Page 1 of the Philips BGD602 user manual — DISCRETE SEMICONDUCTORS
Seite 1 · Zum Vergrößern klicken
Seite 1

DISCRETE SEMICONDUCTORS

DATA SHEET

BGD602 CATV amplifier module

Product specification File under Discrete Semiconductors, SC16

Philips Semiconductors

Page 2 of the Philips BGD602 user manual — QUICK REFERENCE DATA
Seite 2 · Zum Vergrößern klicken
Seite 2

FEATURES

PINNING - SOT115J

  • Excellent linearity

PIN DESCRIPTION

  • Extremely low noise
  • Silicon nitride passivation

7 8 9 2 3 5 1

  • Rugged construction
  • Gold metallization ensures excellent reliability.

5 +VB 7 common

Fig.1 Simplified outline.

DESCRIPTION

Hybrid high dynamic range amplifier module designed for applications in CATV systems with a bandwidth of 40 to 600 MHz operating with a voltage supply of 24 V (DC).

QUICK REFERENCE DATA

SYMBOLPARAMETERCONDITIONSMIN.MAX.UNIT G ppower gainf = 50 MHz1819dB f = 600 MHz19−dB I tottotal current consumption (DC)V = 24 V B−435mA

LIMITING VALUES In accordance with the Absolute Maximum Rating System (IEC 134).

SYMBOLPARAMETERMIN.MAX.UNIT V iRF input voltage−65dBmV T stgstorage temperature−40+100°C T mboperating mounting base temperature−20+100°C
Show 7 more labels / short text on this page
1 input · fpage · 2 common · 3 common · Side view MSA319 · 8 common · 9 output
Page 3 of the Philips BGD602 user manual — CHARACTERISTICS
Seite 3 · Zum Vergrößern klicken
Seite 3

CHARACTERISTICS Bandwidth 40 to 600 MHz; VB = 24 V; Tmb = 35 °C; ZS = ZL = 75 Ω.

SYMBOLPARAMETERCONDITIONSMIN.MAX.UNIT G ppower gainf = 50 MHz1819dB f = 600 MHz19−dB SLslope cable equivalentf = 40 to 600 MHz0.22.2dB FLflatness of frequency responsef = 40 to 600 MHz−±0.3dB S 11input return lossesf = 40 to 80 MHz20−dB f = 80 to 160 MHz19−dB f = 160 to 600 MHz18−dB S 22output return lossesf = 40 to 80 MHz20−dB f = 80 to 160 MHz19−dB f = 160 to 600 MHz18−dB S 21phase responsef = 50 MHz−45+45deg CTBcomposite triple beat85 channels flat; V = 44 dBmV; o measured at 595.25 MHz−−62dB X modcross modulation85 channels flat; V = 44 dBmV; o measured at 55.25 MHz−−66dB CSOcomposite second order distortion85 channels flat; V = 44 dBmV; o measured at 596.5 MHz−−60dB d 2second order distortionnote 1−−70dB V ooutput voltaged = −60 dB; note 2 im63−dBmV Fnoise figuref = 600 MHz−8dB I tottotal current consumption (DC)note 3−435mA
1. f p = 55.25 MHz; V p = 44 dBmV; f q = 541.25 MHz; V q = 44 dBmV; measured at f p + f q = 596.5 MHz.
2. Measured according to DIN45004B: f p = 590.25 MHz; V p = V o ; f q = 597.25 MHz; V q = V o − 6 dB; f r = 599.25 MHz; V r = V o − 6 dB; measured at f p + f q − f r = 588.25 MHz.
3. The module normally operates at V B = 24 V, but is able to withstand supply transients up to 30 V.
Page 4 of the Philips BGD602 user manual — CHARACTERISTICS
Seite 4 · Zum Vergrößern klicken
Seite 4

CHARACTERISTICS Bandwidth 40 to 550 MHz; VB = 24 V; Tmb = 35 °C; ZS = ZL = 75 Ω.

SYMBOLPARAMETERCONDITIONSMIN.MAX.UNIT G ppower gainf = 50 MHz1819dB f = 550 MHz18.8−dB SLslope cable equivalentf = 40 to 550 MHz0.22.2dB FLflatness of frequency responsef = 40 to 550 MHz−±0.3dB S 11input return lossesf = 40 to 80 MHz20−dB f = 80 to 160 MHz19−dB f = 160 to 550 MHz18−dB S 22output return lossesf = 40 to 80 MHz20−dB f = 80 to 160 MHz19−dB f = 160 to 550 MHz18−dB S 21phase responsef = 50 MHz−45+45deg CTBcomposite triple beat77 channels flat; V = 44 dBmV; o measured at 547.25 MHz−−66dB X modcross modulation77 channels flat; V = 44 dBmV; o measured at 55.25 MHz−−68dB CSOcomposite second order distortion77 channels flat; V = 44 dBmV; o measured at 548.5 MHz−−62dB d 2second order distortionnote 1−−72dB V ooutput voltaged = −60 dB; note 2 im64−dBmV Fnoise figuref = 550 MHz−7.5dB I tottotal current consumption (DC)note 3−435mA
1. f p = 55.25 MHz; V p = 44 dBmV; f q = 493.25 MHz; V q = 44 dBmV; measured at f p + f q = 548.5 MHz.
2. Measured according to DIN45004B: f p = 540.25 MHz; V p = V o ; f q = 547.25 MHz; V q = V o − 6 dB; f r = 549.25 MHz; V r = V o − 6 dB; measured at f p + f q − f r = 538.25 MHz.
3. The module normally operates at V B = 24 V, but is able to withstand supply transients up to 30 V.
Page 5 of the Philips BGD602 user manual — CHARACTERISTICS
Seite 5 · Zum Vergrößern klicken
Seite 5

CHARACTERISTICS Bandwidth 40 to 450 MHz; VB = 24 V; Tmb = 35 °C; ZS = ZL = 75 Ω.

SYMBOLPARAMETERCONDITIONSMIN.MAX.UNIT G ppower gainf = 50 MHz1819dB f = 450 MHz18.6−dB SLslope cable equivalentf = 40 to 450 MHz0.21.8dB FLflatness of frequency responsef = 40 to 450 MHz−±0.3dB S 11input return lossesf = 40 to 80 MHz20−dB f = 80 to 160 MHz19−dB f = 160 to 450 MHz18−dB S 22output return lossesf = 40 to 80 MHz20−dB f = 80 to 160 MHz19−dB f = 160 to 450 MHz18−dB S 21phase responsef = 50 MHz−45+45deg CTBcomposite triple beat60 channels flat; V = 46 dBmV; o measured at 445.25 MHz−−67dB X modcross modulation60 channels flat; V = 46 dBmV; o measured at 55.25 MHz−−66dB CSOcomposite second order distortion60 channels flat; V = 46 dBmV o measured at 446.5 MHz−−60dB d 2second order distortionnote 1−−75dB V ooutput voltaged = −60 dB; note 2 im67−dBmV Fnoise figuref = 450 MHz−7dB I tottotal current consumption (DC)note 3−435mA
1. f p = 55.25 MHz; V p = 46 dBmV; f q = 391.25 MHz; V q = 46 dBmV; measured at f p + f q = 446.5 MHz.
2. Measured according to DIN45004B: f p = 440.25 MHz; V p = V o ; f q = 447.25 MHz; V q = V o − 6 dB; f r = 449.25 MHz; V r = V o − 6 dB; measured at f p + f q − f r = 438.25 MHz.
3. The module normally operates at V B = 24 V, but is able to withstand supply transients up to 30 V.
Page 6 of the Philips BGD602 user manual — LIFE SUPPORT APPLICATIONS
Seite 6 · Zum Vergrößern klicken
Seite 6

DEFINITIONS

Data sheet status Objective specificationThis data sheet contains target or goal specifications for product development. Preliminary specificationThis data sheet contains preliminary data; supplementary data may be published later. Product specificationThis data sheet contains final product specifications. Limiting values Limiting values given are in accordance with the Absolute Maximum Rating System (IEC 134). Stress above one or more of the limiting values may cause permanent damage to the device. These are stress ratings only and operation of the device at these or at any other conditions above those given in the Characteristics sections of the specification is not implied. Exposure to limiting values for extended periods may affect device reliability. Application information Where application information is given, it is advisory and does not form part of the specification.

LIFE SUPPORT APPLICATIONS

These products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably be expected to result in personal injury. Philips customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Philips for any damages resulting from such improper use or sale.

Frage zu Philips BGD602 stellen

Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Noch keine Fragen zu Philips BGD602

Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.

Originaldokument

Philips BGD602 PDF-Anleitung

6 Seiten·21 KB·Stereoverstärker·PDF
Klicken Sie oben auf eine Seite, um sie hier zu öffnen
Seite 1 / …
100%
Seiten werden geladen…