This manual supports the field service maintenance and repair of the HD3 Ultrasound System.
The user of this document is a qualified ultrasound electronics technician who has completed
Acrobat Reader. A list of bookmarks functions as an additional table of contents. Those book-
employee on equipment located at the customer’s designated site. Use of this document by
Manual Format This manual is in Portable Document Format (PDF), for viewing on a laptop computer with
purchased a valid service agreement for use by the customer’s designated in-house service
user is no longer licensed and in any event upon Philips’ first written request.
in the sequence they are presented to ensure reliable results.
in This Manual The following conventions are used in this manual:
training classes on the system and its peripherals.
referenced information.
Copyright © 2005 Koninklijke Philips Electronics N.V. All rights reserved
4535 612 34161 Rev A August 2005
HD3
CSIP Level 1

CSIP Level 1 About This Manual
Assistance Various support locations around the world can provide customers technical assistance with the
ultrasound system. Customers should contact the representative or sales office from which they
If you have questions about the service manual, or you discover an error in the manual, contact
purchased the system or the nearest Philips Ultrasound office.
Philips Ultrasound Technical Communications:
22100 Bothell-Everett Highway Bothell, WA 98021-8431
425-487-7000 or 800-426-2670 www.medical.philips.com
a sequential procedure.
appear in bold text.
Service Manual
or Comments
Questions
Customer
Philips Ultrasound

CSIP Level 1 About This Manual
This document and the information contained in it is proprietary and confidential information of Philips Medical Systems (“Philips”)
and may not be reproduced, copied in whole or in part, adapted, modified, disclosed to others, or disseminated without the prior
written permission of the Philips Legal Department. Use of this document and the information contained in it is strictly reserved
designated in-house service employee on equipment located at the customer’s designated site. Use of this document by unautho-
rized persons is strictly prohibited. Report violation of these requirements to the Philips Legal Department. This document must
Philips provides this document without warranty of any kind, implied or expressed, including, but not limited to, the implied war-
Philips has taken care to ensure the accuracy of this document. However, Philips assumes no liability for errors or omissions and
reserves the right to make changes without further notice to any products herein to improve reliability, function, or design. Philips
for current Philips personnel and Philips customers who have a current and valid license from Philips for use by the customer’s
be returned to Philips when the user is no longer licensed and in any event upon Philips’ first written request.
may make improvements or changes in the products or programs described in this document at any time.
Non-Philips product names may be trademarks or registered trademarks of their respective owners.
“HD3”, “Chroma” and “Color Power Angio” are trademarks of Koninklijke Philips Electronics N.V.
ranties of merchantability and fitness for a particular purpose.






















down of the system functional elements and a description of their relationships and basic
Introduction This section describes the contents of this manual and provides the following information:
tion of this system and that you will operate it as intended.
principles of operation (how the system works).
as the HD3 system or the system)
This manual is organized as follows:
instructions for the system.
Getting Started manual.
document.
More About
This Manual

tem, identifies the primary system electronics, and shows where each circuit board is located
detailed procedure, the means of removing a system part can be discerned from the illustra-
system monitor. There are no calibration or alignment adjustments to make in the field for
audit (QAA) concept that you should perform in accordance with Customer Field Service
tions in this section as well as from those in Section 13, “Configuration” and in Section 14,
in the system. When applicable, additional circuit board reference information is provided.
ensure that the system is operating as intended at initial installation and after upgrades or
be required for the removal and installation of field-replaceable parts. If not covered by a
this system. There are no voltage adjustments to make in the field for this system.
number information, and (sold-with-system) peripheral connection diagrams.
restoring, software and device driver loading, and managing system options.
“Parts”. Instructions for crating the system for shipment are also included.
with specific software releases.
repairs.
policy.

The HD3 system, shown in Figure 1-1, is intended for general imaging. The cart is ergonomically
sionals. The system has a basic set of imaging modes and measurement tools and supports up to
boards and certain hardware assemblies). Call your Philips representative for the core infor-
designed to be both highly mobile and adjustable for a range of users and operating conditions.
HD3 operators can measure anatomical structures and generate reports for health-care profes-
five transducers. There are optional modes and measurement tools that are available only when
a specific mode or an analysis package is purchased and enabled for customer use. Options and
parts that are not dependent upon system features and software versions (primary circuit
mation you need to determine the compatibility of primary system PCBs and certain hard-
upgrade security is controlled through the use of system-specific passwords and software.
The HD3 system uses an embedded computer featuring the Linux operating system.
ware assemblies with respect to the system software releases.
ducers that can be used with the HD3 system.
System



Figure 1-1 HD3 Ultrasound System

Modes The following imaging modes are available on the HD3 system. Refer to the HD3 Getting Started
Applications The following applications are available on the HD3 system. Refer to the HD3 Getting Started
manual for detailed feature information regarding these applications:
manual for detailed feature information regarding these modes:

Transducers The system has two electronically-switched transducer connectors. The following five transduc-
Languages The system software supports the following languages at initial release:
ers are supported (also see Section 15, “Transducers”):

each system can have whatever software options the customer purchases enabled at the factory
loaded into every system and because most of the system options are “software only” features,
Options The HD3 system software contains all of the available software options. The same software is
or, with the correct key-codes, on site. Purchased hardware options are shipped with the sys-
The following options are available for this system at initial release:
See “Peripherals” on page 32.
Software Options
tem.
tem shipped) · shipped)

Peripherals The HD3 system supports the following peripheral devices (these are optional unless noted as
in the system software, but these printers cannot be purchased from Philips. Print drivers
may be added to support additional report printers as they are released:
- HP Business Inkjet 1200
- HP DeskJet 895cxi
- HP DeskJet 880C
- HP LaserJet 1200
- HP Laserjet 1320
- HP DeskJet 6122
- HP DeskJet 5550
- HP Deskjet 5650
- HP DeskJet 6540
- HP DeskJet 6840
standard):


UP-895MD Sony Graphic Printer
Figure 1-2 HD3 Ultrasound System Image Printers and VCR
HS-MD3000UA/EA Mitsubishi Video Cassette Recorder


UP-21MD Sony Color Printer
(Black and White)


Figure 1-3 HD3 Ultrasound System Data Media

CD-RW Drive · USB MOD Drive


Figure 1-4 HD3 Ultrasound System Foot Switch

power circuits, software and data storage devices, and the system input/output (I/O) connection
Cart The cart is made up of a base and framework that provides a chassis on which all system compo-
The front casters can be fixed straight and locked, or unlocked, by foot-operated wheel locks to
The HD3 physical structure is made of fabricated sheet metal and molded plastic parts. The sys-
tem (Figure 1-1) consists of a cart, a user interface (control panel), a visual display (video moni-
tor), and the ultrasound electronic components. Other important physical components are the
See Section 4, “Theory of Operation” for a functional description of these system components.
Swivel-casters at the four corners of the cart base provide system maneuverability and braking.
Panel The control panel (Figure 1-5) is a replaceable, self-contained module.
mobilize or immobilize the system as needed.
nents are installed and interconnected.
panel.
Description
Physical

System Monitor The video monitor (Figure 1-1) is a non-interlace 26.4 cm (10.39-in) color TFT LCD display that
Components The physical components that comprise the primary ultrasound elements of the system are the
Transducer Connector Assembly and the E-box circuit boards. See Section 13, “Configuration”
is mounted on a mechanism that allows tilt and swivel positioning of the display.

for pictures and locations of these system components.
Figure 1-5 HD3 Ultrasound System Control Panel

The Transducer Connector Assembly (TCA) has the transducer connectors (contained in metal
The software and data storage components (Figure 1-3) are physically comprised of the hard disk
drive (HDD), CD-RW drive, and when installed, the optional magneto-optical disk (MOD) drive.
Components The system electronic power components are the Isolation Transformer, Power Supply, and the
The E-box is a card cage that houses the ultrasound signal generation and echo acquisition cir-
cuits. The following ultrasound system electronic circuits are contained in the E-box:
See Section 14, “Parts” for illustrations and locations of these system components.
shielding) that interconnect to the E-box Front End board.
Power I/O Assembly.
System Power
Software and
Data Storage
Components
boards)

For information about applicable safety standards and specifications, see the HD3 Getting Started
I/O Panel The I/O Panel, which provides connections for external devices, is installed into the rear of the
Cables Physical cables provide system signal interconnect and power distribution. Refer to Section 11,
Electrotechnical Commission (IEC), the Canadian Standard Association (CSA), and the Under-
The HD3 Ultrasound System complies with the following requirements for the International
cart framing (see Figure 11-5 for connection descriptions).
“Cabling”, for detailed cable information.
manual shipped with the system.
writers Laboratories (UL).
Device Safety
Regulatory
Compliance
and

This Philips ultrasound system may contain “open source” software. According to the terms
software and that you can order it for them if they want it. The part number for the HD3 system
Supplies and accessories are not available from Philips Ultrasound. The customer is directed to
which are open source software. The following notification is included in the customer’s Operat-
The “additional information” is that the customer is entitled to a copy of the operating system
The HD3 system uses an embedded computer featuring the Linux operating system, parts of
of the General Public License, a recipient may request a copy of any GPL-licensed source
code modules present in the system, for the cost of shipping and handling. Please contact
Transducer covers and other supplies and accessories can be ordered from CIVCO Medical
order biopsy guides by contacting their Philips representative or an authorized distributor.
your local customer service representative for additional information.
Open Source Software is 453561228511.
102 First St. South Kalona, IA 52247-9589
Instruments:
ing Notes:
Open Source
Accessories
Software
License
+1 319-656-4447 (International) · +1 319-656-4451 (International) · CIVCO Medical Instruments

Introduction This section summarizes the system specifications for the HD3 Ultrasound System. For trans-
The physical dimensions and weight of the HD3 are as follows:
The electrical specifications of the HD3 are as follows:
ducer specifications, see Section 15, “Transducers”.
Specifications
Electrical
Physical

- VCR and printers temperature limit: 10°C to +40°C (+50°F to +104°F) at 80% RH
Table 2-1 Embedded PC Hardware Specifications
The environmental specifications for the HD3 system are as follows:
Table 2-1 lists the PCC hardware specifications.
Memory 128 Synchronous DRAM Hard drive 80 GB VGA 640x480 ROM 2 Mbit Flash BIOS Network Interface 10/100 Mb/s Tx Keyboard PS/2
Specifications
System PC
Environ-
mental
Component Specification · OS Linux

Table 2-1 Embedded PC Hardware Specifications (Continued)
IDE port Enhanced IDE interface
The monitor specifications are:
Monitor
Component Specification · Mouse PS/2

The following image storage formats are supported by each HD3 storage device (Table 2-2):
Hard Drive X
Flash Memory X
MOD X X X X
Table 2-2 Supported Image Formats
Image
Device Format

In this manual, WARNING is used to indicate the presence of a hazard that can cause personal
In this manual, NOTE is used when additional comment or explanation is required about instal-
This system is intended for use by, or by the order of, and under the supervision of a licensed
Read the HD3 Getting Started for detailed safety and standards information for the HD3 Ultra-
sound System. This guide includes critical information about the intended uses of the HD3 sys-
sound system. It applies to the ultrasound system, transducers, recording devices, and any
In this manual, CAUTION is used to indicate the presence of a hazard that can cause equip-
Please read this and related information before using or servicing a Philips ultra-
tem, patient and operator safety, and device standards. This is information that maintenance
lation, operation, or maintenance information that is important but not necessarily haz-
Introduction This section summarizes the safety information for the HD3 Ultrasound System.
injury, death, or substantial property damage if the warning is ignored.
physician qualified to direct the use of the device.
ment damage if the caution is ignored.
personnel should be aware of.
optional equipment.
ard-related.
Information
Operating
General
Safety

with Type BF and Type CF isolated patient-applied parts and Type B accessories. For maximum
This equipment has been verified by a recognized third-party testing agency as a Class I device
toring devices, is not properly grounded. Protection against electrical shock is provided by
grounding the chassis with a three-wire cable and plug. The system must be plugged into a
Cabinet panels must be in place while the system is in use. All internal adjustments and
replacements must be made by a qualified Philips Ultrasound field service engineer.
grounded outlet. The grounding wire must not be removed or defeated.
a regular basis. Ensure that they are not damaged in any way.
result from electrical ignition.
safety observe these warnings:
before cleaning the system.
Safety

that could affect the ultrasound system performance. (Electrostatic discharges can cause the
ECG heart rate display to increase by 10% to 15% for a few seconds after the discharge, even
though the ECG heart rate display returns to normal within a few seconds. See “About Elec-
(EMI) that could impact the diagnosis of a patient. (Only a physician can determine if an arti-
face, housing, and cable before use. Do not use if the face is cracked, chipped, or torn; the
removed from the patient contact prior to application of a high-voltage defibrillation pulse.
shock. When such optional devices are connected to your ultrasound system, ensure that
fact caused by radiated interference has a negative impact on image quality and the subse-
the total system earth leakage current does not exceed 300 μA.
quent diagnosis.) See “Avoiding EMI and RF” on page 48.
housing is damaged; or the cable is abraded.
the specified cleaning or disinfection level.
trostatic Discharge” on page 51.)

and RF Although the system has been manufactured in compliance with existing EMI/EMC requirements,
use of this system in the presence of an electromagnetic field can cause momentary degradation
devices such as cellular phones and pagers can cause these emissions. The existence of radio, TV,
or microwave transmission equipment located nearby can cause emissions. In cases where EMI is
the RF range, ultrasound transducer circuits are susceptible to RF interference. While an ESU is
in use, the noise generated can severely interfere with the black-and-white image and completely
Electrosurgical units (ESUs) and other devices intentionally introduce radio frequency (RF) elec-
tromagnetic fields or currents into patients. Because imaging ultrasound frequencies are also in
being used, to identify possible sources of radiated emissions. These emissions could be from
of the ultrasound image. If this occurs often, review the environment in which the system is
other electrical devices used within the same room or an adjacent room. Communication
could damage the ultrasound system. (See “About Electrostatic Discharge” on page 51.)
causing disturbances, it may be necessary to relocate your system.
obliterate the color image.

Although the system is designed to be mobile, remember that it is very heavy, and that you must
of the system, disconnect the system power cord, and disconnect all external devices. Move
locks before moving the system. Push with the handle at the front of the cart. After the sys-
is heavy enough in any configuration that it can cause injury to you or others. Exercise addi-
attempt to hold the system in place manually. Never strap or secure the system at any point
take precautions when moving it. The physical aspects of this system present a hazard that can
cause injury, property damage, or equipment damage if the following information is ignored:
roll or tip. Engage the caster locks and use wheel chocks and restraining straps. Do not
tem is in position, engage the caster locks to immobilize the system.
cause it to tip over. Do not exceed 10 degrees of incline.
and secure external devices away from the system.
tional caution when going up or down inclines.
on the control top or monitor.
Safety

the cable management system to ensure that transducer cables are protected from damage.
that could damage the ultrasound system. See “About Electrostatic Discharge” on page 51.
Customer Service immediately. The components can withstand considerable shock, but
Follow these additional precautions to protect the system from damage:
excessive shock can cause a system failure.
dedicated solely for the ultrasound system.
Protection
General

The level of electrical energy discharged from a system user or patient to the ultrasound system
phenomenon. ESD is most prevalent during conditions of low humidity, which can be caused by
heating or air-conditioning. During low-humidity conditions, electrical charges naturally build up
An ESD condition occurs when an individual with an electrical energy buildup comes in contact
tions can help to reduce ESD: antistatic spray on carpets; antistatic spray on linoleum; antistatic
tent operation of the system. Take care not to run over cables with the system, which may
with objects such as metal doorknobs, file cabinets, computer equipment, and even other indi-
viduals. The static shock or ESD is a discharge of the electrical energy buildup from a charged
can be significant enough to cause damage to the system or transducers. The following precau-
static Discharge Electrostatic discharge (ESD), commonly referred to as a static shock, is a naturally occurring
specified in specific transducer cleaning instructions, do not immerse the remainder of a
mats; or a ground wire connection between the system and the patient table or bed.
tight beyond the applied part/cable or cable/connector interfaces.
individual to a lesser or non-charged individual or object.
ers, video monitor, touch screen, or any printer.
on individuals and can create static shocks.
transducer in any liquid.
damage them.

Symbols The International Electrotechnical Commission has established a set of symbols for medical elec-
tronic equipment that classify a connection or warn of potential hazards. The classifications and
Follow these general ESD guidelines to minimize deterioration or destruction of ESD-sensitive
electricity, take the necessary ESD precautions to avoid static buildup and discharge.
Isolated patient connection for applied parts in direct contact with
Identifies the On/Off button on the system control panel.
Isolated patient connection. (Type BF)
major vessels. (Type CF)
symbols are shown below.
electronic components:


electrical shock. This symbol indicates that the patient-applied part
Indicates that this device is protected against vertically falling water
immersion. This degree of protection can apply to transducers and
On the system AC Mains power switch, “ I “ represents on and
This symbol identifies a safety note. Ensure you understand the
function of this control before using it. Refer to the appropriate
Indicates that this device is protected against the effects of fluid
section of the system documentation for an explanation of the
The patient-applied part provides a degree of protection from
is defibrillator-proof. The patient-applied part is suitable for all
Identifies fuse location. For continued protection from fire or
shock, replace only with the same type and rating fuse.


This isolated output auxiliary power is provided for connection of
exposed pins can cause electrostatic discharge, which can damage
This product consists of devices that may contain lead or mercury,
equipment in compliance with the Waste Electrical and Electronic
Do not throw away. Dispose of in accordance with local, state, or
Indicates that interference may occur in the vicinity of equipment
which must be recycled or disposed of in accordance with local,
symbol to warn the user not to touch exposed pins. Touching





Identifies the point where the safety system ground is fastened to
terminals. It indicates the presence of voltages greater than 1,000
The following symbols are used inside the system:

The following symbols appear on the product packaging to indicate environmental consider-
Atmospheric pressure range of 700 to 1,060 hPa for transport and
Ambient temperature range -20°C to +60°C (-4°F to +140°F)
(noncondensing) for transport and storage. (Does not apply to
Relative humidity range of 20% to 90% (noncondensing) for
transport and storage.
storage.
media).
ations:

for storage, video, serial and parallel ports, and support of file system services and graphical user
CSIP Level 1 Theory of Operation: Introduction
A Linux operating system (OS) provides an integrated range of resources: drivers and handlers
Introduction This section provides a functional overview of the HD3 Ultrasound System by breaking down
the system into functional elements and describing their relationships and basic principles of
interfaces. The OS is resident on the hard drive. The system software performs these tasks:
The HD3 system architecture is made up of the following basic functional elements:
operation.
Operating
System
System
analog signals

images to a black-and-white printer, color printer, or to a VCR. It also generates reports that can
After operating power is applied, the major functional elements combine to produce ultrasound
ing, beamforming, continuous-wave and color Doppler processing, scan conversion, digital signal
boards, the TCA (page 63), the FE (page 63), the BF (page 63), the DSC (page 63), and the PCC
Figure 4-1 is a simplified block diagram of the HD3 system, showing the relationship between the
CSIP Level 1 Theory of Operation: Functional Description
The HD3 system produces ultrasound images using transducers, digital beamforming, and Dop-
components comprise digital beamformer technology that combines with the operating system
The HD3 system stores the ultrasound images and patient data on the hard drive and can copy
The overall system functional flow is power development and distribution, analog signal process-
(page 64). Most of the ultrasound signal processing, image processing, analysis, and display func-
tions are performed by software using the native processing power of the embedded computer
pler processing. The central processing unit of the system is the PCC Board. The ultrasound
CD-R/W disks, and USB flash memory sticks for off-system review. The system can send the
The HD3 system ultrasound engine physically and functionally comprises five primary circuit
that data to the removable media, such as magneto-optical drive (MOD) disks, CD-R and
primary circuit boards and indicating the major functional tasks performed by each.
images. The user interface allows system control and viewing of the results.
processing, and video and audio presentation.
to support the system functions.
of the PCC Board.
be printed.
Functional

CSIP Level 1 Theory of Operation: Functional Description

Processes all signals from the Beamformer
Generates 2D, Spectral and Color displays
Image save (to hard drive via PCC board
Blood velocity and direction calculation
Routes RGB to PCC board for display
Color filtering and calculation
16 channel A/D conversion
32 Channel TX pulser
I and Q data
BF FE
Figure 4-1 HD3 System Functional Block Diagram
Transducer connector assy connection
32 channel to 16 channel folding and reorder
128 channel high voltage switching
32 channel TGC amplifier
25 MHz system clock
MIC
USB
PCC
TCA
PSA

ultrasound electronic components. Other important physical components are the power circuts,
Information, Cabling , Configuration, and Parts sections of this document. The functional nature
CSIP Level 1 Theory of Operation: Functional Description
Functions The HD3 physical structure is made of fabricated sheet metal and molded plastic parts. The sys-
tem consists of a cart, a user interface (control panel), a visual display (video monitor), and the
The location and identification of the physical parts of the system are described in the General
System Power System power development and distribution is provided by the installation site source voltage,
the system isolation transformer, power supply, backplane power bus, and power interconnect
software and data storeage devices, and the system input/output (I/O) connection panel.
of each is described in the following paragraphs.
- 100-120 Vac ±10%
- 200-240 Vac ±10%
cables.
- 50/60 Hz

power supply from overcurrent load or short circuit conditions. Latched AC outputs will be
reset once the input power is cycled. The latched DC output will be reset if the input power
CSIP Level 1 Theory of Operation: Functional Description
turn-on surges). The AC input may be cycled to restore power.
System power distribution diagrams are shown in Figure 11-2.
The system power supply has these features:
- + HV (+ 20 to + 80 Vdc)
- - HV (- 20 to - 80 Vdc
- + 3.3 Vdc
- + 12 Vdc
- + 12 Vdc
- + 97 Vdc
- + 5 Vdc
- - 97 Vdc
- - 5 Vdc
is cycled.

tem interface for two transducers (see Section 15, “Transducer Information”). It works with the
identification and enable function, and downloads operational parameters from the PCC, provid-
the system include dynamic apodization, multiplication, coefficient loading, variable sample clock
The DSC Board is multi-functional, performing functions supported by separate circuit boards in
CSIP Level 1 Theory of Operation: Functional Description
The Transducer Connector Assembly (TCA) is the transducer select module, providing the sys-
FE Board for transducer detection and identification, engaging the appropriate number of relays
(BF) The Beamformer Board is responsible for generating and transmitting pulses for the transducer
elements. When the returning echoes come back into the system, they are sent in analog form
Board The Front End Board provides the physical and electrical interface to the TCA, the transducer
interconnects the FE and the BF boards) for processing, where they are filtered prior to being
The signal processing functions of digital beamforming that determine the real image quality of
larger systems. The DSC performs the functions of a digital signal processor, digital scan con-
through the FE to the Beamformer (via the Beamformer Connector Board that bridges and
converted into digital data. Once the data is digitized, specialized circuits perform the beam
ing real-time control of the transmit, receive, and beamforming functions.
to accommodate transmitting and receiving pulses and echoes.
verter and real time clock, and video manager.
- Calculates blood velocity and direction
- Receives all signals from BF board
generation, and dynamic gain control.
forming and steering.
Front End (FE)
Beamformer
Digital Scan
Transducer
Connector
Converter
(DSC)

central processing unit, performing further processing of the image data, including the generation
CSIP Level 1 Theory of Operation: Functional Description
PCC Board The PCC Board is similar to the motherboard used in a personal computer. The PCC acts as a
The PCC determines system functionality and coordinates the overall communication between
the user and the system, which includes storing and saving images. The PCC communicates con-
- Generates the 2D image, spectral Doppler spectrum and audio, Color and Power Dop-
pler image, and transmits these signals to the DSC part of the board and the I/O panel
When the DSC circuits receive ultrasound digital data from the DSP circuits, they perform
2D scan conversion and then transmit the video signals to the video management circuits.
of the image display to the screen. The PCC also serves as the main controller of the other
tinually with the hard drive for operating parameters and hosts the following functions:
boards and as the organizer of all of the image management functionality.
- Image Save (save image at HDD by PC)
- Color Keying (VGA data + image data)
- From DSC output to Main Monitor
- Post Mapping (control image curve)
- Edge Enhancement · - Dual Mode

engine. It is connected to the power supply, from which it receives DC operating voltages to dis-
The control panel consists of TGC slide pot controls, trackball, additional system control knobs
and buttons, and a QWERTY keyboard. An internal interface PCB reads all of the control inputs,
CSIP Level 1 Theory of Operation: Functional Description
Panel The I/O Panel at the rear of the system includes a circuit board that accomplishes the intercon-
The control panel (in conjunction with the monitor displays) is the primary operating interface
determines the function that has been selected, and transmits that information to the PCC for
tribute to the system components via a power bus and power cabling. The Backplane also pro-
vides control and signal interconnection between the system components via buses and signal
nection between system components and peripheral devices (see Figure 11-5 for connection
cabling. The FE, BF, DSC, and PCC boards are all plugged into connectors on the Backplane.
E-box Backplane The Backplane (Motherboard) is the physical and functional “backbone” of the ultrasound
with the ultrasound system. The footswitch, with freeze and display change functions, is an
User Interface The user interface comprises the controls, indicators, and output devices of the system.
extension of the control panel.
descriptions).
processing.

(HDD) The HDD, housed inside the system enclosure and connected to the PCC by an EIDE cable, con-
tains the Linux embedded operating system, ultasound application software, and COTS software.
CD-RW The CD-RW drive, housed in the system enclosure and connected to the PCC by an EIDE cable,
The MOD drive, an external device that connects to the PCC via one of the I/O panel USB con-
CSIP Level 1 Theory of Operation: Functional Description
Stick The flash memory stick, an external device that connects to the PCC via one of the I/O panel
is a removeable-media device used for image and report archiving and system upgrading.
USB connectors, is a removeable-media device used for image and report archiving.
nectors, is a removeable-media device used for image and report archiving.
The HDD stores AP&I data and ultrasound images.
Magneto-optical
Flash Memory
Disk (MOD)
Drive

Use the following checklist to review what steps are necessary for proper system installation and
Perform a pre-installation site check (page 68) ❏
Check physical access for delivery and installation (page 68) ❏
Perform electrical and environmental checks (page 69) ❏
If applicable, gather site network (DICOM) information (page 69) ❏
Uncrate and unpack the system (page 70) ❏
Inspect the system (page 71) ❏
Assemble the system (page 72) ❏
Install the peripherals (page 72). ❏
that the system is configured properly. Read this section completely before starting the system
Installation User Guide, which starts with the assumption that all pre-installation actions
Introduction This section contains pre-installation and installation information for an FSE-install of the HD3
unpacking the system, physically installing the VCR or color printer if purchased, and verifying
installation. The instructions in this section assume that the system language is set to English.
electing to install their own system will be provided with an HD3 Ultrasound System
Ultrasound System. FSE installation consists of a pre-installation site check, uncrating and
are complete, that the system and system accessories have been uncrated and
unpacked, and that the system does not have the DICOM option enabled.
to verify that you have performed them all.
Checklist

Install the system power cord (page 72). ❏
Start up and configure the system (page 72) ❏
Set or verify the institution name, user language, and time and date settings (page 73 through
page 75). ❏
Verify system options (page 76) ❏
Configure the DICOM/connectivity network, if required (page 77). ❏
Configure other system settings (optional) (page 87). ❏
Prepare the peripherals (page 87). ❏
Perform a system functional check (page 87) ❏
Present the system (page 88) ❏
Conduct an inspection of the site prior to system installation to ensure a trouble-free installation
and to assist the customer in providing an environment that supports reliable performance of the
dock, elevators, ramps, and the width of passageways and doors.
Check that the installation site is physically acceptable as follows:
system and any external peripherals.
ultrasound system.
system.
for Delivery and
Installation
Installation
Checking
Site

Verify that the system is to be installed and operated in a room or rooms that meet the electrical
If the system DICOM feature will be used, it will be necessary to have the following connectivity
- A list of all equipment that is part of the image management network. Also include device
information before entering the DICOM settings as described in “Configuring the DICOM Fea-
The customer or their contractor shall install network cabling. If in-wall cabling is used, it is the
building and fire codes. It is also the customer’s responsibility to maintain the in-wall cabling for
customer’s responsibility to install the correct type of cable in accordance with all applicable
Determine and record the following network information for later DICOM configuration:
type, model number, and software version applicable to each piece of equipment.
- Logical diagram of the network showing topology, subnets, and so forth.
and environmental requirements given in Section 2, “System Specifications”.
- Locations of all DICOM Connectivity LAN attachment points.
tor must be available to supply configuration data.
- Locations of power outlets and connector types.
- Locations of equipment.
the life of the system.
ture” on page 78.
Gathering Site
Electrical and
Requirements
Information
Checking
Network
(DICOM)

Ultrasound traffic department. Be sure to check the system for damage when it is uncrated.
Inspect the shipping container and uncrate the system as described in the following sections.
been activated. If the indicators are red, report this fact to the carrier and to the Philips
for at least 2.74 m (9 ft). (The ramp is the front side and is labeled “OPEN THIS
- IP address, subnet mask, Port number, and DICOM AE Title for the HD3 system.
- All necessary Internet Protocol (IP) addresses and subnet information.
- IP Address, Port number, and AE Title for each DICOM server.
Crate Inspect the shipping crate before unpacking the system:
- Locations of any dedicated analog phone lines.
devices) to the network.
department.
Unpacking the
System

Uncrating Uncrate the system by following the instructions in “Uncrating the HD3 Ultrasound System” on
After the system is uncrated (“Uncrating the HD3 Ultrasound System” on page 90), conduct the
nect it to AC line voltage until correct line voltage has been verified, a thorough inspection of the
page 90. (Instructions for re-crating the system for shipment are provided in Section 10, “Disas-
following inspections. Report any damage or missing inventory to the carrier and to the
system has been performed, and the system has been properly assembled.
➤To inspect the system after uncrating
Philips Ultrasound traffic department.
sembly”.)
System

If the system comes with a color printer or VCR, you will need to install it on the adjustable uni-
versal peripheral mounting plate, which is installed on the cart from the factory. Follow the color
printer or VCR installation instructions (“To install the color printer” on page 105, or “To install
already installed, install the system power cord by following the instructions in “To install the sys-
switch is pushed in) and then plug the system power cord into a proper AC outlet. Push the AC
If the system comes with a footswitch, you will need to connect it. Follow the footswitch instal-
When physical installation is complete, it is necessary and important to verify that the system is
After the system has been inspected and properly assembled as instructed in this section, verify
Mains power switch to the on position (“I” label on rocker switch is pushed in) and then press,
If the system is ordered with a B/W printer, it will come installed from the factory in the B/W
After the system has been inspected and properly assembled, if the system power cord is not
that the green AC Mains power switch (Figure 11-6) is in the off position (“O” label on rocker
mended settings (refer to “Peripheral Settings” on page 266).
Assemble the HD3 system by installing the following components.
lation instructions (“To install the foot switch” on page 119).
tem power cord” on page 121.
printer bay (Figure 1-1) .
the VCR” on page 111).
properly configured.
and Footswitch
Powering On
System Power
Assembling
Installing the
Installing the
and Config-
the System
uring the
System
Cord

for aproximately 3 seconds, the power On/Off button on the control panel to power on the sys-
At this (or a later time) you can also specify whether or not the Caps Lock setting is to be on
and instructions for configuring and operating the system, refer to the HD3 Getting Started man-
Basic initial configuration is addressed in the following sections. For detailed user information
or off at startup and whether or not to have the system automatically create a medical
record number for new patients. See “Configuring Other System Settings” on page 87.
Type in, verify, or change the name of the institution.
Local Settings ➤To check or set the institution name
The Setup window opens (Figure 5-1).
tem.
ual.


Figure 5-1 Setup Window (System)

The selected language will not take effect until the system is rebooted.
➤To verify or set the system time and date
➤To change the user interface language
The Date and Time setup window opens.
The Setup window opens (Figure 5-1).
The Setup window opens (Figure 5-1).

a. Click the corresponding Unlock button and enter the option code in the Unlock Code
dialog box that opens. It is necessary to have the System Key (based on the hard drive
options are those that the customer ordered. You must have the correct authorization code
System Options HD3 systems leave the factory with all available software options onboard. All purchased
identifier), from the top left corner of the Option window, when requesting option
options are activated, those that haven’t been purchased are not. Verify that the activated
➤ To verify or activate system software options
(password) to activate system options in the field.
The Option setup window opens (Figure 5-2).
The Setup window opens (Figure 5-1).
ing to activate an option:
authorization codes).
c. Click Save.
b. Click OK.
sales order.


Figure 5-2 Setup Window (Option)

DICOM Feature If the system you are installing has the DICOM option, you or the customer will need to config-
configure the DICOM feature with the specific values that need to be entered. At initial installa-
tion, refer the customer to the HD3 Getting Started manual, which has instructions for viewing,
The basic steps for initially configuring the system for DICOM communications over a network
specific information from the customer network administrator (see “Gathering Site Network
(DICOM) Information” on page 69), Philips recommends that you work with the customer to
setting, or changing DICOM information and gives a description of each field in the "Glossary."
ure the system DICOM feature. Since configuring the system for DICOM operation requires
- Enter the AE Title, Station Name, and Port number for the HD3 system (page 78).
- Enter the network settings for the HD3 system (page 80).
➤To configure the system DICOM parameters
The DICOM setup window opens (Figure 5-3).
The Setup window opens (Figure 5-1).
are as follows:


Figure 5-3 Setup Window (DICOM)

➤To identify the DICOM storage devices that the system will use
➤To identify the DICOM printers that the system will use
The System Network Settings window opens (Figure 5-4).
The Server Configuration window opens (Figure 5-5).
The Server Configuration window opens (Figure 5-5).
to the storage device and the printer selected.


Figure 5-4 System Network Settings Window (DICOM)




Figure 5-5 Server Configuration Window (DICOM)

The test will produce a results message similar to one of the examples shown in Figure 5-6.
stances. Do not change the settings unless you have a specific troubleshooting need.
➤To test the communication between the system and a server or a printer
The DICOM setup window opens (Figure 5-3).
The Admin setup window opens (Figure 5-7).
The DICOM Log window opens (Figure 5-8).
The Setup window opens (Figure 5-1).
The Setup window opens (Figure 5-1).
➤To configure the DICOM Log file

Wrong port number
Figure 5-6 DICOM Device Test Results Message Examples (DICOM)
Setup is correct
=
=
=





Figure 5-7 Setup Window (Admin)


Figure 5-8 DICOM Log Window

If appropriate for this installation, work with the customer and follow the respective instructions
As applies, correctly load paper and ribbon in the printers and insert a tape cassette in the VCR.
in the HD3 Getting Started manual to initially configure the system settings not yet set to the cus-
testing reveals any problems, troubleshoot, repair, and retest the system before presenting it to
turer’s default values. Printer and VCR device settings can be checked as described in
Verify system functionality using the information in Section 6, “Performance Tests”. If system
Refer to Section 6, “Customizing Your System,” in the HD3 Getting Started manual.
Confirm that the system settings are appropriate for the installed peripherals.
tomer’s preference. There are several categories of user setups:
➤To configure other system settings
“Peripheral Settings” on page 266.
the customer for use.
Functionality
Configuring
Peripherals
Checking
System
Settings

tomer’s presets and configurations, and store it where service staff and the customer can find
Show them the important safety and operating information that it conatins and that it item-
the importance of letting the system shut down completely before disconnecting the power
izes what user information has been provided for their system and peripherals.
When the system is ready, present it to the operators:
ESD and warranty considerations.
chased and its options.
permanently.
assistance.
it readily.
cord.
System


to the steps in the installation procedure.
Foot Switch
Figure 5-1 Installation Procedure List
Physical Installation Procedures
Ultrasound System
Monitor Support
Shipping Foam
Top-Mounted
Top-Mounted
Color Printer
VCR

Poly strapping bands ➤To uncrate the HD3 Ultrasound
for shipment are provided in Section,
“Disassembly (Removal) Proce-
tem is 10 minutes.
container.
dures”.

Figure 5-2 Cutting the Poly Strapping Bands
System


Figure 5-3 Removing the Corrugated Top Cover

the crate ramp.

Figure 5-4 Removing the Corrugated Wrap


Figure 5-5 Removing the Ramp Bolts

5 6 5. Lift the ramp off the pallet.
beveled edge facing up.

Figure 5-6 Placing the Ramp



Figure 5-7 Removing the System Hold-down Brace


Figure 5-8 Removing the Wheel Chock


Figure 5-9 Rotating the Rear Casters

toward the front of the ultrasound
ramp and onto the floor.
system.

Figure 5-10 Rolling the System Off the Pallet

system and off the control panel.
Foam monitor support 14. Remove the antistatic bag.
Figure 5-11 Removing the Shipping Materials (Antistatic

Bag and Monitor Support)


Foam monitor support 17. Engage the handle trigger and raise the control panel to its highest point.
packing materials to Philips.
Return to Installation Procedure List.

Figure 5-12 Removing the Shipping Materials (Yoke
Support)

➤To install the monitor support
stress during transport of the
other means of transportation.
foam is used to protect the
prevent the system from moving
while installing the foam shipping
video monitor from shake
HD3 system in vans or by
support.

Figure 5-13 Locking the Front Casters
shipping foam

system until it is in a horizontal posi-
tion above the control panel.

Figure 5-14 Tilting the Video Monitor

that the opening in the foam for the
monitor is at the top.

Figure 5-15 Placing the Foam Monitor Support


Return to Installation Procedure List.
tor to slide through the upper
cut-out.

Figure 5-16 Securing the Video Monitor


Figure 5-17 Adjusting the Universal Peripheral Mounting

Plate for the Color Printer

remove the plate.
Figure 5-18 Removing the Top Cover Access Plate Screws
Access plate

top cover using four screws.
Figure 5-19 Installing the Universal Peripheral Mounting

Mounting · plate · Plate

5 Mounting strap 5. Thread the mounting strap through the appropriate slots in the universal
peripheral mounting plate.

Figure 5-20 Installing the Mounting Strap on the
Universal Peripheral Mounting Plate

and secure the straps with the Velcro
tered on the mounting plate.
end.
Figure 5-21 Placing and Strapping the Color Printer to
the Universal Peripheral Mounting Plate


Strapped 7

Return to Installation Procedure List.
color printer cabling diagram.
Figure 5-22 Cabling the Color Printer to the HD3 System




Figure 5-23 Adjusting the Universal Peripheral Mounting

Plate for the VCR

remove the plate.
Figure 5-24 Removing the Top Cover Access Plate Screws
Access plate

top cover using four screws.
Figure 5-25 Installing the Universal Peripheral Mounting

Mounting · plate · Plate

5 Mounting strap 5. Thread the mounting strap through the appropriate slots in the universal
peripheral mounting plate.

Figure 5-26 Installing the Mounting Strap on the
Universal Peripheral Mounting Plate

the straps with the Velcro end.
the mounting plate.
Figure 5-27 Placing and Strapping the VCR to the


Universal Peripheral Mounting Plate
Strapped 7

Return to Installation Procedure List.
VCR cabling diagram.

Figure 5-28 Cabling the VCR to the HD3 System


for your use. It is recommended that
horizontal surface. Attach it with the
velcro strips supplied with the MOD
the MOD drive be mounted on a
➤To install the MOD drive
the rear of the MOD drive.
drive.
Figure 5-29 Connecting the USB Cable to the MOD Drive


USB cable

Return to Installation Procedure List.
tem Rear I/O Panel.

Figure 5-30 Connecting the USB Cable to the HD3


➤To install the foot switch
the Rear I/O panel.
assembly cable.

Figure 5-31 Foot Switch Cabling

Rear of system

Return to Installation Procedure List.

Figure 5-32 Foot Switch Placement
Front of system

➤To install the system power cord
For installing a power cord with an inline
For installing a power cord with an addi-
tional inline filter power adapter cable,
located at the lower rear of the sys-
Return to Installation Procedure List.
the power I/O box receptacle
filter, see Figure 5-33.
“O” is pushed in).
see Figure 5-34.
tem.
Figure 5-33 Connecting the System Power Cord (Power

Cord with Inline Filter)


3 Also see Figure 14-25

➤To install the system power cord
located at the lower rear of the sys-
into the power I/O box receptacle
Return to Installation Procedure List.
“O” is pushed in).
tem.
Figure 5-34 Connecting the System Power Cord (Power
cord with Separate Inline Filter Power
“adapter with inline filter”
power cord photo to be
photo to be added here
Adapter) · added here

tions if a B/W printer needs to
be installed and you don’t have
delivered with a B/W printer
access for cabling the B/W printer.
screws from inside the printer bay.
installed. Use these instruc-
it hangs below the bay and allows
Refer to Figure 11-1 for B/W printer
Return to Installation Procedure List.
the upgrade instructions.
Install the two remaining plate
cabling diagram.
printer bay.

Figure 5-35 B/W Printer Plate Storage
3 Printer plate
1 Panhead screws (4 plcs)

and right or up/down while being able to hold position without sagging when the desired
Introduction This section calls for examinations that determine functional confidence and ensure that the sys-
- Video Monitor can be tilted up or down and with the neck assembly can be rotated left
Review Section 3, “Safety” before continuing. Also follow any additional warnings and cautions
- User Interface Control Panel up/down movement can be actuated via the front handle
The goal here is to verify system functionality. If system testing reveals any problems, trouble-
power cord, connectors, and transducers for outward signs of wear or physical damage that
At initial installation and after upgrades or repairs, inspect the systemcart, controls, cables,
shoot, repair, and retest the system before presenting it to the customer for use.
tem is operating as intended at initial installation and after upgrades or repairs.
would suggest the system may not be able to function correctly and safely:
- Caster wheels all roll smoothly, both front wheel brakes lock.
latch mechanism. Movement in both directions is smooth.
- The moveable controls operate smoothly.
adjustment is completed.
contained in this section.
cations.
Warnings and
Mechanical
Cautions
Integrity
Visual

Operate the system as Philips intended (refer to the HD3 Getting Started manual as required) all
the time observing and verifying that the following is true while checking system modalities and
transducer ports.
basic operations:
correctly.
System

supply is a self-contained unit that is safety-tested by its manufacturer, so no safety test-
ing is needed when the power supply or system power cord is replaced. Safety testing
- The image printers, if installed, make a print of the system screen: Print images are cor-
played on the system monitor. The color of the printed image, if applicable, is accurate.
- The VCR, if installed, records clear video and audio (check by playing back on a review
Perform these tests after any service or maintenance to detect abnormalities that could prove
rectly positioned horizontally and vertically and contain all the information being dis-
- The report printer, if installed, prints and that all report information is present and
between the chassis and ground. See “Chassis to Ground Resistance Test” on page 127.
need only be performed during the yearly Preventive Maintenance.
leads. See “Ground Wire Leakage Current Test” on page 129.
station).
legible.
compromised:
Safety

Figure 6-1 shows the basic electrical concept of the ground resistance test. Use a safety analyzer
10 A. Test currents in excess of 1 A will likely exceed the impedance limit specification, and can damage the RFI protection finger contacts. Exposed metal on the transducer assembly, including
out allowing the user to power down normally. Interrupting the system power while the system
The limits referenced in these tests are prescribed by UL, CSA, and IEC. Local regulations may
check a transducer for electrical leakage. See “Transducer Isolation Leakage Current Test”
connected to the ultrasound system. The system sends normal operating voltages to the
This test checks the entire system for electrical resistance between the chassis and ground.
and complete “To test the system for resistance between chassis and ground” on page 129.
transducer, which is tested for leakage. See “To test transducer leakage current” on
is powered-on can result in corrupted files and could render the system inoperative.
the connector, are for RFI and are not safety grounds.
require additional tests.
on page 134.
page 133.
Chassis to
Ground


Figure 6-1 Chassis to Ground Resistance Test Diagram
R = 200 milliohms maximum
300e036 · (resistance)

The impedance test drives a load current through the ground wire while measuring the AC volt-
age drop across the entire length of the power cord and to the system chassis. The reading will
A comprehensive ground impedance measurement can be performed using the safety analyzer.
This test checks the entire system for leakage on chassis ground wires. Figure 6-2 shows the
basic electrical concept of the test. Use a safety analyzer and complete “To test the system
ground connection is open, do not touch the chassis or the patient cable.
➤To test the system for resistance between chassis and ground
check the power cord and the associated primary wiring.
ground wiring for leakage” on page 131.
be in milliohms.
Current Test
Leakage

simultaneously for Single Fault condition

1000 microamperes Single Fault condition 7ASW025
Figure 6-2 Ground Wire Leakage Current Test Diagram
1000 microamperes Single Fault condition
(current)

The solution penetrates any cracks or holes in the transducer insulation and provides an electri-
When you perform the safety tests, use saline solution in a container as a conductive medium.
A reading higher than acceptable limits can indicate a problem with the power cord, with its
Tests This section describes two electrical leakage current tests for transducers. To ensure patient
safety, it is very important to verify the integrity of the insulating layers of all transducers.
cal path between the submerged lead wire and the inner transducer shield.
The following tools are required for these transducer safety tests:
limit specified for Single Fault condition in Figure 6-2.
associated connections, or with the power transformer.
➤To test the system ground wiring for leakage
for Normal condition in Figure 6-2.
nal PC.

using a safety analyzer. Figure 6-3 shows the basic electrical concept of the Transducer Leakage
This test checks a transducer for electrical leakage while it is connected to the ultrasound sys-
tem. The system sends normal operating voltages to the transducer, and leakage is measured
Current test. Complete the procedure “To test transducer leakage current” on page 133.
Neutral wire open (ground closed) for second Single Fault condition Ground wire open for first Single Fault condition, lead
500 microamperes Single Fault condition I = 100 microamperes Normal condition,

For type transducers:
Figure 6-3 Transducer Leakage Current Test Diagram
50 microamperes Single Fault condition I = 10 microamperes Normal condition, For type transducers:
wire · Hot -

transducer. For transthoracic and endocavity transducers, submerge the head and 5 cm (2 in)
the transducer type symbol on the transducer connector or cable with the symbol in the fig-
of the cable. Be careful not to submerge the connector.
➤To test transducer leakage current
ure.)

leakage is greater than 80% of the chassis leakage, there is a fault in the transducer. To locate
into the saline solution, and leakage current in the transducer is measured using a safety analyzer.
Figure 6-4 shows the basic electrical concept of the Transducer Isolation Leakage Current test.
the transducer housing or the cable sheath. To locate a fault precisely, repeat the measure-
cable. Their leakage currents can measure within the specified limits even if there is a
for transducer leakage current, Single Fault condition obtained in step 10. If the transducer
The transducer is submerged in a container of saline solution. AC Mains voltage is introduced
ment while slowly inserting the transducer into the saline. The aberrant reading appears
Complete the procedure “To test transducer isolation leakage current” on page 136.
the fault, slowly insert the transducer in the saline, as in step 10.
fault in the outer skin. Step 11 tests for this condition.
when the fault in the cable enters the saline.


Figure 6-4 Transducer Isolation Leakage Current Test Diagram
wire · 1101e30

contact with the line voltage. Do not touch the chassis or the ECG or transducer cables while
performing the test. Keep the ECG and transducer cables at least 20 cm (8 in) from any
in) of the cable. Be careful not to submerge the connector.
➤To test transducer isolation leakage current
grounded or conductive surfaces.
tral conditions.

brightness range, or contrast range. Use the brightness controls on the control panel to set the
heights. The monitor can be tilted up and down, swiveled left and right. To position the monitor,
You can adjust the position of the monitor to suit different operating positions and operator
Introduction This section contains information for adjusting the system monitor. Except for the monitor,
there are no other calibration or alignment adjustments to make in the field for this system.
The only monitor adjustment is the video brightness, there are no adjustments for contrast,
Monitor You can adjust the brightness of the monitor image to compensate for ambient light.
There are no voltage adjustments to make in the field for this system.
grasp it by the sides and adjust the tilt and swivel to suit the operator.
Do either of the following to adjust the brightness:
➤To adjust the monitor brightness
brightness.
Positioning
the Monitor

HD3 Getting Started manual for additional information on the general care and preventive mainte-
neance of the HD3 system. QAA activities include, but are not necessarily limited to, the follow-
Introduction This section identifies activities supporting the quality assurance audit (QAA) concept that you
should perform in accordance with Customer Field Service policies and schedules. Refer to the
See Section 6, “Performance Tests” for information about checking mechanical integrity, system
Review Section 3, “Safety” before continuing. Also follow any additional warnings and cautions
Cleaning Clean the system components and peripherals as circumstaces or Customer Field Service poli-
other strong solvents to clean plastic surfaces.
performance, and electrical safety.
cies and schedules require.
contained in this section.
ing types of concerns:
Cautions

Use a vacuum cleaner, compressed air, or soft-bristle brush to remove any lint and dust from the
airflow passages and components associated with the fan assemblies, PCBs, and any other system
Refer to the HD3 Getting Started manual for information on the general care, handling, cleaning,
standard computer-cleaning products to clean the monitor, keyboard, system, and peripheral
components and peripherals that may have accumulated dust or dirt. Use mild, nonabrasive,
housings. Also, take care not to scratch the face of the monitor while cleaning it.
and storing of Philips transducers for the HD3 ultrasound system.
Clean or replace the trackball as its condition warrants.
➤To clean the trackball
Trackball
surfaces.
Assemblies · Interior

monitor, and peripherals. Also clean the control panel and knobs. Ink or stubborn stains should
Surfaces Use a rag with mild soap and water to clean exterior surfaces, including those on the system,
be removed with rubbing alcohol or a stronger detergent and immediately washed with mild,
soapy water.

find it beneficial to review it. Always make notes as you troubleshoot; if properly communicated,
contained in this section. Before taking any action that might cause data to be lost, back up data
Reviewing and applying the following basic guidelines can produce effective troubleshooting and
Review Section 3, “Safety” before continuing. Also follow any additional warnings and cautions
responsible call resolution. Even an experienced and successful troubleshooter who can solve
problems without stepping through the Effective Problem-Solving Checklist (Table 9-1), might
some or all of the information you discover can help you or others in the future.
as described in “Backing Up and Restoring” on page 151.
All Trouble-
Starts Here
shooting
Cautions

booting, or other symptom? Write down a clear statement of what the symptom is and how
Symptoms These actions and considerations can help to clearly describe a symptom, which is useful in iso-
lating the cause and can also be useful later when documenting the problem and the solution.
- How does it happen: What keystrokes, what modality, what preset, what transducer?
Put system in service and close the call “Returning the System to Service” on page 147
Verify that the system works “Verifying Corrective Actions” on page 146
Make notes about the problem you are investigating as you read through this section:
Perform a corrective action “Implementing a Solution” on page 145
Re-create the problem “Re-creating a Problem” on page 143
Develop a solution “Developing a Solution” on page 145
Identify the symptom “Clarifying Symptoms” on page 142
Basic Troubleshooting Step Link to Detailed Guidelines
Isolate the cause “Isolating Causes” on page 143
Table 9-1 Effective Problem-Solving Checklist
tem features and options set?
it manifests itself:

- Consider if the symptom indicates an operating procedural error or a system failure. If it
is a system failure, determine whether it seems to be a hardware or software problem. If
Problem Successfully re-creating a problem that doesn’t damage the system can produce information that
Isolating Causes Remember that, sometimes, more than one cause can produce similar symptoms. Try to identify
a network, during a calculation, during a measurement, playing/recording VCR, printing,
is useful to troubleshooting and solution verification. But, before you try, be sure that you have
indications of the failure. Do this as soon as possible to ensure this type of data is not lost.
cause the loss of information or will change a circumstance that is better than re-creating the
as many causes for the given symptom as your experience and research allows and then priori-
- Is it a printing problem, an image quality or viewing problem, a data export or import
it is a software problem, determine if it is an operating system or ultrasound problem.
tize them in order of most likely root cause of the problem. Attempt to eliminate them
problem. If you decide to attempt to re-create the problem, try to do so several times.
- How often does it happen: Intermittently, predictably, all of the time?
(Relevant data is often lost when the system is rebooted.)
one-by-one, staring with the most likely cause.
acquiring an image, annotating, other?
problem, or other?

disconnected or damaged wires. Always check that power cords are plugged in, and inspect
Device Manager, Debug Info, and Event Logs). A fix is typically realized by replacing sus-
with good ones. Do not cause additional problems or confuse your search. Never swap
the last time the system was working correctly and what, if any, influencing circumstances
have been able to categorize the symptom as a hardware, software, operator-induced, or
If you haven’t discovered the cause of the problem yet, more in-depth analysis is necessary:
pect/candidate hardware until the problem is resolved.
parts if a known good item might be damaged.
Check for the following obvious causes:
Investigating and Testing
environmental failure.
them for wear.
have occurred since?

the failure or corruption needs to be investigated: Is there a system architecture failure, is
pulling the plug, or other)? A solution can be more user training or a work-around. Inves-
tigate to see if an option ought to be enabled or if there is an enhancement scheduled in
sequence of your actions is important. Even if you don’t think you need to do this for yourself, it
Solution When think you know what the problem is, decide what changes you need to make to correct
tiously and systematically. Make only one change at a time, and verify that the change you made
It is not unusual for another problem to surface when you are applying changes to fix what you
can be useful to others when you properly document the problem and its resolution. You may
thought was the problem. If the change didn’t bring about the result you expected, consider if
exceeding the capability of the system, or mis-operating it (over-filling the hard drive,
the problem and write down the steps you want to take to make the repair, especially if the
Solution Implement your solution by performing the corrective actions you developed. Proceed cau-
brings about the result you expected before making any other change.
ties external to the system affecting its performance?
the user doing anything to cause the problem?
a future release that might solve the problem.
benefit from this yourself in the future.
system is failing.
Developing a

sider returning the system to the known condition it was in before your last change and verify its
actions to repair the failure, conduct whatever tests are necessary to ensure that the problem is
Review your solution and any “discovery” that your change produced. Decide if you should pro-
ceed with your original solution or go back to investigating and testing. To avoid producing con-
fusing and conflicting data, do not deviate too far from the methodical approach that allows you
fixed and that the system meets its optimum level of performance. Typically, it will be the same
testing that led you to isolating the cause of the specific problem (refer to your notes) and then
that unexpected result brings you closer to the actual cause of the problem. If it doesn’t, con-
additional tests that give you confidence that the system is generally performing as it should.
Once the system fault has been identified and you have performed (authorized) corrective
to isolate the failure by eliminating possible causes along the way.
condition before proceeding.
Verifying
Actions

Once the reported problem is fixed and the system tests are successful, return the system to the
you arrived at that conclusion, and what corrections you made. Include this information with
parts that are returned for repair and, if appropriate, send e-mail with this information to ISS
reduce interference. EMI and RFI can conceivably cause image noise or monitor distortion if the
Answering the following questions can help locate the source of interference and help determine
Disk is Full In this release, the system does not automatically manage hard drive disk space. That is, studies
EMI and RFI Electromagnetic interference (EMI) and radio frequency interference (RFI) can degrade the per-
interference. Moving the ECG cable or other medical equipment away from the transducer can
system EMI shielding has been compromised. EMI and RFI can be generated by a variety of elec-
trical devices. The interference can be transmitted over power lines or radiated through the air.
are not automatically deleted as the hard drive disk becomes full. If the disk space alloted for
formance of the HD3. For example, a transducer placed close to an ECG cable can increase
whether the problem is with the system or with the scanning environment.
studies is filled, the system may behave erratically or generate errors.
Some problem considerations are documented here.
discovered and what corrections you made.
personnel who could find it useful.
customer and close the call:
Causes, and
Symptoms,
Checking for
Corrective
System to
Actions
Service

RFI shielding has been compromised. One place to start is to verify that all the system panels
difference between these terms because the causes are different, the troubleshooting techniques
A “hang” is when the system stops responding to the keyboard. There is a normal image on the
correct and continues changing), but the system does not respond to hard keys, soft keys, or the
There is not any specific data associated with a “hang” (because from the software point of view,
everything is behaving normally. The best source of information is to ask the customer about the
the system is shielded against EMI and RFI, troubleshoot the system to determine if the EMI/
or Crashes Often the terms “hang” and “crash” are used interchangeably to describe the same symptom.
However, these two terms describe two different behaviors. It is important to understand the
monitor and the system may continue to be working (updated data in the image area, clock is
noise on the radio while walking it around the room. Sometimes EMI/RFI sources are not
EMI/RFI source tester) identify interference, which would be noticeable as audible static
constant, but are temporary or surge situations that may only occur at certain times.
are appropriately secured with all of the factory-approved fasteners.
are different, and the information available to the FSE is different.
keystrokes prior to a “hang.” Also check the Keystroke Log.
trackball.

Verify that the DICOM option is enabled (See “Verifying the System Options” on page 76.). If the
If the DICOM server is using high-security settings, you may need to add the system AE Title and
A “crash” occurs when the system detects an abnormal condition in either the hardware or the
presses buttons and different parts of the software are used, different segments of “vir-
tual memory” are acquired and released. Virtual memory is handled on the hard drive
large enough “chunk” for the system to do what is needed. If this happens, the system
setting, the system performs two tests, “TCP/IP Ping” to verify that it can connect to the speci-
If the TCP/IP Ping test fails, make sure the IP address and port number specified for the system
and as it is used and released, it is subject to fragmentation. After a while, the virtual
DICOM Feature” on page 78.), including the DICOM network test. When you test a network
fied IP address and “DICOM Verify” (C-ECHO command) to verify that it can connect to the
and for the DICOM server are correct. If the DICOM Verify test fails, make sure the AE Title
specified for the system and for the DICOM server are correct. The AE Title is case-sensitive;
software. A crash is an unexpected software event that causes the system to diaplay an error
memory area can become fragmented into small pieces, so that there is no longer a
DICOM option is enabled, verify that it has been configured correctly (See “Configuring the
IP address to the server’s list of systems that are authorized to access it.
message and forces the user to re-boot the system.
make sure it has been entered correctly.
specified DICOM server.
can crash.)
DICOM/
Failures

You may want to view or copy the DICOM log (see “To display the keystroke or DICOM log” on
In addition to the messaging presented to you during Setup and Export, the HD3 has a DICOM
log that records DICOM network activity. The DICOM log contains the following information:
page 153.)

ting Started manual. System settings, DICOM (network) settings, and options are saved when
Subsequent releases of the ultrasound application software will be available on CD ROM. Instal-
The HD3 has the capability of updating device drivers without the need to upgrade or Ghost the
back up patient exams as described in Section 12, “Review,” of the HD3 Getting Started man-
application software. This is also described in Section 16, “System Administration,” of the HD3
screen as described in Section 16, “System Administration,” of the HD3 Getting Started manual.
Before you begin installing software, replacing a hard drive, or taking any service action that
lation is accomplished by inserting the CD into the CD-RW drive and accessing the Admin
To manage system options, See “Verifying the System Options” on page 76.
might cause data to be lost, perform the following tasks:
you perform a backup.
Getting Started manual.
ual.
Software and
Backing Up
Managing
Loading
Drivers
System
Options

the log files to a CD, MOD, or USB flash memory drive. The keystroke log is always running,
DICOM activity logs. Use Keystroke Log and DICOM Log to specify log settings and to view
tion. (In the first release, only “hard key” presses are recorded; Softkey presses and “mouse
clicks” in Review mode are not recorded). Any user can view keystroke logs, as well as copy
and as the current file becomes full, it is closed, renamed with a date-time stamp, and a new
As with the keystroke logs, you can view the DICOM logs, or copy them to CD, MOD, or USB
Use the Admin tab in setups to display system information, and to view the keystroke and
- The Called and Calling devices and their communication parameters
log files, copy log files onto removable media, and to delete log files.
The HD3 has some software tools that are accessible to all users:
- The number of images expected to be sent
- The number of images successfully sent
current keystroke log file is started.
- The number of images that failed
- Status of the export operation
tains the following information:
- Service & Transfer Type
flash memory drive.
mation and
Viewing
Logs

- Enter the number of days a log file should be active. For example, if you enter 31 days,
the log file is deleted when it becomes older than 31 days.
- Enter the maximum size of the log file in kilobytes.
➤To display the keystroke or DICOM log
➤To display system information
ple keystroke logs.

Introduction This section provides specific information about system disassembly that may be required for the
means of removing a system part can be discerned from the illustrations in this section as well as
first. ESD symptoms may be first exhibited as a slight degradation of performance or image qual-
from those in Section 13, “Configuration” and Section 14, “Parts”. Instructions for crating the
Review Section 3, “Safety” before continuing. Also follow any additional warnings and cautions
removal and installation of field-replaceable parts. If not covered by a detailed procedure, the
according to local, state, and federal laws. Do not replace individual batteries in the
least 30 seconds before removing or installing any PCB, module, or component.
field. Return all products containing mercury to Bothell for disposal.
Refer to Figure 10-1 for links to disassembly procedures by specific part.
system for shipment are also included.
contained in this section.
ity.
Cautions


VCR or Color Printer List Continued

to the steps in the disassembly procedure.
Figure 10-1 Disassembly Procedure List (1 of 2)
the reverse of the disassembly procedure.
Video Monitor
Control Panel

Crating the HD3
System Casters
Figure 10-2 Disassembly Procedure List (2 of 2)
to the steps in the installation procedure.
Power I/O Box
Previous List

rear to remove it. Proceed to step 4.
be removed before removing
B/W printer, hard drive, CD drive,
tly slide the enclosure toward the
➤To remove the system enclo-
the front enclosure or top
cord from the main AC supply.
enclosure allows access to the
and transformer.
cover.
Figure 10-3 Removing the Left Side Enclosure
sures · screws (2 · plcs)

enclosure allows access to the E-box
rear to remove it. Proceed to step 6.
tly slide the enclosure toward the
and power supply assemblies.
Figure 10-4 Removing the Right Side Enclosure
screws (2 · plcs)

front panel slide out of the top cover
Return to Disassembly Procedure List (1
slots.
of 2).

Figure 10-5 Removing the Front Enclosure
Tabs

➤To remove the system monitor
screws securing the monitor assem-
cord from the main AC supply.
bly to the control panel.
step 4.
Figure 10-6 Removing the Video Monitor
AC supply · Splitter board

Return to Disassembly Procedure List (1
This completes the video monitor
removal procedure.
splitter board.
of 2).

Figure 10-7 Disconnecting the Video Monitor Cables


Figure 10-8 Removing the Top Control Panel Enclosure


step 6.
Figure 10-9 Tilting the Top Control Panel Enclosure

cable connections from the control
panel board.

Figure 10-10 Disconnecting the Control Panel Cables

the cable connected to the control
This completes the trackball removal
panel board.
panel board.
procedure.

Figure 10-11 Removing the Trackball Assembly

of the cable connected to the con-
trol panel board.
trol panel board.

Figure 10-12 Removing the Keyboard Assembly
9 Keyboard cable connection

Return to Disassembly Procedure List (1
with the following procedure.
control panel housing.
board.
board.
of 2).

Figure 10-13 Removing the Splitter Board

➤To remove the VCR or the color
Return to Disassembly Procedure List (1
peripheral.
of 2).

Figure 10-14 Removing the VCR or the Color Printer

printer · Color printer VCR

➤To remove the universal periph-
proceeding with the following proce-
Return to Disassembly Procedure List (1
to the HD3 system top cover.
dure.
of 2).
Figure 10-15 Removing the Universal Peripheral Mounting

mounting plate 1
eral mounting plate · Panhead screws · Plate

➤To remove the B/W printer, CD/
removed if you are only remov-
the CD/Hard drive rack, other-
dure in the sequence presented
all the steps before proceeding with
ing either the B/W printer or
wise follow the entire proce-
to remove the printer bay or
Hard drive rack, power trans-
Figure 10-3 needs to be
former, and printer bay
the following procedures.
power transformer.
Figure 10-16 Peripheral Bay Components

B/W printer 2. With the black and white printer in place, disconnect all the cables from
the rear of the unit.
printer bay.
Figure 10-17 Disconnecting the B/W Printer Cables and
Removing the Printer Retaining Bracket
Retaining bracket

the rear of the two units.
the system.
Figure 10-18 Disconnecting the Drive Cables and
Removing the Drive Rack Assembly
Panhead screws (2 plcs)

Printer bay 8. Remove the four screws securing the printer bay to the cart frame.
the system.
Figure 10-19 Removing the B/W Printer Bay

frame.

Figure 10-20 Power Transformer Cable Tie

approximately three inches toward
the rear of the system.

Figure 10-21 Sliding the Transformer Back

of the power I/O box. Only discon-
the underside of the system.
nect these two cables.
Figure 10-22 Removing the Power I/O Box
Panhead screws (4 plcs) 13

Return to Disassembly Procedure List (1
the system.
of 2).
Figure 10-23 Removing the Power Transformer
Power · transformer

E-box boards, power supply and
removal before proceeding with the
following procedures. To remove the
transducer connector assembly, pro-
removed if you are only remov-
➤To remove the E-box assembly,
service without removing the
Figure 10-4 needs to be
E-box from the system.
ing the power supply.
ceed to step 14.
E-box Bay (E-box Assembly, Transducer Connector
Figure 10-24 E-box Bay Components

board, proceed to step 4. To remove
the E-box boards, proceed to step 8.
case.

Figure 10-25 Removing the E-box Rear Shield
clarity of illustration

E-box.
Figure 10-26 Disconnecting the Power Supply Power Cord


toward the front of the system until
you feel the power supply release. It
Slot 5 5. Disengage the power supply by plac- ing a slotted screwdriver into the
does not take much pressure to do
fans or Backplane board proceed to
slot at the rear side of the E-box
case. Gently pry the screwdriver
step 11.
this.

Figure 10-27 Removing the Power Supply

the FE and BF boards.

Figure 10-28 Removing the BFC Board

ers to release the board from the
Backplane board.

Figure 10-29 Removing the FE, BF and DSC Boards

ground lugs (green wires) connected
on the end of the board and the one
removed in order to access the
one cable that connects to the
cable connected on the side of the
plane board and slide the board out
13 11. To remove the PCC board, discon- nect the four main cables and two
of the card cage and place it on an
loosen the two connector screw
lugs. Pull the connector off the
side of the PCC board.
anti-static mat.
board.
board.
Figure 10-30 Removing the PCC Board




Figure 10-31 Removing the Transducer Connector
Assembly (TCA) · Panhead screws

ing fans proceed to step 24.
bay.

Figure 10-32 Removing the E-box Assembly
E-box shown removed for
clarity of illustration

case.

Figure 10-33 Removing the Backplane Board Shield



Fans 24. Disconnect the two speaker cables from the top of the Backplane board.
Return to Disassembly Procedure List (1
E-box case.
of 2).

Figure 10-35 Removing the E-box Cooling Fans

removed before removing the
➤To remove the Rear I/O panel
tly slide the enclosure toward the
Rear I/O assembly.
rear to remove it.
Figure 10-36 Removing the Left and Right Side Enclosures
Screws (2 plcs) 2
assembly

box opening below. If this
drop into the Power I/O
happens you will have to
the four Rear I/O panel
remove the Power I/O
that the screws don’t
box to retrieve them,
Figure 10-40.
Figure 10-37 Removing the Rear I/O Panel
assembly screws, ensure

PCC interface cable 6 B/W printer cables (if used) 6 6. Pull the Rear I/O panel assembly out of the cart frame enough to discon-
nect all the cables connected to the
Rear I/O panel assembly board.
Figure 10-38 Disconnecting the Rear I/O Panel Assembly

PCB Cables

Return to Disassembly Procedure List (2
I/O panel assembly frame.
panel assembly frame.
of 2).
Figure 10-39 Removing the Rear I/O Panel Assembly PCB
Panhead screws (3 plcs) 9
Bezel · Frame · Rear I/O PCB

removed before removing the
tly slide the enclosure toward the
➤To remove the Power I/O box
Power I/O box.
rear to remove it.
Figure 10-40 Removing the Left and Right Side Enclosures
Screws (2 plcs) 2

E-box.
Figure 10-41 Disconnecting the Power Supply Power Cord

Figure 10-42 Cutting the Cable Ties on the Power Cables

Return to Disassembly Procedure List (2
system over on its front casters so
that the control panel handle rests
on the protector pad.
Power I/O box PCB.
of 2).

Figure 10-43 Removing the Power I/O Box

➤To remove the lift column gas
removal and perform all the steps
visible and accessible.
before proceeding.
Figure 10-44 Lowering the Control Panel
strut · Gas strut

socket).
Figure 10-45 Removing the Gas Strut from the Ball Stud
Ball socket Ball stud
Keeper pin · Gas strut · Keeper pin

eyelet on the lock bracket. The gas
strut is now removed.
Ball stud and bracket
Figure 10-46 Removing the Gas Strut from the Lock
Gas strut Lock bracket
Bracket

Gas strut 8. Remove the four screws securing the gas strut mount access plate to the
lower cart frame.
Figure 10-47 Removing the Gas Strut Mount Access Panel

bracket eyelet upward until you see
the screw hole. Hold it in that posi-
tion.
snug.
Figure 10-48 Installing the Gas Strut into the Lock Bracket
Eyelet (rotate upright) · Lock bracket

Return to Disassembly Procedure List (2
place.
of 2).
Figure 10-49 Inserting the Gas Strut onto the Ball Stud

age from toppling, tilt the
control panel surface and
floor. To reduce the risk
of injury or system dam-
monitor down onto the
lower the control panel
require that the system
be tipped over to the
➤To remove a system casters
to its lowest position.
Figure 10-50 Preparing the System for Caster
Replacement

system over on its front casters so
that the control panel handle rests
on the protector pad.

Figure 10-51 Tipping the System to Remove the Rear
System positioned · on front side · Casters

system over on its right side (for left
side (for right front caster removal).
trol panel transducer holder rests on
Return to Disassembly Procedure List (2
front caster removal) or on its left
Orient the system so that the con-
the protector pad.
of 2).

Figure 10-52 Tipping the System to Remove the Front

prevent the system from moving dur-
perform this procedure. This
➤To crate the HD3 Ultrasound
package contains all the hard-
crate package to be able to
ware necessary for proper
ing the crating procedure.
shipping.
Figure 10-53 Locking the Front Casters
System

the control panel to its highest posi-
tion.

Figure 10-54 Raising the Control Panel


cover and then fold it around the lift
column.

Figure 10-55 Placing the Foam Yoke Support

support

the control panel until it rests firmly
against the foam yoke support.

Figure 10-56 Lowering the Control Panel
Foam yoke support

system until it is in a horizontal posi-
tion above the control panel.
Figure 10-57 Tilting the Video Monitor

that the opening in the foam for the
monitor is at the top.
Figure 10-58 Placing the Foam Monitor Support

tor to slide through the upper
cut-out.
Figure 10-59 Securing the Video Monitor

foam arm extensions hook and hold
the two foam arms extending from
the foam monitor support in place.
through the holes. Push until both
the foam yoke support come
Figure 10-60 Fastening the Two Foam Supports Together

Foam yoke support extension arms

Foam yoke support · Foam monitor support

cover every part of the system
ers, the antistatic bag must
that contacts the crate.
Figure 10-61 Covering the System with an Antistatic Bag


positioned at the lower end and fac-
ing up.

Figure 10-62 Placing the Ramp

crate toward the front of the system.
12 12. Unlock both front casters by press- ing down on each caster tab lock
crate floor support. The rear of the
underside of the system into the
system should be facing the ramp
and onto the crate, guiding the
side of the crate.
release.

Figure 10-63 Loading the System onto the Crate
Caster tab lock release

Crate · floor · support


Figure 10-64 Rotating the Rear Casters

of the casters.

Figure 10-65 Placing the Wheel Chock


Figure 10-66 Placing the System Hold-Down Brace

edge up and facing outward.

Figure 10-67 Mounting the Ramp to the Crate

so that the wrap fits on the inside of
The corrugated wrap should be set
each corner retainer bracket.

Figure 10-68 Placing the Corrugated Wrap

place at each corner.

Figure 10-69 Placing the Corrugated Top Cover

Return to Disassembly Procedure List (2
ping bands.
of 2).

Figure 10-70 Banding the System Crate
Poly strapping bands

numbers are shown on the illustrations and are listed and described in the corresponding tables.
System signal interconnect and power distribution cabling diagrams are shown in Figure 11-1 and
and parts tables in this section to locate and identify system cables and their part numbers. Part
Table 11-1 is a parts list of the interconnect cables shown in Figure 11-1 and the power distribu-
Introduction This section contains system cabling and connector information. Use the illustrations (figures)
tion cables shown in Figure 11-2. Refer to Table 14-2 for additional information on peripherals
Figure 11-4 through Figure 11-11 are illustrations of the system primary connector assemblies.
Figure 11-2. For reference, system-to-peripheral connection diagrams are provided in
Figure 11-1 through Figure 11-3.
and applicable cables.
Cable Part
Diagrams
Numbers
Cabling
System
System


Figure 11-1 HD3 Ultrasound System Signal Interconnect Diagram
J6
J7 GP1
Cable is part of


Video monitor E-box/Power supply
power cord part numbers
See Cable Parts List for
VCR (Figure 11-3) (Figure 11-2)
(Figure 11-1)
Figure 11-2 HD3 Ultrasound System Power Distribution Diagram
JP1 JP5 JP4 JP3 JP2

453561227921 Cable Assy, Black and White Printer, Power Manufacturing No: WH-439-PWR-05-00
453561227761 Cable Assy, CD/Hard Drive, Power Manufacturing No: WH-439-PWR-04-00
453561227791 Cable Assy, CD/Hard Drive, Data Manufacturing No: WH-439-SIG-08-00
453561226081 Cable Assy, Keyboard Data Manufacturing No: WH-439-SIG-07-00
453561232921 Cable Assy, CD-RW, External Power Manufacturing No: WH-439-PWR-07
453561226851 Cable Assy, E-Box Power Manufacturing No: WH-439-PWR-06
453561227971 Cable Assy, Foot Switch Adapter Manufacturing No: WH-339-PWR-03
2275-0038 Cable Assy, BNC, Rear I/O Panel to B/W Printer, 36-In Alias No: 453561129851
3500-1622-01 Cable Assy, Print Trigger Alias No: 453561018331
Part Number Cable Description Notes/Reference
Table 11-1 HD3 System Signal and Power Cable Part Numbers
List

453561222271 Cable Assy, Keyboard, Power Manufacturing No: WH-439-PWR-03-00
453561224291 Cable Assy, QWERTY Keyboard Manufacturing No: WH-439-SIG-05-00
453561227931 Cable Assy, PCC to Rear I/O Panel Manufacturing No: WH-439-SIG-03-00
453561226041 Cable Assy, Power Adapter with Filter Manufacturing No: ADAPTOR-FILTER
Table 11-1 HD3 System Signal and Power Cable Part Numbers (Continued)
Part Number Cable Description Notes/Reference

with power cords have integrated line filters
All remaining shipments of HD3 systems use
without an integrated line filter can be used.
If the HD3 system does not have the power
one of the two power cords with integrated
the Cable Assy, Power Adapter with Filter.
adapter with filter, you should use ONLY
453561225681 Cable Assy, Power Cord, 110 Vac with Filter Inital shipments of HD3 systems shipped
With this "universal filter", power cords
(453561225681 or 453561225711).
Table 11-1 HD3 System Signal and Power Cable Part Numbers (Continued)
Part Number Cable Description Notes/Reference
line filter.

with power cords have integrated line filters
cords without an integrated line filter can be
If the HD3 system does not have the power
one of the two power cords with integrated
adapter with filter, you should use ONLY
453561225711 Cable Assy, Power Cord, 220 Vac with Filter Inital shipments of HD3 systems shipped
All remaining shipments of HD3 systems
use the Cable Assy, Power Adapter with
Filter. With this "universal filter", power
(453561225681 or 453561225711).
Used for top-mounted OEM’s
UK/Singapore/Hong Kong Main AC system power cord
2275-0482-01 Cable Assy, Power Cord, Peripheral Alias No: 453561013471
Table 11-1 HD3 System Signal and Power Cable Part Numbers (Continued)
Part Number Cable Description Notes/Reference
line filter.
used.
453563468451 Cable Assy, Power Cord, System,
Figure 11-3

Australia/New Zealand Main AC system power cord
Continental Europe Main AC system power cord
USA/Canada/Japan Main AC system power cord
Switzerland/Lietenstein Main AC system power cord
Denmark/Greenland Main AC system power cord
Africa/India Main AC system power cord
Israel Main AC system power cord
Argentina Main AC system power cord
China Main AC system power cord
453561012981 Cable Assy, RCA-RCA, Stereo, Molded, 6-Ft Used for top-mounted VCR
Table 11-1 HD3 System Signal and Power Cable Part Numbers (Continued)
Part Number Cable Description Notes/Reference
453563468461 Cable Assy, Power Cord, System,
453563468471 Cable Assy, Power Cord, System,
453563468481 Cable Assy, Power Cord, System,
453563468491 Cable Assy, Power Cord, System,
453563468501 Cable Assy, Power Cord, System,
453563468511 Cable Assy, Power Cord, System,
453563468521 Cable Assy, Power Cord, System,
453563468531 Cable Assy, Power Cord, System,
453563468541 Cable Assy, Power Cord, System,

453561226091 Cable Assy, Splitter Board Power Manufacturing No: WH-439-PWR-01-00
453561226111 Cable Assy, Splitter Board Data Manufacturing No: WH-439-SIG-02-00
453561222241 Cable Assy, Trackball Manufacturing No: WH-439-SIG-01-00
Used for top-mounted OEMs
154899 Cable Assy, S-VHS, Shielded, 6-Ft Alias No: 453561000921
Table 11-1 HD3 System Signal and Power Cable Part Numbers (Continued)
Part Number Cable Description Notes/Reference
Figure 11-3

HD3 Rear I/O Panel

Figure 11-1 Sony UP-895MD B/W Printer Cabling Diagram
Diagrams
Cabling
(side view) · (back side) · (Analog)

HD3 Rear I/O Panel HD3 Power I/O Box

Figure 11-2 Sony UP-21MD Color Printer Cabling Diagram

HD3 Rear I/O Panel HD3 Power I/O Box


Figure 11-3 Mitsubishi HS-MD3000UA/EA VCR Cabling Diagram

Figure 11-4 HD3 System Connector Locations (Front Panel)
Black & white printer
Illustrations
System

See Figure 11-10 for Rear I/O
VGA

Figure 11-5 HD3 System Connector Locations (Rear I/O Panel)
Color composite video out
B/W composite video out


Power supply connector (See Figure 11-7 for Power I/O
Figure 11-6 HD3 System Connector Locations (Power Connectors)
- Power supply -
Power supply cable receptacle

Figure 11-7 HD3 System Connector Locations (Power I/O Box Connectors)
Xfmr Xfmr B/W printer Power supply
Hard drive and disk drive
- Rear view with cover removed -
Fuse

Module Splitter board J2)

Figure 11-8 HD3 Video Monitor PCB Cable Connector Locations

Figure 11-9 HD3 Control Panel PCB Cable Connector Locations (Splitter Board)
J1 J2
J6
SPLITTER POWER SPLITTER DATA
LCD IF POWER LCD IF DATA
KEY POWER KEY DATA
J3

See Figure 11-5 for Rear I/O
Figure 11-10 HD3 Rear I/O PCB Internal Cable Connector Locations (Side View)
Rear I/O Panel PCB
Rear of system cart
B/W printer BNC connnector (J16)
Remote In connector (J17)
(Connects to PCC J18)

Figure 11-11 HD3 PCC PCB Cable Connector Locations
J16
J7 J12
J5
J4
J3
J6
Signal connectors (J6, J7)
(Connects to Hard drive and disk drive)
(Connects to Hard drive and disk drive)
(Connects to Splitter board J3)
(Connects to Rear I/O PCB J2)
Signal connectors (J11, J16)
(Connects to monitor GP1 and J7)

releases. Unless noted under “Hardware Changes,” hardware changes do not always accompany
system software releases.Any hardware part number additions or changes that accompany these
the compatibility of primary system PCBs and certain hardware assemblies with respect to the
Introduction This section summarizes the software and hardware changes associated with specific software
a software release. See Section 13, “Configuration” for part numbers of the released software
versions. Contact your Philips representative for the core information you need to determine
Philips Ultrasound released the HD3 Ultrasound System for customer orders in August 2005.
releases are incorporated into the respective sections of this manual.
Build 085)
(v1.00.00
Release

Introduction This section lists all of the released software version part numbers for the system, identifies the
primary system PCBs, and shows where these PCBs are located in the system. When applicable,
This section also contains configuration information such as the as-shipped system BIOS settings,
hard drive jumper positions, and the Philips-recommended settings for the optional OEM periph-
Contact your Philips representative for the core information you need to determine the compat-
The HD3 primary PCB names and locations are shown in Figure 13-1through Figure 13-4. These
ibility of primary system PCBs and certain hardware assemblies with respect to the system soft-
Software release levels and corresponding part numbers are listed in Table 13-1. See for a sum-
marized history of the software and hardware changes associated with specific software releases.
v1.00.00 .085 453561228661 System software initial release
figures provide linked references to the corresponding PCB illustration.
Table 13-1 System Software CD Part Numbers
No. Disk Part No. Notes
additional PCB reference information is provided.
erals sold with the system.
ware releases.
Primary PCBs
Locating and
Information
Identifying
Software
System
Version Build · Released · Software

The following conventions apply to the PCB reference information provided in this section:
unless an authorized procedure instructs otherwise. Not all potentiometers are shown.
service representatives at installation. All configurable devices may not be shown.
not necessarily to scale. Not all components and test points are shown.
configuration of new PCBs.
Reference
PCB


Figure 13-1 HD3 Primary System PCB Names and Locations (E-box)

Figure 13-2 HD3 Primary System Board Names and Locations (Rear I/O Panel)
Rear I/O board · See Figure 13-15

Figure 13-3 HD3 Primary System PCB Names and Locations (Power I/O Box)
Power I/O board · See Figure 13-16

Figure 13-4 HD3 Primary System PCB Names and Locations (Control Panel)
Bottom half of control panel
See Figure 13-7 · Splitter board

LCD IF board LCD board

Figure 13-5 Video Monitor PCBs (Back of Monitor LCD)

PCBs
Compatibility · Information

Figure 13-6 Control Panel Interface and Keyboard PCBs (Top Half of Control Panel)

PCBs
Compatibility · Information


Figure 13-7 Control Panel Splitter Board (Bottom Half of Control Panel)
Figure 13-4 · Compatibility · Information


- Front - - Back -
Figure 13-8 Transducer Connector Assembly (TCA)

Figure 13-1 · Compatibility · Information



Figure 13-9 Backplane Assembly


Information - Front - - Back -
Figure 13-10 Beamformer - to - Frontend Connector (BFC)

Figure 13-1 · Compatibility


Figure 13-11 Front End (FE) Assembly


Figure 13-12 Beamformer (BF) Board
Figure 13-1 · Compatibility · Information


Figure 13-13 Digital Scan Converter (DSC) Board
Figure 13-1 · Compatibility · Information


Figure 13-14 PCC Board
Figure 13-1 · Compatibility · Information


Figure 13-15 Rear I/O Panel PCB
PCB
Figure 13-2 · Compatibility · Information


Figure 13-16 Power I/O Box PCB
PCB
Figure 13-3 · Compatibility · Information

The jumper positions and switch settings of the drives in the HD3 system depend on the manu-
Jumpers Figure 13-17 shows typical hard drive jumper positions. Examine the drive itself for information
on the correct settings. The hard drive is the only device on the primary IDE, and is usually set
MASTER = ON
Power connector Signal connector
B
I G
H
Figure 13-17 Hard Drive Jumper Settings
to MASTER or SINGLE.
facturer of the drives.
Settings

Jumpers Figure 13-18 shows typical CD-RW drive jumper positions. Set the jumper to the MASTER posi-
Figure 13-18 CD-RW Drive Jumper Position
tion on the secondary IDE.
MA = MASTER
SL = SLAVE
CD-RW Drive

The initial Philips-recommended peripheral settings for use with the HD3 system are provided in
B/W Printer The Sony UP-895MD has DIP switches on the back of the printer. The Philips-recommended DIP
this section (“B/W Printer” on page 266, “Color Printer” on page 267, and “VCR” on page 271).
switch settings for use with the HD3 system are given in Table 13-2.
Table 13-2 UP-895MD Printer Switch Settings
(The power must be turned on to access the switches inside the
Jumpers Set the MOD drive jumpers to SLAVE on the secondary IDE.
CONTROL SETTING
NOR/SML NOR
POSI/NEGA POSI
STD/SIDE SIDE
SMOOTHING OFF
BRIGHT 6 CONT 7
Inside the Paper Tray
GAMMA II
MOD Drive
Peripheral
Settings
Front of Printer

Table 13-2 UP-895MD Printer Switch Settings (Continued)
Color Printer The Philips-recommended UP-21MD settings are listed in Table 13-3.
NTSC Settings PAL Settings
Table 13-3 UP-21MD Printer Settings
HD3 Default Settings1
Load Color: 1 1 CYN – RED: 0 0 MAG – RGB: 0 0 YEL – BLU: 0 0 Dark: 1 1 Light: -3 -3
DIP Switches 1-12 Down
Menus and Parameters · Rear of Printer

Table 13-3 UP-21MD Printer Settings (Continued)
NTSC Settings PAL Settings
H Width: 976 Dots 912 Dots V Width: 476 Dots 548 Dots Save: Press [EXEC] Press [EXEC]
IRE.: 100 100 Save User: 1 1
HD3 Default Settings1
Window:
Menus and Parameters

Table 13-3 UP-21MD Printer Settings (Continued)
NTSC Settings PAL Settings
RM2 Func.: C&Print C&Print
Immed. Cap.: OFF OFF
HD3 Default Settings1
Color Balance:
Function:
Menus and Parameters

Table 13-3 UP-21MD Printer Settings (Continued)
NTSC Settings PAL Settings
HD3 Default Settings1
tomer order.
Menus and Parameters

VCR The VCR has front/rear panel switches, displayed menu settings, and hidden menu settings. Mit-
subishi HS-MD3000U/E VCR settings for use with the HD3 are given in Table 13-4, Table 13-5,
Table 13-5 to enter the settings listed. (Only the numerical code that corresponds to setting is
shipped with new systems. However, when a replacement VCR is ordered, you will
The displayed menu settings are listed in Table 13-5. To verify or reset these settings, see “To
The hidden menu settings are listed in Table 13-6. To verify or reset these settings, see “To
change the VCR displayed menu settings” on page 275. Enter the numerical code from
need to check the switch settings and menu settings
change the VCR hidden menu settings” on page 276.
displayed. You will not see the setting titles.)
and Table 13-6.

Table 13-4 HS-MD3000U/E VCR Control and Switch Settings
75 Ohm Video ON ON
75 Ohm S-Video ON ON

(Not Displayed) Numeric Code
Table 13-5 HS-MD3000U/E VCR Displayed Menu Settings
Rec Tape End Stop Stop 101:00 Tape End Stop Stop 102:00 Tape In Stop Stop 103:00 Tape Length T-120 E-180 104:00 VISS REC REC 105:01 Time Code Rec. OFF OFF 106:00 Time Code Disp OFF OFF 107:00 Foot Switch L.E. L.E. 108:00 Dimmer OFF OFF 109:00
S-VHS/S-ET ON/OFF Auto 201:01 Y-NR ON ON 202:01
C-NR ON ON 203:01 Y-Enhancer ON ON 204:01 TBC ON ON 205:01 Color Filter OFF OFF 206:00 Freeze Mode Frame Frame 207:00
(Not Displayed) PAL Setting

system also provides these functions and the VCR clock is not likely to be used. If the VCR clock is
set, it will cause the normal (standby) display of the VCR to display the time of day rather than tape
location time, which may be confusing to some users. Pressing RESET restores these settings to the
RESET and cycle through the languages displayed on the VCR display. Remember, pressing RESET
Month 01 01 Do not set
Day 01 01 Do not set
Year 2004 2004 Do not set
Time 00:00:00 00:00:00 Do not set
Table 13-5 HS-MD3000U/E VCR Displayed Menu Settings
Hi-Fi Audio ON ON 208:01 Normal Audio In MIX MIX 209:00
date set) 301:00
Language English (displayed) English (displayed) 001:00
set) OFF (No time/
factory defaults shown, but also resets the Language setting (see 2).
also restores the VCR clock settings to the factory defaults (see 1).
Daylight Savings OFF (No time/date
Language Menu2 · Menu 31

Table 13-6 Mitsubishi HS-MD3000E/U VCR Hidden Menu Settings
Setting/Item Display NTSC Setting PAL Setting
Picture Control (Sharpness) PC 0 0 (Head) Switching Point SP 65 65 Position Up/Down Ud 0 0 Position Left/right Lr 0 0 Chroma Amplitude CA 2 2 Hue (Color Phase) CP 0 0 Color Delay Cd 2 2
CC 1 1 bd ON ON
➤To change the VCR displayed menu settings
bC –1 –1

➤To change the VCR hidden menu settings

Go to the “HD3 Ultrasound System Parts Locator Map” Figure 14-1 to start your search or one
In this manual, system field-replaceable parts and cables are shown in illustrations and are listed
The part number is included in the figure and is linked to the corresponding parts table where a
Or, to find a part number by its description, look in the parts tables Table 14-1, which are alpha-
Use the parts and cable illustrations to visually locate and identify the part you are looking for.
Introduction This section contains general and specific parts information for the HD3 Ultrasound System.
of the other applicable parts information links as follows:
betized by the part descriptions.
part description is provided.
in tables.
How and
Number
a Part

hypertext cross-reference linking to the parts/cable tables containing parts descriptions and addi-
Parent View Illustration Label “PARENT VIEW” indicates an illustration that provides links
Parts Locator Map) by clicking the “System View” button in the lower left corner of any figure in
tional information. The “Parts List” can also be accessed by clicking one of the blue part numbers
See Figure “See Figure” is a hypertext cross-reference link to a detail (subassembly) figure. In
the subassembly figure you will find either the part number, a reference to another detail figure,
“SYSTEM VIEW” (System Parts Locator Map). You can return to the “SYSTEM VIEW” (System
Parts List Button The “Parts List” button (located on the “System Parts Locator Map” only)
is a hypertext cross-reference linking to the “Parts Table” containing parts descriptions and addi-
System View Button The “System View” button is a hypertext cross-reference link to the
Installation Button The “Installation” button is a hypertext link to a figure’s corresponding
Item Number The item number for each part or subassembly shown in an illustration is a
Parent View Button The “Parent View” button is a hypertext link to the parent-part or
System View Illustration Label The “SYSTEM VIEW” (System Parts Locator Map),
or a reference to the table containing parts descriptions and additional information.
to additional parts breakdown, indicated with a “See Figure” reference.
Figure 14-1 contains links to “PARENT VIEW” illustrations.
in any of the figures in this section.
installation/removal procedure.
“PARENT VIEW” illustration.
tional information.
this section.
1, 2, 3, etc

Item No. This column lists the item numbers that correspond to parts in the parts illustrations.
only if you are in North America or Canada, or you order directly from Bothell. These numbers
correspond to the PR1 SAP system. If a table is referenced in this column, the part number is on
for parts orders worldwide. These numbers correspond to the MIP SAP system used by the SLIs
priate, the description column also includes size, tolerance, type or model, and material data for
Attaching parts must be ordered separately. They are not provided with the assembly, the subas-
Green Arrow The green arrows found throughout the parts illustrations are used to indicate
Legacy Part Number This column lists the legacy part number for an item. Use this column
12NC Part Number This column lists the 12NC part number for an item. Use this column if you are ordering from an APEC, an EMEA, or an LATAM country. 12NC numbers can be used
Disassembly Button The “Disassembly” button is a hypertext link to figures corresponding
Part Description The name or common description of the item is listed here. Where appro-
and Miami. If a table is referenced in this column, the part number is on that table.
movement (direction, rotation), or point to a specific area (details, breakdowns).
Located On This column lists all of the figures on which the part is found.
the part. Parts tables are alphabetized by this column.
sembly, or the component being attached.
to a disassembly/assembly procedure.
that table.
Disassembly

applications, and other information pertaining to a specific part are listed in the Notes/Reference
column. For top assemblies containing many replaceable parts, the applicable figure or table for
cessing Department. Customers ordering parts through an FSE will need to provide the follow-
Customers can order parts through an FSE or directly from the Customer Service Order Pro-
For parts ordering procedures, FSEs should refer to their standard operating procedures.
further breakdown of parts is listed here.
ing information:
Ordering
Parts

Figure 14-1 HD3 Ultrasound System Parts Locator Map (Front and Rear Views)

- Front - - Rear -

See Figure 14-3 Video monitor
See Figure 14-5 Control panel
See Figure 14-19 B/W printer
See Figure 14-12 E-box
See Figure 14-11 Cart (Internal)
Illustrations

End Views - Right side -
See Figure 14-27 Peripheral top deck
See Figure 14-29 System Casters
Figure 14-2 HD3 Ultrasound System Parts Locator Map (Right Side)


LCD front panel and housing
Figure 14-3 Video Monitor Assembly

Figure 14-4 Video Monitor Assembly (LCD Front Panel and Housing)

splitter board See Figure 14-8 Keyboard and trackball
Figure 14-5 Control Panel
See Figure 14-9 Shipping foam

Knob, TGC (6 plcs)
Figure 14-6 Control Panel (Knobs and Cable Hooks)
Knob, rotate (2 plcs)


Figure 14-7 Control Panel (Top, Handle and Splitter Board)

Figure 14-8 Control Panel (Keyboard and Trackball)

Figure 14-9 Control Panel (Monitor Support Shipping Foam)
System View · Parent View · Installation


Screw (2 plcs) Screw (4 plcs)
Figure 14-10 System Enclosures

See Figure 14-23 Power I/O box assembly
See Figure 14-22 Rear I/O panel assembly
See Figure 14-26 Lift column assembly
Figure 14-11 Cart (Internal)
See Figure 14-12 E-box assembly


Figure 14-12 E-box Assembly
See Figure 14-17 E-box cooling fans
See Figure 14-13 E-box front


Figure 14-13 Transducer Connector Assembly (TCA) and E-box Motherboard
(Front Side of E-box)

Figure 14-14 E-box Boards and Power Supply Access Panel (Rear-side of E-box)



Figure 14-15 Power Supply and BFC Board


Figure 14-16 E-box Boards

(4 plcs each fan)

Figure 14-17 E-box Cooling Fans

Figure 14-18 Peripheral Bay Components
See Figure 14-21 Power transformer


Figure 14-19 B/W Printer Bay

Figure 14-20 Hard Drive and CD Drive Rack

Figure 14-21 Power Transformer

Figure 14-22 Rear I/O Panel Assembly

PCB and fuse holder
453561232931 Screw (2 plcs)
Parent View Screw (4 plcs)
Figure 14-23 Power I/O Box Assembly
Inline filter power cord

Figure 14-24 Power I/O Box (PCB and Fuse Holder)


Figure 14-25 Power I/O Box (Inline Filter Power Cord and Cord Retainer)

Figure 14-26 Lift Mechanism (Mechlok Assembly and Gas Strut)


Figure 14-27 Peripheral Top Deck (VCR or Color Printer and MO drive)

Figure 14-28 Peripheral Mounting Plate (Uni-mount)

Figure 14-29 System Casters
Bolts (4 plcs each caster)

System View MO drive assembly

Figure 14-30 MO Drive
453561217871 · Parent View · Installation


Figure 14-31 Foot Switch Assembly and Adapter Cable

System View RM-91 remote print switch

Figure 14-32 RM-91 Sony Color Printer Remote Control Print Switch
989605300741 · Parent View

System View R-3001 VCR remote control

Figure 14-33 R-3001 Mitsubishi VCR Wired Remote Control
453561228091 · Parent View


Figure 14-34 System Labeling (HD3 System Nameplate)
453561233541 (2 plcs) · System View

Figure 14-7 453561232941 Bracket, Cable Adjustment Control panel mechanical cable bracket
Figure 14-26 453563470981 Cable Assy, MechLok Mechanical cable used on the MeckLok
Figure 14-14 453561227741 Cover, E-box Manufacturing No: ASP-439-ECOVER
Figure 14-20 453561227711 Bracket, CD/Hard Drive Manufacturing No: 235-P-317A-00
Figure 14-11 453561228081 Cart Manufacturing No: ASP-439-CART
Figure 14-25 2975-0117-01 Bracket, Plug, HDI 4000 AC power cord retainer bracket
Figure 14-7 453561221091 Control Panel Assembly Manufacturing No: ASP-439-KBD
Figure 14-29 453561221161 Caster, Front (Wheel) Manufacturing No: 333-Z-701-1
Figure 14-29 453561221181 Caster, Rear (Wheel) Manufacturing No: 333-Z-015A
Figure 14-7 453561232951 Clamp, Cable, P-Clip Manufacturing No: CLA-N5-01
Figure 14-7 453561227311 Control Panel Lower Housing Manufacturing No: A215-169A
On Part Number Part Description Notes/Reference
Table 14-1 HD3 Ultrasound System Parts List
Figure 11-2 Table 11-1 Cables, Power Distribution
Figure 11-1 Table 11-1 Cables, Signal Interconnect
assembly · Figure 14-7 · Located

Figure 14-30 453561217871 Drive, MO, 1.3GB Manufacturing No: PC-MO-MDK3130UK
Used in fuse holder located on power I/O
Figure 14-17 453561221151 Fan Assembly, E-box Manufacturing No: AY-FAN-439-TOP-00
Figure 14-31 453561217911 Foot Switch Assembly Manufacturing No: FOOT-S/W UNIT-00
See “Cable Assy, Foot Switch Adapter”
Figure 14-19 453561232911 Fastener, Printer Bay Manufacturing No: ASP-439-SPRBAY
Figure 14-12 453561227731 E-box Assembly Manufacturing No: ASP-439-EBOX
B/W printer retainer bracket
Figure 14-20 453561219871 Drive, CD-RW Manufacturing No: PC-CD/
Figure 14-24 2775-0010-01 Fuse, 50T10L250V, Schuter, OEM Service Alias No: 453561096111
Figure 14-24 453561232231 Fuse Holder, 2 Pole, Snap-In Mount Part of power I/O box
On Part Number Part Description Notes/Reference
Figure 14-20 453561156821 Drive, Hard Disk, Seagate, 80GB Manufacturing No:
Figure 14-26 Gas Strut Lift mechanism
Table 14-1 HD3 Ultrasound System Parts List (Continued)
power supply · box · Located

Figure 14-19 453561227911 Housing Assy, Printer Bay, Black and White Manufacturing No: ASP-439-PRBAY-00
Figure 14-4 453561222231 LCD Panel Assembly Manufacturing No: ASP-439-LCD-00
Figure 14-7 453561226121 Handle, Front, Top Manufacturing No: 252-M-035A-00
Figure 14-28 453561227721 OEM Tray Assembly Universal peripheral mounting plate
Figure 14-10 453561228141 Panel, Bottom Manufacturing No: 215-M-315A-00
Figure 14-10 453561228121 Panel, Front Manufacturing No: 215-M-327A-00
Figure 14-10 453561228101 Panel, Left Side Manufacturing No: 215-M-328A-00
Figure 14-10 453561228111 Panel, Right Side Manufacturing No: 215-M-329A-00
Figure 14-10 453561228131 Panel, Top Manufacturing No: 215-M-316A-00
Figure 14-6 453561226241 Hanger, Cable, Control Panel Manufacturing No: 255-P-009A-00
Figure 14-8 453561222251 Keyboard Assembly, QWERTY Manufacturing No: ASP-439-ANK
Figure 14-34 453561233541 Label, Nameplate, System Manufacturing No: 275-K-A244A
Figure 14-23 453561232931 Insulator, Power I/O Assembly Manufacturing No: 323-Z-008A
Figure 14-10 453561227951 Handle, Rear, Power Cable Manufacturing No: A255-008A
One on each side of system
On Part Number Part Description Notes/Reference
Figure 14-26 453563470971 MechLok Assembly Lift mechanism
Table 14-1 HD3 Ultrasound System Parts List (Continued)
circuit boards · HD3 Badge · Located

Figure 14-7 453561222261 PCB Assy, Splitter Board Manufacturing No: BD-439-SPLITTER-0A
Figure 14-15 453561221131 Power Supply Assembly, E-box Manufacturing No: AY-439-POWER-00
Figure 14-24 453561228071 Power I/O Assembly Manufacturing No: AY-439-I/O-Box-00
Figure 14-16 453561215531 PCB Assy, Digital Scan Converter (DSC) Manufacturing No: BD-439-DSC-0A
Figure 14-13 453561216341 PCB Assy, Motherboard (Backplane) Manufacturing No: BD-439-MTH-0A
Figure 14-16 453561215541 PCB Assy, Processor (PCC) Manufacturing No: BD-439-PCC-0A
Figure 14-15 453561216331 PCB Assy, Beamformer Connector (BFC) Manufacturing No: BD-439-BFC-0A
Figure 14-32 989605300741 Remote Control, Sony, RM-91 Remote print switch used for color
Figure 14-16 453561215501 PCB Assy, Beamformer (BF) Manufacturing No: BD-439-BF-0B
Figure 14-22 453561217921 PCB Assy, Rear I/O Panel Manufacturing No: BD-439-RP-0A
Figure 14-22 453561227961 Rear I/O Housing Manufacturing No: ASP-439-RH
Figure 14-16 453561227981 PCB Assy, Front End Manufacturing No: ASP-439-FE
Figure 14-33 453561228091 Remote Control, VCR Wired, R-3001 Remote control used for VCR
Connects BF and FE PCBs
On Part Number Part Description Notes/Reference
Table 14-1 HD3 Ultrasound System Parts List (Continued)

For use when transporting the system in
Slides over control panel for support of
Figure 14-27 453561003641 Strap, Universal OEM One strap required to secure OEM to
Figure 14-21 453561227901 Transformer Manufacturing No: ASP-439-TRANS-00
Figure 14-4 453561221081 Video Monitor Housing Manufacturing No: ASP-439-RMNT-00
Figure 14-3 453561221061 Video Monitor Assembly Manufacturing No: ASP-439-MNT-00
Figure 14-13 453561219861 Transducer Connector Assembly Transducer Select Assembly (TCA)
Figure 14-8 453561221211 Trackball Assembly Manufacturing No: 335-C-007A-00
Figure 14-9 Shipping Foam, Keyboard Manufacturing No: 364-Z-094A
vans or other mobile units.
On Part Number Part Description Notes/Reference
the video monitor.
Table 14-1 HD3 Ultrasound System Parts List (Continued)
peripheral mounting plate · Located

No. Part Description Part Number Power Cable Signal Cable References
UP-895MD, Sony 2100-1855-01 453561227921 2275-0038 Alias No:
2 Printer, Color, UP-21MD, Sony 2100-1852-01 2275-0482-01 154899 Alias No:
Table 14-2 Peripherals and Applicable Cables
Parts List

No. Part Description Part Number Power Cable Signal Cable References
Mitsubishi 453561169651 2275-0482-01 154899 (Signal) 453561012981 (Audio)
Mitsubishi 453561169661 2275-0482-01 154899 (Signal) 453561012981 (Audio)
Table 14-2 Peripherals and Applicable Cables (Continued)
3 VCR Assy, HS-MD3000UA, NTSC,
4 VCR Assy, HS-MD3000EA, PAL,

Introduction This section summarizes general and parts information for the transducers that can be used with
representative or an authorized distributor. Transducer covers and other supplies and
accessories can be ordered from CIVCO Medical Instruments: See “Supplies and
Accessories” on page 40.
the HD3 system:

Center Frequency 3.0 MHz Radius of Curvature 26mm Number of Elements 128 Element Pitch 0.328 mm Elevation Aperture 12 mm Elevation Focus Depth 70.0 mm Applications Abdominal; pediatric; cardiac adult
Transducer Type Curved linear array
Philips Part Number 453561201051
Table 15-1 C4-2 Information
Parameter Specification

Center Frequency 3.0 MHz Radius of Curvature 38.7 mm Number of Elements 128 Element Pitch 0.401 mm Elevation Aperture 15.75 mm Elevation Focus Depth 83.0 mm Applications Abdominal; pediatric; obstetrical;
Transducer Type Curved linear array
Philips Part Number 453561201041
Table 15-2 C5-2 Information
gynecological and fertility · Parameter Specification

Center Frequency 4.5 MHz Radius of Curvature 50 mm Number of Elements 128 Element Pitch 0.474 mm Elevation Aperture 11 mm Elevation Focus Depth 80.0 mm Applications Abdominal; pediatric; obstetrical;
Transducer Type Curved linear array
Philips Part Number 453561201061
Table 15-3 C7-3 Information
gynecological and fertility · Parameter Specification

Center Frequency 6.5 MHz Radius of Curvature 1.0 mm Number of Elements 128 Element Pitch 0.205 mm Elevation Aperture 6 mm Elevation Focus Depth 38.0 mm Applications Obstetrical; gynecological and fertility;
Transducer Type Endocavity curved linear array
Philips Part Number 453561201081
Table 15-4 C9-4ec Information
Parameter Specification · prostate

Center Frequency 7.5 MHz Radius of Curvature 38.4 mm Number of Elements 128 Element Pitch 0.3 mm Elevation Aperture 6 mm Elevation Focus Depth 20.0 mm Applications Small parts and superficial; pediatric;
Philips Part Number 453561201071
Transducer Type Linear array
Table 15-5 L9-5 Information
musculoskeletal; vascular · Parameter Specification
In dieser Anleitung genannte Seiten – Hersteller, Support und Downloads.
Besitzer und unser Team antworten in der Regel innerhalb eines Tages – und Ihre Frage hilft auch anderen weiter.
Stellen Sie die erste Frage — andere Nutzer oder unser Team antworten Ihnen.