug Receptacle Power On Switch Black Red Relay Black ACCESSOR Y Purchase accessory from your local dealer.
22 102961 NOTES _________________________________________________________________ _________________________________________________________________ ____________________________________________________.
23 102961 NOTES _________________________________________________________________ _________________________________________________________________ ____________________________________________________.
24 102961 Printed in U.S.A. 102961-01 Rev. A 06/96.
Ein wichtiger Punkt beim Kauf des Geräts Remington REMJ70 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Remington REMJ70 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Remington REMJ70 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Remington REMJ70 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Remington REMJ70 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Remington REMJ70 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Remington REMJ70 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Remington REMJ70. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Remington REMJ70 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.