Benutzeranleitung / Produktwartung RHP 33 des Produzenten Raypak
Zur Seite of 19
Raypak ® RHP Series Swimming Pool and Spa Heat Pump OWNER and INST ALLA TION MANUAL This manual should be maintained in legible condition and kept adjacent to the heat pump or in a safe place for future use. For additional information call: (03) 9757 3333 Effective Date: Dec 2004 Replaces: All Previous V ersions Part No.
PRODUCT SAFETY SIGNS AND LABELS This manual, as well as the pool/spa heat pump itself, contains product safety signs and labels. Please read these signs and labe ls, as they convey important safety information about hazards that may be potentially present in and around the heat pump.
RHP Series Swimming Pool and Spa Heat Pump OWNER and INST ALLA TION MANUAL CONTENTS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 I. Installation . . . . . . . .
Intr oduction This pool/sp a heat pump is an electro mechanical machine that incorporates a pressurised refrigerant gas in a sealed system. ONL Y trained and qualified service personnel should attempt to inst all or service this equipment.
• Each side of the unit must be located at least 300mm from walls, pipes, or other obstructions for unrestricted air intake and service access. Do not inst all the unit within 1m of fossil fuel burning heaters.
III. W ater Connections The heat pump inlet and outlet connections are NOT interchangeable. They must be connected as instructed below . 1. Connect the heat pump in the return water line between the pool filter and the pool. See page 10, Plumbing Diagrams.
Indicator Lamps : There are 6 indicator lamps located on the unit control panel: • Power (amber lamp): When lit, indicates power is applied to the unit. • Wa t e r Flow (green lamp): When lit, indicates normal water flow . • Heat Demand (green lamp): When lit, indicates the actual water temperature is below the target water temperature.
NOTE: The heat pump will be OFF when the Remote position is selected on the Po ol/Sp a selector switch. 4.Allow the heat pump to operate for a few minutes to stabilize operating pressures and to allow various component temperatures to normalize.
VIII. Summer Shutdown If you do not plan to use the pool heat pump during the summer months, secure and protect it as follows: 1. From the control panel, turn the control switch to Remote (OFF). 2. T urn the heat pump power switch to OFF. 3. Leave the valves set the way they are unless additional circulation is required.
2. B. Cabinet Care (optional) - The cabinet is designed for outdoor use and requires little care. However , you can clean it if you wish. 1. 2. W ash the cabinet with soap and water .
operation. After the desired temperature is reached, return the system to normal operation. •I s airflow through the unit being obstructed? Restrictions such as shrubbery , tall grass, dirty coils, or any other obstruction to airflow will reduce performance.
POWER SUPPL Y •V erify that all circuit breakers are reset and working properly . •I f t h e Power lamp on the control panel still does not light, contact the installing dealer , since it may be a power problem requiring an electrician. WAT E R F L O W •V erify that the filter is clean to provide good flow .
Plumbing Diagrams For systems with pumps of le ss than 2 HP(1.5Kw) (und er 300 l/min), no external bypass is required. Connections a re 50 mm pipe slip. Plumb the heat pump after the filter and before any chlorinators. Wa t e r I n (from pool or S pa) Wa t e r O u t (to pool or S pa) Filter For systems with pumps of 2 HP (1.
Heat Pump Schematic 12 4 3 A B C D 4 3 2 1 D C B A e l t i T n o i s i v e R r e b m u N e z i S A f o t e e h S 3 0 0 2 - n a J - 7 2 : e t a D : y B n w a r D b d d .
Contr ol Panel Assembly Replacement Parts List 12 4 7 13 11 10 16 11 9 15 2 5 8 14 3 6 1 ITEM QTY DESCRIPTION PART No. 11 Control Panel 21 Contactor Compressor 31 F a n Relay 41 Control Board 24Volt 5.
Contr ol Panel Cover Assembly Replacement Parts List 1 4 4 4 7 6 7 6 8 8 5 Front ITEM QTY DESCRIPTION PART No. 11 Control Panel Cover 22 P O T 31 S w i t ch Type A403 43 K n o b 51 Label Control Panel.
Heat Pump Assembly Replacement Parts List - RHP 3 3 11 15 13 12 5 9 2 9 16 7 7 18 14 6 7 3 17 19 4 10 1 8 Model RHP 33 *See assembly drawing in this manual IT EM QTY DESCRIPTION PART No.
15.
16.
Ein wichtiger Punkt beim Kauf des Geräts Raypak RHP 33 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Raypak RHP 33 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Raypak RHP 33 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Raypak RHP 33 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Raypak RHP 33 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Raypak RHP 33 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Raypak RHP 33 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Raypak RHP 33. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Raypak RHP 33 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.