DE
Philips logo
Offizielle Bedienungsanleitung

Philips SC580

100 Seiten·2.1 MB·Luftbefeuchter·PDF·ENJA
Philips SC580
Inhaltsverzeichnis 13 Abschnitte Humidifier · SC580 SBC · √‰ËÁ %˜ ¯Ú‹Û˘ ∂ÏÏËÓÈο 60 · Helpline (www.p4c.philips.com) · … AnzeigenAusblenden
Page 1 of the Philips SC580 user manual — √‰ËÁ %˜ ¯Ú‹Û˘ ∂ÏÏËÓÈο 60
Seite 1 · Zum Vergrößern klicken
Seite 1
Philips SC580 — Humidifier diagram (page 1)
Abb. 1 · Humidifier

Humidifier

SC580 SBC

Instructions for use English 4

Instructions pour l’utilisation Français 12

Modo de empleo Español 20

Istruzioni per l’uso Italiano 44

Instruções de uso Português 52

√‰ËÁ %˜ ¯Ú‹Û˘ ∂ÏÏËÓÈο 60

Philips SC580 — √‰ËÁ %˜ ¯Ú‹Û˘ ∂ÏÏËÓÈο 60 diagram (page 1)
Abb. 2
Philips SC580 — √‰ËÁ %˜ ¯Ú‹Û˘ ∂ÏÏËÓÈο 60 diagram (page 1)
Abb. 3
Philips SC580 — √‰ËÁ %˜ ¯Ú‹Û˘ ∂ÏÏËÓÈο 60 diagram (page 1)
Abb. 4
Philips SC580 — √‰ËÁ %˜ ¯Ú‹Û˘ ∂ÏÏËÓÈο 60 diagram (page 1)
Abb. 5
Show 6 more labels / short text on this page
Bedienungsanleitung Deutsch 28 · Gebruiksaanwijzing Nederlands 36 · Bruksanvisning Svenska 68 · Vejledning Dansk 76 · Bruksanvisning Norsk 84 · Käyttöohje Suomi 92
Page 2 of the Philips SC580 user manual — Helpline (www.p4c.philips.com)
Seite 2 · Zum Vergrößern klicken
Seite 2

☎

Helpline (www.p4c.philips.com)

België & Luxemburg/ Belgien & Luxemburg/ Belgique & Luxembourg (Belgium & Luxembourg) Tel: 070 222303

Nederland (Netherlands) Phone0900 8406
Norge (Norway) Phone2274 8250
Danmark (Denmark) Tlf808 82814
Österreich (Austria) Phone0810 001203
Deutschland (Germany) Phone0180 53 56 767
Portugal Phone2416 3033
España (Spain) Phone902 11 33 84

Schweiz/ Suisse/ Svizzera (Switzerland) Tel.: 0844 800 544

France Phone08 25 88 97 89

Suomi (Finland) puh. 09 615 80 250

ŒÏÏËÓ·˜ (Greece) Phone00800 3122 1280
Sverige (Sweden) Phone08 598 522 50
Ireland Phone01 764 0292
UK (United Kingdom) Phone0870 9009070
Italia (Italy) Phone199118899
Philips SC580 — Helpline (www.p4c.philips.com) diagram (page 2)
Abb. 6 · Helpline (www.p4c.philips.com)
Philips SC580 — Helpline (www.p4c.philips.com) diagram (page 2)
Abb. 7 · Helpline (www.p4c.philips.com)
Page 3 of the Philips SC580 user manual — B) Hygrometer/thermometer
Seite 3 · Zum Vergrößern klicken
Seite 3
Philips SC580 — A) Humidifier diagram (page 3)
Abb. 8 · A) Humidifier
Philips SC580 — A) Humidifier diagram (page 3)
Abb. 9 · A) Humidifier
Philips SC580 — A) Humidifier diagram (page 3)
Abb. 10 · A) Humidifier
Philips SC580 — A) Humidifier diagram (page 3)
Abb. 11 · A) Humidifier
Philips SC580 — A) Humidifier diagram (page 3)
Abb. 12 · A) Humidifier
Philips SC580 — A) Humidifier diagram (page 3)
Abb. 13 · A) Humidifier
Philips SC580 — A) Humidifier diagram (page 3)
Abb. 14 · A) Humidifier
Philips SC580 — A) Humidifier diagram (page 3)
Abb. 15 · A) Humidifier
Philips SC580 — A) Humidifier diagram (page 3)
Abb. 16 · A) Humidifier
Philips SC580 — A) Humidifier diagram (page 3)
Abb. 17 · A) Humidifier

A) Humidifier

Philips SC580 — A) Humidifier diagram (page 3)
Abb. 18 · A) Humidifier
Philips SC580 — A) Humidifier diagram (page 3)
Abb. 19 · A) Humidifier

B) Hygrometer/thermometer

Page 4 of the Philips SC580 user manual — SBC SC580
Seite 4 · Zum Vergrößern klicken
Seite 4

Your humidifier

SBC SC580

Philips is dedicated to producing caring, reliable products that new fathers and mothers really need. Products whose reliability and operating quality bring reassurance.Your SC580 humidifier helps to improve the air quality of your baby’s room by adding moisture to the air to establish a comfortable humidity level. A correct humidity level helps to protect your baby from irritation of the mucous membranes, dry and itchy skin, chapped lips and dry, sore throat. When the mucous membranes do not function optimally they cannot give your baby full protection from all kinds of germs.This increases the chance of your baby catching a cold or the flu and reduces the baby’s resistance to infection by mould and bacteria.

Relative humidity level People need a certain level of humidity to feel comfortable. Using a humidifier helps you to keep indoor humidity at a comfortable level. A humidity level between 40 and 60 percent is recommended. A humidity level below 30 percent can be dry and uncomfortable. The hygrometer/thermometer supplied enables you to check humidity and temperature at regular times. The amount of water vapour in the air is usually less than is required to saturate the air. Relative humidity is the amount of water vapour in the air compared to the amount of water vapour the air can hold at the current temperature.

Working principle of your SC580 Your SC580 humidifier uses an ultrasonic, high-frequency oscillator to break up the water into tiny particles.The ventilation system blows out these water particles (mist) into the dry air where they evaporate to ensure the required humidity.The great advantage of the ultrasonic technique is that it operates extremely silently without affecting the room temperature or steaming up windows, walls or furniture. Your humidifier holds about 2 litres of water in the tank and produces up to 250 ml of moisture per hour, depending on the room humidity and temperature.

Philips Baby Care,Taking care together

Page 5 of the Philips SC580 user manual — Important information
Seite 5 · Zum Vergrößern klicken
Seite 5

Important information

Please read these instructions for use carefully before using your humidifier, and keep them for future reference.

  • Safety precautions
  • Any modifications or adjustments to your humidifier without our company’s authorization may cause inconvenience and harm to the user.
  • Switch off the unit and disconnect from the mains immediately if the unit produces a strange smell or an abnormal noise. If repair is needed, it must be done by qualified personnel.
  • Switch off the unit and unplug from the mains before moving or cleaning the unit.
  • Do not switch on your humidifier when there is no water in the water tank.
  • Do not use any metal or hard objects to clean the oscillator.
  • Do not put your humidifier into water, or let water get into the base unit.
  • The mist output should not be directed towards furniture or electrical appliances.
  • Keep your humidifier at normal room temperature, and do not use it at very low temperatures (< 0°C).
  • Make sure the mains lead is always out of reach of your baby, at least one metre away.
  • Check that the voltage indicated on the type plate corresponds to the local mains voltage before connecting to the mains supply.
  • To avoid fire hazard, never put the cord under rugs, or near radiators, stoves, or heaters.
  • Do not use your humidifier in damp places or close to water.
  • Do not use your humidifier in an area where the humidity level exceeds 50 percent.
  • Do not expose your humidifier to extreme heat or light (eg. direct sunlight).
  • Do not use your humidifier outdoors.
  • Use your humidifier only for intended household use as described in these instructions for use.
  • Disconnect your humidifier from the mains when not in use.
  • Never tilt, move, or attempt to empty your humidifier while it is operating.

Packaging contents – Humidifier – Thermometer/hygrometer – Instructions for use

Page 6 of the Philips SC580 user manual — B) Hygrometer/thermometer 15 Humidity indicator 16 Temperature indicator
Seite 6 · Zum Vergrößern klicken
Seite 6
Environmental information No unnecessary packaging material has been used. Please observe the local regulations regarding the disposal of packing materials and old equipment. Contents Help line 2 General 4 Important information 5-6 Functional overview 6-7 Operating your humidifier 7-8 Maintenance 9 Problem solving 10 Technical specifications 11 Functional overview

A) Humidifier 1 Rotatable cover 2 Mist outlet 3 Handle 4 Water tank 5 Sterilizer Disinfects the water. 6 Security switch Switches off the oscillator when the water level becomes too low. 7 Power light 8 Base unit 9 ON/OFF switch / mist output control – Switches the humidifier on and off. – Controls oscillation speed/mist output. 10 Tip-over switch Switches off the oscillator when your humidifier is not levelled. 11 Mains lead 12 Water basin 13 Oscillator Breaks up the water into tiny particles. 14 Water tank cap / water outlet – Closes water tank. – Controls water flow to water basin and oscillator.

inside flap.

B) Hygrometer/thermometer 15 Humidity indicator 16 Temperature indicator

Legend of product · illustration on

Page 7 of the Philips SC580 user manual — Operating your humidifier
Seite 7 · Zum Vergrößern klicken
Seite 7

Operating your humidifier

  • Preparation
  • When using your humidifier for the first time, place it in the room where it is going to be used half an hour before switching on.
  • Place your humidifier on a smooth, flat and stable surface.
  • Make sure the water basin (12) is clean and free of foreign objects.
  • Recommended room temperature for babies is between 16 and 20 ºC with a relative humidity between 40 and 60%.
  • Check the air humidity on the hygrometer supplied. If the humidity level drops below 40 percent, follow the instructions below to humidify the air.

Operation 1 Be sure your humidifier is disconnected from the mains and the ON/OFF switch (9) is in the OFF position.

2 Remove the cover (1) from the water tank (4).

3 Remove the water tank (4) from the base unit (8) by holding the tank handle (3) and lifting straight upward.

4 Place the water tank upside down, twist off the tank cap (14) by turning anticlockwise and fill the tank with water. Use clean water.Tap water can be used, but the use of boiled or distilled water is preferred.Water temperature should not exceed 40º C.

5 Replace the tank cap (14) by firmly turning clockwise and then replace the water tank (4) onto the base unit (8). > The tank will immediately begin to transfer water into the water basin (12).

6 Place the cover (1) back onto the water tank (4). The cover can be rotated so that the mist outlet (2) can be placed in any required position.

7 Connect the mains lead (11) to a mains socket. Connect directly into the mains socket and fully insert the plug.

Page 8 of the Philips SC580 user manual — Operating your humidifier
Seite 8 · Zum Vergrößern klicken
Seite 8

8 Switch on your humidifier by turning the ON/OFF switch (9) clockwise until you hear a click. > The Power light (7) lights up orange.Your humidifier is now operative.

  • By turning the ON/OFF switch (9) clockwise/anticlockwise you can regulate the mist output of your humidifier.

9 Switch off your humidifier when the required humidity level has been reached (between 40 and 60 percent). The humidity level can be checked on the humidity indicator (15) on the hygrometer/thermometer. Turn the ON/OFF switch (9) anticlockwise until you hear a click. > The Power light (7) goes out.Your humidifier is now switched off.

10 Disconnect the mains lead (11) from the mains socket.

Notes: – Do not refill your humidifier without first disconnecting from the mains socket. Be sure to pull by the plug and not by the lead. – If your humidifier is not going to be used for two or more days, make sure any residual water is drained from the water tank (4) and water basin (12) to prevent algae or bacteria growth.

  • Automatic switch off
  • The security switch (6) automatically switches off the oscillator (13) when the water level is too low.
  • The tip-over switch (10) automatically switches off the oscillator (13) when your humidifier is tilted. > This protects the oscillator from overheating. In both cases your humidifier is still powered and the ventilator is still operating.
Page 9 of the Philips SC580 user manual — Maintenance
Seite 9 · Zum Vergrößern klicken
Seite 9

Maintenance

Your product requires regular maintenance! The frequency of maintenance depends on the average daily use of your humidifier and the water hardness of your area.The hardness of the water is determined by the amount of calcium and magnesium it contains. Too much calcium and magnesium in the water causes scale in the water basin, water tank and on the oscillator.This will prevent your humidifier from operating properly.Therefore, the scale needs to be removed as it becomes noticeable.

  • Tips for avoiding scale
  • Use cold boiled water or distilled water. Water temperature should not exceed 40 ºC.
  • Clean oscillator (13), water tank (4) and water basin (12) weekly.
  • Refresh the water in the water tank (4) each time you use your humidifier.
  • Clean your complete humidifier, drain the water from water tank (4) and water basin (12) and dry all parts with a soft, dry cloth when you are not going to use your humidifier for a long time.

Descaling your humidifier 1 Disconnect your humidifier from the mains and set the ON/OFF switch (9) to the OFF position. 2 Fill the water basin (12) with water and white vinegar. Leave the water/vinegar in for at least 4 hours (preferably one night). 3 Then clean off the scale with a soft cloth. 4 Rinse all parts with clean water.

  • Cleaning your humidifier
  • Disconnect your humidifier from the mains and set the ON/OFF switch (9) to the OFF position.
  • All parts of your humidifier, except the base unit (8) can be washed with water and soap or in a dishwasher.
  • Clean the inner part of the water tank (4) by filling it with water, firmly tightening the tank cap (14) and shaking the tank repeatedly.
  • Do not immerse the base unit (8), mains lead (11), or plug in water or any other liquid. Clean the base unit with a damp cloth.
  • Do not use cleaning or scouring agents.
  • Do not use any metal or hard objects to clean the oscillator.
Page 10 of the Philips SC580 user manual — Maintenance
Seite 10 · Zum Vergrößern klicken
Seite 10
Problem solving If a fault occurs, first check the points listed below. If you are unable to remedy a problem by following these hints, contact the helpline or consult your dealer. Under no circumstances should you try to repair your humidifier yourself as this might create harmful situations and will invalidate the guarantee. Possible cause Solution Humidifier not (properly) connected (Properly) connect the mains lead (12) to the mains supply. to a mains socket and switch on your humidifier. Water tank (4) is empty or Fill water tank (4) with clean water. water level is too low. Humidifier is brand new. Leave water tank (4) opened for at least 12 hours in a cold place. Water is dirty or kept too long Clean water tank (4) and refresh water. in the water tank (4). Too much water in water basin (12). Drain water from water basin (12). Close water tank cap/water outlet (14) firmly.

Humidifier produces Scale on oscillator (13). Descale oscillator (13). too little mist

Water is dirty or kept too long Clean water tank (4) and refresh water. in water tank (4).

Strange noises Water level is too low. Make sure the water tank (4) is sufficiently when humidifier is filled. operating

Humidifier placed on unstable surface. Place humidifier on a smooth, flat and stable surface.

Page 11 of the Philips SC580 user manual — Technical specifications
Seite 11 · Zum Vergrößern klicken
Seite 11

Technical specifications

Power supply: 220-240V AC Standard output: 250 ml per hour Water tank volume: 2 litres Noise level: < 35 dB (A) Frequency: 50-60 Hz Power: 35 W Dimensions: Ø 240 x 330 mm Net weight / gross weight: 2.5 kg / 3.3 kg Temperature measurement range: 0-50 °C Relative humidity measurement range: 30% RH - 80% RH

Need Help? If you have any questions about the SBC SC580, please contact our helpline for assistance! You can find the number in the list on page 2.

Before you call, please read this manual carefully. You will be able to solve most of your problems.

The model number of the humidifier is SBC SC580.

Date of purchase_____ /_____ /______ day /month /year

Frage zu Philips SC580 stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Philips SC580

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Philips SC580 PDF-Anleitung

100 Seiten·2.1 MB·Luftbefeuchter·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…