24-Port 10/100/1000Mbps with 16-Port SFP Web Smart Ethernet Switch GSW-2416SF User’s Manual - 1 -.
Trademarks Copyright © PLANET Technology Corp. 2006. Contents subject to revisi on w ithout prior notice. PLANET is a registered trademark of PLANET Technology Corp.
TABLE OF CONTENTS 1. INTRODUCTION ...................................................................................................................................................... 4 1.1 C HECKLIST .................................................
1. INTRODUCTION 1.1 Checklist Check the contents of your p ackag e for follow ing parts: z GSW-2416SF x1 z User's manual CD x1 z Quick installation guide x1 z Power cord x 1 z RS232 cable x1 z Ru.
◆ Support CSMA/CD protocol ◆ 100~240VAC, 50~60Hz universal Power input ◆ FCC, CE class A compliant 1.4 Specification Model GSW-2416SF 10/100/1000Base-T Ports 24 port RJ-45 10/100/1000Mbps, Auto Negotiation, Auto-MDI/MDI-X SFP Ports 16 port 3.
2. HARDWARE DESCRIPTION This product provides both Copper and Fiber connecter at same switch – 24 Ports TP and 16 Ports SFP (shared with Port #9 to 24), and automatically distinguis hes the speed of incoming connection. This section describes the hardware features of GSW-2416SF.
Power Notice: 1. The device is a power-required device, it means, it will not w o rk till it is powered. If your netw orks should active all the time, please consider using UPS (Uninterrupted Pow er Supply) for y our device. It will pr event you from netw ork data loss or network dow ntime.
Caution: You must use the screws supplied w ith the mounting brackets. Damage caused to the parts by using incorrect screw s uld invalidate your w arranty. wo tep 5: After the brackets are attached to the Switch, use suitable screw s to securely attach the brackets to the rack, as Step 3: Secure the brackets tightly.
3. SWITCH MANAGEMENT anage the GSW-2416SF. Topics include: - Log 3.1 Overview This chapter gives an overview of sw itch management. The GSW-2416SF provides a user-friendly, command line under console interface and Simply WEB brow ser interface .
3.2.2 Web Management You can manage the GSW-2416SF remotely by having a remote host w ith w Using this management method: The GSW (IP) address accessible for the remote host. eb browser, such as Microsoft Internet Explorer or Netscape Navigator. -2416SF must have an Internet Protocol 3.
3.4 Logging on to the GSW-2416SF for a word. When you log on to the GSW-2416SF console port for the first time, a sign-on string appears and you are prompted console login user name and pass The me is admin without passw ord. # 1. e and memorize the new passw ord after this first setup.
4. CONSOLE INTERFACE 4.1 CONNECT TO PC RS-232 serial cable Use the bundled RS-232 serial cable and attach the 9- pin female connector to the male connector on the GSW-2416SF.
4.2 Login in Login is required to access the console in terface after the self-test completes su ccessfully. The factory default user name is " admin " without passw ord. You ma y change the passw ord by use “set pass” command. Please alway s enter the d.
4.4 Getting Started >” prompt. The screen of available commands in Figure 4-4 appears, and the detail description shown in Table 4-1. 4.4.1 General Guidelines The GSW-2416SF allows users to configure the device via command line under console interface.
set flow control [n] enable/disable Enable/Disable the flow cont rol function to specific port [n] of GSW-2416SF. set vlantag [n] enable/disable Enable/Disable the VLAN Tagging to specific egress port of GSW-2416SF. set vlanaware [n] enable/disable Enable/D isable VLAN-Aware function to specific port of GSW-2416SF.
sho se refer to chapter 4.4.2.6 w flow control : Plea . sho e refer to ch w vlantag : Pleas apter 4.4.2.7 . sho ease refer to w vlanaware : Pl chapter 4.4.2.8 . sho e refer to chapter 4.4.2.9 w priority : Pleas . sho r to chapt w pvid : Please refe er 4.
Figure 4-7 Per port static screen # Notice: The TX/RX packets counted with error might because: z Packet with a bad FCS. z Packets were less than 64 by tes or greater than 1522 bytes. z Packets were dropped due to lack of resources. 4.4.2.3 Show vlan [n] Display one specific VLAN group stat us of GSW-2416SF.
4.4.2.4 Show ip Display the current IP address, net mask and gatew ay of GSW-2416SF. The IP subnet address information screen in Figure 4-9 appears. Figure 4-9 IP subnet address information screen Display the system information of GSW current software version and issued hardw are version.
4.4.2.6 Show flow control of Enabled – 802.3x flow control is enabled on Full-Duplex m ode or Backpressure is enabled on Half-Duplex mode.. Disabled – No flow control or backpressure function on no matter Full-Duplex or Half-Duplex mode. The flow control status screen in Figure 4-11 appears.
4.4.2.8 Show vlanaware Display current VLAN-aw are status on each port of GSW-2416SF. Enabled – Tagged Frame remain original VID while leaving tagged port. Disabled - Tagged Frame wouldn’t remain original VID while leaving tagged port. The VLAN-aware status screen in Figure 4-13 appears.
4.4.2.10 Show pvid Display the current per port PVID of GS W-2416SF. The Allowed PVID values are form 0-4095. The per port PVID display screen in Figure 4-15 appears. Figure 4-15 Display PVID screen 4.4.2.11 Show vid Display the current VLAN ID of each VLAN Group, the VLAN Groups and ID mappi ng status display screen in Figure 4-16 appears.
4.4.3 Set command From the main menu screen (see Figure 4-3) , input “set” and press enter. The set command list screen in Figure 4-17 appears. Figure Set port [n]: Please refer to chapter 4.4.3.1 4-17 Set command list screen This set command list contains ten items: .
4.4.3.1 Set port [n] This command allows configuring per port parameters of GSW-2416SF. the correct usage is show n as below: Set port [n]: n=1-24 , to configuring per port parameters of GSW-2416SF . Default setting: (1) A uto Speed The configuring per por t parameters screen in Figure 4-18 appears and the detail descripti on shown in table 4-2.
Figure 4-19 VLAN members Configuration screen # Notice: Change VLAN settings for every time, you have to reboot the switch to apply new settings. 4.4.3.3 Set flow control This command allows configuring per port flow control f unction of GSW-2416SF. The correct usage is shown as below : Set flo [n] =1-24, n is the specific Port ID.
4.4.3.4 Set vlantag This is an additional function of VLAN configuration. This command allows configuring per port VLAN Tagged/Unt agged status. When adding a VLAN to selected port, it tells the switch w hether to keep or remo ve the tag from a frame on egress.
Figure 4-22 VLAN aware Configuration screen # Notice: Change VLAN settings for every time, you have to reboot the sw itch to apply new settings. 4.4.3.6 Set priority This command configures the default 802.1p port priority assigned for untagged packets for a specific port of GSW-2416SF.
4.4.3.7 Set pvid This is an additional function of VLAN configuration. This command allows assign PVID for selected port of GSW-2416SF. The correct usage is show n as below: Set pvid [n] [m] [n] =1-24, n is the specific Port ID of GSW-2416SF. [m] = 1-4095, 0 reserved for management purpose; m is allow ed VLAN ID.
Figure 4-25 VID Configuration screen # Notice: Change VLAN settings for every time, you have to reboot the sw itch to apply new settings. 4.4.3.9 Set ip xxx.xxx. xxx.xxx.mmm.mmm.mmm.mmm.ggg.ggg.ggg.ggg This command allows assign IP address, netmask and gatew ay of GSW-2416SF.
Figure reen ass w: set pass [oldpass] [new pass] se the new password. 4-26 IP subnet address configuration sc 4.4.3.10 Set p This command allows assign passw ord of GSW-2416SF. The correct usage is shown as belo Default Setting: no passw ord # Notice: The symbol “ [ “ and “ ] ” are required for both old password and new password.
4.4.4 Factory default This command allows rest GSW-2416SF to factory default mode. The factory default screen in Figure 4-28 & 4-29 appears. Figure 4-28 Factory default screen Figure 4-29 Factory .
4.4.5 Reboot This command allows reboot GSW-2416SF, the reboot screen in Figure 4-30 & 4-31 appears. Figure 4-30 Switch reboot screen Figure 4-31 Switch reboot screen EM-GSW2416SFv1 - 31 -.
4.4.6 Logout This command provides logout the GSW-2416SF, the screen in Figure 4-32 appears. Fig en ure 4-32 GSW-2416SF Logout scre EM-GSW2416SFv1 - 32 -.
4.5 Firmware Update This section will show you how to use X -modem to update the firmw are of GSW-2416SF. Firmw are update requirements GSW-2416SF switch Latest firmware version VT100 terminal, or a personal computer or wo rkstation w ith terminal emulation software RS-232/DB9 null modem cable Update procedure: 1.
Figure 4-34 Firmware Update Figure 4-35 Xmodem transmit After the file send be completed, the system will reboot automatically to t he login screen. You can check if the Software version been updated.
5. WEB MANAGEMENT Before login the Web interface of GSW-2416SF, please setup the “IP A ddress” w ith local serial console port (RS232 port) and use this IP address to configure GSW-2416SF through the Web interface. Or modify your PC’s IP domain to the same w ith GSW-2416SF then use the default IP address ( 192.
5.2 Port Config This section provides current por ts status and detail setting of eac h port of GSW-2416SF. T he screen in Figure 5-3 appears and Table 5-1 describes the port configuration object of switch.
Object Description Port Indicate port 1 to port 24. Mode Allow configuring the port speed and operation mode. Draw the m enu bar to select the mode. z Auto Speed - Setup Auto negotiation. z 10 half - Force sets 10Mbps/Half-Duplex mode. z 10 Full - Force sets 10Mbps/Full-Duplex mode.
5. Setup A V LAN (VLAN) ng that limits t he broadcast domain. It allows y ou to isolate netw ork traffic so only VLAN members. Basically, creating a VLAN from a sw itch is logically uivalent of ices are still plug into the same tch The GSW-2416SF switch s po In the def ault configuration, VLAN support is “disable”.
5.3.2 VLAN setting example: -5 appears and Table 5-2 describes the port configuration of switch. 5.3.2.1 Tw o separate VLAN The diagram shows how the switch handle Tagged and Untagged traffic flow for tw o VLANs. VLAN Group 2 and VLAN Group 3 are separated VLAN.
Setup steps 1. VLA N Group Set VALN Group 1 = default-VLAN with VID (VLAN ID)=1 2. A ssign VLAN Member : VLAN 2: Port-1, Port-2 and Port-3 VLAN 3: Port-4, Port-5 and Port-6 VLAN 1: All other ports – Port-7~Port-24 3. A ssign PVID for each port: Port-1, Port-2 and Port-3: PVID= 2 Port-4, Port-5 and Port-6: PVID= 3 Port-7~Port-24: PVID= 1 4.
Figure 5-7 VLAN 1 member assign Web page screen Figure 5-8 VLAN 2 member assign Web page screen EM-GSW2416SFv1 - 41 -.
Figure 5-9 VLAN 2 member assign Web page screen # Notice: Change VLAN settings for every time, you have to reboot the sw itch to apply new settings. 5.3.2.2 Overlap VLAN The scenario described as follow: 1. Port-16 is the file server port for all the workstations 2.
5.4 Port Trunk Setup This section allows you to disable or enable trunk function of two ports or four ports toget her to speed up data transmission. The GSW-2416SF provides up to 3 T runk group, eac h group supports maximum 4 ports, the screen in Figure 5-10 appears.
# Notice: 1. After turn on the port trunk feature, port 1 and port 2 or port 17,18,19,20 should connect to another switch, hole 2. The GSW-2416SF doesn’t support LACP (Link Aggregati on control Protocol) trunk type yet. Connect with LACP type switch the trunk function might be failed.
5.5 Status Th connection info. The screen in Figure 5-12 appears. 5.5.1 Port Status is section displayed the current link status of each port on GSW-2416SF. It’s help the manager easy to get the Figure 5-12 GSW-2416SF Port Status W eb Page screen 5.
Figure 5-13 GSW-2416SF Port Statistics W eb Page screen There’re also two buttons at the statistics w eb page – “ Clear ” and “ Refresh ”. Press the “ Clear ” button will clear the current traffic statistic value.
5.6 Misc Configuration This section provides Misc Configuration of GSW-2416SF. 5.6.1 System Setup This section provides System Conf iguration of GSW-2416SF, the screen in F igure 5-14 appears and table 5-4 descriptions the System Configurati on objects of GSW-2416SF.
5.7 Tools This section provides two management tools of GSW-2416SF- Reboot and Factory Reset . mmediately. After sy stem reboot, the manager has to refresh the browser and re-login w eb interface w ith correct username “admin” and password, the screen in Figure 5-16 appears.
5.7.2 Factory Reset g configuration: z Default IP address: 192.168.0.100 t mask: 255.255.255.0 After choose this function and the following screen appears in Figure 5-17. This section provides reset GSW-2416SF to factory default mode, default value to as follow in z Subne z Default Gateway : 192.
5.8 Logout This section allows to logout the GSW-2416SF. Press “Logout” item in the Web Menu, it ta ke effect immediately . If the manager wa ” button.
6. SWITCH OPERATION 6.1 Address Table The Switch is implemented w ith an address table. This address table composed of many entries. Each entry is used to store the address information of some node in network, including MAC address, port no, etc. This information comes from the learning proce ss of Ethernet Switch.
7.TROUBLESHOOTING This chapter contains information to hel p you solve problems. If the Switch is not functioning properly, make sure the according to instructions in this manual. Ethernet Switch w as set up The Link LED is not lit Solution: Check the cable connection and remo ve duplex mode of the Switch.
APPENDIX A NETWORKING CONNECTION A.1 Switch‘s RJ-45 Pin Assignments 10/100Base-TX Contact MDI MDI-X 1 1 (TX +) 3 2 2 (TX -) 6 3 3 (RX +) 1 6 6 (RX -) 2 4, 5, 7, 8 Not used Not used A.
Figure A-1: Straigh and Crossover Cable s are with same pin assignment and color as abov e picture before deploying the t-Through Please make sure your connected cable cables into your netw ork.
Ein wichtiger Punkt beim Kauf des Geräts Planet Technology GSW-2416SF (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Planet Technology GSW-2416SF noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Planet Technology GSW-2416SF - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Planet Technology GSW-2416SF reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Planet Technology GSW-2416SF erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Planet Technology GSW-2416SF besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Planet Technology GSW-2416SF verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Planet Technology GSW-2416SF. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Planet Technology GSW-2416SF gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.