User’s Manual Phonetics, Inc. Marine Division 901 T r y ens Road Aston, P A 19014.
Every effort has been made to ensure that the inf or mation in this document is complete, accur ate and up-to-date. Phonetics, Inc. assumes no responsibility for the results of errors be yond its control.
T able of Contents iii Saf ety Instructions ............................................. v FCC Requirements ....................................................................... vi CHAPTER 1: GETTING TO KNO W Y OUR BO A T REMO TE ..................
Boat Remote User’ s Man ual iv PROGRAMMING V OICE MESSA GES .............................. 25 Recording a V oice Message ........................................................ 25 Unit ID Message ....................................................
T able of Contents v Alarm Notification ........................................................................ 59 Dial Out ....................................................................................... 60 Alarm Acknowledgment ..............
Boat Remote User’ s Man ual vi.
vii Safety Instructions Y our Boat Remote has been carefully designed to give y ou years of safe , reliable perf or mance. As with all electrical equipment, howe ver , there are a f ew basic precautions y ou should take to a void hur ting yourself or damaging the unit: Read the installation and operating instructions in this manual carefully .
Boat Remote User ’ s Man ual viii e xposed to water . 3 . The unit has been dropped, or the enclosure is damaged. 4. The unit doesn ’ t function normally when you ’ re f ollowing the operating instructions. A void using a telephone (other than a cordless type) during an electrical stor m.
ix Phonetics, Inc. 901 T r yens Road, Aston, P A 19014 (610) 558-2700 F ax: (610) 558-0222 www .sensaphone.com The telephone company ma y ask that you disconnect this equipment from the network until the problem has been corrected or until y ou are sure that the equipment is not malfunctioning.
Boat Remote User ’ s Man ual x.
Chapter 1: Getting to Know Y our Boat Remote 11 CHAPTER 1: GETTING T O KNO W Y OUR BO A T REMO TE T he Boat Remote, Fig. 1.1, is a fully-programmab le, en viron- mental monitoring system that offers e xtensive on-site and remote monitoring capabilities for y our boat.
Boat Remote User ’ s Man ual 12 The Boat Remote f eatures extensiv e capabilities to monitor a v ariety of conditions: Bilge Pump Activity - 2 separate bilge pumps AC po wer f ailure 12VDC Batter y .
Chapter 1: Getting to Know Y our Boat Remote 13 T echnical Support If any questions arise upon installation or operation of the Boat Remote, please contact Phonetics Customer Service Depar tment, at t.
Boat Remote User ’ s Man ual 14 LCD (Liquid Crystal Display) The LCD , local display , is your guide f or information and program- ming. A scrolling status screen, referred to as the idle screen, will appear when the Boat Remote is idle. The status of all inputs that are in Status-Only Mode or Active Mode are sho wn on the idle screen.
Chapter 1: Getting to Know Y our Boat Remote 15 W ar ning LED The W arning LED , red, aler ts you of alarms, A C power disconnec- tion, and phone line disconnection. The phone line connection is only check ed when changing the Operating Mode to A way mode .
Boat Remote User ’ s Man ual 16.
17 Chapter 2: Installation CHAPTER 2: INST ALLA TION C orrectly installing Boat Remote will ensure proper functioning of the unit. Please read the entire chapter bef ore star ting the installation process. Failure to pr operly install the unit will result in erratic operation, shortened product life and a v oid warranty .
Boat Remote User ’ s Man ual 18 Connecting the P ower Supply There are two entry points for wiring into the enclosure of the Boat Remote. They are: a slot on the back of the enclosure belo w the access panel and a perf orated “ punch out ” on the lower side of the enclosure.
19 Chapter 2: Installation Connecting the Battery The battery connection is for monitoring the voltage of y our boat batter y and it also pro vides power to the unit in the e vent of a pow er failure . The batter y connects to the terminals labelled 12VDC.
Boat Remote User ’ s Man ual 20 T o mount the s witch, follo w these steps: 1. Place the s witch on a hor iz ontal, flat surface in the bilge , at the desired location.
21 Chapter 2: Installation T emperature Sensors Y our Boat Remote comes with a temperature sensor connected to the TEMP1 input. This can be used to monitor the temperature where the Boat Remote is installed. Up to two additional sensors ma y be connected to the Boat Remote on the ter minals labeled TEMP2 and TEMP3.
Boat Remote User ’ s Man ual 22 Bilge Pump The Boat Remote will monitor bilge pump activity when the positiv e power wire to the bilge pump is connected to the BP1 or BP2 inputs . This pow er connection can typically be made at any one of three locations: 1.
23 Chapter 2: Installation Security Input The security input can be used with magnetic reed s witches, passive infrared detectors or an y other secur ity de vice that provides a normally open or nor mally closed contact. The security input may hav e se veral normally closed accessories attached in a chain.
Boat Remote User ’ s Man ual 24 Fig. 2.7 Connection to the Auxiliary Input Output The Boat Remote f eatures a switched 12V output signal that can be used to turn on a siren or strobe light when an alar m occurs . The power f or the output is derived from the boat battery .
Chapter 3: Programming 25 CHAPTER 3: PROGRAMMING T his chapter describes use of the ke ypad and explains the ke ypad commands for prog ramming the Boat Remote. Y ou will learn how to program V oice Messages, System P arameters, Phone P arameters , and Input Alar m P arameters.
Boat Remote User ’ s Man ual 26 Fig. 3.2 The Keypad Keys and Their Functions The K e ys In the figure abov e, please note the k eys on the ke ypad are grouped by function. The number k eys are arranged as the y are on a tele- phone f or ease of use.
Chapter 3: Programming 27 PROGRAMMING V OICE MESSA GES Boat Remote allows y ou to record f our custom alar m messages and an identification (ID) message. The f our alar m messages are f or the T emperature #1, T emperature #2, T emperature #3, and Auxiliary inputs.
Boat Remote User ’ s Man ual 28 W ait f or the beep and then begin speaking. Y ou are then given 10 seconds* to recite your message into the Boat Remote b uilt-in microphone. Sample ID message: “ Hello , this is the King Crimson dock ed at the Big Fish Mar ina.
Chapter 3: Programming 29 scroll through the rest of the menu using the do wn arrow . Press the SET ke y on the ke ypad. Press SYSTEM . The Local Displa y will prompt you to set the f ollowing System .
Boat Remote User ’ s Man ual 30 Use the number k eys. Press ENTER . Call Dela y Call Dela y is the programmed length of time the Boat Remote w aits, follo wing detection of an alarm, before it begins dial out. This applies only to the first call. Dur ing this time Boat Remote will audib ly repeat the alarm message.
Chapter 3: Programming 31 is 1 minute. T o set the intercall Dela y time, press the number k eys corresponding to the number of minutes and press ENTER , repeat to enter seconds.
Boat Remote User ’ s Man ual 32 The local displa y will prompt you to enter the f ollowing System P arameters: TAD: Voice Reps: Rings to Answer: Listen In (sec): T AD (T elephone Answ er ing De vice) The T AD feature is especially useful because it integr ates the operation of the Boat Remote with y our telephone answ ering device, i.
Chapter 3: Programming 33 Example: Answ er ing De vice: rings = 4 Boat Remote: rings until answer = 6 Using the procedure just outlined, all incoming calls will be ans wered by the telephone ans wering de vice, allo wing it to operate nor mally .
Boat Remote User ’ s Man ual 34 Press ENTER . Rings until ans wer Rings Until Ans wer is the programmed number of times the tele- phone rings before the Boat Remote will ans wer an incoming call. Boat Remote will ans wer incoming calls only when in A wa y mode.
Chapter 3: Programming 35 Use the number k eys. Press ENTER . The local displa y will prompt you to enter the f ollowing System P arameters: Speaker: Temperature: Output Trigger: Output Mode: Current .
Boat Remote User ’ s Man ual 36 ( ° F). T oggle between Celsius and F ahrenheit by pressing the MODE ke y while in the Set System menu when T emperature is display ed.
Chapter 3: Programming 37 Current Time & T oday ’ s Date The real-time cloc k is a necessar y element of y our Boat Remote. The alarm recognition time, call dela y , and bilge pump cycle rate are all based on this built-in cloc k. The clock runs on militar y time and the date is month and da y only .
Boat Remote User ’ s Man ual 38 Remote automatically will wait until outgoing calls are ans wered bef ore reciting alarm messages. Y ou hav e the ability to set a different dial out list f or each input with Boat Remote. A dial out list is a list of up to eight phone numbers , for each input, to be called in the e vent of an alarm.
Chapter 3: Programming 39 Use the number k eys. The digits will be displa yed as they are pressed. Phone Number 1: 5556789 Press the ENTER ke y on the ke ypad. Next, y ou will be prompted to choose the dialing mode , voice or beeper , f or each phone number .
Boat Remote User ’ s Man ual 40 Special Dialing The Boat Remote has provisions f or special dialing sequences. Special dialing sequences allow: • Dialing that requires an access number to connect with an outside line. • Dialing that requires the pound (#).
Chapter 3: Programming 41 combinations is incorporated into a phone number , it is counted as one digit tow ard the total of 32 digits allowed per dial out phone number . Dialing to a Beeper or P ager The follo wing e xample demonstrates just one solution to program- ming the Boat Remote f or dialing to a beeper or pager .
Boat Remote User ’ s Man ual 42 INPUTS In preparing the Boat Remote to sense an aler t condition se ver al parameters must be configured f or each input.
Chapter 3: Programming 43 A C P o wer Input T o program the alarm parameters f or the A C power input f ollow these steps: Press the SET ke y on the ke ypad. Press the 4 AC PWR k ey on the k eypad. The Input Mode will be displa yed. The default is Activ e.
Boat Remote User ’ s Man ual 44 Use the number k eys. Press ENTER . The display will prompt y ou to enter the AC P ower Input phone selection. Use the number ke ys to select the phone numbers to be dialed when the A C P ower Input is in alarm.
Chapter 3: Programming 45 Use the number k eys. Use the CODE k ey to inser t a decimal point. Press ENTER . Using the number k eys on the k eypad enter the Low Limit. The def ault is 11.0V and the range is 0-16 V olts. Use the CODE key t o inser t a decimal point.
Boat Remote User ’ s Man ual 46 Use the number ke ys to enter minutes and seconds . Press ENTER . The Input Mode will be displa yed. The default is Activ e. Press the MODE ke y on the ke ypad until the appropriate mode is shown on the display . Press the MODE ke y to toggle through the three input modes.
Chapter 3: Programming 47 Press ENTER . The display will reflect y our selection. Phone Selection: 1,2,4,6 T emperature Inputs (1, 2, & 3) The T emperature Inputs are compatible with the industry standard 10K thermistors. The monitored temper ature range is -20 ° F to 160 ° F, -29 ° C - 71 ° C.
Boat Remote User ’ s Man ual 48 Press ENTER . Using the number k eys on the k eypad enter the Low Limit. The def ault is 40 ° F . Use the CODE ke y to inser t a decimal point. Use the number k eys. Use the CODE ke y to inser t a decimal point. Press ENTER .
Chapter 3: Programming 49 Press the MODE ke y on the ke ypad until the appropriate mode is shown on the displa y . The default f or T emperature Input #1 is Activ e. The def ault for T emperature Inputs #2 and #3 is Off . Press the MODE ke y to toggle through the three input modes.
Boat Remote User ’ s Man ual 50 Bilge Pump Inputs (2) The Bilge Pump Inputs will monitor the number of on/off cycles and the accumulated run time of your bilge pumps . The alarm param- eters can be programmed to detect whether the bilge pump runs too frequently (cycle rate alarm) or for too long a period (maximum run time alarm).
Chapter 3: Programming 51 The local displa y will prompt for the Maxim um Run Time. Using the number k eys on the ke ypad, enter the number of min utes, press ENTER . Repeat for seconds. The def ault is 30 minutes and the r ange is 1 second to 999 minutes 59 seconds.
Boat Remote User ’ s Man ual 52 the eight numbers that y ou programmed f or dial out, or any combina- tion of the eight numbers . Remember , regardless of what order you enter your Input phone selections , the phone numbers will be dialed in order , according to their sequence number (1-8).
Chapter 3: Programming 53 Emergency High Water Le v el Input The High W ater Lev el Input will monitor the open or closed status of a float s witch. T o program the Emergency High W ater Le vel Input, follo w these steps. Press SET . Press HIGH W A TER .
Boat Remote User ’ s Man ual 54 Press ENTER . The display will prompt y ou to enter the Emergency High W ater Le vel Input phone selection. Use the number k eys to select the phone numbers to be dialed when the Emergency High Water Le vel Input is in alar m.
Chapter 3: Programming 55 Press AUXILIAR Y . The Local Displa y will prompt for y ou to choose normally open or normally closed. The def ault is nor mally open. Use the MODE key t o toggle between open and closed. When your choice is displa yed press ENTER .
Boat Remote User ’ s Man ual 56 Press ENTER . The display will prompt y ou to enter the Auxiliary Input phone selection. Use the number ke ys to select the phone numbers to be dialed when the A uxiliar y Input is in alarm. Y ou can choose all of the eight numbers that y ou programmed f or dial out, or any combination of the eight numbers.
Chapter 3: Programming 57 Press SECURITY . The Local Displa y will prompt for y ou to choose normally open or normally closed. The def ault is nor mally open. Use the MODE key t o toggle between open and closed. When your choice is displa yed press ENTER .
Boat Remote User ’ s Man ual 58 Press ENTER . The display will prompt y ou to enter the Secur ity Input phone selection. Use the number ke ys to select the phone numbers to be dialed when the Security Input is in alar m. Y ou can choose all of the eight numbers that y ou programmed f or dial out, or any combination of the eight numbers.
Chapter 3: Programming 59 Press WHA T IS ?. Press VOICE MESSAGE . Press TEMP #2. The pre viously recorded message will be repla yed. “ The outside temperature is 74 ° F ” T o v er ify System par ameters: Press WHA T IS ?. Press SYSTEM . A screen will appear on the Local Displa y with all of the System parameters that ha ve been progr ammed.
Boat Remote User ’ s Man ual 60.
Chapter 4: Operation 61 A fter installation and programming have been completed, Boat Remote is fully operational. This chapter e xplains the sequence of events that occur during an alarm to illustrate how Boat Remote operates. P ar t One outlines the basic alarm sequence.
Boat Remote User ’ s Man ual 62 dialing out. During this time (if the speaker is set to ON), the unit will recite an alarm message locally to indicate which input is in alarm. If someone on board acknowledges the alarm before the Call Delay time expires, the unit will not dial out.
Chapter 4: Operation 63 Remote DOES NOT speak a voice message. It calls the beeper company or service, enters the number to be displayed on the beeper , then hangs up . Alarm Acknowledgment Local Alarms can be acknowledged locally by pressing any key on the Boat Remote keypad.
Boat Remote User ’ s Man ual 64 NO TE: Y ou may enter the touch-tone ac knowledgment code ‘ 555 ’ , or ‘ 999 ’ , at any time during the alarm message. If the touch-tone acknowledgment code is not received, Boat Remote will respond by saying, “ Good-bye, ” and hang-up.
Chapter 4: Operation 65 any time during the alarm message. If the touch-tone acknowledg- ment code is not received, Boat Remote will respond by saying, “ Good-b ye. ” The alar m has not been ac knowledged. Boat Remote will hang up and wait for the rest of the intercall delay time.
Boat Remote User ’ s Man ual 66 • Phone #6: 555-6666WPP5552628# (beeper) - your beeper • Phone #7: (voice) - not programmed • Phone #8: (voice) - not programmed • Boat Remote ’ s telephone.
Chapter 4: Operation 67 Examples Each e xample is divided into three par ts: Alar m Recognition, Alarm Notification, and Ackno wledgment. Alar m Recognition ref ers to the events that occur when a monitored condition changes or exceeds progr ammed limits.
Boat Remote User ’ s Man ual 68 “ Indicate you have received warning message. ” 6) The ans wering machine can ’ t enter the ackno wledgment code, so after 10 seconds Boat Remote will say: “ Error .
Chapter 4: Operation 69 time). During this time, the unit recites the message “ The water level is too high ” . (Speaker: ON) 2) The unit is operating in A way Mode , so after 30 seconds it checks the dialout selection list f or the High W ater input.
Boat Remote User ’ s Man ual 70 2) The unit is operating in Aw ay Mode , so after 30 seconds it checks the dialout selection list f or the AC P ower input. It then dials the first number on the list (phone #1, Marina office, 555-1111). 3) The Marina office is closed at night so the unit receives no ans wer and hangs up.
Chapter 4: Operation 71 until the alarm is acknowledged. Since Boat Remote is in On-Board Mode, an alarm dial out will not occur . The red warning LED will continue to blink and the alarm condition will continue to be dis- played on the LCD screen.
Boat Remote User ’ s Man ual 72 59.5 degrees Fahrenheit/Celsius. or T emperature #2(def ault v oice message for T emp #2 input) is 59.5 degrees Fahrenheit/Celsius. The ocean water temperature (recorded message f or T emp #3 input) is 55.8 degrees Fahrenheit/Celsius.
Chapter 5: T roubleshooting 73 I n the event that a problem is encountered, this section will assist you in determining the cause so you can return the unit to its usual monitoring routine with minimal interruption.
Boat Remote User ’ s Man ual 74 SOLUTION: Program some numbers in the call selection list. CA USE: Brok en wires, touching wires or a f aulty sensor . SOLUTION: Inspect the wiring and test the sensor operation with a continuity tester or ohmmeter . PROBLEM: The Boat Remote fails to dial out.
Chapter 5: T roubleshooting 75 SYSTEM menu and adjust if necessary . CA USE: The Boat Remote is connected to an incompatible tele- phone line. SOLUTION: Some telephone systems will not allow the telephone to ring bey ond 4 r ings . If y our Boat Remote ’ s Rings Until Answ er is set at more than 4 rings you ma y not be able to access the unit.
Boat Remote User ’ s Man ual 76 SOLUTION: Replace the temperature sensor with a 10K sensor from Phonetics or an approved alternate source. O THER MONIT ORING PROBLEM: The alarm status of the security or auxiliary input is incorrect. CA USE: The input nor mality , open/closed, is incorrect.
Chapter 5: T roubleshooting 77 SOLUTION: Replace the AC power fuse , see Fig 2.2 in Chapter 2. The fuse is rated at 1.5 Amps and is siz e 2AG. PROBLEM: The Boat Remote does not recognize any alarm. CA USE: The Boat Remote is in standby mode . SOLUTION: Press the MODE button to change to ON-BOARD or A WA Y MODE.
Boat Remote User ’ s Man ual 78.
TEMP#1, #2, & #3 AC POWER High Limit: +160 deg F max. Mode: Activ e, Off, Status-Only Low Limit: -20 deg F min. Rec Time: 0m, 0s - 999m, 59s Mode: Active, Off , Status-Only Phone Selection: 1-8 Re.
MODE Key 1) T oggles between Standby , Onboard & A wa y modes. 2) T oggles between parameter options from within a menu. ENTER Key Used to enter programming changes or to clear parameters. DO WN ARRO W K ey 1) Scrolls through the idle status screens.
Appendix B: Checking f or Proper Operation 81 APPENDIX B: Chec king Y our Boat Remote for Pr oper Op- eration We recommend that y ou test your Boat Remote w eekly to be sure it is functioning properly . This will ensure that when a problem arises the Boat Remote will be ready to alert the appropr iate personnel.
Boat Remote User ’ s Manual 82.
Appendix C: Engineering Specifications 83 I. General The A utomatic dialer shall be a self-contained microprocessor controlled system capable of monitoring 10 alarm channels. The system shall be configured for operation by the user by means of the built-in k eypad.
Boat Remote User ’ s Man ual 84 allow local keypad programming of pertinent operational data including, but not limited to: 1. High and Low Limits (temperature, battery voltage) 2. Maximum continuous run-time (Bilge pumps) 3. Maximum cycle rate (Bilge pumps) 4.
Appendix C: Engineering Specifications 85 C . V oice Messages The system shall have the ability to record, store and reproduce voice messages to articulate the location and status of the moni- tored channels. In absence of user-recorded messages, the system shall articulate channel status using the internally resident vocabu- lary .
Boat Remote User ’ s Man ual 86 VI. Enclosure, Environmental and Power A. Enclosure The system shall be housed in a blac k ABS plastic enclosure with keyholes on the back for wall mounting. Field wiring shall enter the enclosure through a slot in the back or may also enter through a knock out on the bottom end of the enclosure.
Appendix C: Engineering Specifications 87 G. Maintenance The system manufacturer shall have in-house service facilities and technical assistance available during normal business hours (EST). Specifications subject to change without notice. Copyright 1995 Phonetics, Inc.
Boat Remote User ’ s Man ual 88.
Appendix D: Returning Y our Unit for Repair 89 In the e vent that the Boat Remote does not function properly , we suggest that you do the following: 1.
Boat Remote User ’ s Man ual 90.
Ein wichtiger Punkt beim Kauf des Geräts Phonetics Boat Remote (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Phonetics Boat Remote noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Phonetics Boat Remote - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Phonetics Boat Remote reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Phonetics Boat Remote erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Phonetics Boat Remote besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Phonetics Boat Remote verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Phonetics Boat Remote. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Phonetics Boat Remote gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.