crown head II ™ ELECTRIC MARINE TOILET OPERATION, MAINTENANCE, and INSTALLATION INSTRUCTIONS Manufactured after June 2002 THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED DURING BOTH INSTALLATION AND OPERATION. WARNING: Raritan Engineering Company, Inc.
• Push Button Switch (#164000) Press and hold switch until all waste is cleared from bowl. NOTE: Push Button Switch flushing is shown. Refer to manuals included with Toilet Control (TC12W), Raritime Solid State Timer with Solenoid (#RTC), or Flush Control (#SWF100) for operation Instructions.
MAINTENANCE Cleaning Instructions IMPORTANT: Do not use cleaners that contain ammonia, ethyl acetate, phosphoric acid or concentrated chlorine bleach. These will cause damage to the toilet. Using C.P. (#1PCP22), a bio-enzymatic toilet bowl cleaner (available from Raritan Engineering), will keep the bowl clean and fresh smelling.
WINTERIZING IMPORTANT • Improper winter lay up is a major cause of marine toilet failure. • Use only nontoxic antifreeze. • Flush toilet several times to clear waste from system. • Dispose of all antifreeze in accordance with local and federal regulations.
Pressurized Fresh Water Model Parts Required • 1 1/2" (38mm) I.D. hose, approximately 3 feet (1m) long • Two buckets • Nontoxic antifreeze approximately 1 quart (1 liter) Steps 1. Close discharge seacock 2. Shut off intake water at source. 3.
INSTALLATION Parts Included All Toilets Toilet Bowl (Household or Marine) Seat and Cover Discharge pump assembly Heavy Duty Push Button Switch (#164000) Mounting pads Lower Motor Cover Sea Water Model.
SPECIFICATIONS Base Depth: 10 7/8" (27.6cm) Height: 17 3/8" (44.1cm) Household 17" (43.2cm) Marine Base Width: 10 1/2" (26.8cm) Bowl Width: 14 3/8" (36.6cm) Household 13" (33cm) Marine Bowl Depth: 19 1/4" (48.9cm) Household 16 3/4" (42.
Mounting T oilet Mounting surface must be flat and solid. IMPORTANT: Do not mount where it may be subject to shower spray or other sources of external water. 1. Install seat on toilet. 2. Place toilet where it will be located. Make sure there is room to route hoses.
Mounting Atmospheric Vacuum Breaker (Pressurized Freshwater Model only) 1. Install fittings as shown. 2. Locate mounting area that is a minimum of 6" (15.3cm) above toilet. 3. Secure where top is in horizontal position. Mounting In-Line Strainer (Seawater Models Only) Make sure strainer bowl is tight.
INSTALLATION PLUMBING WARNING: Hazard of Flooding Toilets mounted at or below the waterline must have a vented loop installed in the discharge line. The top of the vented loop must be a minimum of 4" (10cm) above the waterline at the boats greatest angle of heel (see vented loop manufacturer’s instructions).
Intake Lines Pressurized Freshwater Models Install a shut off valve in intake line before water solenoid valve. 1 . Connect hose from pressurized freshwater source to a shut off valve. 2. Connect hose from shut off valve to inlet port of water solenoid valve.
WIRING WIRING WARNING: Hazard of Shock and Fire • Always use proper wire, wire connectors and fuse/circuit breaker. See Specification Chart on page 7. • Secure wire properly. • Do not connect other appliances to toilet circuit. • Make sure power is off before proceeding.
Problem Possible Cause A1. Clogged or restricted discharge line. A2. Too many bends or ells in discharge line. A3. Clogged holding tank or vented loops. A4. Mineral buildup in hoses and fittings. A5. Low voltage. A6. Damage to pump wall. A7. Full holding tank.
Part # Description 1118 Lockwasher (4) 1222AW 90 Degree discharge (opt.) 1222B Straight discharge 1226B 1/4" - 20 S/S Hex Nut (4) 1234 Bowl Gasket 1236AW Bowl Spud Assembly 1236E Bowl Elbow 1237W.
C2M* CH55 CH92 1341 1222AW CH57 CH59 1234 CH38 1226B 1236E 1236AW 1237W, 1244AW, 1244W C246, 247 F149VT C250 CH26 CH18W CH121 CH120 F149VT CH119MW CH27 C290 1222B CH58 CH51 1118 M30 M31 161107 C253 CR.
530 Orange Street, Millville, NJ 08332 USA Telephone: 856-825-4900 FAX: 856-825-4409 www.raritaneng.com Southern Office and Plant: 3101 SW Second Avenue, Fort Lauderdale, FL 33315 USA Telephone: 954-525-0378 FAX: 954-764-4370 L339 0407kgs Specifications Subject to Change Without Notice Printed in U.
Ein wichtiger Punkt beim Kauf des Geräts Raritan Engineering Crown Head II (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Raritan Engineering Crown Head II noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Raritan Engineering Crown Head II - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Raritan Engineering Crown Head II reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Raritan Engineering Crown Head II erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Raritan Engineering Crown Head II besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Raritan Engineering Crown Head II verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Raritan Engineering Crown Head II. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Raritan Engineering Crown Head II gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.