C1518M-A (11/02) 3 IMPORT ANT SAFEGUARDS AND W ARNINGS 1. Read, keep, and follow these instructions. 2. Heed all warnings. 3. There are no user -serviceable parts inside this unit. Only authorized service personnel may open the unit. 4. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
4 C1518M-A (11/02) Figure 1. Front View with Panel Removal OVERVIEW DESCRIPTION The REL2064 Relay Interface Unit provides up to 64 single-pole, single-throw (SPST) dry contact outputs for direct or automatic control of peripheral equipment.
C1518M-A (11/02) 5 REAR VIEW The rear of the REL2064 unit consists of the following: 1. Four groups of 16 contact pairs, each with mating plugs for the attachment of peripheral equipment; only the group for the first 16 contact pairs is shown in Figure 2 with mating plugs 2.
6 C1518M-A (11/02) Figure 3. Rack-Mount Installation WIRING RELA YS The relay unit has four groups of relay contacts. Each group represents 16 pairs of relay contacts: • Group I – 1-8, 9-16 • Gr.
C1518M-A (11/02) 7 Figure 4. Relay Interface Contact Configuration 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 1 2 3 4 5 6 7 8 9 10 1 1 12 13 14 15 16 00702.
8 C1518M-A (11/02) Figure 5. Wiring Relays to Peripheral Equipment 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 32-122F (0-50C) + — 9 WA RNING: W ARNING: 00703.
C1518M-A (11/02) 9 CONNECTING TO THE CM6800 Connect the supplied RJ-45 straight cable from the REL2064 OUT port to the CM6800 COM 3 port. The active pin-outs are associated with the four outer pins: 1, 2, 7, and 8.
10 C1518M-A (11/02) SETTING THE DIP SWITCHES The positioning of the DIP switches on the front of the relay unit deter mines how the relay unit operates. Y ou must recycle pow er whenever you make changes to the DIP switches. 1. Remove the front panel by unscrewing the five flat-head Phillips screws.
C1518M-A (11/02) 11 2. Set the DIP switches. Figure 7. SW1 DIP Switches DIAGNOSTICS: OFF LOCAL DEVICE ADDRESS ON 1 2 3 4 5 6 7 8 9 10 NOT USED: OFF DEF AUL T SETTINGS: LOCAL DEVICE ADDRESS 1, DIP SWIT.
12 C1518M-A (11/02) OPERA TION The function of the relay unit is to operate relays to control peripheral equipment. Each relay unit processes and executes only commands with addresses that match those of the relay units. When power is turned on, the green power LEDs on the front and back of the unit light.
C1518M-A (11/02) 13 OPERA TING RELA YS FROM THE KBD960 To operate relays from a KBD960 keyboard, you must know which GPI to call, and which auxiliary (AUX) to select on the keyboard. Y ou can cascade two relay units. Each relay unit has eight GPIs. Relay Unit 1 has a GPI range of 1-8, and Relay Unit 2 has a GPI range of 9-16.
14 C1518M-A (11/02) Table D. Relay Unit 1 GPI Relay Contacts 1 12345678 29 1 0 11 12 13 14 15 16 31 7 1 81 92 02 12 22 32 4 42 5 2 62 72 82 93 03 13 2 53 3 3 43 53 63 73 83 94 0 64 1 4 24 34 44 54 64 74 8 74 9 5 05 15 25 35 45 55 6 85 7 5 85 96 06 16 26 36 4 Associated Aux 12345678 Table E.
C1518M-A (11/02) 15 Figure 10. Power Input Fuse Replacement Problem Why were the contact positions lost when there was a power failure? Why is the unit not operating as it should? What is the DB9 port used for? Solution Make sure DIP switches 3-6 of SW3 are enabled so that your settings remain in memory .
16 C1518M-A (11/02) DIP Switch Address 12345678 1 00000000 2 10000000 3 01000000 4 11000000 5 00100000 6 10100000 7 01100000 8 11100000 9 00010000 10 10010000 11 01010000 12 11010000 13 00110000 14 10.
C1518M-A (11/02) 17 DIP Switch Address 12345678 125 00111110 126 10111110 127 01111110 128 11111110 129 00000001 130 10000001 131 01000001 132 11000001 133 00100001 134 10100001 135 01100001 136 11100.
18 C1518M-A (11/02) Figure 11. REL2064 Dimension Diagram 19.00 (48.26) PWR ALARM REL2064 Relay Interface Unit Made in USA 17.40 (44.20) 1.75 (4.45) 8.15 (20.
C1518M-A (11/02) 19 REVISION HISTORY Manual # Date Comments C1518M 5/01 Original version. C1518M-A 11/02 Updated manual to new format. Revised T able A and updated T able B. ® Pelco, the Pelco logo, Spectra, Genex, Esprit, Camclosure, and Legacy are registered trademarks of Pelco.
World Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.
Ein wichtiger Punkt beim Kauf des Geräts Pelco REL2064 (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Pelco REL2064 noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Pelco REL2064 - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Pelco REL2064 reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Pelco REL2064 erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Pelco REL2064 besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Pelco REL2064 verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Pelco REL2064. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Pelco REL2064 gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.