Benutzeranleitung / Produktwartung CD-2860U-B des Produzenten Posiflex
Zur Seite of 72
1 Contents Cha pter 1 Description 1.1 Notice ....................................................... 3 1.2 Introduction ........................................... 4 1.3 Codes Read ........................................... 4 1.4 Installation .......
2 5.12 BC412 Code Para meters ...................... 4 6 5.13 Code 2 of 6 Para meters ........................ 4 8 5.14 T el e pen Para meters ............................... 5 0 Cha pter 6 M iscella neous Parameters 6.1 La nguage Selection ..........
3 Cha pter 1 De scription 1.1 Notice The ma nufa cturer shall not be liable f or technical or editorial errors or omissions contained herein; nor for incidental or con sequenti al da mages in connec- tion with the furnishing, performa nce, or use of this publication.
4 1.2 Introduction The Decoder is a n adva nced a nd versatile decoding fa cility for barcoding systems .It works with variety of bar code types, reading devices, a nd computer interfa ces. It discrimin ates about twenty different symbologies automatically.
5 Power supply for RS-232C scanner– There are 3 ways to supplying the power, use ex- ternal +5V power supply, use optional power cable (KBDC) which ta king the power from KB wedge or if the host supports +5V power from pin 9. Installing the scanner to the Host System – 1.
6 1.5 Pin Assignment A > Output Port 1. PC Keyboard Output DIN 5 MALE DIN 5 FEMALE Pin No. Function Pin No. Function 1 HOST CLK 1 KB CLK 2 HOST DA T A 2 KB DA T A 4 GND 4 GND 5 Vcc(+5V) 5 Vcc(+5V) MiniDIN 6 MALE MiniDIN 6 FEMALE Pin No. Function Pin No.
7 6 1 5 9 2. RS-232 Output DB 9 Female Pin No. Function 2 TXD 3 RXD 5 GND 7 CTS 8 RTS Power Lead Vcc (+5V) 3. USB Interface USB A Type Male Pin No. Function 1 Vcc 2 D- 4 GND 3 D+.
8 1. 6 Specification Interfa ce TTL, Keyboard , Code Read ALL UPC/EAN/JAN , Code 39, Code 39 CODABAR/N W7, Code 1 1, MSI/PLE Width of Window 80mm Depth of Field 25mm Resolution Ambient Light 1500Lux S.
9 , RS232, USB and WAND Emulation Full ASCII, Code 128, Interleave 25, Industri al 25, Matrix 25, SSEY , Code 93, China Postage, Code32/Italia n Pharmacy DC +5V ± 5% to 40 o C (32 o F to 104 o F) to 60 o C (-4 o F to 140 o F) to 85% (Non-Condensing) Straight, 5 ft.
10 Cha pter 2 Configuration - General 2.1 Flow Chart Start Configuration Recall Parameter Set All Defaults Interface Selection Input Port Selection Communication Parameters Bar Codes Parameters MSR Parameters Misc .
11 2.2 Loop of Programming The philosophy of progra mming para meters ha s been shown on the flow chart of 2.1. Ba sically user should 1. Scan Start of Conf iguration. 2. Sca n all necessary labels f or para meters that meet a pplications. 3 . Sca n End of Configuration to end the progra mming.
12 %$ + / 0 %$ + / 1 %$ + / 2 %$ + / 3 %$ + / 4 %$ + / 6 %$ + / 5 2.4 Main Page of Configuration Save Para meters Recall Stored Para meters Set All Defaults Start Configuration End Configuration Abort Configuration V ersion Information Save Para meters - The para meter settings will be saved permanently .
13 Cha pter 3 Interfa ce a nd Re ading Mode Sele ction 3. 1 Interface Selection <Keyboard Mode> RS232 Mode WAND Emulation OCIA Mode USB Mode 3.2 Memory Function <Enable> Disable %0 0 U 0 %.
14 3. 3 Reading Mode Selection <Good Read OFF> Trigger ON/OFF Continuous/Trigger OFF T esting Continuous/Auto Power On Fla sh Fla sh/Auto Power On Reserved1 Reserved2 Reserved3 Reserved4 Reserve.
15 Ch.4 Communication Para meters 4.1 RS232 Mode Para meters A> Set Up BAUD Rate 600 1200 2400 4800 <9600> 19200 38400 B> Set Up Data Bits 7 Data Bits <8 Data Bits> C> Set Up Stop.
16 D> Set Up Parity <None> Even Odd Mark Spa ce E> Ha ndsha king RTS/CTS Enable <RTS/CTS Disable> ACK/NAK Enable <ACK/NAK Disable> XON/XOFF Enable <XON/XOFF Disable> %0 Y.
17 4. 2 Keyboard Wedge Mode Para meters A> T ermin al T ype <IBM PC/A T , PS/2> IBM PC/XT IBM PS/2 25, 30 NEC 9800 Apple Des ktop Bus( ADB ) IBM 5550 IBM 122 Key (1) IBM 102 Key IBM 122 Key (.
18 B> Upper/Lower Ca se <No Cha nge> Upper Ca se Lower Ca se C> Send Character by AL T Method Enable <Disable> D> Select Numerical Pa d ON <OFF> %0 3 O 8 %0 3 O 0 %0 1 K 4 %.
19 4.3 Output Characters Para meters A> Select T erminator CR+LF None LF Spa ce HT(T AB) STX-ETX %7 S 0 + %7 S 2 + %7 S 4 + %7 S 5 + %7 S 7 + %7 S 1 + %7 S 3 + <CR>.
20 B> Time-out Between Characters <0 ms> 5 ms 10 ms 25 ms 50 ms 100 ms 200 ms 300 ms % 0070 % 0071 % 0072 % 0073 % 0074 % 0075 % 0076 % 0077.
21 4. 4 Wa nd Emulation Mode Para meters A> TTL Level Re pre sentation <Bar Equals High> Bar Equals Low B> Sca n Speed Selection <Fa st> Slow C> Output Format Selection <Output.
22 4. 5 OCIA Mode Para meters <NCR 8 Bit Format> NCR 9 Bit Format Spectra-Physics Nixdorf %0 2 J 0 %0 2 J 1 %0 2 J 2 %0 2 J 3.
23 Ch.5 Bar Code s & Others 5. 1 Symbologies Selection UPC-A <ON> OFF UPC-E <ON> OFF EAN-13/JAN-13 <ON> OFF EAN-8/JAN-8 <ON> OFF CODE 39 <ON> OFF CODE 128 <ON> .
24 Interleave 25 <ON> OFF Industrial 25 ON <OFF> Matrix 25 ON <OFF> CODE 93 ON <OFF> CODE 1 1 ON <OFF> China Postage ON <OFF> MSI/PLESSEY ON <OFF> % 0 GO8 % 0.
25 BC412 ON <OFF> Code 2 of 6 ON <OFF> T elepen ON <OFF> Reserved4 ON <OFF> Reserved5 ON <OFF> Reserved6 ON <OFF> Select All Bar Codes %1 A / + % 0 OO8 % 0 OO0 %0 P.
26 5.2 UPC/EAN/JAN Para meters A > Rea ding T ype UPCA=EAN13 ON UPCA=EAN13<OFF> ISBN Enable ISBN <Disable> ISSN Enable ISSN <Disable> Decode with Supplement <Autodiscriminate S.
27 C> Check Digit Tra nsmission UPC-A Check Digit T ra nsmission <ON> OFF UPC-E Check Digit T ra nsmission <ON> OFF EAN-8 Check Digit T ra nsmission <ON> OFF EAN-13 Check Digit T .
28 5. 3 Code 39 Para meters A> T ype of Code <Standard> Full ASCII Italia n Pharma cy/Code 32 <OFF> Itali a n Pharma cy/ Code 32 ON B> Check Digit Tra nsmission <Do Not Calculate .
29 D> Decode Asterisk Enable <Disable> E > Set Up Code Length T o set the fixed length: 1. Scan the "Begin" la bel of the desired set. 2. Go to the Deci mal V alue T a bles in Appendix A, sca n label(s) that represents the length to be read.
30 5. 4 Code 128 Para meters A> Check Digit Tra nsmission Do Not Calculate Check Digit Calculate Check Digit & T ra nsmit <Calculate Check Digit & Not T ra n smit> B> Append F NC2 ON <OFF> C> Set Up Code Length T o set the fixed length: 1.
31 <V ariable> Fix Length (2 Sets Available) 1. 1st Set Begin 2. Deci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. Deci mal V alue (Appendix A) 3.
32 5. 5 Interle ave 25 Para meters A> Check Digit Tra nsmission <Do Not Calculate Check Digit> Calculate Check Digit & T ra n smit Calculate Check Digit & Not T ra n smit B> Set Up.
33 D> Set Up Code Length T o set the fixed length: 1. Scan the "Begin" la bel of the desired set. 2. Go to the Deci mal V alue T a bles in Appendix A, sca n label(s) that represents the length to be read. 3. Scan the "Complete" la bel of the desired set.
34 5. 6 Industrial 25 Para meters A> Check Digit Tra nsmission <Do Not Calculate Check Digit> Calculate Check Digit & T ra n smit Calculate Check Digit & Not T ra n smit B> Set Up Code Length T o set the fixed length: 1. Scan the "Begin" la bel of the desired set.
35 <V ariable> Fix Length (2 Sets Available) 1. 1st Set Begin 2. Deci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. Deci mal V alue (Appendix A) 3.
36 5. 7 M atrix 25 Para meters A> Check Digit Tra nsmission <Do Not Calculate Check Digit> Calculate Check Digit & T ra n smit Calculate Check Digit & Not T ra n smit B> Set Up Code Length T o set the fixed length: 1. Scan the "Begin" la bel of the desired set.
37 <V ariable> Fix Length (2 Sets Available) 1. 1st Set Begin 2. Deci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. Deci mal V alue (Appendix A) 3.
38 5.8 CODABAR/N W7 Para meters A> Set Up Start/Stop Characters Upon T ran smission ON <OFF> B> T ran smission T ype of Start/Stop <A/B/C/D> <Start> <A/B/C/D> <Stop>.
39 C> Set Up Code Length T o set the fixed length: 1. Scan the "Begin" la bel of the desired set. 2. Go to the Deci mal V alue T a bles in Appendix A, sca n label(s) that represents the length to be read. 3. Scan the "Complete" la bel of the desired set.
40 5. 9 Code 93 Para meters A> Check Digit Tra nsmission <Calculate Check 2 Digits & Not T ra n smit> Do Not Calculate Check Digit B> Set Up Code Length T o set the fixed length: 1. Scan the "Begin" la bel of the desired set.
41 <V ariable> Fix Length (2 Sets Available) 1. 1st Set Begin 2. Deci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. Deci mal V alue (Appendix A) 3.
42 5.10 Code 1 1 Para meters A> Check Digit Tra nsmission <Do Not Calculate Check Digit> Calculate Check 1 Digit & T r a nsmit Calculate Check 1 Digit & Not T ra nsmit Calculate Check 2 Digits & T ra nsmit Calculate Check 2 Digits & Not T ra nsmit B> Set Up Code Length T o set the fixed length: 1.
43 <V ariable> Fix Length (2 Sets Available) 1. 1st Set Begin 2. Deci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. Deci mal V alue (Appendix A) 3.
44 5 .1 1 MSI/PLESSEY Code Para meters A> Check Digit Tra nsmission <Do Not Calculate Check Digit> Calculate Check Digit & T ra n smit Calculate Check Digit & Not T ra n smit B> Set Up Code Length T o set the fixed length: 1. Scan the "Begin" la bel of the desired set.
45 <V ariable> Fix Length (2 Sets Available) 1. 1st Set Begin 2. Deci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. Deci mal V alue (Appendix A) 3.
46 5.12 BC 412 Code Para meters A> Check Digit Tra nsmission Do Not Calculate Check Digit <Calculate Check Digit & T ran smit> Calculate Check Digit & Not T ra nsmit B> Set Up Code Length T o set the fixed length: 1. Scan the "Begin" la bel of the desired set.
47 <V ariable> Fix Length (2 Sets Available) 1. 1st Set Begin 2. Deci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. Deci mal V alue (Appendix A) 3.
48 5.13 Code 2 of 6 Para meters A> Check Digit Tra nsmission Do Not Calculate Check Digit <Calculate Check Digit & T ran smit> Calculate Check Digit & Not T ra nsmit B> Set Up Code Length T o set the fixed length: 1. Scan the "Begin" la bel of the desired set.
49 <V ariable> Fix Length (2 Sets Available) 1. 1st Set Begin 2. Deci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. Deci mal V alue (Appendix A) 3.
50 5.14 T e l e pen Para meters A> T ype of Code <T elepen ASCII> T elepen Numeric B> Check Digit Tra nsmission Do Not Calculate Check Digit Calculate Check Digit & T r a nsmit <Calculate Check Digit & Not T ra n smit> C> Set Up Code Length T o set the fixed length: 1.
51 <V ariable> Fix Length (2 Sets Available) 1. 1st Set Begin 2. Deci mal V alue (Appendix A) 3. 1st Set Complete 1. 2nd Set Begin 2. Deci mal V alue (Appendix A) 3.
52 Ch.6 M iscella neous Para meters 6.1 La nguage Selection <US English> UK English Italia n Spa nish French Germa n Swedish Switzerla nd Hungaria n Ja pa nese %0 Z V 0 %0 Z V 1 %0 Z V 2 %0 Z V .
53 Belgium Portuguese Denmark Netherla nds T urkey Reserved1 %0 Z V A %0 Z V B %0 Z V C %0 Z V D %0 Z V E %0 Z V F.
54 6. 2 Bar Code ID ON <OFF> Default With this function ON, a leading chara cter will be added to the output string while sca nning code, user may refer to the following table to know what kind of bar code is being sca nned. Plea se refer to the table below for matching code ID of codes read in.
55 UPC-A UPC-E EAN-13/JAN-13 EAN-8/JAN-8 CODE 39 CODE 128 CODABAR/N W7 Interleave 25 Industrial 25 Matrix 25 CODE 93 CODE 1 1 China Postage MSI/PLESSEY BC412 %9 1 A + %9 1 B + %9 1 Y + %9 1 Z + %9 1 E.
56 Code 2 of 6 T elepen Reserved4 Reserved5 Reserved6 %9 1 P + %9 1 Q + %9 1 R + %9 1 S + % 91T +.
57 6 .3 Reading Level Bar Equals High <Bar Equals Low> 6. 4 Accurac y <1 Time> 2 T i mes 3 T i mes 4 T i mes 6.5 Buzzer Bee p T one <High> Medium Low Off % 0130 % 0131 % 0132 % 0133 .
58 6.6 Sensitivity of Continuous Reading Mode <Fa st> Slow 6.7 Notebook Function Enable <Disable> 6.8 Reverse Output Characters <Disable> Enable % 0388 % 0380 % 0344 % 0340 %0 3 H 0 .
59 6. 9 Setup Deletion T o setup the deletion of output chara cters: 1. Scan the la bel of the desired set below . 2. Scan the label of the de sired symbology . 3. Go to the De cimal V alue T ables in Appendix A, scan label(s) that represents the desired position to be deleted.
60 B> Symbologies Selection UPC-A UPC-E EAN-13/JAN-13 EAN-8/JAN-8 CODE 39 CODE 128 CODABAR/N W7 Interleave 25 Industrial 25 Matrix 25 CODE 93 CODE 1 1 China Postage MSI/PLESSEY %8 1 A + %8 1 B + %8.
61 BC412 Code 2 of 6 T elepen Resvered4 Resvered5 All Codes None C> Character Position to be Deleted 1. Deci mal V alue (Appendix A) 2. Complete D> Number of Chara cters to be Deleted 1.
62 6.10 Setup Insertion T o setup the insertion of output chara cters: 1. Scan the label of the de sired set. 2. Scan the label of the de sired symbology . 3. Go to the Deci mal V alue T able s in Appendix A, sca n label(s) that represents the desired position to be inserted.
63 B> Symbologies Selection UPC-A UPC-E EAN-13/JAN-13 EAN-8/JAN-8 CODE 39 CODE 128 CODABAR/N W7 Interleave 25 Industrial 25 Matrix 25 CODE 93 CODE 1 1 China Postage MSI/PLESSEY %5 1 A + %5 1 B + %5.
64 BC412 Code 2 of 6 T elepen Resvered4 Resvered5 All Codes None C> Character Position to be Inserted 1. Deci mal V alue (Appendix A) 2. Complete D> Characters to be In serted 1.
65 %0 X H 0 %0 X H 1 IR SENSOR <Disable> Enable.
66 Appendix A Decimal V alue T able 8 0 1 2 3 4 5 6 7 9.
67 Appendix B ASCII T a ble NULL S O H STX ETX EO T ENQ ACK B E L BS HT LF VT FF C R SO S I DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN E M SUB ESC F S GS RS US 03 00 02 01 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F.
68 SP ACE ! " #$ % &' ( )* + ,- . /0 1 23 4 56 7 89 : ;< = >? 20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F.
69 @A B CD E FG H IJ K LM N OP Q RS T UV W XY Z [ ] ^_ 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4E 4D 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F.
70 `a b cd e fg h ij k lm n op q rs t uv w xy z {| } ~ DEL 60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F.
71 Appendix C Function Key T a ble F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F1 1 F12 Insert Delete Home Page Up Page Down End Left Right Up Down C1 C0 C2 C3 C4 C5 C6 C7 C8 C9 CA CB CC CD CE CF D0 D1 D2 D3 D4 D5.
72 CD-2860 条形码 读取器 操作手册 l 本品经依 ANSI C63.4 (1992) 及 FCC 规则第 15 章数字产品 B 级标准测 试通过并授与标章。 l 本品经依欧盟规章 89/336/EEC 测 .
Ein wichtiger Punkt beim Kauf des Geräts Posiflex CD-2860U-B (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Posiflex CD-2860U-B noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Posiflex CD-2860U-B - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Posiflex CD-2860U-B reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Posiflex CD-2860U-B erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Posiflex CD-2860U-B besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Posiflex CD-2860U-B verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Posiflex CD-2860U-B. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Posiflex CD-2860U-B gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.