INSTALLATION INSTRUCTIONS UFM Universal Flat Mount NORTH AMERICA EUROPE AUSTRALIA, NEW ZEALAND, OCEANIA (DISTRIBUTOR) 3130 East Miraloma Avenue Anaheim, CA 92806 USA USA and Canada – Phone: 800-368-.
- 2 - - Warnings 2 - Assembly drawing 3 - Flat panel list 4 - Parts list 6 9 h t p e d d a e r h t e h t g n i k c e h C - 0 1 y a l p s i d l e n a p t a l f e h t f o r e t n e c e h t g n i d n i F.
- 3 - 1 6.000 (406 . 4) 16 . 0 0 0 ( 406. 4) 1. 943 (49. 3) 5 .000 (1 2 7 ) 28 . 0 0 0 ( 171. 2) C L 3 .500 ( 88.9) C L 5. 0 0 0 (127) 16 . 0 0 0 ( 406. 4) 24 . 2 9 0 ( 616. 97) 16 . 0 0 0 ( 406. 4) 21. 790 (553 . 4) 1. 2 4 5 ( 31. 75) A B C D E F G H B A F H 21.
- 4 - Flat panel list Hitachi EIKI Electrograph Gateway 32HDT20,CMP307XJ,CMP307XU,32HD T20 CMP401HDU, CMP402HDE, CMP402HDU, CMP4120HDU,CMP4121,CMP4121HDU,CMP4201U, CMP4202U, 42HDW10,42HDT20, 42HD T50,.
- 5 - SONY Sanyo VIEWSONIC Sampo PDP421A: M5 x 20 - ¼” nylon spacer (small) PDP42H1NA: M5 x 20 - ¼” nylon spacer (small) VPW420: M8 x 30 – ½” nylon spacers - sleeves VPW425: M8 x 30 – ¼.
- 6 - (Qt y 8) (Qty 8) M6 x 1 2 M5 x 50 M5 x 16 M5 x 25 M5 x 20 M5 x 12 M4 x 25 M4 x 16 M8 x 70 M8 x 35 (Qty 4) (Qty 4) (Qty 6) (Qty 4) (Qty 6) M8 x 30 M8 x 25 (Qty 4 ) M8 x 2 0 (Qty 6 ) (Qty 6) (Qty 6) (Qty 4 ) (Qty 8) M6 x 20 (Qty 6 ) Parts list This wall m ount is ship ped wit h all proper inst allation har dware and c omponents.
- 7 - 1/4" Ny lon spacers 5/16 " Fl at w a s h er s (metal) 1 " Ny lon s p ac ers 1/4 " N yl on s pac e r s 9/16 " Nylo n s pacers (l arge ) (small) 1/2" Ny lon spacers (.
- 8 - Parts list (con’t) Level (1) 5/16" flat washers (4) 5/16" x 3" La g bolts (4) (used on w ood studs only) Griplates™ (8) Wall plate (1) Mounting brac ket s (left & right) All of these parts are use d to install the mounti ng bracket.
- 9 - Checking the thread depth on your flat panel Inverted flat panel display Thread insert Thread depth indicator Figure 2 Figure 3 Figure 1 Markin g the de p th 1. Insert the thread depth indicator (supplied) through the thread inserts found on the back of the flat panel to make sure the inserts measure the sam e full depth and mark it.
- 10 - C L L C Finding center of the flat panel display Once the flat panel is inverted, use a measuring tape to find the center of your flat panel measuring fro m outside to outside of the chassis. See figure 1. Using a pencil lightly mark the center of your flat panel.
- 11 - Positioning the mounting brackets Inverted flat p anel Nylon spacers if Applicable ( see chart ) on p a g e 4 and 5 Center mar k Bottom of flat panel Install the nylon spacers to the mounting points on the flat panel see figure 3. Lay the left and right m ounting brackets (stamped arrows facing out).
- 12 - C L Bottom of flat panel Align the mounting brackets The mountin g brackets are designe d with a center o f viewing guide on the side of them . See figure 6. Bottom of flat panel Mounting bracket Center of flat panel Center of viewing guide Match the cent er of viewing gui de with the center line you marke d in step 1.
- 13 - DIMPLES FACING UP 3/4" DIMPLES FACING UP DIMPLES FA CING DOWN DIMPLES FAC ING DOW N Securing the mounting brackets The Griplates™ have M4, M5 M6 and M8 hole patterns to fit the hardware that your flat panel requires. EXAMPLE : If your plasma uses M8 x 20 Phillip screws.
- 14 - 16" 16" Finding the wood studs behind the wall structure Using a (commercially available) wood stud finder, locate the 16" or 24" stud centers behind the wall. Once found, make a pencil marking on the center of the wood studs.
- 15 - 16" 16" Marking the mounting points on the wall Place the bottom portion of the wall plate to the reference line and mark the four (4) lag bolt mounting points through the wall plate slots on the wall. Level the wall plate with the reference arrow pointing up to the ceiling.
- 16 - Securing the wall plate to wood studs Wall p late (4) 5/16" x 3" lag bolts and (4) flat washers (supplied) Level and secure the plate to the wall with the reference arrow facing up to the ceiling. Secure the plate using the four (4) 5/16" lag bolts and flat washers (supplied).
- 17 - Securing the wall plate to a concrete wall Level and secure the plate to the wall with the reference arrow facing up to the ceiling. Use a min dia of 5/16” x 2 ¼” lg concrete wedge anchors (commercially available). See figure 14. Use a minimum diameter of 5/16” x 2 ¼” long wedge anchors (commercially available).
- 18 - AT LEAST (2) QUALIFIED PERSONNEL ARE STRONGLY REC OMMENDED FOR INSTALLAT ION OF THIS PRODUCT . FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY AND POS SIBLE DAMAGE TO THE FLAT PANEL.
- 19 - Make any lateral shift adjustment and lock it b y tighten ing the two (2) ¼”-20 Phillips screws found on the bottom of the mounting brackets.
- 20 - PREMIER MOUNTS LIMITED LIFETIME WARRANTY What and Who is Covered by this Limited Warranty and for How Long Premier Mounts warrants this product to be free from defect s in material and workmans hip for the lifetime of the original installation of this product.
Ein wichtiger Punkt beim Kauf des Geräts Premier Mounts UFM (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Premier Mounts UFM noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Premier Mounts UFM - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Premier Mounts UFM reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Premier Mounts UFM erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Premier Mounts UFM besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Premier Mounts UFM verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Premier Mounts UFM. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Premier Mounts UFM gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.