Benutzeranleitung / Produktwartung KBD300A des Produzenten Pelco
Zur Seite of 40
Pelco • 3500 Pelco Way • Clovis, CA 93612-5699 USA • www.pelco.com In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150 International Customers: Tel +1 (559) 292-1981 or FAX +1 .
[ 2 ] Pelco Manual C527M-L (3/04).
Pelco Manual C527M-L (3/04) [ 3 ] CONTENTS Section Page IMPORT ANT SAFETY INSTRUCTIONS .................................................................................................. ......... 5 REGULA TORY NOTICES .................................
[ 4 ] Pelco Manual C527M-L (3/04) List of Illustrations Figure Page 1 Wiring Diagram for Local/Remote Keyboards ................................................................................... 10 2 Keyboard Cabling Diagram .........................
Pelco Manual C527M-L (3/04) [ 5 ] IMPORT ANT SAFETY INSTRUCTIONS Read these instructions. Keep these instructions. Heed all warnings. Follow all instructions. Do not use this apparatus near water . Clean only with dry cloth. Do not block any ventilation openings.
[ 6 ] Pelco Manual C527M-L (3/04) REGULA TORY NOTICES This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference re- ceived, including interference that may cause undesired operation.
Pelco Manual C527M-L (3/04) [ 7 ] DESCRIPTION The KBD300A Universal Keyboard has many operational features (refer to T able A) and can be used in nu- merous operational modes: CM6700 Mode: Program and operate the CM6700 Matrix Switcher/Controller Unit (SCU).
[ 8 ] Pelco Manual C527M-L (3/04) T able A. KBD300A Operational Features CM6700/ Direct CM6700 CM6800 Direct Function CM6800 P* ASCII** ASCII** D** Automatically recognize the mode Y es Y es No No No .
Pelco Manual C527M-L (3/04) [ 9 ] INST ALLA TION – CM6700 MODE There are two keyboard ports on the CM6700 SCU. The LOCAL KEYBOARD port is for connecting a single keyboard within a distance of 25 feet (7.6 meters). The REMOTE KEYBOARD(S) port is for connecting additional remote keyboards.
[ 10 ] Pelco Manual C527M-L (3/04) Figure 1. Wiring Diagram for Local/Remote Keyboards Figure 2. Keyboard Cabling Diagram KBDKIT 25-FOOT KEYBOARD DAT A CABLE KBD KBD ADDITIONAL KEYBOARDS USER-SUPPLIED.
Pelco Manual C527M-L (3/04) [ 11 ] INST ALLA TION – CM6800 MODE Y ou can connect up to eight KBD300A keyboards to any of the following ports: For the CM6800-48X8: COM 5 (one direct-powered keyboard .
[ 12 ] Pelco Manual C527M-L (3/04) Figure 3. Data Cables Plugged into COM 5 and 6 (CM6800-48X8 Shown) COM 1 1 2 3 4 5 6 7 8 16 8 7 32 31 4 3 VI DE O O UTPUTS 120/ 230~ 50/ 60 HZ 25 W ATTS COM ALAR M 1.
Pelco Manual C527M-L (3/04) [ 13 ] Connecting KBD300A Remote Keyboards For remote keyboard connections, use COM 5, 6, 7, or 8 for the CM6800-48X8 and COM 4 and 5 for the CM6800-32X6. Each port can support up to eight KBD300A keyboards. Do not exceed 16 total keyboards for the CM6800-48X8 and eight total keyboards for the CM6800-32X6.
[ 14 ] Pelco Manual C527M-L (3/04) Figure 4. Connecting Remote Keyboards (CM6800-48X8 Shown) COM 1 1 2 3 4 5 6 7 8 16 8 7 32 31 4 3 VI DE O O UTPUTS 120/ 230~ 50/ 60 HZ 25 WA TTS COM ALAR M 123 45 678.
Pelco Manual C527M-L (3/04) [ 15 ] INST ALLA TION – CM6700 ASCII MODE One ASCII keyboard can be installed, using either an RS-232 or RS-422 interface.
[ 16 ] Pelco Manual C527M-L (3/04) Set the keyboard DIP switches for ASCII Mode according to the instructions in the Switch Settings section. Plug in the keyboard data cable. Plug the +12 VDC power supply into a suitable outlet. Plug the KBDKIT or KBDKIT -X transformer into a suitable outlet.
Pelco Manual C527M-L (3/04) [ 17 ] RS-422 Interface (CM6700) Refer to Figure 6. Remove the cover from the CM6700 SCU and verify that the DIP switches for COM 2 are set for RS-422. Refer to the COM 2 Port section in the CM6700 Installation/Operation Manual for setting the switches.
[ 18 ] Pelco Manual C527M-L (3/04) KBDKIT RJ-45 WALL BLOCK TERMINALS POWER UP SCU REPLACE COVER SCU COM 2 PIN 12 (RX+) 11 (RX-) 8 (TX-) 7 (TX+) WALL BLOCK TERMINAL 1 (TX+) 2 (TX-) 7 (RX-) 8 (RX+) TO 1.
Pelco Manual C527M-L (3/04) [ 19 ] INST ALLA TION – CM6800 ASCII MODE RS-232 Interface (CM6800) An RS-232/RS-422 converter and power supply (Pelco part number PV130) are required. They are not included and must be ordered separately . Refer to Figures 7 (CM6800-48X8 shown) and 9.
[ 20 ] Pelco Manual C527M-L (3/04) Apply power to the CM6800 (if not already powered). T o initialize the keyboard, wait five seconds after power -up, enter the number for the monitor you are viewing, and press MON. The LED display shows the number entered.
Pelco Manual C527M-L (3/04) [ 21 ] RS-485 Interface (CM6800) Refer to Figures 8 (CM6800-48X8 shown) and 9. Use an existing CM6800 keyboard to program the COM 4, 7, or 8 communication port (CM6800-48X8) or COM 4 communications port (CM6800-32X6). (If there is no other keyboard, use the one you are installing.
[ 22 ] Pelco Manual C527M-L (3/04) COM 1 1 2 3 4 5 6 7 8 16 8 7 32 31 4 3 VI DEO OU TPUTS 120/ 230~ 50/60 HZ 25 W ATTS COM ALARM 123 45 6 78 CONT ROL PTZ OUT AT + T - R + R - T + T - R + R - B 1 2 F 3 COM 4, 7, OR 8 6 NOTE: A SEPARA TE PA TH MUST BE PROVIDED FOR VIDEO TO THE MONITOR.
Pelco Manual C527M-L (3/04) [ 23 ] PIN 1 PIN 8 COM PORTS 1, 2 RS-232 PIN 1 PIN 8 COM PORT 3 M, RS-485 PIN 1 PIN 8 COM PORT 4 RS-485 PIN 1 PIN 8 COM PORTS 5, 6 RS-485 1-----Rx 2-----NC 3-----NC 4 5----.
[ 24 ] Pelco Manual C527M-L (3/04) INST ALLA TION – DIRECT MODE The keyboard is wired directly to a maximum of 16 receivers. Y ou can communicate using Pelco P Protocol or Pelco D Protocol. Direct Mode installation/operation is not the same as CM6700 Mode or CM6800 Mode installation/operation.
Pelco Manual C527M-L (3/04) [ 25 ] Figure 10. Direct Keyboard and Receiver Wiring 6 REPLACE COVER 2 3 4 5 6 7 18 KBD300A 25-FOOT KEYBOARD DATA CABLE TO RECEIVER(S) RX-/RX+ TWISTED PAIR 12 V A C TX- TX.
[ 26 ] Pelco Manual C527M-L (3/04) SWITCH SETTINGS To set the switches on the keyboard (refer to Figure 11): Remove the two screws and the DIP switch cover plate from the rear of the keyboard. Set the switches: • Address (Switches 1-4) Position the switches according to T able B.
Pelco Manual C527M-L (3/04) [ 27 ] PROGRAMMING AND OPERA TION T able D. Keyboard Functions Circled numbers refer to Figure 13. Function Procedure Select Monitor* LED display shows monitor number in run mode. Enter monitor number and press MON to select.
[ 28 ] Pelco Manual C527M-L (3/04) T able D. Keyboard Functions (continued) Function Procedure Patterns Programming and operation varies with the receiver type. Spectra ® domes (before version 3.0) can use one long (1 minute) or two short (0.5 minute) patterns.
Pelco Manual C527M-L (3/04) [ 29 ] T able D. Keyboard Functions (continued) Function Procedure Auxiliaries/ For the CM6700: Relays F1 – F3 control only the auxiliaries built into the CM6700 SCU. These outputs can be programmed for momentary , keyed, latched, or alarm op- eration.
[ 30 ] Pelco Manual C527M-L (3/04) Figure 12. Keyboard Functions T able E. KBD300A Button Functions Reference Number Description 1 LED display 2 Shift key 3 Shift key LED 4A-C Sequence keys: Previous, Next, Hold 5 Function keys F1/Latch, F2/Off, F3/Mom control auxiliaries.
Pelco Manual C527M-L (3/04) [ 31 ] T able F . Operating Scan Functions with V arious Receivers Function Receiver Controlling Auto Random Frame Preset Stop Model Protocol Scan Scan Scan Scan All 15-bit.
[ 32 ] Pelco Manual C527M-L (3/04) Programming Limit Stops Spectra and Esprit can be programmed for scan and manual limit stops. Program left limit before programming right limit. Locate camera at desired limit. Enter the set code from T able G. Hold the PRESET key for two seconds.
Pelco Manual C527M-L (3/04) [ 33 ] Zones The Zone function is available on Esprit and Spectra positioning systems when operated through a CM6700 or CM6800 switch.* This function puts a label on the screen to identify the viewing area. Zones can also be blanked to prevent viewing while the camera is positioned in the zone.
[ 34 ] Pelco Manual C527M-L (3/04) SPECIFICA TIONS GENERAL Keyboard Keypad: Electromechanical Joystick: 3-axis, vector -solving, with twisting, return-to-center head Digital Display: Red LED, 7-segmen.
Pelco Manual C527M-L (3/04) [ 35 ] CM6800 ASCII Mode Interface: RS-485 Protocol: Pelco ASCII Baud: 9600 Communication Parameters: 8 data bits, 1 stop bit, odd parity Direct P Mode Interface: RS-485 Pr.
[ 36 ] Pelco Manual C527M-L (3/04).
Pelco Manual C527M-L (3/04) [ 37 ] REVISION HISTOR Y Manual # Date Comments C527M 11/97 Original version. C527M-A 1/98 Revised manual to include Direct Mode Installation/Operation instructions. Added CM6700 Operations instructions. C527M-B 4/98 Revised installation instructions as a result of hardware changes to the rear panel of the CM6700 SCU.
.
Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy , and Spectra are registered trademarks of Pelco. Endura and ExSite are trademarks of Pelco. © Copyright 2004, Pelco.
W orld Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .
Ein wichtiger Punkt beim Kauf des Geräts Pelco KBD300A (oder sogar vor seinem Kauf) ist das durchlesen seiner Bedienungsanleitung. Dies sollten wir wegen ein paar einfacher Gründe machen:
Wenn Sie Pelco KBD300A noch nicht gekauft haben, ist jetzt ein guter Moment, um sich mit den grundliegenden Daten des Produkts bekannt zu machen. Schauen Sie zuerst die ersten Seiten der Anleitung durch, die Sie oben finden. Dort finden Sie die wichtigsten technischen Daten für Pelco KBD300A - auf diese Weise prüfen Sie, ob das Gerät Ihren Wünschen entspricht. Wenn Sie tiefer in die Benutzeranleitung von Pelco KBD300A reinschauen, lernen Sie alle zugänglichen Produktfunktionen kennen, sowie erhalten Informationen über die Nutzung. Die Informationen, die Sie über Pelco KBD300A erhalten, werden Ihnen bestimmt bei der Kaufentscheidung helfen.
Wenn Sie aber schon Pelco KBD300A besitzen, und noch keine Gelegenheit dazu hatten, die Bedienungsanleitung zu lesen, sollten Sie es aufgrund der oben beschriebenen Gründe machen. Sie erfahren dann, ob Sie die zugänglichen Funktionen richtig genutzt haben, aber auch, ob Sie keine Fehler begangen haben, die den Nutzungszeitraum von Pelco KBD300A verkürzen könnten.
Jedoch ist die eine der wichtigsten Rollen, die eine Bedienungsanleitung für den Nutzer spielt, die Hilfe bei der Lösung von Problemen mit Pelco KBD300A. Sie finden dort fast immer Troubleshooting, also die am häufigsten auftauchenden Störungen und Mängel bei Pelco KBD300A gemeinsam mit Hinweisen bezüglich der Arten ihrer Lösung. Sogar wenn es Ihnen nicht gelingen sollte das Problem alleine zu bewältigen, die Anleitung zeigt Ihnen die weitere Vorgehensweise – den Kontakt zur Kundenberatung oder dem naheliegenden Service.