R-410A This system uses M00036-V00.
Installation & service manual IMPORT ANT! Please Read Before Starting This air conditioning system meets strict safety and operating standards. As the installer or service person, it is an important part of your job to install or service the system so it operates safely and efficiently .
Installation & service manual CONTENTS Safety considerations 1 Accessories 2 Installation recommendations (indoor unit) 3 Installation recommendations (outdoor unit) 4 Electrical installation 5 Wi.
This manual is a guide for properly installing the Williamson-Thermoflo Wall-mounted split air conditioner . Improper installation can result in unsafe and dangerous conditions that will void the factory warranty .
The following accessories are supplied with the air conditioner . • The quantities are indicated in parenthesi s. Installation plate (1) Remote control (1) “AAA” batteries for remote control (2).
1. Before fixing the installation plate to a wall, you must determine the position of the 2 3 / 4 in (70 mm) hole through which the conduit, piping and drain hose pass to connect the indoor unit to the outdoor unit. The piping and conduit can be con- nected from the: Rear , Right or Left side of indoor unit.
Attach the outdoor unit with 4 anchor bolts and nuts (not supplied) positioned as per dimensions A, B. 9SRAO-HE Caution: The outdoor unit should not be exposed to strong winds or where it is very dusty . - T ake your neighbors into consideration so that they will not be disturbed by air blowing into their window or by noise.
1. The air conditioner shall be installed by a qualified technician in accordance with national and local electrical codes. 2. A disconnect switch shall be installed near the outdoor unit for easy disconnect of power to the air conditioner .
3 2 1 T erminal block of indoor unit 3 2 1 L1 N T erminal block of outdoor unit Power supply , 1 phase, 60 Hz INDOOR UNIT OUTDOOR UNIT Installation & service manual _6 WIRING SYSTEM DIAGRAMS Groun.
Installation & service manual _7 WIRING SYSTEM DIAGRAMS 3 2 1 T erminal block of indoor unit 3 2 1 L1 L2 T erminal block of outdoor unit Power supply , 1 phase, 60 Hz INDOOR UNIT OUTDOOR UNIT Grou.
1. The indoor unit is powered from the outdoor unit. A sufficient length of conduit and wiring shall be used from the outdoor unit to the indoor unit. 2. T o access the terminal block inside the indoor unit, remove the screw on the cover plate. (See Fig.
When connecting the refrigerant tubing - Keep all tubing runs as short as possible. - Use the flare method for connecting tubing. - Apply refrigerant lubricant to the matching surfaces of the flare and union tubes before connecting them, then tighten the nut with a torque wrench for a leak-free connection.
Installation & service manual _10 REFRIGERANT R410A: SPECIAL PRECAUTIONS WHEN INST ALLING UNIT General Information Systems using R-410A refrigerant run at a pressure of approximately 1.6 times that of similar systems using R-22 and the energy efficiency is comparable.
Installation & service manual _11 TIGHTENING REFRIGERANT PIPING CONNECTIONS Caution: Remove the protection caps on the pipes and connect the assembly piping to each connector . First, tighten the nuts manually and then with a wrench by applying the tightening torque shown below .
Installation & service manual _12 SYSTEM EV ACUA TION Condensing unit liquid and suction valves are closed to contain the charge within the unit. The unit is shipped with the valve stems closed and caps installed. Do not open the valves until the system is evacuated.
Installation & service manual _13 ADDITIONAL CHARGE AND DIST ANCE Refrigerant suitable for a piping length of 20 ft (6 m) is charged in the outdoor unit at the factory . When the pipe is longer than 20 ft (6 m), additional charging is necessary . This operation can only be performed by a qualified refrigeration specialist.
Installation & service manual _14 GAS LEAK CHECK Check that no gas escapes from the connections by using a leak detector or soapy water . A and B are the liquid and suction valves of the outdoor unit. C and D are the extremities of the indoor unit flared connections.
Installation & service manual _15 CHECKING AND TESTING OPERA TIONS Perform the operation test after completing the gas leak check of the flare nut connections and the electrical connections. 1. T o begin the test, turn on the power . 2. Press the auxiliary control button in the indoor unit or use the remote control to start the unit.
Installation & service manual _16 TECHNICAL SPECIFICA TIONS SPECIFICA TIONS *Note: Design and specifications are subject to change without notice for product improvement.
In A B C D E F G H I Models: 9SRA-HE | 12SRA-HE | 15SRA-HE | 18SRA-HE | 24SRA-HE Indoor unit Outdoor unit A F B D E H I G C Installation & service manual _17 OUTLINE AND DIMENSIONS 9SRA-HE 10 7/8 .
Installation & service manual _18 P ARTS DIAGRAM (INDOOR UNIT) INSIDE UNIT 9SRAI-HE 12SRAI-HE 15SRAI-HE 18SRAI-HE 24SRAI-HE.
REF . NO DESCRIPTION QTY 9SRAI-HE 12SRAI-HE 15SRAI-HE 18SRAI-HE 24SRAI-HE 1 Faceplate (including display glass) 1 P00843 P00843 P00844 P00844 P00845 2 Lamp board holder 1 P00846 P00846 P00864 P00864 P.
Installation & service manual _20 P ARTS DIAGRAM (OUTDOOR UNIT) OUTSIDE UNIT 9SRAO-HE 12SRAO-HE 15SRAO-HE 18SRAO-HE 24SRAO-HE.
Installation & service manual _21 P ARTS LIST (OUTSIDE UNIT) REF . NO DESCRIPTION QTY 9SRAO-HE 12SRAO-HE 15SRAO-HE 18SRAO-HE 24SRAO-HE 1 Cabinet | Front L | Painted (including fan cover) 1 P00730 .
Installation & service manual NOTE.
8201 W . Calumet Road, Milwaukee, WI 53223 USA www.williamson-ther moflo.com.
Ein wichtiger Punkt beim Kauf des Geräts Plantronics R-410A (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Plantronics R-410A noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Plantronics R-410A - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Plantronics R-410A reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Plantronics R-410A erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Plantronics R-410A besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Plantronics R-410A verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Plantronics R-410A. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Plantronics R-410A gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.